Bench testing of auto-adjusting positive airway pressure devices
Open accessThe DOI matches its Crossref record; 4 of the 4 references it cites were found in a registry or an index.
Abstract
Continuous positive airway pressure devices are routinely used to treat sleep breathing disorders. Automated devices that adjust the therapeutic pressure have recently been proposed. The utility of such devices is still controversial, as rigorous clinical comparisons are difficult to perform as a result of patient and device differences. The current authors studied automated devices in a respiratory model that was able to mimic upper airway mechanics and to interact with pressure adjustment in a closed loop. Five auto-adjusted devices were submitted to this model, in order to determine their ability to detect respiratory events and adjust pressure accordingly. All apnoeas were suppressed, whilst the reaction to repetitive hypopnoeas was dependent on the airflow shape. In some devices, repetitive hypopnoeas were changed to flow limitation. Artificial snoring caused a pressure increase in four devices, and constant mask leak was not systematically compensated. Only one device did not raise pressure in response to central apnoeas with opened upper airways. These findings show that, in some devices, event classification failed and normal airflow was not fully restored, resulting in elevated residual event indices. In conclusion, this model is useful in order to reproducibly compare diagnostic and therapeutic capacities of commercial devices as a first step, before costly clinical studies.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Upper airway pressure-flow relationships in obstructive sleep apnea
Smith, P. L., Wise, R. A., Gold, A. R., Schwartz, A. R., & Permutt, S. (1988) · Journal of Applied Physiology · doi:10.1152/jappl.1988.64.2.789 · Cited by 446
Comparison between Automatic and Fixed Positive Airway Pressure Therapy in the Home
Massie, C. A., McArdle, N., Hart, R. W., Schmidt-Nowara, W. W., Lankford, A., Hudgel, D. W., Gordon, N., & Douglas, N. J. (2003) · American Journal of Respiratory and Critical Care Medicine · doi:10.1164/rccm.200201-022oc · Cited by 177 · cited 2×
“It has been demonstrated that, in patients requiring high pressures, compliance was statistically increased [ 7 ].”
BackgroundAutoadjusting CPAP Therapy Based on Impedance Efficacy, Compliance and Acceptance
RANDERATH, W. J., SCHRAEDER, O., GALETKE, W., FELDMEYER, F., & RÜHLE, K.-H. (2001) · American Journal of Respiratory and Critical Care Medicine · doi:10.1164/ajrccm.163.3.2006168 · Cited by 143 · cited 1×
“Given the wide variety of algorithms used by these devices [ 15-18 ], clinical tests do not allow general conclusions to be derived for particular apparatus that are valid in all patients.”
MethodConstant vs Automatic Continuous Positive Airway Pressure Therapy
d'Ortho, M.-P., Grillier-Lanoir, V., Levy, P., Goldenberg, F., Corriger, E., Harf, A., & Lofaso, F. (2000) · Chest · doi:10.1378/chest.118.4.1010 · Cited by 103 · cited 1×
“and clinically tested for several years [1-7].”
Cited by
Adherence to Continuous Positive Airway Pressure Therapy: The Challenge to Effective Treatment
Weaver, T. E., & Grunstein, R. R. (2008) · Proceedings of the American Thoracic Society · doi:10.1513/pats.200708-119mg · Cited by 1,680
Evaluation of autoCPAP devices in home treatment of sleep apnea/hypopnea syndrome
Meurice, J. C., Cornette, A., Philip-Joet, F., Pepin, J. L., Escourrou, P., Ingrand, P., & Veale, D. (2007) · Sleep Medicine · doi:10.1016/j.sleep.2007.03.019 · Cited by 52
Self-citationZhu, K., Roisman, G., Aouf, S., & Escourrou, P. (2015) · Journal of Clinical Sleep Medicine · doi:10.5664/jcsm.4844 · Cited by 46
Self-citationAuto bi-level pressure relief–PAP is as effective as CPAP in OSA patients—a pilot study
Blau, A., Minx, M., Peter, J. G., Glos, M., Penzel, T., Baumann, G., & Fietze, I. (2012) · Sleep and Breathing · doi:10.1007/s11325-011-0574-1 · Cited by 32
Metadata
- Authors
- Abdenbi, F., Chambille, B., & Escourrou, P.
- Venue
- European Respiratory Journal
- Publisher
- European Respiratory Society (ERS)
- Published
- 2004-10
- Volume
- 24
- Issue
- 4
- Pages
- 649-658
- ISSN
- 0903-1936 (ISSN-L)
- 1399-3003
- OpenAlex
- W2111133132
- Cited by
- 49
- References
- 4
- FWCI
- 1.90
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Bench testing of auto-adjusting positive airway pressure devices. https://app.cochat.ai/papers/10.1183/09031936.04.00133703
- The paper
- Abdenbi, F., Chambille, B., & Escourrou, P. (2004). Bench testing of auto-adjusting positive airway pressure devices. European Respiratory Journal. https://doi.org/10.1183/09031936.04.00133703
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.