Lung deposition of budesonide inhaled via Turbuhaler: a comparison with terbutaline sulphate in normal subjects
Open accessThe DOI matches its Crossref record; 4 of the 4 references it cites were found in a registry or an index.
Abstract
We wanted to evaluate whether lung deposition of budesonide and terbutaline sulphate differs, and to determine lung deposition of budesonide inhaled at different peak inspiratory flows, through Turbuhaler. Lung deposition of budesonide, a lipophilic substance, and of terbutaline sulphate, a hydrophilic substance, was therefore compared, after administration via an inspiratory flow-driven, multi-dose, powder inhaler (Turbuhaler, Astra Draco AB) to 10 healthy volunteers. The radionuclide 99mTc was used to label drug particles, and radioactivity, indicating drug deposition, was measured using a gamma camera. Budesonide was inhaled at a normal flow of 58 l.min-1 and at a slow flow of 36 l-min-1. At the faster flow, a mean +/- SD 27.7 +/- 9.5% of the metered dose was deposited in the lung and at the slower flow 14.8 +/- 3.3% was deposited (p < 0.001). Mean lung deposition of terbutaline sulphate inhaled at 57 l.min-1 was 27.0 +/- 7.7%. We conclude that inspiratory flow has an important effect on lung deposition, but water solubility appears to have no effect.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Influence of inspiratory flow rate upon the effect of a Turbuhaler.
Pedersen, S. S., Hansen, O. R., & Fuglsang, G. (1990) · Archives of Disease in Childhood · doi:10.1136/adc.65.3.308 · Cited by 270
Terbutaline sulphate Turbuhaler: effect of inhaled flow rate on drug deposition and efficacy
Newman, S. P., Morén, F., Trofast, E., Talaee, N., & Clarke, S. W. (1991) · International Journal of Pharmaceutics · doi:10.1016/0378-5173(91)90239-k · Cited by 136
Self-citationThe adult patient’s difficulties with inhalers
Crompton, G. K. (1990) · Lung · doi:10.1007/bf02718191 · Cited by 86
Nasal distribution of budesonide inhaled via a powder inhaler.
Thorsson, L., Newman, S. P., Weisz, A., Trofast, E., & Morén, F. (1993) · PubMed · Cited by 49
Self-citation
Cited by
Efficacy and Safety of Inhaled Corticosteroids: New Developments
BARNES, P. J., PEDERSEN, S., & BUSSE, W. W. (1998) · American Journal of Respiratory and Critical Care Medicine · doi:10.1164/ajrccm.157.3.157315 · Cited by 749
Labiris, N. R., & Dolovich, M. B. (2003) · British Journal of Clinical Pharmacology · doi:10.1046/j.1365-2125.2003.01893.x · Cited by 451
Leach, C., Davidson, P., & Boudreau, R. (1998) · European Respiratory Journal · doi:10.1183/09031936.98.12061346 · Cited by 430
Inhaled Corticosteroids for Asthma Therapy
Cochrane, M. G., Bala, M. V., Downs, K. E., Mauskopf, J., & Ben-Joseph, R. H. (2000) · Chest · doi:10.1378/chest.117.2.542 · Cited by 428
Evolution of dry powder inhaler design, formulation, and performance
NEWMAN, S. P., & BUSSE, W. W. (2002) · Respiratory Medicine · doi:10.1053/rmed.2001.1276 · Cited by 340
Self-citationInhaler Errors in the CRITIKAL Study: Type, Frequency, and Association with Asthma Outcomes
Price, D. B., Román-Rodríguez, M., McQueen, R. B., Bosnic-Anticevich, S., Carter, V., Gruffydd-Jones, K., Haughney, J., Henrichsen, S., Hutton, C., Infantino, A., et al. (2017) · The Journal of Allergy and Clinical Immunology: In Practice · doi:10.1016/j.jaip.2017.01.004 · Cited by 327
Aging of the Respiratory System: Impact on Pulmonary Function Tests and Adaptation to Exertion
Janssens, J.-P. (2005) · Clinics in Chest Medicine · doi:10.1016/j.ccm.2005.05.004 · Cited by 262
Relevance of pharmacokinetics and pharmacodynamics of inhaled corticosteroids to asthma
Derendorf, H., Nave, R., Drollmann, A., Cerasoli, F., & Wurst, W. (2006) · European Respiratory Journal · doi:10.1183/09031936.00074905 · Cited by 253
Mechanisms of Pharmaceutical Aerosol Deposition in the Respiratory Tract
Cheng, Y. S. (2014) · AAPS PharmSciTech · doi:10.1208/s12249-014-0092-0 · Cited by 244
“DPIs including Spinhaler, Rotahaler, Diskhaler, and Turbuhaler use inspiratory flow to aerosolize the powder and the rotor, screen, or flow path to create turbulence in order to break up aggregates and reduce the particle size.”
InfluentialCan all patients with COPD use the correct inhalation flow with all inhalers and does training help?
Al-Showair, R. A. M., Tarsin, W. Y., Assi, K. H., Pearson, S. B., & Chrystyn, H. (2007) · Respiratory Medicine · doi:10.1016/j.rmed.2007.06.008 · Cited by 221
Inspiratory flow rates at different levels of resistance in elderly COPD patients
Janssens, W., VandenBrande, P., Hardeman, E., De Langhe, E., Philps, T., Troosters, T., & Decramer, M. (2008) · European Respiratory Journal · doi:10.1183/09031936.00024807 · Cited by 201
“Turbuhaler and Aeroliser are less effective at a PIF below 60 L/min whereas the Diskus seems to have an equal effect at a PIF between 30 and 60 L/min [6,22-30].”
BackgroundAirway deposition and airway effects of antiasthma drugs delivered from metered-dose inhalers
Pauwels, R., Newman, S., & Borgstrom, L. (1997) · European Respiratory Journal · doi:10.1183/09031936.97.10092127 · Cited by 198
“All currently available inhalers are flow-dependent; pMDIs should be used at a flow as low as possible [48– 50], and DPIs will deliver a larger pulmonary dose at a high inhalation flow than at a low flow [35, 51, 52].”
BackgroundSelf-citationChoosing inhaler devices for people with asthma: Current knowledge and outstanding research needs
Haughney, J., Price, D., Barnes, N. C., Virchow, J. C., Roche, N., & Chrystyn, H. (2010) · Respiratory Medicine · doi:10.1016/j.rmed.2010.04.012 · Cited by 190
“As a corollary, total lung deposition in vivo is greater with faster inhalation rates, although the fast inhalation required by DPIs results in substantial oropharyngeal deposition even at higher rates.(49,50) Combining all the information in Fig.”
Inhaled chemotherapy in lung cancer: future concept of nanomedicine
Zarogoulidis, P., Zarogoulidis, K., Domvri, Goldberg, Karamanos, Schmidt, & Chatzaki (2012) · International Journal of Nanomedicine · doi:10.2147/ijn.s29997 · Cited by 185
“112 This occurs due to different internal resistance to airflow and a range differentiation from low to high resistance.”
Pulmonary drug delivery by powder aerosols
Yang, M. Y., Chan, J. G. Y., & Chan, H.-K. (2014) · Journal of Controlled Release · doi:10.1016/j.jconrel.2014.04.055 · Cited by 169
The inhalers of the future? A review of dry powder devices on the market today
Smith, I. J., & Parry-Billings, M. (2003) · Pulmonary Pharmacology & Therapeutics · doi:10.1016/s1094-5539(02)00147-5 · Cited by 162
Metadata
- Authors
- Borgstrom, L., Bondesson, E., Moren, F., Trofast, E., & Newman, S.
- Venue
- European Respiratory Journal
- Publisher
- European Respiratory Society (ERS)
- Published
- 1994-01-01
- Volume
- 7
- Issue
- 1
- Pages
- 69-73
- ISSN
- 0903-1936 (ISSN-L)
- 1399-3003
- OpenAlex
- W2026766056
- Cited by
- 289
- References
- 4
- FWCI
- 12.95
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.