Patient compliance with inhaled medication: does combining beta-agonists with corticosteroids improve compliance?
Open accessThe DOI matches its Crossref record.
Abstract
Patient compliance with an inhaled corticosteroid may be greater if it is combined with a beta-agonist. This study compared compliance with an inhaled corticosteroid (budesonide), and a short-acting inhaled beta-agonist (terbutaline sulphate), and a Turbuhaler inhaler containing a combination of the two drugs. In an open, multicentre, parallel group study 102 asthmatic patients were randomly divided into two groups, either receiving the two drugs in separate Turbuhalers or combined into one Turbuhaler. A twice daily regimen was prescribed and a preweighed metered-dose inhaler (MDI) of salbutamol was provided for rescue use. Compliance was measured using the Turbuhaler Inhalation Computer (TIC), which recorded the time and date of each inhalation over a 12 week period. Forced expiratory volume in one second (FEV1) and forced vital capacity (FVC) measurements were carried out at week 0, 6 and 12. Results from 72 patients were analysed. The average compliance was 60-70%. Treatment was taken as prescribed on 30-40% of the study days, and over-usage occurred on less than 10% of days. Only 15% of patients took the drugs as prescribed for more than 80% of the days. Compliance was no greater in patients using the combined inhalers. Other ways of improving patient self-management need further investigation.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
British Guideline on the Management of Asthma
British Thoracic Society Scottish Intercollegiate Guidelines Network (2008) · Thorax · doi:10.1136/thx.2008.097741 · Cited by 2,021
Horne, R., & Weinman, J. (2002) · Psychology & Health · doi:10.1080/08870440290001502 · Cited by 869
Shared Treatment Decision Making Improves Adherence and Outcomes in Poorly Controlled Asthma
Wilson, S. R., Strub, P., Buist, A. S., Knowles, S. B., Lavori, P. W., Lapidus, J., & Vollmer, W. M. (2010) · American Journal of Respiratory and Critical Care Medicine · doi:10.1164/rccm.200906-0907oc · Cited by 671
Inhaled Corticosteroids for Asthma Therapy
Cochrane, M. G., Bala, M. V., Downs, K. E., Mauskopf, J., & Ben-Joseph, R. H. (2000) · Chest · doi:10.1378/chest.117.2.542 · Cited by 428
Medication adherence issues in patients treated for COPD
Restrepo, R. (2008) · International Journal of Chronic Obstructive Pulmonary Disease · doi:10.2147/copd.s3036 · Cited by 407
“During respiratory distress, approximately half of the patients report using more than the prescribed amount of medications (Dolce et al 1991; Bosley et al 1994).”
InfluentialErs Task Force on Difficult/therapy-Resistant Asthma, & Members of the Task Force: K.F. Chung and P. Godard (co-chairmen), E. A. (1999) · European Respiratory Journal · doi:10.1034/j.1399-3003.1999.13e43.x · Cited by 351
The psychological factors associated with poor compliance with treatment in asthma
Bosley, C., Fosbury, J., & Cochrane, G. (1995) · European Respiratory Journal · doi:10.1183/09031936.95.08060899 · Cited by 317
Self-citationPÉPIN, J. L., KRIEGER, J., RODENSTEIN, D., CORNETTE, A., SFORZA, E., DELGUSTE, P., DESCHAUX, C., GRILLIER, V., & LÉVY, P. (1999) · American Journal of Respiratory and Critical Care Medicine · doi:10.1164/ajrccm.160.4.9802027 · Cited by 274
Asthma: pathogenesis and novel drugs for treatment
Olin, J. T., & Wechsler, M. E. (2014) · BMJ · doi:10.1136/bmj.g5517 · Cited by 256
Cochrane, G. M., Horne, R., & Chanez, P. (1999) · Respiratory Medicine · doi:10.1016/s0954-6111(99)90260-3 · Cited by 246
Self-citationBarnes, P., & Woolcock, A. (1998) · European Respiratory Journal · doi:10.1183/09031936.98.12051209 · Cited by 225
“Poor adherence is surprisingly common, and a recent study that measured compliance with a computerized timing device in a dry-powder inhaler showed that only 18% of patients took inhaled corticosteroids as prescribed [13].”
BackgroundInterventions to improve adherence to inhaled steroids for asthma
Normansell, R., Kew, K. M., & Stovold, E. (2017) · Cochrane Database of Systematic Reviews · doi:10.1002/14651858.cd012226.pub2 · Cited by 176
Psychological factors associated with use of home nebulized therapy for COPD
Bosley, C., Corden, Z., Rees, P., & Cochrane, G. (1996) · European Respiratory Journal · doi:10.1183/09031936.96.09112346 · Cited by 104
Self-citationAdolescent Treatment Compliance in Asthma
Dinwiddie, R., & Müller, W. G. (2002) · Journal of the Royal Society of Medicine · doi:10.1258/jrsm.95.2.68 · Cited by 49
Metadata
- Authors
- Bosley, C., Parry, D., & Cochrane, G.
- Venue
- European Respiratory Journal
- Publisher
- European Respiratory Society (ERS)
- Published
- 1994-03-01
- Volume
- 7
- Issue
- 3
- Pages
- 504-509
- ISSN
- 0903-1936 (ISSN-L)
- 1399-3003
- OpenAlex
- W1964638867
- Cited by
- 111
- References
- 0
- FWCI
- 10.29
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.