Airway deposition and airway effects of antiasthma drugs delivered from metered-dose inhalers
Open accessThe DOI matches its Crossref record; 18 of the 18 references it cites were found in a registry or an index.
Abstract
Many different metered-dose inhalation devices are becoming available for the treatment of airway diseases. Each of these inhalers differs in its delivery characteristics. An assessment of the efficacy of drug delivery by these inhalers is essential, in view of their therapeutic use. A review of the literature on the relationship between airway deposition and airway effects of drugs delivered from metered-dose inhalers is presented. Nebulizers or spacers are not discussed. The effect of an inhaler depends on the characteristics of the inhaler and the inhalation manoeuvre performed by the patient. This review focuses on the influence of inhaler characteristics on the airway deposition and airway effects. Data from several studies show that there is a significant relationship between the amount of drug deposited in the airways and the airway effects of the drug. Studies on the relationship between airway deposition and airway effect have been troubled by methodological problems, such as the absence of multiple dose comparisons and the difficulty in obtaining steep dose-response curves. The techniques for measuring airway deposition of inhaled drugs, namely the scintigraphic and the pharmacokinetic method, are discussed and compared. The appropriate use of these techniques can help to define and compare the drug delivery characteristics of different devices, thus enabling inhaled therapy to be optimized.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
GLOBAL STRATEGY FOR ASTHMA MANAGEMENT AND PREVENTION
PAUWELS, R. A. (1996) · Arerugī/Arerugi · doi:10.15036/arerugi.45.792 · Cited by 9,994
Self-citationStahlhofen, W., Gebhart, J., & Heyder, J. (1980) · American Industrial Hygiene Association Journal · doi:10.1080/15298668091424933 · Cited by 444 · cited 1×
“Before inhalation, the drug must be aerosolized, as only very fine particles (below approximately 5 μm diameter) will reach the lower airways, and larger particles will to a great extent deposit in the oropharyngeal region before being swallowed [3].”
BackgroundThorsson, L., Edsbacker, S., & Conradson, T. (1994) · European Respiratory Journal · doi:10.1183/09031936.94.07101839 · Cited by 391 · cited 4×
“1** Terbutaline 58 21 [57] HV (n=8) Budesonide 58 28 [52] HV (n=10) 36 15 Budesonide 52 32 [41] HV (n=24) Diskhaler® Salbutamol - 12.”
BackgroundMethodInfluentialNewman, S. P., Weisz, A. W., Talaee, N., & Clarke, S. W. (1991) · Thorax · doi:10.1136/thx.46.10.712 · Cited by 326 · cited 2×
“A breath-actuated pMDI, which triggers the inhaler at a specific inhalation flow, and thus avoids the need to co-ordinate inhalation and actuation, has been tested in patients considered to be "good" and "bad "co-ordinators [63].”
Self-citationBorgstrom, L., Bondesson, E., Moren, F., Trofast, E., & Newman, S. (1994) · European Respiratory Journal · doi:10.1183/09031936.94.07010069 · Cited by 289 · cited 3×
“All currently available inhalers are flow-dependent; pMDIs should be used at a flow as low as possible [48– 50], and DPIs will deliver a larger pulmonary dose at a high inhalation flow than at a low flow [35, 51, 52].”
BackgroundSelf-citationInfluence of inspiratory flow rate upon the effect of a Turbuhaler.
Pedersen, S. S., Hansen, O. R., & Fuglsang, G. (1990) · Archives of Disease in Childhood · doi:10.1136/adc.65.3.308 · Cited by 270 · cited 1×
“25 mg terbutaline at 13, 22, 31 and 60 L·min-1 from Turbuhaler® [87].”
Dry Powder Aerosols I: A New Powder Inhalation Device
Bell, J. H., Hartley, P. S., & Cox, J. S. G. (1971) · Journal of Pharmaceutical Sciences · doi:10.1002/jps.2600601028 · Cited by 202
Effects of various inhalation modes on the deposition of radioactive pressurized aerosols.
Newman, S. P., Pavia, D., GARLAND, N., & Clarke, S. W. (1982) · PubMed · Cited by 172
Self-citationA technique for the absolute measurement of activity using a gamma camera and computer
Fleming, J. S. (1979) · Physics in Medicine and Biology · doi:10.1088/0031-9155/24/1/017 · Cited by 166
Pressurised aerosol deposition in the human lung with and without an "open" spacer device.
Newman, S. P., Clark, A. R., Talaee, N., & Clarke, S. W. (1989) · Thorax · doi:10.1136/thx.44.9.706 · Cited by 153 · cited 1×
“regional deposition data; the most usual divisions of the lungs are into central, intermediate and peripheral zones, representing mainly large, medium and small airways, respectively [19], or into a central one-third and a peripheral two-thirds of the lung fields [20].”
BackgroundSelf-citation
Cited by
What the pulmonary specialist should know about the new inhalation therapies
Laube, B. L., Janssens, H. M., de Jongh, F. H. C., Devadason, S. G., Dhand, R., Diot, P., Everard, M. L., Horvath, I., Navalesi, P., Voshaar, T., et al. (2011) · European Respiratory Journal · doi:10.1183/09031936.00166410 · Cited by 806
Physiological changes in respiratory function associated with ageing
Janssens, J.-P., Pache, J. C., & Nicod, L. P. (1999) · European Respiratory Journal · doi:10.1034/j.1399-3003.1999.13a36.x · Cited by 801
Nanoparticles for drug delivery to the lungs
Sung, J. C., Pulliam, B. L., & Edwards, D. A. (2007) · Trends in Biotechnology · doi:10.1016/j.tibtech.2007.09.005 · Cited by 643
Regional Lung Deposition and Bronchodilator Response as a Function of β 2 -Agonist Particle Size
Usmani, O. S., Biddiscombe, M. F., & Barnes, P. J. (2005) · American Journal of Respiratory and Critical Care Medicine · doi:10.1164/rccm.200410-1414oc · Cited by 578
Evolution of dry powder inhaler design, formulation, and performance
NEWMAN, S. P., & BUSSE, W. W. (2002) · Respiratory Medicine · doi:10.1053/rmed.2001.1276 · Cited by 340
Self-citationDry powder inhalation: past, present and future
de Boer, A. H., Hagedoorn, P., Hoppentocht, M., Buttini, F., Grasmeijer, F., & Frijlink, H. W. (2017) · Expert Opinion on Drug Delivery · doi:10.1080/17425247.2016.1224846 · Cited by 271
Aging of the Respiratory System: Impact on Pulmonary Function Tests and Adaptation to Exertion
Janssens, J.-P. (2005) · Clinics in Chest Medicine · doi:10.1016/j.ccm.2005.05.004 · Cited by 262
Dry powder inhalers for pulmonary drug delivery
Frijlink, H. W., & De Boer, A. H. (2004) · Expert Opinion on Drug Delivery · doi:10.1517/17425247.1.1.67 · Cited by 259
Can all patients with COPD use the correct inhalation flow with all inhalers and does training help?
Al-Showair, R. A. M., Tarsin, W. Y., Assi, K. H., Pearson, S. B., & Chrystyn, H. (2007) · Respiratory Medicine · doi:10.1016/j.rmed.2007.06.008 · Cited by 221
Choosing inhaler devices for people with asthma: Current knowledge and outstanding research needs
Haughney, J., Price, D., Barnes, N. C., Virchow, J. C., Roche, N., & Chrystyn, H. (2010) · Respiratory Medicine · doi:10.1016/j.rmed.2010.04.012 · Cited by 190
The inhalers of the future? A review of dry powder devices on the market today
Smith, I. J., & Parry-Billings, M. (2003) · Pulmonary Pharmacology & Therapeutics · doi:10.1016/s1094-5539(02)00147-5 · Cited by 162
Metadata
- Authors
- Pauwels, R., Newman, S., & Borgstrom, L.
- Venue
- European Respiratory Journal
- Publisher
- European Respiratory Society (ERS)
- Published
- 1997-09-01
- Volume
- 10
- Issue
- 9
- Pages
- 2127-2138
- ISSN
- 0903-1936 (ISSN-L)
- 1399-3003
- OpenAlex
- W2163347392
- Cited by
- 198
- References
- 18
- FWCI
- 9.07
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.