de Vries, Rianne, Dagelet, Yennece W.F., Spoor, Pien, Snoey, Erik, Jak, Patrick M.C., Brinkman, Paul, Dijkers, Erica, Bootsma, Simon K., Elskamp, Fred, de Jongh, Frans H.C., Haarman, Eric G., in ‘t Veen, Johannes C.C.M, Maitland-van der Zee, Anke-Hilse, Sterk, Peter J. · 2018 · European Respiratory Journal
Cited by 143

The DOI matches its Crossref record; 3 of the 3 references it cites were found in a registry or an index.

Abstract

Asthma and chronic obstructive pulmonary disease (COPD) are complex and overlapping diseases that include inflammatory phenotypes. Novel anti-eosinophilic/anti-neutrophilic strategies demand rapid inflammatory phenotyping, which might be accessible from exhaled breath. Our objective was to capture clinical/inflammatory phenotypes in patients with chronic airway disease using an electronic nose (eNose) in a training and validation set. This was a multicentre cross-sectional study in which exhaled breath from asthma and COPD patients (n=435; training n=321 and validation n=114) was analysed using eNose technology. Data analysis involved signal processing and statistics based on principal component analysis followed by unsupervised cluster analysis and supervised linear regression. Clustering based on eNose resulted in five significant combined asthma and COPD clusters that differed regarding ethnicity (p=0.01), systemic eosinophilia (p=0.02) and neutrophilia (p=0.03), body mass index (p=0.04), exhaled nitric oxide fraction (p<0.01), atopy (p<0.01) and exacerbation rate (p<0.01). Significant regression models were found for the prediction of eosinophilic (R 2=0.581) and neutrophilic (R 2=0.409) blood counts based on eNose. Similar clusters and regression results were obtained in the validation set. Phenotyping a combined sample of asthma and COPD patients using eNose provides validated clusters that are not determined by diagnosis, but rather by clinical/inflammatory characteristics. eNose identified systemic neutrophilia and/or eosinophilia in a dose-dependent manner.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1183/13993003.01817-2017

Cites

3 of 3 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 3 references

Cited by

Metadata

Authors
de Vries, R., Dagelet, Y. W. F., Spoor, P., Snoey, E., Jak, P. M. C., Brinkman, P., Dijkers, E., Bootsma, S. K., Elskamp, F., de Jongh, F. H. C., Haarman, E. G., in ‘t Veen, J. C. C. M., Maitland-van der Zee, A.-H., & Sterk, P. J.
Venue
European Respiratory Journal
Published
2018-01
Volume
51
Issue
1
Pages
1701817
ISSN
  • 0903-1936 (ISSN-L)
  • 1399-3003
OpenAlex
W2783480163
Cited by
143
References
3
FWCI
7.46
Type
journal article
Language
en
Open access
green

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.