Comparative glycemic control, safety and patient ratings for a new 4 mm × 32G insulin pen needle in adults with diabetes
The DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.
Abstract
OBJECTIVE: Pen needles (PN) for subcutaneous insulin therapy have become smaller; 5 mm PNs are now the shortest in use. We evaluated the safety, efficacy and patient ratings of a new 4 mm x 32 gauge (G) PN. RESEARCH DESIGN AND METHODS: Subjects with type 1 and type 2 diabetes and HbA1c 5.5% to 9.5% participated in a randomized non-inferiority cross-over trial, at four U.S. centers. Subjects used 4 mm x 32G PNs and either 5 mm x 31G PNs (4/5 mm) or 8 mm x 31G PNs (4/8 mm) in two, 3-week treatment periods; order of needle use was controlled. Subjects were either 'low dose' or 'regular dose' users (highest single insulin dose <or= 20 units and 21-40 units, respectively). Percent absolute change in serum fructosamine (% |Delta Fru|) was the primary endpoint; unexplained, severe hypo- or hyperglycemia was a secondary measure. Leakage at injection sites and pain measured by visual analog scale were tertiary measures. Equivalent glycemic control was defined á priori as % |Delta Fru| (including 95% CI) within 20%; 40 subjects per subgroup provides 90% power at alpha = 0.05. CLINICAL TRIAL REGISTRATION: The study was registered on clinicaltrials.gov (identifier: NCT00928057). RESULTS: Of 173 subjects randomized, 168 completed the study, and 163 were included in the fructosamine analyses--83 and 80 in the 4/5 mm and 4/8 mm groups, respectively. Subjects were 56% male, mean 52.6 yrs, 63% type 2. Baseline HbA1c = 7.5 +/- 1.0% and fructosamine 301 +/- 55.1 micromol/L. Mean % |Delta Fru| was 4.9% (95% CI 3.8, 6.0) and 5.5% (4.5, 6.4), respectively, for the 4/5 mm and 4/8 mm groups, meeting glycemic equivalence criteria; results were similar in both dose groups. The median |Delta Fru| was 11.0 micromol/L (8.0, 13.0) and 13.5 micromol/L (9.8, 18.0) for the 4/5 mm and 4/8 mm groups, respectively. Unexplained, severe hypo- and hyperglycemic episodes were infrequent and not different between PNs. The 4 mm PN was rated significantly less painful and preferred by approximately 2/3 of subjects (p < 0.01). All three PNs had similar reported injection site leakage. LIMITATIONS: The study was of relatively short duration, in adults in the U.S. Further trials in other patients (e.g., GLP-1 users, pediatrics, obese) should be performed. CONCLUSIONS: The 4 mm x 32G PN provided equivalent glycemic control compared to 31G, 5 mm and 8 mm PNs with reduced pain, no difference in insulin leakage and was preferred by patients.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Gibney, M. A., Arce, C. H., Byron, K. J., & Hirsch, L. J. (2010) · Current Medical Research and Opinion · doi:10.1185/03007995.2010.481203 · Cited by 283
Self-citationLaurent, A., Mistretta, F., Bottigioli, D., Dahel, K., Goujon, C., Nicolas, J. F., Hennino, A., & Laurent, P. E. (2007) · Vaccine · doi:10.1016/j.vaccine.2007.05.046 · Cited by 235
Cited by
9. Pharmacologic Approaches to Glycemic Treatment: Standards of Medical Care in Diabetes—2019
American Diabetes Association (2019) · Diabetes Care · doi:10.2337/dc19-s009 · Cited by 739
Glucagon-Like Peptide 1 Receptor Agonists for Type 2 Diabetes
Hinnen, D. (2017) · Diabetes Spectrum · doi:10.2337/ds16-0026 · Cited by 394
New insulin delivery recommendations
Frid, A. H., Kreugel, G., Grassi, G., Halimi, S., Hicks, D., Hirsch, L. J., Smith, M. J., Wellhoener, R., Bode, B. W., Hirsch, I. B., et al. (2016) · Mayo Clinic Proceedings · doi:10.1016/j.mayocp.2016.06.010 · Cited by 286
Self-citationGibney, M. A., Arce, C. H., Byron, K. J., & Hirsch, L. J. (2010) · Current Medical Research and Opinion · doi:10.1185/03007995.2010.481203 · Cited by 283
Self-citationHirsch, L., Gibney, M., Berube, J., & Manocchio, J. (2012) · Journal of Diabetes Science and Technology · doi:10.1177/193229681200600216 · Cited by 96
Self-citation
Metadata
- Authors
- Hirsch, L. J., Gibney, M. A., Albanese, J., Qu, S., Kassler-Taub, K., Klaff, L. J., & Bailey, T. S.
- Venue
- Current Medical Research and Opinion
- Publisher
- Informa Healthcare
- Published
- 2010-05-04
- Volume
- 26
- Issue
- 6
- Pages
- 1531-1541
- ISSN
- 0300-7995 (ISSN-L)
- 1473-4877
- OpenAlex
- W2020272422
- Cited by
- 109
- References
- 2
- FWCI
- 6.60
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.