Lung ultrasound for the diagnosis of pneumonia in adults: a systematic review and meta-analysis
Open accessThe DOI matches its Crossref record; 33 of the 33 references it cites were found in a registry or an index.
Abstract
BACKGROUND: Guidelines do not currently recommend the use of lung ultrasound (LUS) as an alternative to chest X-ray (CXR) or chest computerized tomography (CT) scan for the diagnosis of pneumonia. We conducted a meta-analysis to summarize existing evidence of the diagnostic accuracy of LUS for pneumonia in adults. METHODS: We conducted a systematic search of published studies comparing the diagnostic accuracy of LUS against a referent CXR or chest CT scan and/or clinical criteria for pneumonia in adults aged ≥18 years. Eligible studies were required to have a CXR and/or chest CT scan at the time of evaluation. We manually extracted descriptive and quantitative information from eligible studies, and calculated pooled sensitivity and specificity using the Mantel-Haenszel method and pooled positive and negative likelihood ratios (LR) using the DerSimonian-Laird method. We assessed for heterogeneity using the Q and I2 statistics. RESULTS: Our initial search strategy yielded 2726 articles, of which 45 (1.7%) were manually selected for review and 10 (0.4%) were eligible for analyses. These 10 studies provided a combined sample size of 1172 participants. Six studies enrolled adult patients who were either hospitalized or admitted to Emergency Departments with suspicion of pneumonia and 4 studies enrolled critically-ill adult patients. LUS was performed by highly-skilled sonographers in seven studies, by trained physicians in two, and one did not mention level of training. All studies were conducted in high-income settings. LUS took a maximum of 13 minutes to conduct. Nine studies used a 3.5-5 MHz micro-convex transducer and one used a 5-9 MHz convex probe. Pooled sensitivity and specificity for the diagnosis of pneumonia using LUS were 94% (95% CI, 92%-96%) and 96% (94%-97%), respectively; pooled positive and negative LRs were 16.8 (7.7-37.0) and 0.07 (0.05-0.10), respectively; and, the area-under-the-ROC curve was 0.99 (0.98-0.99). CONCLUSIONS: Our meta-analysis supports that LUS, when conducted by highly-skilled sonographers, performs well for the diagnosis of pneumonia. General practitioners and Emergency Medicine physicians should be encouraged to learn LUS since it appears to be an established diagnostic tool in the hands of experienced physicians.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Measuring inconsistency in meta-analyses
Higgins, J. P. T., Thompson, S. G., Deeks, J. J., & Altman, D. G. (2003) · BMJ · doi:10.1136/bmj.327.7414.557 · Cited by 63,139
Meta-analysis in clinical trials
DerSimonian, R., & Laird, N. (1986) · Controlled Clinical Trials · doi:10.1016/0197-2456(86)90046-2 · Cited by 39,552
Statistical Aspects of the Analysis of Data From Retrospective Studies of Disease
(1959) · JNCI: Journal of the National Cancer Institute · doi:10.1093/jnci/22.4.719 · Cited by 14,689 · cited 1×
“The primary objective was to estimate pooled measurements of diagnostic accuracy: pooled sensitivity and specificity using the Mantel-Haenszel method [27], and pooled positive and negative likelihood ratios (LR) using the DerSimonian-Laird method [28].”
MethodQUADAS-2: a revised tool for the quality assessment of diagnostic accuracy studies
Whiting, P. F., Rutjes, A. W. S., Westwood, M. E., Mallett, S., Deeks, J. J., Reitsma, J. B., Leeflang, M. M. G., Sterne, J. A. C., Bossuyt, P. M. M., & the QUADAS-2 Group* (2011) · Annals of Internal Medicine · doi:10.7326/0003-4819-155-8-201110180-00009 · Cited by 14,199
Murray, C. J. L., Vos, T., Lozano, R., Naghavi, M., Flaxman, A. D., Michaud, C., Ezzati, M., Shibuya, K., Salomon, J. A., Abdalla, S., et al. (2012) · The Lancet · doi:10.1016/s0140-6736(12)61689-4 · Cited by 8,888
Computed Tomography — An Increasing Source of Radiation Exposure
Brenner, D. J., & Hall, E. J. (2007) · New England Journal of Medicine · doi:10.1056/nejmra072149 · Cited by 8,748
Mandell, L. A., Wunderink, R. G., Anzueto, A., Bartlett, J. G., Campbell, G. D., Dean, N. C., Dowell, S. F., File, T. M., Musher, D. M., Niederman, M. S., et al. (2007) · Clinical Infectious Diseases · doi:10.1086/511159 · Cited by 6,202
International Study of the Prevalence and Outcomes of Infection in Intensive Care Units
Vincent, J.-L. (2009) · JAMA · doi:10.1001/jama.2009.1754 · Cited by 3,618
International evidence-based recommendations for point-of-care lung ultrasound
International Liaison Committee on Lung Ultrasound (ILC-LUS) for the International Consensus Conference on Lung Ultrasound (ICC-LUS), Volpicelli, G., Elbarbary, M., Blaivas, M., Lichtenstein, D. A., Mathis, G., Kirkpatrick, A. W., Melniker, L., Gargani, L., Noble, V. E., et al. (2012) · Intensive Care Medicine · doi:10.1007/s00134-012-2513-4 · Cited by 2,874
Relevance of Lung Ultrasound in the Diagnosis of Acute Respiratory Failure*: The BLUE Protocol
Lichtenstein, D. A., & Mezière, G. A. (2008) · Chest · doi:10.1378/chest.07-2800 · Cited by 2,068
Cited by
Prina, E., Ranzani, O. T., & Torres, A. (2015) · The Lancet · doi:10.1016/s0140-6736(15)60733-4 · Cited by 516
Lung Ultrasound for the Diagnosis of Pneumonia in Children: A Meta-analysis
Pereda, M. A., Chavez, M. A., Hooper-Miele, C. C., Gilman, R. H., Steinhoff, M. C., Ellington, L. E., Gross, M., Price, C., Tielsch, J. M., & Checkley, W. (2015) · Pediatrics · doi:10.1542/peds.2014-2833 · Cited by 480
Self-citationSmith, C. J., Kishore, A. K., Vail, A., Chamorro, A., Garau, J., Hopkins, S. J., Di Napoli, M., Kalra, L., Langhorne, P., Montaner, J., et al. (2015) · Stroke · doi:10.1161/strokeaha.115.009617 · Cited by 452
New International Guidelines and Consensus on the Use of Lung Ultrasound
Demi, L., Wolfram, F., Klersy, C., De Silvestri, A., Ferretti, V. V., Muller, M., Miller, D., Feletti, F., Wełnicki, M., Buda, N., et al. (2023) · Journal of Ultrasound in Medicine · doi:10.1002/jum.16088 · Cited by 328
Maw, A. M., Hassanin, A., Ho, P. M., McInnes, M. D. F., Moss, A., Juarez-Colunga, E., Soni, N. J., Miglioranza, M. H., Platz, E., DeSanto, K., et al. (2019) · JAMA Network Open · doi:10.1001/jamanetworkopen.2019.0703 · Cited by 309
Aliberti, S., Dela Cruz, C. S., Amati, F., Sotgiu, G., & Restrepo, M. I. (2021) · The Lancet · doi:10.1016/s0140-6736(21)00630-9 · Cited by 305
Point-of-Care Ultrasound in General Practice: A Systematic Review
Andersen, C. A., Holden, S., Vela, J., Rathleff, M. S., & Jensen, M. B. (2019) · The Annals of Family Medicine · doi:10.1370/afm.2330 · Cited by 303
Streptococcus pneumoniae’s Virulence and Host Immunity: Aging, Diagnostics, and Prevention
Brooks, L. R. K., & Mias, G. I. (2018) · Frontiers in Immunology · doi:10.3389/fimmu.2018.01366 · Cited by 286
Ye, X., Xiao, H., Chen, B., & Zhang, S. (2015) · PLOS ONE · doi:10.1371/journal.pone.0130066 · Cited by 261
Point-of-Care Ultrasonography for Primary Care Physicians and General Internists
Bhagra, A., Tierney, D. M., Sekiguchi, H., & Soni, N. J. (2016) · Mayo Clinic Proceedings · doi:10.1016/j.mayocp.2016.08.023 · Cited by 244
Pan, F., Yang, L., Li, Y., Liang, B., Li, L., Ye, T., Li, L., Liu, D., Gui, S., Hu, Y., et al. (2020) · International Journal of Medical Sciences · doi:10.7150/ijms.46614 · Cited by 237
“From the previous studies, lung ultrasound could also be performed at the bedside and has been used in diagnosing and monitoring pneumonia with higher sensitivity and specificity (≥94%) than DR but without X-ray exposure [25, 26].”
BackgroundLung Ultrasound for the Cardiologist
Picano, E., Scali, M. C., Ciampi, Q., & Lichtenstein, D. (2018) · JACC: Cardiovascular Imaging · doi:10.1016/j.jcmg.2018.06.023 · Cited by 224
Nazerian, P., Volpicelli, G., Vanni, S., Gigli, C., Betti, L., Bartolucci, M., Zanobetti, M., Ermini, F. R., Iannello, C., & Grifoni, S. (2015) · The American Journal of Emergency Medicine · doi:10.1016/j.ajem.2015.01.035 · Cited by 213
Point-of-care ultrasound (POCUS): unnecessary gadgetry or evidence-based medicine?
Smallwood, N., & Dachsel, M. (2018) · Clinical Medicine · doi:10.7861/clinmedicine.18-3-219 · Cited by 186
Lung Ultrasonography for the Assessment of Perioperative Atelectasis: A Pilot Feasibility Study
Monastesse, A., Girard, F., Massicotte, N., Chartrand-Lefebvre, C., & Girard, M. (2017) · Anesthesia & Analgesia · doi:10.1213/ane.0000000000001603 · Cited by 181
Staub, L. J., Mazzali Biscaro, R. R., Kaszubowski, E., & Maurici, R. (2019) · The Journal of Emergency Medicine · doi:10.1016/j.jemermed.2018.09.009 · Cited by 179
Alzahrani, S. A., Al-Salamah, M. A., Al-Madani, W. H., & Elbarbary, M. A. (2017) · Critical Ultrasound Journal · doi:10.1186/s13089-017-0059-y · Cited by 172
“In comparison with previous systematic review published addressing this issue [4, 42], our study included more primary studies and subjects compared to previously published systematic reviews.”
BackgroundMethodResultInfluentialLung ultrasound for the diagnosis of pneumonia in adults: A meta-analysis
Long, L., Zhao, H.-T., Zhang, Z.-Y., Wang, G.-Y., & Zhao, H.-L. (2017) · Medicine · doi:10.1097/md.0000000000005713 · Cited by 169
Ventilator-associated pneumonia: pathobiological heterogeneity and diagnostic challenges
Howroyd, F., Chacko, C., MacDuff, A., Gautam, N., Pouchet, B., Tunnicliffe, B., Weblin, J., Gao-Smith, F., Ahmed, Z., Duggal, N. A., et al. (2024) · Nature Communications · doi:10.1038/s41467-024-50805-z · Cited by 162
“CXR provides an isolated, two-dimensional image of a complex three-dimensional structure in which several tissues overlay one another, making interpretation challenging 96,97 .”
BackgroundAccelerating Detection of Lung Pathologies with Explainable Ultrasound Image Analysis
Born, J., Wiedemann, N., Cossio, M., Buhre, C., Brändle, G., Leidermann, K., Goulet, J., Aujayeb, A., Moor, M., Rieck, B., et al. (2021) · Applied Sciences · doi:10.3390/app11020672 · Cited by 161
“Over the last two decades, ultrasound became an established tool to diagnose pulmonary diseases [14, 30, 36], has been forecast to replace radiographic techniques [9], was demonstrated to be superior to CXR for pulmonary diseases [15, 38], and started to replace X-Ray as first-line examination [1, 10].”
BackgroundBerman, J., Masseau, I., Fecteau, G., Buczinski, S., & Francoz, D. (2020) · Preventive Veterinary Medicine · doi:10.1016/j.prevetmed.2020.105153 · Cited by 20
Metadata
- Authors
- Chavez, M. A., Shams, N., Ellington, L. E., Naithani, N., Gilman, R. H., Steinhoff, M. C., Santosham, M., Black, R. E., Price, C., Gross, M., & Checkley, W.
- Venue
- Respiratory Research
- Published
- 2014-04-23
- Volume
- 15
- Issue
- 1
- Pages
- 50-50
- ISSN
- 1465-9921 (ISSN-L)
- 1465-993X
- OpenAlex
- W2128328029
- Cited by
- 427
- References
- 33
- FWCI
- 5.08
- Type
- journal article
- Language
- en
- Open access
- gold
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.