Decon2LS: An open-source software package for automated processing and visualization of high resolution mass spectrometry data
Open accessThe DOI matches its Crossref record; 28 of the 28 references it cites were found in a registry or an index.
Abstract
Background: Data generated from liquid chromatography coupled to high-resolution mass spectrometry (LC-MS)-based studies of a biological sample can contain large amounts of biologically significant information in the form of proteins, peptides, and metabolites. Interpreting this data involves inferring the masses and abundances of biomolecules injected into the instrument. Because of the inherent complexity of mass spectral patterns produced by these biomolecules, the analysis is significantly enhanced by using visualization capabilities to inspect and confirm results. In this paper we describe Decon2LS, an open-source software package for automated processing and visualization of high-resolution MS data. Drawing extensively on algorithms developed over the last ten years for ICR2LS, Decon2LS packages the algorithms as a rich set of modular, reusable processing classes for performing diverse functions such as reading raw data, routine peak finding, theoretical isotope distribution modelling, and deisotoping. Because the source code is openly available, these functionalities can now be used to build derivative applications in relatively fast manner. In addition, Decon2LS provides an extensive set of visualization tools, such as high performance chart controls. Results: With a variety of options that include peak processing, deisotoping, isotope composition, etc, Decon2LS supports processing of multiple raw data formats. Deisotoping can be performed on an individual scan, an individual dataset, or on multiple datasets using batch processing. Other processing options include creating a two dimensional view of mass and liquid chromatography (LC) elution time features, generating spectrum files for tandem MS data, creating total intensity chromatograms, and visualizing theoretical peptide profiles. Application of Decon2LS to deisotope different datasets obtained across different instruments yielded a high number of features that can be used to identify and quantify peptides in the biological sample. Conclusion: Decon2LS is an efficient software package for discovering and visualizing features in proteomics studies that require automated interpretation of mass spectra. Besides being easy to use, fast, and reliable, Decon2LS is also open-source, which allows developers in the proteomics and bioinformatics communities to reuse and refine the algorithms to meet individual needs. Decon2LS source code, installer, and tutorials may be downloaded free of charge at http://http:/ncrr.pnl.gov/software/.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Figures







Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
The cited source says what the claim attributes to it.
In the citing paper
“Importing data obtained from different MS instruments is supported using ProteoWizard,12 DeconEngine,13 and vendor provided libraries.”
From MASH Explorer: A Universal Software Environment for Top-Down Proteomics (2020) · cites this paper as [13]
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Eng, J. K., McCormack, A. L., & Yates, J. R. (1994) · Journal of the American Society for Mass Spectrometry · doi:10.1016/1044-0305(94)80016-2 · Cited by 6,484 · cited 1×
“These files can be processed using search-engines such as SEQUEST[22] to identify peptides.”
MethodSmith, C. A., Want, E. J., O'Maille, G., Abagyan, R., & Siuzdak, G. (2006) · Analytical Chemistry · doi:10.1021/ac051437y · Cited by 5,262 · cited 1×
“While XCMS [13] is useful for data pre-processing, peak-detection, retention-time alignment and peak matching across samples, this algorithm also does not perform deisotoping. msInspect [14] is an analysis package for deisotoping high-resolution LC-MS data in mzXML format in sequential steps.”
MethodOpenMS – An open-source software framework for mass spectrometry
Sturm, M., Bertsch, A., Gröpl, C., Hildebrandt, A., Hussong, R., Lange, E., Pfeifer, N., Schulz-Trieglaff, O., Zerck, A., Reinert, K., et al. (2008) · BMC Bioinformatics · doi:10.1186/1471-2105-9-163 · Cited by 644
Interpreting mass spectra of multiply charged ions
Mann, M., Meng, C. K., & Fenn, J. B. (1989) · Analytical Chemistry · doi:10.1021/ac00190a023 · Cited by 588 · cited 1×
“Several deisotoping and visualization algorithms have been described in the literature [3-9] and are available as part of commercial vendor packages such as XCalibur (Thermo Fisher), MassHunter (Agilent) and Elucidator System (Rosetta Biosoftware).”
MethodZhang, Z., & Marshall, A. G. (1998) · Journal of the American Society for Mass Spectrometry · doi:10.1016/s1044-0305(97)00284-5 · Cited by 509 · cited 1×
“Several deisotoping and visualization algorithms have been described in the literature [3-9] and are available as part of commercial vendor packages such as XCalibur (Thermo Fisher), MassHunter (Agilent) and Elucidator System (Rosetta Biosoftware).”
MethodAutomated reduction and interpretation of
Horn, D. M., Zubarev, R. A., & McLafferty, F. W. (2000) · Journal of the American Society for Mass Spectrometry · doi:10.1016/s1044-0305(99)00157-9 · Cited by 507
Senko, M. W., Beu, S. C., & McLaffertycor, F. W. (1995) · Journal of the American Society for Mass Spectrometry · doi:10.1016/1044-0305(95)00017-8 · Cited by 451 · cited 2×
“The most likely empirical composition is determined using the average mass determined in step 2 and the Averagine algorithm [17], which assumes an empirical composition that is equal to the average composition of all the peptides in a protein FASTA file.”
MethodAn accurate mass tag strategy for quantitative and high-throughput proteome measurements
Smith, R. D., Anderson, G. A., Lipton, M. S., Pasa-Tolic, L., Shen, Y., Conrads, T. P., Veenstra, T. D., & Udseth, H. R. (2002) · PROTEOMICS · doi:10.1002/1615-9861(200205)2:5<513::aid-prot513>3.0.co;2-w · Cited by 432 · cited 2×
“tides in a database constructed from previous LC-MS/MS analyses [20].”
MethodSelf-citationBellew, M., Coram, M., Fitzgibbon, M., Igra, M., Randolph, T., Wang, P., May, D., Eng, J., Fang, R., Lin, C., et al. (2006) · Bioinformatics · doi:10.1093/bioinformatics/btl276 · Cited by 265 · cited 1×
“msInspect [14] is an analysis package for deisotoping high-resolution LC-MS data in mzXML format in sequential steps.”
MethodSenko, M. W., Canterbury, J. D., Guan, S., & Marshall, A. G. (1996) · Rapid Communications in Mass Spectrometry · doi:10.1002/(sici)1097-0231(199611)10:14<1839::aid-rcm718>3.0.co;2-v · Cited by 259 · cited 1×
“While a functional application of THRASH was not provided by its developers, the algorithm was reportedly incorporated into the MIDAS [18] data system.”
Method
Cited by
Items 101–200 of 221
Rosenberg, J. A., Parker, W. R., Cammarata, M. B., & Brodbelt, J. S. (2018) · Journal of the American Society for Mass Spectrometry · doi:10.1007/s13361-018-1918-x · Cited by 25
“Each fitting is assigned a score based on the peak-fit function [17].”
Isanapong, J., Hambright, W. S., Willis, A. G., Boonmee, A., Callister, S., Burnum-Johnson, K., Paša‐Tolić, L., Nicora, C., Wertz, J. T., Schmidt, T. M., et al. (2013) · The ISME Journal · doi:10.1038/ismej.2013.74 · Cited by 28
“Liquid chromatography (LC)-MS spectra were de-isotoped (Jaitly et al., 2009), mass and elution time features identified, then matched (Monroe et al.”
MethodBryant, A. E., Aldape, M. J., Bayer, C. R., Katahira, E. J., Bond, L., Nicora, C., Fillmore, T., Clauss, T. R., Metz, T., Webb‐Robertson, B., et al. (2017) · PLoS ONE · doi:10.1371/journal.pone.0172486 · Cited by 25
“…times (NETs) of peptides detected in the individual samples were matched against the entries in the AMT tag database using the PRISM Data Analysis system [28], which is a series of software tools developed in-house (e.g. Decon2LS [29] and VIPER [30]) and freely available at omics.pnl.gov/software.”
Visualization of high resolution spatial mass spectrometric data during acquisition
Thomas, M., Heath, B. S., Laskin, J., Li, D., Liu, E., Hui, K., Kuprat, A. P., van Dam, K. K., & Carson, J. P. (2012) · Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC) · doi:10.1109/embc.2012.6347250 · Cited by 23
Zhang, H., Brown, R. N., Qian, W., Monroe, M. E., Purvine, S. O., Moore, R., Gritsenko, M. A., Shi, L., Romine, M. F., Fredrickson, J. K., et al. (2010) · Journal of Proteome Research · doi:10.1021/pr9009113 · Cited by 24
Self-citationAutomated Data Extraction from In Situ Protein-Stable Isotope Probing Studies
Slysz, G., Steinke, L., Ward, D. M., Klatt, C. G., Clauss, T. R., Purvine, S. O., Payne, S., Anderson, G., Smith, R. D., & Lipton, M. S. W. (2014) · Journal of Proteome Research · doi:10.1021/pr400633j · Cited by 22
Self-citationIdentification of Peptide Features in Precursor Spectra Using Hardklör and Krönik
Hoopmann, M. R., MacCoss, M. J., & Moritz, R. L. (2012) · Current Protocols in Bioinformatics · doi:10.1002/0471250953.bi1318s37 · Cited by 26
“Other algorithms have since followed that improve upon these algorithms through variations in modeling (Kaur and O'Connor, 2006; Jaitly et al., 2009) or deconvolution strategies (Du and Angeletti, 2006; Renard et al. 2008).”
MethodMultipurpose Dissociation Cell for Enhanced ETD of Intact Protein Species
Rose, C. M., Russell, J. D., Ledvina, A. R., McAlister, G. C., Westphall, M. S., Griep‐Raming, J., Schwartz, J. C., Coon, J. J., & Syka, J. E. P. (2013) · Journal of the American Society for Mass Spectrometry · doi:10.1007/s13361-013-0622-0 · Cited by 21
A Partial Set Covering Model for Protein Mixture Identification Using Mass Spectrometry Data
He, Z., Yang, C., & Yu, W. (2009) · IEEE Transactions on Computational Biology and Bioinformatics · doi:10.1109/tcbb.2009.54 · Cited by 21
“To extract single-stage MS peaks, we use the Decon2LS software [42] and VIPER software [43] to preprocess the raw LC-MS data with their default parameter settings.”
MethodTop-down protein identification using isotopic envelope fingerprinting
Xiao, K., Yu, F., & Tian, Z. (2016) · Journal of Proteomics · doi:10.1016/j.jprot.2016.10.010 · Cited by 22
Kedia, K., Wendler, J., Baker, E. S., Burnum-Johnson, K., Jarlsberg, L. G., Stratton, K. G., Wright, A., Piehowski, P., Gritsenko, M. A., Lewinsohn, D. M., et al. (2018) · Tuberculosis · doi:10.1016/j.tube.2018.07.005 · Cited by 24
Self-citationProteomic assessment of serum biomarkers of longevity in older men
ORWOLL, E. S., Wiedrick, J. T., Nielson, C. M., Jacobs, J., Baker, E. S., Piehowski, P., Petyuk, V., Gao, Y., Shi, T., Smith, R. D., et al. (2020) · Aging Cell · doi:10.1111/acel.13253 · Cited by 23
“Decon2LS: An open-source software package for automated processing and visualization of high resolution mass spectrometry data.”
MethodSelf-citationTargeted analysis of glycomics liquid chromatography/mass spectrometry data
Dreyfuss, J. M., Jacobs, C. L., Gindin, Y., Benson, G., Staples, G. O., & Zaia, J. (2010) · Analytical and Bioanalytical Chemistry · doi:10.1007/s00216-010-4235-1 · Cited by 21
“This tool meets the need for rapid LC/ MS data analysis using an algorithm that is complementary to those of more resource-intensive programs [10–15].”
MethodKim, S. B., Zoepfl, M., Samanta, P., Zhang, F., Xia, K., Thara, R., Linhardt, R. J., Doerksen, R. J., McVoy, M. A., & Pomin, V. H. (2022) · Journal of Biological Chemistry · doi:10.1016/j.jbc.2022.101856 · Cited by 20
“Charge deconvolution was auto-processed by DeconTools software (75).”
Specific mutations in H5N1 mainly impact the magnitude and velocity of the host response in mice
Tchitchek, N., Eisfeld, A. J., Tisoncik-Go, J., Josset, L., Gralinski, L. E., Bécavin, C., Tilton, S. C., Webb‐Robertson, B., Ferris, M. T., Totura, A. L., et al. (2013) · BMC Systems Biology · doi:10.1186/1752-0509-7-69 · Cited by 21
“Decon2LS [60] and VIPER [61]; freely available at http://ncrr.”
Self-citationMisra, B. B. (2019) · Methods in molecular biology · doi:10.1007/978-1-4939-9831-9_15 · Cited by 21
Non-targeted N-glycome profiling reveals multiple layers of organ-specific diversity in mice
Helm, J., Mereiter, S., Oliveira, T., Gattinger, A., Markovitz, D. M., Penninger, J. M., Altmann, F., & Stadlmann, J. (2024) · Nature Communications · doi:10.1038/s41467-024-54134-z · Cited by 25
Basharat, A. R., Ning, X., & Liu, X. (2020) · Analytical Chemistry · doi:10.1021/acs.analchem.0c00903 · Cited by 20
Muscle Segment Homeobox Genes Direct Embryonic Diapause by Limiting Inflammation in the Uterus
Cha, J., Burnum-Johnson, K., Bartos, A., Li, Y., Baker, E. S., Tilton, S. C., Webb‐Robertson, B., Piehowski, P., Monroe, M. E., Jegga, A. G., et al. (2015) · Journal of Biological Chemistry · doi:10.1074/jbc.m115.655001 · Cited by 22
“Multiple bioinformatics tools developed in-house (19, 20) were used to process the IMS LC-MS data and correlate the resulting LC-MS features to our accurate mass and time tag database that contained IMS drift time, accurate mass, and LC separation elution time information for each peptide tag.”
MethodHigh and Low Doses of Ionizing Radiation Induce Different Secretome Profiles in a Human Skin Model
Zhang, Q., Matzke, M. M., Schepmoes, A., Moore, R., Webb‐Robertson, B., Hu, Z., Monroe, M. E., Qian, W., Smith, R. D., & Morgan, W. F. (2014) · PLoS ONE · doi:10.1371/journal.pone.0092332 · Cited by 18
“For the high resolution LC-MS datasets obtained from individual study samples, Decon2LS was used for peak finding and deisotoping at the individual MS spectrum level.[21] The output of Decon2LS that contains features of monoisotopic mass, intensity of most abundant isotope and elution time were further processed with…”
MethodSelf-citationBrown, J. N., Brewer, H. M., Nicora, C., Weitz, K., Morris, M. J., Skabelund, A. J., Adkins, J., Smith, R. D., Cho, J.-H., & Gelinas, R. E. (2014) · BMC Medical Genomics · doi:10.1186/1755-8794-7-58 · Cited by 18
“Accurate mass and time (AMT) tag [16-19] results were filtered for a mass error less than 3 ppm and by statistical tools for AMT tag confidence [20] for a uniqueness probability score greater than 0.”
MethodSelf-citationCao, L., Bryant, D. A., Schepmoes, A., Vogl, K., Smith, R. D., Lipton, M. S. W., & Callister, S. (2012) · Photosynthesis Research · doi:10.1007/s11120-011-9711-8 · Cited by 16
Self-citationPolacco, B. J., Purvine, S. O., Zink, E., LaVoie, S. P., Lipton, M. S. W., Summers, A. O., & Miller, S. M. (2011) · Molecular & Cellular Proteomics · doi:10.1074/mcp.m110.004853 · Cited by 21
“We use peak height, as used by Decon2LS (13) for example, instead of peak area, as used by MaxQuant (11) for example, as a measure of abundance to avoid the problem of determining peak boundaries.”
MethodResultInfluentialWang, X., Liu, X., Li, L., Zhang, F., Hu, M. Q., Ren, F., Chi, L., & Linhardt, R. J. (2016) · PLoS ONE · doi:10.1371/journal.pone.0167727 · Cited by 16
Deconvolution in mass spectrometry based proteomics
Guang, X., Stupak, J., Li, Y., Hu, L., Guo, B., & Li, J. (2018) · Rapid Communications in Mass Spectrometry · doi:10.1002/rcm.8103 · Cited by 22
Zhang, N., Li, G., Li, S., Cai, C., Zhang, F., Linhardt, R. J., & Yu, G. (2020) · Carbohydrate Polymers · doi:10.1016/j.carbpol.2020.115847 · Cited by 17
A new scoring function for top-down spectral deconvolution
Kou, Q., Wu, S., & Liu, X. (2014) · BMC Genomics · doi:10.1186/1471-2164-15-1140 · Cited by 18
“Combination of L-score and Decon2LS Decon2LS [11], a reimplementation of THRASH [7], reports a list of ranked envelopematches from a top-down mass spectrum.”
BackgroundMethodKirchner, M., Timm, W., Fong, P., Wangemann, P., & Steen, H. (2010) · Bioinformatics · doi:10.1093/bioinformatics/btq036 · Cited by 18
Non-Anticoagulant Low Molecular Weight Heparins for Pharmaceutical Applications
Ouyang, Y., Yu, Y., Zhang, F., Chen, J., Han, X., Xia, K., Yao, Y., Zhang, Z., & Linhardt, R. J. (2019) · Journal of Medicinal Chemistry · doi:10.1021/acs.jmedchem.8b01551 · Cited by 17
Existing bioinformatics tools for the quantitation of post-translational modifications
Allmer, J. (2010) · Amino Acids · doi:10.1007/s00726-010-0614-3 · Cited by 18
“Another more recent approach quantified the differential phosphorylation between two samples using a label-free strategy employing Decon2LS (Jaitly et al. 2009) and VIPER (Monroe et al. 2007) software packages (Yang et al. 2007).”
MethodAn efficient data format for mass spectrometry-based proteomics
Shah, A. R., Davidson, J., Monroe, M. E., Mayampurath, A. M., Danielson, W., Shi, Y. C., Robinson, A. C., Clowers, B. H., Belov, M. E., Anderson, G., et al. (2010) · Journal of the American Society for Mass Spectrometry · doi:10.1016/j.jasms.2010.06.014 · Cited by 17
“RAW files to this new file format, and extended the Decon2LS software [17] to read and process YAFMS files, allowing for visualization and deisotoping of rmats.”
MethodSelf-citationMcDermott, J., Jacobs, J., Merrill, N. J., Mitchell, H. D., Arshad, O. A., McClure, R., Teeguarden, J., Gajula, R. P., Porter, K. I., Satterfield, B. C., et al. (2024) · Journal of Proteome Research · doi:10.1021/acs.jproteome.3c00418 · Cited by 15
Improving N-Glycan Coverage using HPLC-MS with Electrospray Ionization at Subambient Pressure
Marginean, I., Kronewitter, S. R., Moore, R., Slysz, G., Monroe, M. E., Anderson, G., Tang, K., & Smith, R. D. (2012) · Analytical Chemistry · doi:10.1021/ac301961u · Cited by 15
Self-citationQuantitative Analysis of Protein Covalent Labeling Mass Spectrometry Data in the Mass Spec Studio
Ziemianowicz, D. S., Sarpe, V., & Schriemer, D. C. (2019) · Analytical Chemistry · doi:10.1021/acs.analchem.9b01625 · Cited by 16
Steinke, L., Slysz, G., Lipton, M. S. W., Klatt, C. G., Moran, J., Romine, M. F., Wood, J. M., Anderson, G., Bryant, D. A., & Ward, D. M. (2020) · Applied and Environmental Microbiology · doi:10.1128/aem.01829-19 · Cited by 19
“For each data set, LC-MS/MS mass and normalized elution time features were extracted using DeconTools (50, 51) and VIPER (52) and matched to peptides in the reference database.”
MethodSelf-citationMolecular investigation of the multi-phase photochemistry of Fe( iii )–citrate in aqueous solution
West, C. P., Morales, A. C., Ryan, J., Misovich, M. V., Hettiyadura, A. P. S., Rivera-Adorno, F. A., Tomlin, J. M., Darmody, A., Linn, B. N., Lin, P., et al. (2022) · Environmental Science Processes & Impacts · doi:10.1039/d1em00503k · Cited by 16
Kronewitter, S. R., Slysz, G., Marginean, I., Hagler, C. D., Lamarche, B. L., Zhao, R., Harris, M. Y., Monroe, M. E., Polyukh, C. A., Crowell, K. L., et al. (2014) · Analytical Chemistry · doi:10.1021/ac501492f · Cited by 13
Self-citationBPDA - A Bayesian peptide detection algorithm for mass spectrometry
Sun, Y., Zhang, J., Braga-Neto, U., & Dougherty, E. R. (2010) · BMC Bioinformatics · doi:10.1186/1471-2105-11-490 · Cited by 18
Bioinformatics Protocols in Glycomics and Glycoproteomics
Tang, H., Mayampurath, A. M., Yu, C., & Mechref, Y. S. (2014) · Current Protocols in Protein Science · doi:10.1002/0471140864.ps0215s76 · Cited by 15
“The software tool works on de-isotopic MS data; thus, Decon2LS tool (Jaitly et al., 2009) needs to be applied to the raw LC-MS data before the analysis.”
MethodSelf-citationOptimization-Based Peptide Mass Fingerprinting for Protein Mixture Identification
He, Z., Yang, C., Yang, C., Qi, R. Z., Tam, J. P.-M., & Yu, W. (2009) · Lecture notes in computer science · doi:10.1007/978-3-642-02008-7_2 · Cited by 12
Ma, J., Casey, C., Zheng, X., Ibrahim, Y., Wilkins, C. S., Renslow, R. S., Thomas, D., Payne, S., Monroe, M. E., Smith, R. D., et al. (2017) · Bioinformatics · doi:10.1093/bioinformatics/btx305 · Cited by 12
“The isotopic distribution score is calculated by quantifying the similarity between the theoretical (Jaitly et al. 2009) and observed isotopic distribution for each target molecule.”
MethodSelf-citationAnderson, L. N., Culley, D. E., Hofstad, B. A., Chauvignè-Hines, L. M., Zink, E., Purvine, S. O., Smith, R. D., Callister, S., Magnuson, J. K., & Wright, A. (2013) · Molecular BioSystems · doi:10.1039/c3mb70333a · Cited by 15
Self-citationdos Reis, J. B. A., Lorenzi, A. S., Pinho, D. B., Cardoso, P., & do Vale, H. M. M. (2024) · Archives of Microbiology · doi:10.1007/s00203-024-03911-x · Cited by 14
An Optimized Informatics Pipeline for Mass Spectrometry-Based Peptidomics
Wu, C., Monroe, M. E., Xu, Z., Slysz, G., Payne, S., Rodland, K., Liu, T., & Smith, R. D. (2015) · Journal of the American Society for Mass Spectrometry · doi:10.1007/s13361-015-1169-z · Cited by 11
“Least-squares fitting of the theoretical isotopic profile on the observed profile is then performed [28], providing a measure of how well the observed isotopic profile matches the theoretical isotopic profile.”
Self-citationNiu, M., Mao, X., Ying, W., Qin, W., Zhang, Y., & Qian, X. (2012) · Rapid Communications in Mass Spectrometry · doi:10.1002/rcm.6293 · Cited by 13
Features-Based Deisotoping Method for Tandem Mass Spectra
Yuan, Z., Shi, J., Lin, W., Chen, B., & Wu, F. (2011) · Advances in Bioinformatics · doi:10.1155/2011/210805 · Cited by 14
“THRASH [5], one of the most wellknown algorithms, is adapted by several algorithms, such as Decon2LS [8] and ICR2LS [10].”
MethodOptimization-Based Peptide Mass Fingerprinting for Protein Mixture IdentificationPreprint
He, Z., Yang, C., Yang, C., Qi, R. Z., Tam, J. P.-M., & Yu, W. (2008) · Nature Precedings · doi:10.1038/npre.2008.2268.1 · Cited by 12
Decoding cancer across scales with metabolomics
Rowles, J. L., & Patti, G. J. (2026) · Nature reviews. Cancer · doi:10.1038/s41568-026-00908-0 · Cited by 13
Wright, E. J., Beach, D. G., & McCarron, P. (2022) · Analytica Chimica Acta · doi:10.1016/j.aca.2022.339622 · Cited by 10
Automated And Unbiased Analysis of Lc–Ms Metabolomic Data
Hnatyshyn, S. Y., & Shipkova, P. A. (2012) · Bioanalysis · doi:10.4155/bio.12.9 · Cited by 10
Merkley, E. D., Anderson, B. J., Park, J., Belchik, S. M., Shi, L., Monroe, M. E., Smith, R. D., & Lipton, M. S. W. (2012) · Journal of Proteome Research · doi:10.1021/pr3007914 · Cited by 10
Self-citationState-of-the-art chromatographic and mass spectrometric techniques in heparin structural analysis
Ouyang, Y., Yang, S., Wang, W., Cui, J., & Zhang, Z. (2024) · Journal of Pharmaceutical and Biomedical Analysis · doi:10.1016/j.jpba.2024.116625 · Cited by 9
Waltman, P., Guo, J. P., Reistetter, E. N., Purvine, S. O., Ansong, C. K., van Baren, M. J., Wong, C., Wei, C., Smith, R. D., Callister, S., et al. (2016) · PLoS ONE · doi:10.1371/journal.pone.0155839 · Cited by 11
“High resolution MS scans from the same technical replicates were deisotoped using Decon2LS [29] to provide neutral mass and elution time values for all isotopic features in the technical replicates.”
MethodSelf-citationComparison of Different Labeling Techniques for the LC-MS Profiling of Human Milk Oligosaccharides
Lang, Y., Zhang, Y., Wang, C., Huang, L., Liu, X., Song, N., Li, G., & Yu, G. (2021) · Frontiers in Chemistry · doi:10.3389/fchem.2021.691299 · Cited by 10
Omics.pnl.gov: A Portal for the Distribution and Sharing of Multi-Disciplinary Pan-Omics Information
Auberry, K. J., Kiebel, G. R., Monroe, M. E., Adkins, J., Anderson, G., & Smith, R. D. (2010) · Journal of Proteomics & Bioinformatics · doi:10.4172/jpb.1000114 · Cited by 9
“Used to de-isotope MS spectra and to detect features from MS data using isotopic signatures of expected components (Jaitly et al., 2009).”
MethodSelf-citationSun, Y., Zhang, J., Braga-Neto, U., & Dougherty, E. R. (2011) · Bioinformatics · doi:10.1093/bioinformatics/btr675 · Cited by 9
Denoising Peptide Tandem Mass Spectra for Spectral Libraries: A Bayesian Approach
Shao, W., & Lam, H. (2013) · Journal of Proteome Research · doi:10.1021/pr400080b · Cited by 8
Proteoform characterization based on top-down mass spectrometry
Zhong, J., Sun, Y., Xie, M., Peng, W., Zhang, C., Wu, F., & Wang, J. (2020) · Briefings in Bioinformatics · doi:10.1093/bib/bbaa015 · Cited by 11
Varnum, S. M., Webb‐Robertson, B., Pounds, J. G., Moore, R., Smith, R. D., Frevert, C. W., Skerrett, S. J., & Wunschel, D. S. (2012) · Journal of Proteome Research · doi:10.1021/pr3001767 · Cited by 8
Self-citationŁącki, M. K., Lermyte, F., Miasojedow, B., Startek, M. P., Sobott, F., Valkenborg, D., & Gambin, A. (2019) · Analytical Chemistry · doi:10.1021/acs.analchem.8b01479 · Cited by 8
GPA: An algorithm for LC/MS based glycan profile annotation
Wang, M., Yu, G., Mechref, Y. S., & Ressom, H. W. (2013) · IEEE International Conference on Bioinformatics and Biomedicine (BIBM) · doi:10.1109/bibm.2013.6732616 · Cited by 8
“DeconTools assumes all the analytes are ionized through protons rather than other cations.”
MethodInfluentialParnell, J., Callister, S., Rompato, G., Nicora, C., Paša‐Tolić, L., Williamson, A., & Pfrender, M. E. (2011) · Scientific Reports · doi:10.1038/srep00025 · Cited by 7
“Orbitrap™ spectra were deisotoped using the software tool Decon2L”
MethodWang, H., Leeming, M. G., Ho, J., & Donald, W. A. (2018) · Chemistry - A European Journal · doi:10.1002/chem.201804668 · Cited by 7
LC–MS in Endogenous Metabolite Profiling and Small‐Molecule Biomarker Discovery
Reily, M. D., Shipkova, P. A., & Hnatyshyn, S. Y. (2011) · Wiley eBooks · doi:10.1002/9780470929278.ch21 · Cited by 7
Seasonal investigation of ultrafine-particle organic composition in an eastern Amazonian rainforest
Thomas, A. E., Glicker, H. S., Guenther, A., Seco, R., Bustillos, O. V., Tóta, J., de Souza, R. F., & SMITH, J. N. M. (2025) · Atmospheric chemistry and physics · doi:10.5194/acp-25-959-2025 · Cited by 8
Krishnan, S., Verheij, E. E. R., Bas, R. C., Hendriks, M. W. B., Hankemeier, T., Thissen, U., & Coulier, L. (2013) · Rapid Communications in Mass Spectrometry · doi:10.1002/rcm.6517 · Cited by 6
“In contrast to the abovemethods, some others use known chemical knowledge such as peak isotopic distribution to eliminate redundant information (m/z channels), that otherwise would interfere with the peak picking or contaminate the peak resolving methods.([13,14]) This process of clustering isotopic peaks of amolecule…”
ResultMazur, M. T., & Fyhr, R. (2011) · Rapid Communications in Mass Spectrometry · doi:10.1002/rcm.5257 · Cited by 6
Hu, A. K., Lu, Y. Y., Bilmes, J., & Noble, W. S. (2018) · Journal of Proteome Research · doi:10.1021/acs.jproteome.8b00365 · Cited by 7
Improving peptide identification with single-stage mass spectrum peaks
He, Z., & Yu, W. (2009) · Bioinformatics · doi:10.1093/bioinformatics/btp501 · Cited by 6
Kim, J., Lee, S., Park, K., Na, S., Paek, E., Park, H. S., Park, H., Lee, K., Jeong, J., & Kim, H. (2012) · Journal of Proteome Research · doi:10.1021/pr300232y · Cited by 6
Characterization of the Ovarian Tumor Peptidome
Liu, T., Rodland, K., & Smith, R. D. (2018) · Vitamins and hormones · doi:10.1016/bs.vh.2018.01.020 · Cited by 5
“Least-squares fitting of the theoretical isotopic profile on the observed profile is then performed (Jaitly et al., 2009).”
BackgroundSelf-citationAutomatic annotation and visualization tool for mass spectrometry based glycomics
Guang, X., Liu, X., Liu, Q. Y., Li, J., & Zhou, Y. (2016) · Rapid Communications in Mass Spectrometry · doi:10.1002/rcm.7735 · Cited by 5
Zhong, J., Song, X., & Wang, S. (2024) · Analytical Chemistry · doi:10.1021/acs.analchem.4c00152 · Cited by 4
Xie, S., Bu, C., LaCava, J., & Chi, L. (2023) · Journal of Chromatography A · doi:10.1016/j.chroma.2023.464179 · Cited by 4
Tay, A. P., Liang, A., Hamey, J. J., Hart‐Smith, G., & Wilkins, M. R. (2019) · PROTEOMICS · doi:10.1002/pmic.201800444 · Cited by 7
Bioinformatics and Biostatistics in Precision Medicine
Cephe, A., Koçhan, N., Aksel, E. G., İpekten, F., Yerlitaş, S. İ., Zararsız, G. E., & Zararsız, G. (2023) · Springer eBooks · doi:10.1007/978-981-99-1529-3_8 · Cited by 6
Halpern, E. R., Dotson, D., Xie, Q., Christ, P. E., MacFeely, K. T., Heirty, L., Nizkorodov, S. A., & Laskin, A. (2026) · Aerosol Science and Technology · doi:10.1080/02786826.2025.2609955 · Cited by 3
“Individual HRMS peaks were extracted using DeconTools Autoprocessor ( http://omics.pnl.gov/software/) ( Jaitly et al. 2009).”
Quantitative Mapping of NHS Ester–Protein Reactivity Using Native Top-Down Mass Spectrometry
Bennett, J. L., Ramsay, O. B., Lutomski, C. A., Kirschbaum, C., & Robinson, C. V. (2026) · Journal of the American Society for Mass Spectrometry · doi:10.1021/jasms.5c00395 · Cited by 3
A Comparative View Of Applying Linear And Non-Linear Visualisation Approaches To Protein Dataset
Manzoor, S., Jaskani, F. H., & Riaz, O. (2019) · EAI Endorsed Transactions on Creative Technologies · doi:10.4108/eai.13-7-2018.161109 · Cited by 3
“X-pillar Crystallography [20], Nuclear Magnetic Resonance Spectroscopy [21] and Electron Microscopy [21] are the standard strategies for choosing three-dimensional protein structures.”
BackgroundMethodPhosphoproteomic response of cardiac endothelial cells to ischemia and ultrasound
Emechebe, U., Giraud, D., Ammi, A. Y., Scott, K. L., Jacobs, J., McDermott, J., Dykan, I. V., Alkayed, N. J., Barnes, A. P., Kaul, S., et al. (2021) · Biochimica et Biophysica Acta (BBA) - Proteins and Proteomics · doi:10.1016/j.bbapap.2021.140683 · Cited by 3
Ruse, C. I., Peacock, S., Ghiban, C., Rivera, K. D., Pappin, D., & Leopold, P. (2013) · PROTEOMICS · doi:10.1002/pmic.201300022 · Cited by 3
“One can envision coupling our approach with further modeling of high mass accuracy MS data [47].”
MethodIncreasing the Efficiency of Data Storage and Analysis Using Indexed Compression
Beagley, N., Scherrer, C., Shi, Y., Clowers, B. H., Danielson, W., & Shah, A. R. (2009) · IEEE International Conference on eScience · doi:10.1109/e-science.2009.18 · Cited by 3
“Bioinformatics methods are then used to identify and quantify the potentially thousands of proteins present in the sample [4-6].”
MethodTopic model-based mass spectrometric data analysis in cancer biomarker discovery studies
Wang, M., Tsai, T., Poto, C. D., Ferrarini, A., Yu, G., & Ressom, H. W. (2016) · BMC Genomics · doi:10.1186/s12864-016-2796-x · Cited by 3
The Software-Landscape in (Prote)Omic Research
Krappmann, M. (2015) · Journal of Proteomics & Bioinformatics · doi:10.4172/jpb.1000365 · Cited by 3
“DeconLS [37] Pacific Northwest National Laboratory 2009 Detection of molecule properties with MS-data and isotopes signatures, Deconvolution C++, C#, Microsoft NET Framework a.”
MethodQuantitative Glycomics by Mass Spectrometry and Liquid Chromatography‐Mass Spectrometry
Mechref, Y. S., Zhou, S., Hu, Y., Hussein, A., & Tang, H. (2014) · Wiley eBooks · doi:10.1002/9780470027318.a9400 · Cited by 3
In – Silico Biological Evaluation of Anticancer Drugs - SWISS ADME
Nizamuddin, N. D., Roopa, D., Alla, P., Shaik, A. S., Vamshi Kumar Achari, P., & Kapu, S. R. (2024) · Future Journal of Pharmaceuticals and Health Sciences · doi:10.26452/fjphs.v4i2.604 · Cited by 3
SyncPro : A synchronized visualization tool for differential analysis of proteomics data sets
Yung, L. S., Yang, C., Dakna, M., Mischak, H., & Yu, W. (2010) · IEEE International Conference on Bioinformatics and Biomedicine Workshops (BIBMW) · doi:10.1109/bibmw.2010.5703780 · Cited by 2
“VIPER [1], MASIC [2] and Decon2LS [3] provide different views of MS data sets with each view focusing on a specific attribute of MS data set.”
BackgroundPepPre: Promote Peptide Identification Using Accurate and Comprehensive Precursors
Tarn, C., Wu, Y., & Wang, K. (2023) · Journal of Proteome Research · doi:10.1021/acs.jproteome.3c00293 · Cited by 2
Achroma: a software strategy for analysing (a-)typical mass-spectrometric data
Krappmann, M., & Letzel, T. (2012) · Analytical Methods · doi:10.1039/c2ay05622d · Cited by 2
iTop-Q: an Intelligent Tool for Top-down Proteomics Quantitation Using DYAMOND Algorithm
Chang, H.-Y., Chen, C.-T., Ko, C.-L., Chen, Y., Chen, Y., Hsu, W., Juo, C., & Sung, T. (2017) · Analytical Chemistry · doi:10.1021/acs.analchem.7b02343 · Cited by 2
Chemical characterization of biomass pyrolysis oil facilitated by aerosolization and size separation
Halpern, E. R., West, C. P., Hettiyadura, A. P. S., Darmody, A., Johnson, J. K., Qian, K., & Laskin, A. (2023) · Aerosol Science and Technology · doi:10.1080/02786826.2023.2254355 · Cited by 2
“The HRMS data was acquired using Thermo Scientific Xcalibur software and the list of the experimental HRMS features was extracted using DeconTools Autoprocessor (http://omics.pnl.gov/software/), an automated, batch, MS feature-finding tool (Jaitly et al. 2009).”
MethodProtocol for analysis of glycoproteomics LC-MS data using GlycReSoftPreprint
Klein, J., & Zaia, J. (2020) · bioRxiv (Cold Spring Harbor Laboratory) · doi:10.1101/2020.05.22.108928 · Cited by 2
Shah, A. R., Jaitly, N., Zuljevic, N., Monroe, M. E., Liyu, A. V., Polpitiya, A. D., Adkins, J., Belov, M. E., Anderson, G., Smith, R. D., et al. (2009) · IEEE International Conference on eScience · doi:10.1109/e-science.2009.21 · Cited by 1
“We use algorithms from the Decon2LS [23] open source software package for the deconvolution of the spectra in real time.”
MethodSelf-citationLane, N. M., Gregorich, Z. R., & Ge, Y. (2016) · Springer eBooks · doi:10.1007/978-3-319-31828-8_8 · Cited by 1
NBPMF: Novel network-based inference methods for peptide mass fingerprinting
Liang, Z., Lajoie, G., & Zhang, K. (2017) · IEEE International Conference on Cognitive Informatics & Cognitive Computing (ICCI*CC) · doi:10.1109/icci-cc.2017.8109752 · Cited by 1
“We first employ Decon2LS [5] to find peaks in individual mass spectra from raw LC-MS data.”
MethodNBPMF: Novel Peptide Mass Fingerprinting Based on Network Inference
Liang, Z., Lajoie, G., & Zhang, K. (2017) · International Journal of Cognitive Informatics and Natural Intelligence · doi:10.4018/ijcini.2017100103 · Cited by 2
Ortega, C. (2014) · ResearchWorks at the University of Washington (University of Washington) · Cited by 1
Belov (2017) · Digital Repository Service (Northeastern University) · doi:10.17760/d20259955 · Cited by 1
Meta-analysis of LC-MS based metabolomic experiments
Varghese, R. S., Zhou, B., & Ressom, H. W. (2011) · IEEE International Conference on Bioinformatics and Biomedicine Workshops (BIBMW) · doi:10.1109/bibmw.2011.6112369 · Cited by 1
“Decon2LS [12] works on the raw data instead of the peak list.”
BackgroundPark, J.-M., Han, N., Kim, H., Hwang, I., Kim, J. B., Hahm, K. B., Lee, S., & Lee, H. (2014) · Mass spectrometry letters · doi:10.5478/msl.2014.5.1.16
Metadata
- Authors
- Jaitly, N., Mayampurath, A., Littlefield, K., Adkins, J. N., Anderson, G. A., & Smith, R. D.
- Affiliations
- Pacific Northwest National Laboratory (US)
- Corresponding author
- Smith, Richard D
- Venue
- BMC Bioinformatics
- Published
- 2009-03-17
- Volume
- 10
- Issue
- 1
- Pages
- 87-87
- ISSN
- 1471-2105 (ISSN-L)
- PMC
- PMC2666663
- OpenAlex
- W2014186056
- Cited by
- 217
- References
- 26
- Citations by year
- 2026: 7 · 2025: 4 · 2024: 6 · 2023: 5 · 2022: 4 · 2021: 3 · 2020: 11 · 2019: 9 · 2018: 12 · 2017: 12 · 2016: 18 · 2015: 15 · 2014: 23 · 2013: 23 · 2012: 19
- FWCI
- 8.73
- Type
- journal article
- Language
- en
- Open access
- gold
- doi.org
- Licence
- cc-by
- Locations
- BMC Bioinformatics (publishedVersion, cc-by)
- PubMed Central (publishedVersion, cc-by)
- PubMed (publishedVersion)
- TSpace (University of Toronto) (submittedVersion)
- DOAJ (DOAJ: Directory of Open Access Journals) (submittedVersion)
- Funders
- U.S. Department of Energy (RR018522, DE-AC05?, 76RLO 1830, DE‐AC05‐76RLO1830)
- Battelle (DE-AC05, DE‐AC05‐76RLO 1830)
- National Institutes of Health
- National Center for Research Resources (P41RR018522, RR-018522)
- Biological and Environmental Research (DE-AC05-76RLO-1830, RR018522)
- Pacific Northwest National Laboratory (DE-AC05-76RLO 1830)
- Topics
- Life Sciences › Biochemistry, Genetics and Molecular Biology › Molecular Biology › Metabolomics and Mass Spectrometry Studies
- Physical Sciences › Chemistry › Spectroscopy › Advanced Proteomics Techniques and Applications
- Physical Sciences › Chemistry › Spectroscopy › Mass Spectrometry Techniques and Applications
- Keywords
- high-resolution mass spectrometry, LC-MS data processing, peak detection, proteomics, peptide identification, open source software
- MeSH terms
- Algorithms, Chromatography, Liquid, Software, Mass Spectrometry, Proteomics
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.