Decon2LS: An open-source software package for automated processing and visualization of high resolution mass spectrometry data
Open accessThe DOI matches its Crossref record; 28 of the 28 references it cites were found in a registry or an index.
Abstract
Background: Data generated from liquid chromatography coupled to high-resolution mass spectrometry (LC-MS)-based studies of a biological sample can contain large amounts of biologically significant information in the form of proteins, peptides, and metabolites. Interpreting this data involves inferring the masses and abundances of biomolecules injected into the instrument. Because of the inherent complexity of mass spectral patterns produced by these biomolecules, the analysis is significantly enhanced by using visualization capabilities to inspect and confirm results. In this paper we describe Decon2LS, an open-source software package for automated processing and visualization of high-resolution MS data. Drawing extensively on algorithms developed over the last ten years for ICR2LS, Decon2LS packages the algorithms as a rich set of modular, reusable processing classes for performing diverse functions such as reading raw data, routine peak finding, theoretical isotope distribution modelling, and deisotoping. Because the source code is openly available, these functionalities can now be used to build derivative applications in relatively fast manner. In addition, Decon2LS provides an extensive set of visualization tools, such as high performance chart controls. Results: With a variety of options that include peak processing, deisotoping, isotope composition, etc, Decon2LS supports processing of multiple raw data formats. Deisotoping can be performed on an individual scan, an individual dataset, or on multiple datasets using batch processing. Other processing options include creating a two dimensional view of mass and liquid chromatography (LC) elution time features, generating spectrum files for tandem MS data, creating total intensity chromatograms, and visualizing theoretical peptide profiles. Application of Decon2LS to deisotope different datasets obtained across different instruments yielded a high number of features that can be used to identify and quantify peptides in the biological sample. Conclusion: Decon2LS is an efficient software package for discovering and visualizing features in proteomics studies that require automated interpretation of mass spectra. Besides being easy to use, fast, and reliable, Decon2LS is also open-source, which allows developers in the proteomics and bioinformatics communities to reuse and refine the algorithms to meet individual needs. Decon2LS source code, installer, and tutorials may be downloaded free of charge at http://http:/ncrr.pnl.gov/software/.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Figures







Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
The cited source says what the claim attributes to it.
In the citing paper
“Importing data obtained from different MS instruments is supported using ProteoWizard,12 DeconEngine,13 and vendor provided libraries.”
From MASH Explorer: A Universal Software Environment for Top-Down Proteomics (2020) · cites this paper as [13]
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Eng, J. K., McCormack, A. L., & Yates, J. R. (1994) · Journal of the American Society for Mass Spectrometry · doi:10.1016/1044-0305(94)80016-2 · Cited by 6,484 · cited 1×
“These files can be processed using search-engines such as SEQUEST[22] to identify peptides.”
MethodSmith, C. A., Want, E. J., O'Maille, G., Abagyan, R., & Siuzdak, G. (2006) · Analytical Chemistry · doi:10.1021/ac051437y · Cited by 5,262 · cited 1×
“While XCMS [13] is useful for data pre-processing, peak-detection, retention-time alignment and peak matching across samples, this algorithm also does not perform deisotoping. msInspect [14] is an analysis package for deisotoping high-resolution LC-MS data in mzXML format in sequential steps.”
MethodOpenMS – An open-source software framework for mass spectrometry
Sturm, M., Bertsch, A., Gröpl, C., Hildebrandt, A., Hussong, R., Lange, E., Pfeifer, N., Schulz-Trieglaff, O., Zerck, A., Reinert, K., et al. (2008) · BMC Bioinformatics · doi:10.1186/1471-2105-9-163 · Cited by 644
Interpreting mass spectra of multiply charged ions
Mann, M., Meng, C. K., & Fenn, J. B. (1989) · Analytical Chemistry · doi:10.1021/ac00190a023 · Cited by 588 · cited 1×
“Several deisotoping and visualization algorithms have been described in the literature [3-9] and are available as part of commercial vendor packages such as XCalibur (Thermo Fisher), MassHunter (Agilent) and Elucidator System (Rosetta Biosoftware).”
MethodZhang, Z., & Marshall, A. G. (1998) · Journal of the American Society for Mass Spectrometry · doi:10.1016/s1044-0305(97)00284-5 · Cited by 509 · cited 1×
“Several deisotoping and visualization algorithms have been described in the literature [3-9] and are available as part of commercial vendor packages such as XCalibur (Thermo Fisher), MassHunter (Agilent) and Elucidator System (Rosetta Biosoftware).”
MethodAutomated reduction and interpretation of
Horn, D. M., Zubarev, R. A., & McLafferty, F. W. (2000) · Journal of the American Society for Mass Spectrometry · doi:10.1016/s1044-0305(99)00157-9 · Cited by 507
Senko, M. W., Beu, S. C., & McLaffertycor, F. W. (1995) · Journal of the American Society for Mass Spectrometry · doi:10.1016/1044-0305(95)00017-8 · Cited by 451 · cited 2×
“The most likely empirical composition is determined using the average mass determined in step 2 and the Averagine algorithm [17], which assumes an empirical composition that is equal to the average composition of all the peptides in a protein FASTA file.”
MethodAn accurate mass tag strategy for quantitative and high-throughput proteome measurements
Smith, R. D., Anderson, G. A., Lipton, M. S., Pasa-Tolic, L., Shen, Y., Conrads, T. P., Veenstra, T. D., & Udseth, H. R. (2002) · PROTEOMICS · doi:10.1002/1615-9861(200205)2:5<513::aid-prot513>3.0.co;2-w · Cited by 432 · cited 2×
“tides in a database constructed from previous LC-MS/MS analyses [20].”
MethodSelf-citationBellew, M., Coram, M., Fitzgibbon, M., Igra, M., Randolph, T., Wang, P., May, D., Eng, J., Fang, R., Lin, C., et al. (2006) · Bioinformatics · doi:10.1093/bioinformatics/btl276 · Cited by 265 · cited 1×
“msInspect [14] is an analysis package for deisotoping high-resolution LC-MS data in mzXML format in sequential steps.”
MethodSenko, M. W., Canterbury, J. D., Guan, S., & Marshall, A. G. (1996) · Rapid Communications in Mass Spectrometry · doi:10.1002/(sici)1097-0231(199611)10:14<1839::aid-rcm718>3.0.co;2-v · Cited by 259 · cited 1×
“While a functional application of THRASH was not provided by its developers, the algorithm was reportedly incorporated into the MIDAS [18] data system.”
Method
Cited by
Advances in structure elucidation of small molecules using mass spectrometry
Kind, T., & Fiehn, O. (2010) · Bioanalytical Reviews · doi:10.1007/s12566-010-0015-9 · Cited by 480
“Open-source software tools, such as Decon2LS [136], exist (see Fig.”
MethodDiamond, D. L., Syder, A. J., Jacobs, J. M., Sorensen, C. M., Walters, K.-A., Proll, S. C., McDermott, J. E., Gritsenko, M. A., Zhang, Q., Zhao, R., et al. (2010) · PLoS Pathogens · doi:10.1371/journal.ppat.1000719 · Cited by 412
“Decon2LS [26], VIPER [27]; freely available at http://ncrr.”
BackgroundSelf-citationLin, P., Liu, J., Shilling, J. E., Kathmann, S. M., Laskin, J., & Laskin, A. (2015) · Physical Chemistry Chemical Physics · doi:10.1039/c5cp02563j · Cited by 306
Yu, L., Smith, J., Laskin, A., Anastasio, C., Laskin, J., & Zhang, Q. (2014) · Atmospheric Chemistry and Physics · doi:10.5194/acp-14-13801-2014 · Cited by 272
“Peaks with a S / N (signal-to-noise ratio) > 10 were selected using the Decon2LS software developed at the Pacific Northwest National Laboratory (PNNL) (Jaitly et al., 2009).”
MethodRevealing Brown Carbon Chromophores Produced in Reactions of Methylglyoxal with Ammonium Sulfate
Lin, P., Laskin, J., Nizkorodov, S. A., & Laskin, A. (2015) · Environmental Science & Technology · doi:10.1021/acs.est.5b03608 · Cited by 231
Piehowski, P. D., Petyuk, V. A., Orton, D. J., Xie, F., Moore, R. J., Ramirez-Restrepo, M., Engel, A., Lieberman, A. P., Albin, R. L., Camp, D. G., et al. (2013) · Journal of Proteome Research · doi:10.1021/pr301146m · Cited by 228
Self-citationLiquid chromatography mass spectrometry-based proteomics: Biological and technological aspects
Karpievitch, Y. V., Polpitiya, A. D., Anderson, G. A., Smith, R. D., & Dabney, A. R. (2010) · The Annals of Applied Statistics · doi:10.1214/10-aoas341 · Cited by 222
Self-citationTop‐down proteomics in health and disease: Challenges and opportunities
Gregorich, Z. R., & Ge, Y. (2014) · PROTEOMICS · doi:10.1002/pmic.201300432 · Cited by 217
“Decon2LS, which is a software package for the automated processing and visualization of high-resolution MS spectra, uses a variation of the THRASH algorithm for deconvolution [128].”
BackgroundMethodInfluentialTop-Down Proteomics: Ready for Prime Time?
Chen, B., Brown, K. A., Lin, Z., & Ge, Y. (2018) · Analytical Chemistry · doi:10.1021/acs.analchem.7b04747 · Cited by 210
Laskin, J., Laskin, A., Roach, P. J., Slysz, G. W., Anderson, G. A., Nizkorodov, S. A., Bones, D. L., & Nguyen, L. Q. (2010) · Analytical Chemistry · doi:10.1021/ac902801f · Cited by 194
Self-citationAlgorithms and tools for the preprocessing of LC–MS metabolomics data
Castillo, S., Gopalacharyulu, P., Yetukuri, L., & Orešič, M. (2011) · Chemometrics and Intelligent Laboratory Systems · doi:10.1016/j.chemolab.2011.03.010 · Cited by 175
GlycReSoft: A Software Package for Automated Recognition of Glycans from LC/MS Data
Maxwell, E., Tan, Y., Tan, Y., Hu, H., Benson, G., Aizikov, K., Conley, S., Staples, G. O., Slysz, G. W., Smith, R. D., et al. (2012) · PLoS ONE · doi:10.1371/journal.pone.0045474 · Cited by 168
“Decon2LS is an open-source software package designed for automated processing of high resolution mass spectral data [4].”
MethodSelf-citationSims, A. C., Tilton, S. C., Menachery, V. D., Gralinski, L. E., Schäfer, A., Matzke, M. M., Webb-Robertson, B.-J. M., Chang, J., Luna, M. L., Long, C. E., et al. (2013) · Journal of Virology · doi:10.1128/jvi.02520-12 · Cited by 158
“Quantitative LC-MS data sets were processed using the PRISM data analysis system (48), which is a series of software tools developed in-house (e.g., Decon2LS [49] and VIPER [50], which is freely available at http://ncrr.pnl.gov/software/).”
MethodSelf-citationZhang, H., Burnum, K. E., Luna, M. L., Petritis, B. O., Kim, J., Qian, W., Moore, R. J., Heredia‐Langner, A., Webb‐Robertson, B. M., Thrall, B. D., et al. (2011) · PROTEOMICS · doi:10.1002/pmic.201100037 · Cited by 145
“[24] Jaitly, N., Mayampurath, A., Littlefield, K., Adkins, J. N. et al., Decon2LS: An open-source software package for automated processing and visualization of high resolution mass spectrometry data.”
MethodSelf-citationLabel-Free Quantitative LC–MS Proteomics of Alzheimer’s Disease and Normally Aged Human Brains
Andreev, V. P., Petyuk, V. A., Brewer, H. M., Karpievitch, Y. V., Xie, F., Clarke, J., Camp, D., Smith, R. D., Lieberman, A. P., Albin, R. L., et al. (2012) · Journal of Proteome Research · doi:10.1021/pr3001546 · Cited by 142
Self-citationMASH Suite Pro: A Comprehensive Software Tool for Top-Down Proteomics
Cai, W., Guner, H., Gregorich, Z. R., Chen, A. J., Ayaz-Guner, S., Peng, Y., Valeja, S. G., Liu, X., & Ge, Y. (2016) · Molecular & Cellular Proteomics · doi:10.1074/mcp.o115.054387 · Cited by 132
“The default algorithm for spectral deconvolution in MASH Suite Pro is a modified version of THRASH (25) that we developed in-house based on the Decon2LS open source code (38).”
MethodSidoli, S., Cheng, L., & Jensen, O. N. (2012) · Journal of Proteomics · doi:10.1016/j.jprot.2011.12.029 · Cited by 146
Roach, P. J., Laskin, J., & Laskin, A. (2010) · Analytical Chemistry · doi:10.1021/ac101449p · Cited by 130
Development of a new ion mobility time-of-flight mass spectrometer
Ibrahim, Y., Baker, E. S., Danielson, W., Norheim, R. V., Prior, D. C., Anderson, G., Belov, M. E., & Smith, R. D. (2014) · International Journal of Mass Spectrometry · doi:10.1016/j.ijms.2014.07.034 · Cited by 122
Self-citationMitchell, H. D., Eisfeld, A. J., Sims, A. M., McDermott, J., Matzke, M. M., Webb‐Robertson, B., Tilton, S. C., Tchitchek, N., Josset, L., Li, C., et al. (2013) · PLoS ONE · doi:10.1371/journal.pone.0069374 · Cited by 122
“Decon2LS [56] and VIPER [57] freely available at http://ncrr.”
BackgroundSelf-citationTeeguarden, J., Webb‐Robertson, B., Waters, K. M., Murray, A. R., Kisin, E. R., Varnum, S. M., Jacobs, J., Pounds, J. G., Zanger, R. C., & Shvedova, A. A. (2010) · Toxicological Sciences · doi:10.1093/toxsci/kfq363 · Cited by 121
“The mass deisotoping and alignment process were performed using Decon2LS (Jaitly et al., 2009), and the matching process was performed using VIPER (Monroe et al., 2007) (http://ncrr.pnl.gov/software).”
MethodProfiling and quantifying endogenous molecules in single cells using nano-DESI MS
Bergman, H.-M., & Lanekoff, I. (2017) · The Analyst · doi:10.1039/c7an00885f · Cited by 109
Improved quality control processing of peptide-centric LC-MS proteomics data
Matzke, M. M., Waters, K. M., Metz, T. O., Jacobs, J. M., Sims, A. C., Baric, R. S., Pounds, J. G., & Webb-Robertson, B.-J. M. (2011) · Bioinformatics · doi:10.1093/bioinformatics/btr479 · Cited by 107
“The mass de-isotoping process was performed using Decon2LS (Jaitly et al., 2009) , and the matching process was performed using VIPER (Monroe et al., 2007) .”
MethodLanekoff, I., Thomas, M., & Laskin, J. (2014) · Analytical Chemistry · doi:10.1021/ac403931r · Cited by 110
Bergman, H., Lundin, E., Andersson, M., & Lanekoff, I. (2016) · The Analyst · doi:10.1039/c5an02620b · Cited by 116
Webb-Robertson, B.-J. M., McCue, L. A., Waters, K. M., Matzke, M. M., Jacobs, J. M., Metz, T. O., Varnum, S. M., & Pounds, J. G. (2010) · Journal of Proteome Research · doi:10.1021/pr1005247 · Cited by 102
Quantitative Glycomics Strategies
Mechref, Y., Hu, Y., Desantos-Garcia, J. L., Hussein, A., & Tang, H. (2013) · Molecular & Cellular Proteomics · doi:10.1074/mcp.r112.026310 · Cited by 103
“GlycReSoft (95) is a software tool that takes as input the de-isotoped LC/MS data output from the Decon2LS tool (96), annotates de-isotoped peaks using a default or user-defined glycan library, and reports the intensity of the peaks annotated as glycans.”
MethodTop-down Proteomics: Technology Advancements and Applications to Heart Diseases
Cai, W., Tucholski, T. M., Gregorich, Z. R., & Ge, Y. (2016) · Expert Review of Proteomics · doi:10.1080/14789450.2016.1209414 · Cited by 99
“Decon2LS uses a variation of THRASH for high-resolution spectral analysis and visualization [86].”
MethodPeptide and protein quantification: A map of the minefield
Vaudel, M., Sickmann, A., & Martens, L. (2010) · PROTEOMICS · doi:10.1002/pmic.200900481 · Cited by 118
“php?title 5 Software:Libra [48] ProQuant raw data No https://products.”
BackgroundGao, X., Zhang, Q., Meng, D., Isaac, G., Zhao, R., Fillmore, T., Chu, R., Zhou, J., Tang, K., Hu, Z., et al. (2012) · Analytical and Bioanalytical Chemistry · doi:10.1007/s00216-012-5773-5 · Cited by 105
“The first step involved deisotoping of the raw MS data to give the monoisotopic mass, charge state, and intensity of the major peaks in each mass spectrum using Decon2LS [38].”
MethodSelf-citationWinkler, R. (2010) · Rapid Communications in Mass Spectrometry · doi:10.1002/rcm.4384 · Cited by 104
Khatri, K., Klein, J., White, M. R., Grant, O. C., Leymarie, N., Woods, R. J., Hartshorn, K. L., & Zaia, J. (2016) · Molecular & Cellular Proteomics · doi:10.1074/mcp.m116.058016 · Cited by 96
“1) Glycomics— Negative mode HILIC-MS data were deconvoluted and deisotoped using the THRASH algorithm in DeconTools/ Decon2LS (version 1.0.5501) (38, 39).”
MethodInfluentialDepuydt, G., Xie, F., Petyuk, V. A., Shanmugam, N., Smolders, A., Dhondt, I., Brewer, H. M., Camp, D. G., Smith, R. D., & Braeckman, B. P. (2013) · Molecular & Cellular Proteomics · doi:10.1074/mcp.m113.027383 · Cited by 93
“3 and SignalToNoiseThreshold 2) (67) followed by grouping of monoisotopic peaks constituting the LC profile and assignment of LC-MS features to peptides using VIPER (version 3.”
BackgroundSelf-citationAlgorithms and design strategies towards automated glycoproteomics analysis
Hu, H., Khatri, K., & Zaia, J. (2016) · Mass Spectrometry Reviews · doi:10.1002/mas.21487 · Cited by 91
“The output files from Decon2LS have been used by a few glycomics tools such as GlyReSoft (Maxwell et al., 2012) and MultiGlycan (Yu et al., 2013).”
A Multi-Omic View of Host-Pathogen-Commensal Interplay in Salmonella-Mediated Intestinal Infection
Kaiser, B. L. D., Li, J., Sanford, J. A., Kim, Y., Kronewitter, S. R., Jones, M. B., Peterson, C. T., Peterson, S. N., Frank, B. C., Purvine, S. O., et al. (2013) · PLoS ONE · doi:10.1371/journal.pone.0067155 · Cited by 87
“Preprocessing involved peak picking, noise thresholding, and monoisotopic identification using THRASH [31], and is based off of the former Decon2LS engine [32].”
MethodSelf-citationArtificial intelligence in microbial natural product drug discovery: current and emerging role
Sahayasheela, V. J., Lankadasari, M. B., Dan, V. M., Dastager, S. G., Pandian, G. N., & Sugiyama, H. (2022) · Natural Product Reports · doi:10.1039/d2np00035k · Cited by 91
Cubison, M. J., Sueper, D., & Jimenez, J. L. (2015) · Atmospheric measurement techniques · doi:10.5194/amt-8-2333-2015 · Cited by 98
“…problem have been extensively reported in the literature, in both mass spectroscopy fields such as liquidchromatography MS (LC-MS; see e.g. Jaitly et al., 2009; Yu and Peng, 2010), matrix-assisted laser desorption/ionisation MS (MALDI-MS; see e.g. Sun et al., 2010; House et al., 2011),…”
BackgroundA review of methods for interpretation of glycopeptide tandem mass spectral data
Hu, H., Khatri, K., Klein, J., Leymarie, N., & Zaia, J. (2015) · Glycoconjugate Journal · doi:10.1007/s10719-015-9633-3 · Cited by 82
“For this purpose, the DeconTools program is publically available [50, 51].”
MethodMolecular insights into the composition, sources, and aging of atmospheric brown carbon
Laskin, A., West, C. P., & Hettiyadura, A. P. S. (2025) · Chemical Society Reviews · doi:10.1039/d3cs00609c · Cited by 87
MASH Explorer: A Universal Software Environment for Top-Down Proteomics
Wu, Z., Roberts, D. S., Melby, J. A., Wenger, K., Wetzel, M., Gu, Y., Ramanathan, S. G., Bayne, E. F., Liu, X., Sun, R., et al. (2020) · Journal of Proteome Research · doi:10.1021/acs.jproteome.0c00469 · Cited by 76
Aevermann, B. D., Pickett, B. E., Kumar, S., Klem, E. B., Agnihothram, S., Askovich, P. S., Bankhead, A., Bolles, M., Carter, V., Chang, J., et al. (2014) · Scientific Data · doi:10.1038/sdata.2014.33 · Cited by 74
“Quantitative LC-MS datasets were processed using the PRISM Data Analysis system 37 , which is a series of software tools developed in-house (e.g. Decon2LS 38 and VIPER 39 ; freely available at http://ncrr.pnl.gov/ software/).”
MethodSelf-citationGuner, H., Close, P. L., Cai, W., Zhang, H., Peng, Y., Gregorich, Z. R., & Ge, Y. (2014) · Journal of the American Society for Mass Spectrometry · doi:10.1007/s13361-013-0789-4 · Cited by 73
“The algorithm used in MASH Suite is based on THRASH [5] and Decon2LS open source code [6].”
Quantitative shotgun proteome analysis by direct infusion
Meyer, J. G., Niemi, N. M., Pagliarini, D. J., & Coon, J. J. (2020) · Nature Methods · doi:10.1038/s41592-020-00999-z · Cited by 80
Ge, X., Shaw, S. L., & Zhang, Q. (2014) · Environmental Science & Technology · doi:10.1021/es4056966 · Cited by 76
pTop 1.0: A High-Accuracy and High-Efficiency Search Engine for Intact Protein Identification
Sun, R.-X., Luo, L., Wu, L., Wang, R.-M., Zeng, W.-F., Chi, H., Liu, C., & He, S.-M. (2016) · Analytical Chemistry · doi:10.1021/acs.analchem.5b03963 · Cited by 71
pParse: A method for accurate determination of monoisotopic peaks in high‐resolution mass spectra
Yuan, Z. E., Liu, C., Wang, H., Sun, R., Fu, Y., Zhang, J., Wang, L., Chi, H., Li, Y., Xiu, L., et al. (2012) · PROTEOMICS · doi:10.1002/pmic.201100081 · Cited by 71
“THRASH [8], Decon2LS [9], DeconMSn [10], Hardklor [11], Bullseye [12], and DTASuperCharge [13].”
BackgroundMayampurath, A. M., Wu, Y., Segu, Z. M., Mechref, Y. S., & Tang, H. (2011) · Rapid Communications in Mass Spectrometry · doi:10.1002/rcm.5059 · Cited by 76
Self-citationGautier, V., Mouton‐Barbosa, E., Bouyssié, D., Delcourt, N., Beau, M., Girard, J., Cayrol, C., Burlet‐Schiltz, O., Monsarrat, B., & de Peredo, A. G. (2012) · Molecular & Cellular Proteomics · doi:10.1074/mcp.m111.015230 · Cited by 79
Smith, D. P., Thrash, J. C., Nicora, C., Lipton, M. S. W., Burnum-Johnson, K., Carini, P., Smith, R. D., & Giovannoni, S. J. (2013) · mBio · doi:10.1128/mbio.00133-12 · Cited by 75
Self-citationMetabolic Reprogramming during Purine Stress in the Protozoan Pathogen Leishmania donovani
Martin, J. L., Yates, P. A., Soysa, R., Alfaro, J. F., Yang, F., Burnum-Johnson, K., Petyuk, V., Weitz, K., Camp, D., Smith, R. D., et al. (2014) · PLoS Pathogens · doi:10.1371/journal.ppat.1003938 · Cited by 77
“Among the tools used were algorithms for peak-picking and for determining isotopic distributions and charge states [138].”
MethodSelf-citationGlaskin, R. S., Khatri, K., Wang, Q., Zaia, J., & Costello, C. E. (2017) · Analytical Chemistry · doi:10.1021/acs.analchem.6b04146 · Cited by 67
Characterization of Light-Absorbing Oligomers from Reactions of Phenolic Compounds and Fe(III)
Lavi, A., Lin, P., Bhaduri, B., Carmieli, R., Laskin, A., & Rudich, Y. (2017) · ACS Earth and Space Chemistry · doi:10.1021/acsearthspacechem.7b00099 · Cited by 68
Identification of Hip BMD Loss and Fracture Risk Markers Through Population-Based Serum Proteomics
Nielson, C. M., Wiedrick, J. T., Shen, J., Jacobs, J., Baker, E. S., Baraff, A. J., Piehowski, P., Lee, C. G., Baratt, A., Petyuk, V., et al. (2017) · Journal of Bone and Mineral Research · doi:10.1002/jbmr.3125 · Cited by 61
“Detection and quantification of LC-IMS-MS features with characteristic (mass, charge, LC elution time, IMS drift time and abundance) was performed using Decon2LS((18)) and FeatureFinder((19)) software tools.”
MethodSelf-citationPomraning, K., Wei, S., Karagiosis, S. A., Kim, Y., Dohnalkova, A. C., Arey, B. W., Bredeweg, E., Orr, G., Metz, T., & Baker, S. (2015) · PLoS ONE · doi:10.1371/journal.pone.0123188 · Cited by 63
“Data were acquired under the control of Thermo Xcalibur software (Thermo Scientific) and high resolution MS scans in raw data files were subjected to deisotoping using Decon2LS [25].”
MethodApplication of network smoothing to glycan LC-MS profiling
Klein, J., Carvalho, L. E., & Zaia, J. (2018) · Bioinformatics · doi:10.1093/bioinformatics/bty397 · Cited by 59
Deoxyhypusine Synthase Promotes a Pro-Inflammatory Macrophage Phenotype
Anderson‐Baucum, E. K., Piñeros, A. R., Kulkarni, A., Webb‐Robertson, B., Maier, B., Anderson, R. M., Wu, W., Tersey, S. A., Mastracci, T. L., Casimiro, I., et al. (2020) · Cell Metabolism · doi:10.1016/j.cmet.2021.08.003 · Cited by 61
Pressurized Pepsin Digestion in Proteomics
López‐Ferrer, D., Pétritis, K., Robinson, E. W., Hixson, K. K., Tian, Z., Lee, J. H., Lee, S., Tolić, N., Weitz, K., Belov, M. E., et al. (2010) · Molecular & Cellular Proteomics · doi:10.1074/mcp.m110.001479 · Cited by 54
“T FTICR mass spectrometer proteins and peptides were identified using an in-house software that deisotoped the data (ICR2LS, Decon2ls) (33) and matched the theoretically generated protein/peptide masses to the masses obtained experimentally.”
MethodSelf-citationRasmussen, A. L., Diamond, D. L., McDermott, J., Gao, X., Metz, T., Matzke, M. M., Carter, V. S., Belisle, S. E., Korth, M. J., Waters, K. M., et al. (2011) · Journal of Virology · doi:10.1128/jvi.05605-11 · Cited by 53
“The first step involved deisotoping of the raw MS data to give the monoisotopic mass, charge state, and intensity of the major peaks in each mass spectrum using Decon2LS (18).”
MethodSelf-citationTsai, T., Wang, M., Poto, C. D., Hu, Y., Zhou, S., Zhao, Y. C., Varghese, R. S., Luo, Y., Tadesse, M. G., Ziada, D. H., et al. (2014) · Journal of Proteome Research · doi:10.1021/pr500460k · Cited by 61
Yugandhar, K., Gupta, S., & Yu, H. (2019) · Computational and Structural Biotechnology Journal · doi:10.1016/j.csbj.2019.05.007 · Cited by 51
Automated annotation and quantification of glycans using liquid chromatography–mass spectrometry
Yu, C., Mayampurath, A. M., Hu, Y., Zhou, S., Mechref, Y. S., & Tang, H. (2013) · Bioinformatics · doi:10.1093/bioinformatics/btt190 · Cited by 48
Self-citationConfident Assignment of Site-Specific Glycosylation in Complex Glycoproteins in a Single Step
Khatri, K., Staples, G. O., Leymarie, N., Leon, D. R., Turiák, L., Huang, Y., Yip, S. H., Hu, H., Heckendorf, C. F., & Zaia, J. (2014) · Journal of Proteome Research · doi:10.1021/pr500506z · Cited by 47
Sorensen, C. M., Ding, J., Zhang, Q., Alquier, T., Zhao, R., Mueller, P. W., Smith, R. D., & Metz, T. (2010) · Clinical Biochemistry · doi:10.1016/j.clinbiochem.2010.04.075 · Cited by 54
“The first step involved deisotoping of the raw MS data to give the monoisotopic mass, charge state, and intensity of the major peaks in each mass spectrum using Decon2LS [16].”
MethodSelf-citationHoekman, B., Breitling, R., Suits, F., Bischoff, R., & Horvatovich, P. L. (2012) · Molecular & Cellular Proteomics · doi:10.1074/mcp.m111.015974 · Cited by 46
“…to the two main modules of feature quantification and matching, there are optional modules such as noise filtering to improve feature detection/quantification or to remove redundancy of related features in the final quantitative matched feature matrix through decharging and deisotoping (29, 30).”
BackgroundHu, Y., Zhou, S., Yu, C., Tang, H., & Mechref, Y. S. (2014) · Rapid Communications in Mass Spectrometry · doi:10.1002/rcm.7093 · Cited by 45
Ouyang, Y., Zeng, Y., Rong, Y., Song, Y., Shi, L., Chen, B., Yang, X., Xu, N., Linhardt, R. J., & Zhang, Z. (2015) · Analytical Chemistry · doi:10.1021/acs.analchem.5b02218 · Cited by 46
Phase-Constrained Spectrum Deconvolution for Fourier Transform Mass Spectrometry
Grinfeld, D., Aizikov, K., Kreutzmann, A., Damoc, E., & Makarov, A. (2016) · Analytical Chemistry · doi:10.1021/acs.analchem.6b03636 · Cited by 45
Mayne, S. L. N., & Patterton, H. (2011) · Briefings in Bioinformatics · doi:10.1093/bib/bbq087 · Cited by 43
Machine learning based prediction for peptide drift times in ion mobility spectrometry
Shah, A. R., Agarwal, K., Baker, E. S., Singhal, M., Mayampurath, A. M., Ibrahim, Y., Kangas, L. J., Monroe, M. E., Zhao, R., Belov, M. E., et al. (2010) · Bioinformatics · doi:10.1093/bioinformatics/btq245 · Cited by 42
Self-citationDichomitus squalens partially tailors its molecular responses to the composition of solid wood
Daly, P., López, S. C., Peng, M., Lancefield, C. S., Purvine, S. O., Kim, Y., Zink, E., Dohnalkova, A. C., Singan, V. R., Lipzen, A., et al. (2018) · Environmental Microbiology · doi:10.1111/1462-2920.14416 · Cited by 46
“LC – MS data were deisotoped using Decon2LS (Jaitly et al ., 2009), and eluting LC – MS features were grouped using MS Feature Finder (Crowell et al ., 2013) with abundance information for each feature extracted as the sum of monoisotope abundances for each grouped feature.”
MethodMolecular Composition and the Optical Properties of Brown Carbon Generated by the Ethane Flame
West, C. P., Hettiyadura, A. P. S., Darmody, A., Mahamuni, G., Davis, J., Novosselov, I. V., & Laskin, A. (2020) · ACS Earth and Space Chemistry · doi:10.1021/acsearthspacechem.0c00095 · Cited by 47
Merkley, E. D., Baker, E. S., Crowell, K. L., Orton, D., Taverner, T., Ansong, C. K., Ibrahim, Y., Burnet, M., Cort, J., Anderson, G., et al. (2013) · Journal of the American Society for Mass Spectrometry · doi:10.1007/s13361-012-0565-x · Cited by 40
“Raw LC-IMS-MS data were processed with Decon2LS [19], and LC-IMS-MS Feature Finder [20] was used to group isotopic profiles across LC elution time and drift time into features (peaks in the elution time/drift time/mass space representing distinct chemical species).”
MethodSelf-citationPreprocessing and Analysis of LC-MS-Based Proteomic Data
Tsai, T., Wang, M., & Ressom, H. W. (2015) · Methods in molecular biology · doi:10.1007/978-1-4939-3106-4_3 · Cited by 43
“DeconTools [13] is widely used to deisotope MS spectra, which involves: (1) identification of isotopic pattern, (2) prediction of the charge state based on the distance between the ion peaks, and (3) comparison between the observed isotopic pattern and a theoretical distribution generated based on an average residue.”
MethodMetabolite aberrations in early diabetes detected in rat kidney using mass spectrometry imaging
Bergman, H., Lindfors, L., Palm, F., Kihlberg, J. O., & Lanekoff, I. (2019) · Analytical and Bioanalytical Chemistry · doi:10.1007/s00216-019-01721-5 · Cited by 41
Bayesian Proteoform Modeling Improves Protein Quantification of Global Proteomic Measurements
Webb-Robertson, B.-J. M., Matzke, M. M., Datta, S., Payne, S. H., Kang, J., Bramer, L. M., Nicora, C. D., Shukla, A. K., Metz, T. O., Rodland, K. D., et al. (2014) · Molecular & Cellular Proteomics · doi:10.1074/mcp.m113.030932 · Cited by 41
“The first step involved deisotoping of the raw MS data to give the monoisotopic mass, charge state, and intensity of the major peaks in each mass spectrum (22).”
BackgroundMethodSelf-citationThe human brainome: network analysis identifies HSPA2 as a novel Alzheimer’s disease target
Petyuk, V. A., Chang, R., Ramirez-Restrepo, M., Beckmann, N. D., Henrion, M. Y. R., Piehowski, P. D., Zhu, K., Wang, S., Clarke, J., Huentelman, M. J., et al. (2018) · Brain · doi:10.1093/brain/awy215 · Cited by 42
“Decon2LS was used for peak-picking and for determining isotopic distributions and charge states (Jaitly et al., 2009).”
MethodSelf-citationCrowell, K. L., Slysz, G., Baker, E. S., Lamarche, B. L., Monroe, M. E., Ibrahim, Y., Payne, S., Anderson, G., & Smith, R. D. (2013) · Bioinformatics · doi:10.1093/bioinformatics/btt465 · Cited by 37
“More recently, ion mobility spectrom- etry (IMS) has been added as an extra dimension of separation to further enhance sensitivity (Baker et al., 2010; Lee et al., 2002; Liu et al., 2004).”
BackgroundSelf-citationBurnum-Johnson, K., Nie, S., Casey, C., Monroe, M. E., Orton, D., Ibrahim, Y., Gritsenko, M. A., Clauss, T. R., Shukla, A. K., Moore, R., et al. (2016) · Molecular & Cellular Proteomics · doi:10.1074/mcp.m116.061143 · Cited by 40
“gov/software) with algorithms for peak-picking and determining isotopic distributions and charge states for feature definition (30).”
MethodSelf-citationKhadempour, L., Burnum-Johnson, K., Baker, E. S., Nicora, C., Webb‐Robertson, B., White, R. A., III, Monroe, M. E., Huang, E. L., Smith, R. D., & Currie, C. R. (2016) · Molecular Ecology · doi:10.1111/mec.13872 · Cited by 44
“Multiple in-house developed (Monroe et al. 2007; Jaitly et al. 2009) informatics tools (A) (B) (C)”
MethodSelf-citationComprehensive N-Glycome Profiling of Cells and Tissues for Breast Cancer Diagnosis
Li, Q., Li, G., Zhou, Y., Zhang, X., Sun, M., Jiang, H., & Yu, G. (2019) · Journal of Proteome Research · doi:10.1021/acs.jproteome.9b00073 · Cited by 36
Manes, N. P., Dong, L., Zhou, W., Du, X., Reghu, N., Kool, A. C., Choi, D., Bailey, C. L., Petricoin, E. F., Liotta, L. A., et al. (2011) · Molecular & Cellular Proteomics · doi:10.1074/mcp.m110.000927 · Cited by 36
“gov/software/) (56), an implementation of the THRASH algorithm (41).”
MethodUterine Deletion of Trp53 Compromises Antioxidant Responses in the Mouse Decidua
Burnum-Johnson, K., Hirota, Y., Baker, E. S., Yoshie, M., Ibrahim, Y., Monroe, M. E., Anderson, G., Smith, R. D., Daikoku, T., & Dey, S. K. (2012) · Endocrinology · doi:10.1210/en.2012-1335 · Cited by 37
“Among the tools used were algorithms for peak-picking and for determining isotopic distributions and charge states (24).”
MethodSelf-citationKhatri, K., Klein, J., & Zaia, J. (2016) · Analytical and Bioanalytical Chemistry · doi:10.1007/s00216-016-9970-5 · Cited by 35
Ansong, C. K., Tolić, N., Purvine, S. O., Porwollik, S., Jones, M. B., Yoon, H., Payne, S., Martin, J. L., Burnet, M., Monroe, M. E., et al. (2011) · BMC Genomics · doi:10.1186/1471-2164-12-433 · Cited by 37
“Note, Decon2LS is publically available at omics.pnl. gov [86].”
MethodSelf-citationIncreasing confidence of LC–MS identifications by utilizing ion mobility spectrometry
Crowell, K. L., Baker, E. S., Payne, S., Ibrahim, Y., Monroe, M. E., Slysz, G., Lamarche, B. L., Petyuk, V., Piehowski, P., Danielson, W., et al. (2013) · International Journal of Mass Spectrometry · doi:10.1016/j.ijms.2013.06.028 · Cited by 33
Self-citationAdvances in structure elucidation of small molecules using mass spectrometry
Kind, T., & Fiehn, O. (2010) · Springer eBooks · doi:10.1007/978-3-642-36303-0_7 · Cited by 37
A perspective view of top‐down proteomics in snake venom research
Ghezellou, P., Garikapati, V., Kazemi, S. M., Strupat, K., Ghassempour, A., & Spengler, B. (2018) · Rapid Communications in Mass Spectrometry · doi:10.1002/rcm.8255 · Cited by 38
MultiAlign: a multiple LC-MS analysis tool for targeted omics analysis
Lamarche, B. L., Crowell, K. L., Jaitly, N., Petyuk, V., Shah, A. R., Polpitiya, A. D., Sandoval, J. D., Kiebel, G. R., Monroe, M. E., Callister, S., et al. (2013) · BMC Bioinformatics · doi:10.1186/1471-2105-14-49 · Cited by 31
“Respective isotopic distributions of ionized peptides can be resolved to a single monoisotopic mass after normalizing by charge [4,5,8], which results in an MS feature.”
BackgroundMethodSelf-citationIbrahim, Y., Prior, D. C., Baker, E. S., Smith, R. D., & Belov, M. E. (2010) · International Journal of Mass Spectrometry · doi:10.1016/j.ijms.2010.03.009 · Cited by 38
“A list of peaks was then generated for each mass spectrum using Decon2LS software developed in-house [35, 36].”
MethodSelf-citationChang, H.-Y., Chen, C.-T., Lih, T. M., Lynn, K., Juo, C., Hsu, W.-L., & Sung, T.-Y. (2016) · PLoS ONE · doi:10.1371/journal.pone.0146112 · Cited by 30
Zaia, J., Khatri, K., Klein, J., Chun, S., Sheng, Y., & Viner, R. (2016) · Analytical Chemistry · doi:10.1021/acs.analchem.6b03081 · Cited by 31
Bouyssié, D., Dubois, M., Nasso, S., de Peredo, A. G., Burlet‐Schiltz, O., Aebersold, R. H., & Monsarrat, B. (2014) · Molecular & Cellular Proteomics · doi:10.1074/mcp.o114.039115 · Cited by 34
“To tackle these issues, some independent laboratories developed open formats relying on binary specifications (14, 17, 20, 21), to optimize both file size and data processing performance.”
MethodPena, A. B., Gibbons, B. C., Slysz, G., Crowell, K. L., Monroe, M. E., Ibrahim, Y., Smith, R. D., Payne, S., & Baker, E. S. (2017) · International Journal of Mass Spectrometry · doi:10.1016/j.ijms.2017.11.003 · Cited by 32
“Raw MS files in the Unified Ion Mobility Frame (UIMF) file format [24] were processed by DeconTools [25,26], where the saturation correction was integrated.”
Self-citationEvaluating LC-HRMS metabolomics data processing software using FAIR principles for research software
Du, X., Dastmalchi, F., Ye, H., Garrett, T. J., Diller, M. A., Liu, M., Hogan, W. R., Brochhausen, M., & Lemas, D. J. (2023) · Metabolomics · doi:10.1007/s11306-023-01974-3 · Cited by 27
“…2015 ; Guo et al., 2021 ; Helmus et al., 2021 ; Huan & Li, 2015a, b ; Huang et al., 2014 ; F. Huber, Ridder, et al., 2021 ; Hughes et al., 2014 ; Jaitly et al., 2009 ; Ji et al., 2017 , 2019 ; Kantz et al., 2019 ; Kuhl et al., 2012 ; Kutuzova et al., 2020 ; Li et al., 2017; Libiseller et al.,…”
O’Brien, R. E., Nguyen, T. B., Laskin, A., Laskin, J., Hayes, P. L., Liu, S., Jimenez, J. L., Russell, L. M., Nizkorodov, S. A., & Goldstein, A. H. (2013) · Journal of Geophysical Research Atmospheres · doi:10.1002/jgrd.50119 · Cited by 28
Comprehensive Quantitative Analysis of Ovarian and Breast Cancer Tumor Peptidomes
Xu, Z., Wu, C., Xie, F., Slysz, G., Tolić, N., Monroe, M. E., Petyuk, V., Payne, S., Fujimoto, G. M., Moore, R., et al. (2014) · Journal of Proteome Research · doi:10.1021/pr500840w · Cited by 29
Self-citationSelection of the optimum electrospray voltage for gradient elution LC-MS measurements
Marginean, I., Kelly, R., Moore, R., Prior, D. C., Lamarche, B. L., Tang, K., & Smith, R. D. (2008) · Journal of the American Society for Mass Spectrometry · doi:10.1016/j.jasms.2008.12.004 · Cited by 28
“Decon2LS [16] and MultiAlign [17], open-source pro-”
Self-citationHogan, J., Klein, J., Wu, J., Chopra, P., Boons, G., Carvalho, L. E., Lin, C., & Zaia, J. (2018) · Molecular & Cellular Proteomics · doi:10.1074/mcp.ra118.000590 · Cited by 28
“In the proteomics domain, several computational methods for automatic recognition of isotopic patterns and assignment of charge states and neutral mass values have been developed, including THRASH (11), Decon2LS (12), and MS-Deconv (13), among others.”
MethodUncovering hidden protein modifications with native top-down mass spectrometry
Bennett, J. L., El‐Baba, T. J., Zouboulis, K., Kirschbaum, C., Song, H., Butroid, F. I., Benesch, J. L. P., Lutomski, C. A., & Robinson, C. V. (2025) · Nature Methods · doi:10.1038/s41592-025-02846-5 · Cited by 30
“After deconvolution, isotopic envelopes corresponding to protein fragment ions are identified using two established algorithms, THRASH 35,36 and TopFD 34 .”
Ion annotation-assisted analysis of LC-MS based metabolomic experiment
Varghese, R. S., Zhou, B., Ranjbar, M., Zhao, Y., & Ressom, H. W. (2012) · Proteome Science · doi:10.1186/1477-5956-10-s1-s8 · Cited by 30
“Decon2LS [12] works on the raw data instead of the peak list.”
Background
Metadata
- Authors
- Jaitly, N., Mayampurath, A., Littlefield, K., Adkins, J. N., Anderson, G. A., & Smith, R. D.
- Affiliations
- Pacific Northwest National Laboratory (US)
- Corresponding author
- Smith, Richard D
- Venue
- BMC Bioinformatics
- Published
- 2009-03-17
- Volume
- 10
- Issue
- 1
- Pages
- 87-87
- ISSN
- 1471-2105 (ISSN-L)
- PMC
- PMC2666663
- OpenAlex
- W2014186056
- Cited by
- 217
- References
- 26
- Citations by year
- 2026: 7 · 2025: 4 · 2024: 6 · 2023: 5 · 2022: 4 · 2021: 3 · 2020: 11 · 2019: 9 · 2018: 12 · 2017: 12 · 2016: 18 · 2015: 15 · 2014: 23 · 2013: 23 · 2012: 19
- FWCI
- 8.73
- Type
- journal article
- Language
- en
- Open access
- gold
- doi.org
- Licence
- cc-by
- Locations
- BMC Bioinformatics (publishedVersion, cc-by)
- PubMed Central (publishedVersion, cc-by)
- PubMed (publishedVersion)
- TSpace (University of Toronto) (submittedVersion)
- DOAJ (DOAJ: Directory of Open Access Journals) (submittedVersion)
- Funders
- U.S. Department of Energy (RR018522, DE-AC05?, 76RLO 1830, DE‐AC05‐76RLO1830)
- Battelle (DE-AC05, DE‐AC05‐76RLO 1830)
- National Institutes of Health
- National Center for Research Resources (P41RR018522, RR-018522)
- Biological and Environmental Research (DE-AC05-76RLO-1830, RR018522)
- Pacific Northwest National Laboratory (DE-AC05-76RLO 1830)
- Topics
- Life Sciences › Biochemistry, Genetics and Molecular Biology › Molecular Biology › Metabolomics and Mass Spectrometry Studies
- Physical Sciences › Chemistry › Spectroscopy › Advanced Proteomics Techniques and Applications
- Physical Sciences › Chemistry › Spectroscopy › Mass Spectrometry Techniques and Applications
- Keywords
- high-resolution mass spectrometry, LC-MS data processing, peak detection, proteomics, peptide identification, open source software
- MeSH terms
- Algorithms, Chromatography, Liquid, Software, Mass Spectrometry, Proteomics
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.