Optimizing transformations for automated, high throughput analysis of flow cytometry data
Open accessThe DOI matches its Crossref record; 27 of the 27 references it cites were found in a registry or an index.
Abstract
BACKGROUND: In a high throughput setting, effective flow cytometry data analysis depends heavily on proper data preprocessing. While usual preprocessing steps of quality assessment, outlier removal, normalization, and gating have received considerable scrutiny from the community, the influence of data transformation on the output of high throughput analysis has been largely overlooked. Flow cytometry measurements can vary over several orders of magnitude, cell populations can have variances that depend on their mean fluorescence intensities, and may exhibit heavily-skewed distributions. Consequently, the choice of data transformation can influence the output of automated gating. An appropriate data transformation aids in data visualization and gating of cell populations across the range of data. Experience shows that the choice of transformation is data specific. Our goal here is to compare the performance of different transformations applied to flow cytometry data in the context of automated gating in a high throughput, fully automated setting. We examine the most common transformations used in flow cytometry, including the generalized hyperbolic arcsine, biexponential, linlog, and generalized Box-Cox, all within the BioConductor flowCore framework that is widely used in high throughput, automated flow cytometry data analysis. All of these transformations have adjustable parameters whose effects upon the data are non-intuitive for most users. By making some modelling assumptions about the transformed data, we develop maximum likelihood criteria to optimize parameter choice for these different transformations. RESULTS: We compare the performance of parameter-optimized and default-parameter (in flowCore) data transformations on real and simulated data by measuring the variation in the locations of cell populations across samples, discovered via automated gating in both the scatter and fluorescence channels. We find that parameter-optimized transformations improve visualization, reduce variability in the location of discovered cell populations across samples, and decrease the misclassification (mis-gating) of individual events when compared to default-parameter counterparts. CONCLUSIONS: Our results indicate that the preferred transformation for fluorescence channels is a parameter- optimized biexponential or generalized Box-Cox, in accordance with current best practices. Interestingly, for populations in the scatter channels, we find that the optimized hyperbolic arcsine may be a better choice in a high-throughput setting than current standard practice of no transformation. However, generally speaking, the choice of transformation remains data-dependent. We have implemented our algorithm in the BioConductor package, flowTrans, which is publicly available.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Figures






Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
The source backs part of the claim, not all of it — or backs it for a different population, condition or comparison.
In the citing paper
“Different transformation approaches such as the biexponential, arcsinh, and hyperlog display can be used, and the optimal transformation depends on the specific data and cannot always be computationally predicted [83].”
From Guidelines for the use of flow cytometry and cell sorting in immunological studies (third edition) (2021) · cites this paper as [83]
Experimental — accuracy not yet measured
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
An Analysis of Transformations
Box, G. E. P., & Cox, D. R. (1964) · Journal of the Royal Statistical Society Series B: Statistical Methodology · doi:10.1111/j.2517-6161.1964.tb00553.x · Cited by 15,052 · cited 1×
“We use maximum likelihood methods to estimate the parameters of each transformation (generalized arcsinh, generalized Box-Cox, linlog, and biexponential) following established methods [19].”
MethodBioconductor: open software development for computational biology and bioinformatics
Gentleman, R. C., Carey, V. J., Bates, D. M., Bolstad, B., Dettling, M., Dudoit, S., Ellis, B., Gautier, L., Ge, Y., Gentry, J., et al. (2004) · Genome Biology · doi:10.1186/gb-2004-5-10-r80 · Cited by 12,172 · cited 3×
“We perform our analysis within the flowCore framework in BioConductor, which is the predominant tool set in use for automated, high throughput flow data analysis.”
MethodR: A Language for Data Analysis and Graphics
Ihaka, R., & Gentleman, R. (1996) · Journal of Computational and Graphical Statistics · doi:10.1080/10618600.1996.10474713 · Cited by 11,220
On the generalized distance in statistics
Mahalanobis, P. C. (1936) · DOAJ (DOAJ: Directory of Open Access Journals) · Cited by 6,068
Hierarchical Clustering Schemes
Johnson, S. C. (1967) · Psychometrika · doi:10.1007/bf02289588 · Cited by 4,897 · cited 1×
“This involved a modified single linkage agglomerative clustering approach to group corresponding populations across samples [23].”
MethodR: A Language for Data Analysis and Graphics
Ihaka, R., & Gentleman, R. C. (1996) · Journal of Computational and Graphical Statistics · doi:10.2307/1390807 · Cited by 4,245
flowCore: a Bioconductor package for high throughput flow cytometry
Hahne, F., LeMeur, N., Brinkman, R. R., Ellis, B., Haaland, P., Sarkar, D., Spidlen, J., Strain, E., & Gentleman, R. (2009) · BMC Bioinformatics · doi:10.1186/1471-2105-10-106 · Cited by 581 · cited 1×
“This package integrates with the existing FCM data analysis tools in BioConductor and uses existing data structures data manipulation paradigms from the flowCore framework [22,25].”
MethodInterpreting flow cytometry data: a guide for the perplexed
Herzenberg, L. A., Tung, J., Moore, W. A., Herzenberg, L. A., & Parks, D. R. (2006) · Nature Immunology · doi:10.1038/ni0706-681 · Cited by 464 · cited 1×
“The underpinning principle is to choose a transformation that facilitates cell population gating, visualization, and intersample comparison, by obtaining a representation wherein cell populations are well resolved across the full range of the data [6,12,15-17].”
BackgroundAutomated high-dimensional flow cytometric data analysis
Pyne, S., Hu, X., Wang, K., Rossin, E., Lin, T.-I., Maier, L. M., Baecher-Allan, C., McLachlan, G. J., Tamayo, P., Hafler, D. A., et al. (2009) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.0903028106 · Cited by 285 · cited 2×
“Background Flow cytometry (FCM) is increasingly moving to-wards automated methods to deal with the quantities of data generated by high throughput, high-content screening [1-11].”
MethodAutomated gating of flow cytometry data via robust model‐based clustering
Lo, K., Brinkman, R. R., & Gottardo, R. (2008) · Cytometry Part A · doi:10.1002/cyto.a.20531 · Cited by 264 · cited 10×
“Background Flow cytometry (FCM) is increasingly moving to-wards automated methods to deal with the quantities of data generated by high throughput, high-content screening [1-11].”
BackgroundMethodInfluentialSelf-citation
Cited by
Guidelines for the use of flow cytometry and cell sorting in immunological studies (second edition)
Cossarizza, A., Chang, H., Radbruch, A., Acs, A., Adam, D., Adam‐Klages, S., Agace, W. W., Aghaeepour, N., Akdis, M., Allez, M., et al. (2019) · European Journal of Immunology · doi:10.1002/eji.201970107 · Cited by 979
Guidelines for the use of flow cytometry and cell sorting in immunological studies *
Cossarizza, A., Chang, H., Radbruch, A., Akdis, M., Andrä, I., Annunziato, F., Bacher, P., Barnaba, V., Battistini, L., Bauer, W. M., et al. (2017) · European Journal of Immunology · doi:10.1002/eji.201646632 · Cited by 542
Guidelines for the use of flow cytometry and cell sorting in immunological studies (third edition)
Cossarizza, A., Chang, H., Radbruch, A., Abrignani, S., Addo, R., Akdis, M., Andrä, I., Andreata, F., Annunziato, F., Arranz, E., et al. (2021) · European Journal of Immunology · doi:10.1002/eji.202170126 · Cited by 531
The end of gating? An introduction to automated analysis of high dimensional cytometry data
Mair, F., Hartmann, F. J., Mrdjen, D., Tosevski, V., Krieg, C., & Becher, B. (2016) · European Journal of Immunology · doi:10.1002/eji.201545774 · Cited by 234
Immune monitoring using mass cytometry and related high-dimensional imaging approaches
Hartmann, F. J., & Bendall, S. C. (2020) · Nature Reviews Rheumatology · doi:10.1038/s41584-019-0338-z · Cited by 200
Brummelman, J., Haftmann, C., Núñez, N. G., Alvisi, G., Mazza, E. M. C., Becher, B., & Lugli, E. (2019) · Nature Protocols · doi:10.1038/s41596-019-0166-2 · Cited by 195
Human germinal center transcriptional programs are de-synchronized in B cell lymphoma
Milpied, P., Cervera-Marzal, I., Mollichella, M.-L., Tesson, B. M., Brisou, G., Traverse‐Glehen, A., Salles, G. A., Spinelli, L., & Nadel, B. (2018) · Nature Immunology · doi:10.1038/s41590-018-0181-4 · Cited by 179
The anatomy of single cell mass cytometry data
Olsen, L. R., Leipold, M. D., Pedersen, C. B., & Maecker, H. T. (2018) · Cytometry Part A · doi:10.1002/cyto.a.23621 · Cited by 116
“Traditionally, flow cytometry data is transformed using a biexponential distribution (95), but ArcSinh with a co-factor of around 150 can also be used.”
MethodO’Neill, K., Aghaeepour, N., Špidlen, J., & Brinkman, R. R. (2013) · PLoS Computational Biology · doi:10.1371/journal.pcbi.1003365 · Cited by 106
“A comparison of commonly used transformations concluded that the biexponential and Box-Cox transformations, when optimally parameterized, provided the clearest visualization and least variance of cell populations across samples [17].”
BackgroundMethodHigh Throughput Multi-Omics Approaches for Clinical Trial Evaluation and Drug Discovery
Zielinski, J., Luke, J. J., Guglietta, S., & Krieg, C. (2021) · Frontiers in Immunology · doi:10.3389/fimmu.2021.590742 · Cited by 87
“To date, several software solutions are available to normalize fluorescence values between data sets (4, 5).”
BackgroundFlow cytometry data analysis: Recent tools and algorithms
Montante, S., & Brinkman, R. R. (2019) · International Journal of Laboratory Hematology · doi:10.1111/ijlh.13016 · Cited by 88
“15 For this reason, other transformations can be applied, including the linear-logarithmic (linlog) transformation, the biexponential (logicle), 15 generalized arcsinh transformations, and the generalized Box-Cox transformation.”
BackgroundMethodInfluentialGrégoire, C., Spinelli, L., Villazala‐Merino, S., Gil, L., Holgado, M. P., Moussa, M., Dong, C., Zarubica, A., Fallet, M., Navarro, J., et al. (2022) · Immunity · doi:10.1016/j.immuni.2022.06.002 · Cited by 80
O'Gorman, W. E., Hsieh, E. W. Y., Savig, E. S., Gherardini, P. F., Hernandez, J. D., Hansmann, L., Balboni, I. M., Utz, P. J., Bendall, S. C., Fantl, W. J., et al. (2015) · Journal of Allergy and Clinical Immunology · doi:10.1016/j.jaci.2015.04.008 · Cited by 73
“The arcsinh scale, a bioexponential transformation used with flow cytometric data, was chosen over a traditional log scale to account for negative values.(32) For each cell type and signaling protein, expression values for that signaling protein in the stimulated and unstimulated conditions were paired according to th…”
MethodZhang, X., Li, B., Xu, H. Y., Wells, M., Tefsen, B., & Qin, B. (2018) · Water Research · doi:10.1016/j.watres.2018.12.023 · Cited by 66
den Braanker, H., Bongenaar, M., & Lubberts, E. (2021) · Frontiers in Immunology · doi:10.3389/fimmu.2021.768113 · Cited by 62
“We used the arcsinh transformation, as it is widely used for computational analysis of flow cytometry data (22).”
BackgroundMethodInfluentialMelsen, J. E., Dam, M. M. V. O.-T., Lankester, A. C., Schilham, M. W., & van den Akker, E. B. (2020) · The Journal of Immunology · doi:10.4049/jimmunol.1901530 · Cited by 53
“The quality of the transformation of the data has a major impact on the downstream analyses (30).”
BackgroundMethodComputational analysis of high-throughput flow cytometry data
Robinson, J. P., Rajwa, B. P., Patsekin, V., & Davisson, V. J. (2012) · Expert Opinion on Drug Discovery · doi:10.1517/17460441.2012.693475 · Cited by 49
“The R/Bioconductor package flowTrans offers help and assistance in the search for optimal transformations for subsequent data processing and visualization [87].”
MethodflowVS: channel-specific variance stabilization in flow cytometry
Azad, A., Rajwa, B. P., & Pothen, A. (2016) · BMC Bioinformatics · doi:10.1186/s12859-016-1083-9 · Cited by 56
“In past work, parameters of these transformations were adjusted in a data-driven manner to maximize the likelihood (flowTrans by Finak et al. [27]), to satisfy the normality (flowScape by Ray et al. [28]), and to comply with simulations (FCSTrans by Qian et al. [36]). flowTrans estimates…”
BackgroundMethodInfluentialComputational Analysis of Microbial Flow Cytometry Data
Rubbens, P., & Props, R. (2021) · mSystems · doi:10.1128/msystems.00895-20 · Cited by 42
“Preprocessing flowCore (30) Basic data manipulation, gating, compensation, and transformation 12, 72–74 Preprocessing flowTrans (37) Optimized individual channel transformations Preprocessing flowAI (42) Automated denoising 75, 76 Preprocessing flowClean (41) Automated denoising Preprocessing flowStats (77) Per-channe…”
BackgroundMethodANPELA: Significantly Enhanced Quantification Tool for Cytometry‐Based Single‐Cell Proteomics
Zhang, Y., Sun, H., Lian, X., Tang, J., & Zhu, F. (2023) · Advanced Science · doi:10.1002/advs.202207061 · Cited by 36
Rybakowska, P., Alarcón-Riquelme, M. E., & Marañón, C. (2020) · Computational and Structural Biotechnology Journal · doi:10.1016/j.csbj.2020.03.024 · Cited by 35
“The type of transformation can be sample and marker-specific, especially in FC data, as shown in [58,59], and the choice of parameters can be automatically optimized by tools like flowTrans and flowVS.”
MethodGuidelines for Gating Flow Cytometry Data for Immunological Assays
Staats, J. S., Divekar, A., McCoy, J. P., & Maecker, H. T. (2019) · Methods in molecular biology · doi:10.1007/978-1-4939-9650-6_5 · Cited by 46
Wearing-off at the end of natalizumab dosing intervals is associated with low receptor occupancy
Bringeland, G. H., Blaser, N., Myhr, K., Vedeler, C. A., & Gavasso, S. (2020) · Neurology Neuroimmunology & Neuroinflammation · doi:10.1212/nxi.0000000000000678 · Cited by 37
“We performed clean-up gating to obtain single PBLs, and the data were arcsinh transformed with a scale argument of 5.(13) We then performed 2 independent analyses for RO calculation in single PBLs: one was a manual analysis, and one used an unsupervised approach.”
MethodWeber, L. M., & Soneson, C. (2019) · F1000Research · doi:10.12688/f1000research.20210.2 · Cited by 34
Hsiao, C. J., Liu, M., Stanton, R., McGee, M., Yu, Q., & Scheuermann, R. H. (2015) · Cytometry Part A · doi:10.1002/cyto.a.22735 · Cited by 24
“Finak et al. (13) compared sample-level variability in cell population marker expression among fluorescent channel transformation methods (e.g., bi-exponential or generalized Box-Cox).”
MethodAzad, A., Rajwa, B. P., & Pothen, A. (2016) · Frontiers in Oncology · doi:10.3389/fonc.2016.00188 · Cited by 24
“APL is subtype M3 in the FAB classification of AML (51) and is characterized by chromosomal translocation of retinoic acid receptor-alpha (RARα) gene on chromosome 17 with the promyelocytic leukemia gene (PML) on chromosome 15, a translocation denoted as t(15;17).”
BackgroundMethodInfluentialDetermination of essential phenotypic elements of clusters in high-dimensional entities—DEPECHE
Theorell, A., Bryceson, Y. T., & Theorell, J. (2019) · PLoS ONE · doi:10.1371/journal.pone.0203247 · Cited by 24
Hunter, B., Nicorescu, I., Foster, E., McDonald, D., Hulme, G., Fuller, A., Thomson, A., Goldsborough, T., Hilkens, C. M. U., Majo, J., et al. (2023) · Cytometry Part A · doi:10.1002/cyto.a.24803 · Cited by 22
“To our knowledge, however, there have been minimal attempts to empirically prove why these values have been used in either technology [29] or, importantly, any attempts to determine what co factor is optimal for IMC data.”
BackgroundUltra-high throughput single-cell analysis of proteins and RNAs by split-pool synthesis
O’Huallachain, M., Bava, F.-A., Shen, M., Dallett, C., Paladugu, S. R., Samusik, N., Yu, S., Hussein, R., Hillman, G. R., Higgins, S., et al. (2020) · Communications Biology · doi:10.1038/s42003-020-0896-2 · Cited by 20
FCSTrans: An open source software system for FCS file conversion and data transformation
Yu, Q., Liu, Y., Campbell, J. P., Thomson, E., Kong, Y. M., & Scheuermann, R. H. (2012) · Cytometry Part A · doi:10.1002/cyto.a.22037 · Cited by 18
High‐throughput precision measurement of subcellular localization in single cells
Burns, T. J., Frei, A. P., Gherardini, P. F., Bava, F.-A., Batchelder, J. E., Yoshiyasu, Y., Yu, J. M., Groziak, A. R., Kimmey, S. C., Gonzalez, V. D., et al. (2017) · Cytometry Part A · doi:10.1002/cyto.a.23054 · Cited by 19
Statistical file matching of flow cytometry data
Lee, G., Finn, W. G., & Scott, C. D. (2011) · Journal of Biomedical Informatics · doi:10.1016/j.jbi.2011.03.004 · Cited by 16
“To minimize the effects from this variation, data files can be preprocessed with normalization techniques [20, 21] before applying file matching algorithms.”
MethodLucchesi, S., Furini, S., Medaglini, D., & Ciabattini, A. (2020) · Vaccines · doi:10.3390/vaccines8010138 · Cited by 18
“Data transformation plays an important role in mitigating these effects [51].”
BackgroundHong, H., Gao, M., Wu, Q., Yang, P., Liu, S., Li, H., Burrows, P. D., Cua, D., Chen, J. Y., Hsu, H., et al. (2020) · The Journal of Immunology · doi:10.4049/jimmunol.2000280 · Cited by 14
“The axis labels to show that this indicates relative expression of the indicated genes on a heperbolic arcsine (Arcsinh) transformation scale (48, 49).”
BackgroundA Computational Framework to Emulate the Human Perspective in Flow Cytometric Data Analysis
Ray, S., & Pyne, S. (2012) · PLoS ONE · doi:10.1371/journal.pone.0035693 · Cited by 15
“While transformations such as bi-exponential (e.g. logicle by Parks et al. [34]) or generalized inverse sine hyperbolic (Arcsinh) are quite useful for flow data, the task of optimizing the resulting display is finally based on the correct choice of the transformation parameters [10].”
BackgroundTong, D. L., Ball, G., & Pockley, A. G. (2015) · Cytometry Part A · doi:10.1002/cyto.a.22622 · Cited by 13
Folcarelli, R., van Staveren, S., Tinnevelt, G. H., Cadot, E., Vrisekoop, N., Buydens, L. M. C., Koenderman, L., Jansen, J. J., & van den Brink, O. F. (2021) · Cytometry Part A · doi:10.1002/cyto.a.24491 · Cited by 20
“The logicle [15] and hyperbolic arcsine (arcsinh) [16] transformations are the most commonly used in modern flow cytometry.”
BackgroundMethodAutomated clustering of heterotrophic bacterioplankton in flow cytometry data
García, F., López‐Urrutia, Á., & Morán, X. A. G. (2014) · Aquatic Microbial Ecology · doi:10.3354/ame01691 · Cited by 13
Computational methods for evaluation of cell-based data assessment—Bioconductor
Meur, N. L. (2012) · Current Opinion in Biotechnology · doi:10.1016/j.copbio.2012.09.003 · Cited by 11
Challenges in the Multivariate Analysis of Mass Cytometry Data: The Effect of Randomization
Παπουτσόγλου, Γ., Lagani, V., Schmidt, A., Tsirlis, K., Gómez-Cabrero, D., Tegner, J. N., & Tsamardinos, I. (2019) · Cytometry Part A · doi:10.1002/cyto.a.23908 · Cited by 13
“Therefore, the inverse hyperbolic sine (arcsinh), adjusted by a co-factor of fi ve, is most frequently used because it serves as a linear transform to abundances in the low range and as a log transform in the high range, with a smooth transition between them (20).”
MethodModeling of cytometry data in logarithmic space: When is a bimodal distribution not bimodal?
Erez, A., VOGEL, R. M., Mugler, A., Belmonte, A. L., & Altan-Bonnet, G. Y. (2018) · Cytometry Part A · doi:10.1002/cyto.a.23333 · Cited by 11
“, “Logicle” (2), “VLog” (3), and other transformations (4)).”
Castenmiller, S. M., Kanagasabesan, N., Guislain, A., Nicolet, B. P., van Loenen, M. M., Monkhorst, K., Veenhof, A. A. F. A., Smit, E. F., Hartemink, K. J., Haanen, J. B. A. G., et al. (2024) · OncoImmunology · doi:10.1080/2162402x.2024.2392898 · Cited by 9
“…follow: 1) The marker expression values were transformed using hyperbolic arcsine transformation, which linearizes near-zero values and logarithmically transforms higher positive and negative values with rrscale package (version 1) 70,76 and 2) Transformed data were then median-centered and scaled.”
MethodQuality assessment of boar semen by multivariate analysis of flow cytometric data
Babamoradi, H., Amigo, J. M., van den Berg, F. W. J., Petersen, M. R., Satake, N., & Boe-Hansen, G. B. (2015) · Chemometrics and Intelligent Laboratory Systems · doi:10.1016/j.chemolab.2015.02.008 · Cited by 9
Nollmann, C., Moskorz, W., Wimmenauer, C., Jäger, P. S., Cadeddu, R., Timm, J., Heinzel, T., & Haas, R. R. (2024) · Cancers · doi:10.3390/cancers16071320 · Cited by 7
“We We therefore selected gates representing five characteristic cellular subsets, namely gates 1, 3, 6, 12 and 26, to illustrate the possibilities, but selected gates representing five characteristic cellular subsets, namely gates 1, 3, 6, 12 and 26, to illustrate the possibilities, but also the…”
BackgroundMethodFunctional plasticity and recurrent cell states of malignant B cells in follicular lymphomaPreprint
Attaf, N., Dong, C., Gil, L., Cervera-Marzal, I., Gharsalli, T., Navarro, J., Mboumba, D.-L., Chasson, L., Lemonnier, F., Gaulard, P., et al. (2022) · bioRxiv (Cold Spring Harbor Laboratory) · doi:10.1101/2022.04.06.487285 · Cited by 10
Identification of a super-functional Tfh-like subpopulation in murine lupus by pattern perception
Gryzik, S., Hoang, Y. N. T., Lischke, T., Mohr, E., Venzke, M., Kadner, I., Poetzsch, J., Groth, D., Radbruch, A., Hutloff, A., et al. (2020) · eLife · doi:10.7554/elife.53226 · Cited by 7
“Fluorescent intensities were transformed with inverse hyperbolic sine (arcsinh), which is a common transformation method for flow cytometry data (Finak et al., 2010).”
MethodAnalysis of Antigen‐Specific T and B Cells for Monitoring Immune Protection Against SARS‐CoV‐2
Biasi, S. D., Paolini, A., Tartaro, D. L., Gibellini, L., & Cossarizza, A. (2023) · Current Protocols · doi:10.1002/cpz1.636 · Cited by 8
Hejblum, B. P., Alkhassim, C., Gottardo, R., Caron, F., & Thiébaut, R. (2019) · The Annals of Applied Statistics · doi:10.1214/18-aoas1209 · Cited by 38
“Indeed, even after state-of-the-art transformation of raw cytometry data, such as the biexponential transformation (Finak et al., 2010), cell population distributions are typically skewed.”
InfluentialSelf-citationJeong, I. J., Hong, J., Bae, Y. J., & Lee, T. K. (2025) · Cytometry Part A · doi:10.1002/cyto.a.24923 · Cited by 6
Classifying Immunophenotypes With Templates From Flow Cytometry
Azad, A., Khan, A. A., Rajwa, B. P., Pyne, S., & Pothen, A. (2013) · ACM International Conference on Bioinformatics, Computational Biology, and Health Informatics (ACM-BCB) · doi:10.1145/2506583.2506627 · Cited by 6
Early chronic low-level lead exposure reduced C-C chemokine receptor 7 in hippocampal microglia
Flores‐Montoya, M. G., Bill, C. A., Vines, C. M., & Sobin, C. A. (2019) · Toxicology Letters · doi:10.1016/j.toxlet.2019.07.015 · Cited by 6
“GMFI was examined because flow cytometric data fallows a logarithmic (but not linear) distribution (Finak et al., 2010).”
BackgroundImmunophenotypes of Acute Myeloid Leukemia From Flow Cytometry Data Using TemplatesPreprint
Azad, A., Rajwa, B. P., & Pothen, A. (2014) · arXiv (Cornell University) · doi:10.48550/arxiv.1403.6358 · Cited by 6
“In addition to our work, templates have been used for detecting the effects of phosphorylation (Pyne et al., 2009), evaluating the efficiency of data transformations (Finak et al., 2010), and labeling clusters across samples (Spidlen et al., 2013).”
MethodBinet, L., Bremond, L., Duparc, M., Dong, C., David, L., Attaf, N., Gil, L., Fallet, M., Boudier, T., Escalière, B., et al. (2024) · bioRxiv (Cold Spring Harbor Laboratory) · doi:10.1101/2024.07.26.605240 · Cited by 5
Bayesian mixture models for cytometry data analysis
Lin, L., & Hejblum, B. P. (2020) · Wiley Interdisciplinary Reviews Computational Statistics · doi:10.1002/wics.1535 · Cited by 7
Coppard, V., Szép, G., Georgieva, Z. G., Howlett, S., Jarvis, L. B., Rainbow, D. B., Suchánek, O., Needham, E., Mousa, H. S., Menon, D. K., et al. (2024) · Frontiers in Immunology · doi:10.3389/fimmu.2024.1425488 · Cited by 6
Workflow for high-dimensional flow cytometry analysis of T cells from tumor metastases
Faccani, C., Rotta, G., Clemente, F., Fedeli, M., Abbati, D., Manfredi, F., Potenza, A., Anselmo, A., Pedica, F., Fiorentini, G., et al. (2022) · Life Science Alliance · doi:10.26508/lsa.202101316 · Cited by 5
“Second, to mitigate the complexity of the flow cytometry data distribution resulting from the variance of different fluorescence intensities (Finak et al, 2010), the cleaned data were transformed by arcSinh scaling.”
MethodHauchamps, P., Bayat, B., Delandre, S., Hamrouni, M., Toussaint, M., Temmerman, S. T., Dan, L., & Gatto, L. (2024) · BMC Bioinformatics · doi:10.1186/s12859-024-05691-z · Cited by 5
“All these steps are crucial to avoid that the subsequent analysis gets perturbed with erroneous signal (see e.g. [9] for compensation, [10] for scale transformation, [11] for signal stability in time, and [12] for other steps).”
BackgroundNet FCM : A semi‐automated web‐based method for flow cytometry data analysis
Frederiksen, J., Buggert, M., Karlsson, A. C., & Lund, O. (2014) · Cytometry Part A · doi:10.1002/cyto.a.22510 · Cited by 5
“Alternative transformations include the traditional logarithmic transformation that does not handle negative values well (32), Box-Cox (10), hyperbolic arcsine and Hyperlog (33) transformations.”
BackgroundMethodAI in flow cytometry: Current applications and future directions
Yue, A., Brinkman, R. R., Nash, V., Junker, F., Bogdanoski, G., Divekar, A., Tyznik, A. J., Špidlen, J., Kern, W., Pétriz, J., et al. (2025) · Cytometry Part B Clinical Cytometry · doi:10.1002/cyto.b.22255 · Cited by 7
“There are also several types of data transformations, in addition to methods that estimate transformation parameters (Finak et al., 2010).”
beadplexr: reproducible and automated analysis of multiplex bead assays
Stervbo, U., Westhoff, T. H., & Babel, N. (2018) · PeerJ · doi:10.7717/peerj.5794 · Cited by 4
“Apply an arcsinh transformation of the bead channels—this natural logarithm based transformation generally performs well on all flow cytometry data (Finak et al., 2010).”
MethodMulti-set Pre-processing of Multicolor Flow Cytometry Data
Folcarelli, R., Tinnevelt, G. H., Hilvering, B., Wouters, K., van Staveren, S., Postma, G., Vrisekoop, N., Buydens, L. M. C., Koenderman, L., & Jansen, J. J. (2020) · Scientific Reports · doi:10.1038/s41598-020-66195-3 · Cited by 4
Computational Analysis of High-Dimensional Flow Cytometric Data for Diagnosis and Discovery
Aghaeepour, N., & Brinkman, R. R. (2013) · Current topics in microbiology and immunology · doi:10.1007/82_2013_337 · Cited by 4
Learning Single‐Cell Distances from Cytometry Data
Nguyen, B., Rubbens, P., Kerckhof, F., Boon, N., Bernard De Baets, C., & Waegeman, W. (2019) · Cytometry Part A · doi:10.1002/cyto.a.23792 · Cited by 4
“Automated data analysis techniques include a number of preprocessing steps, such as specific transformations and quality controls of the data (5,6), often followed by dimensionality reduction and clustering techniques to visualize the data and to determine cell populations in an automated way (7–10).”
MethodAdo, S., Dong, C., Attaf, N., Moussa, M., Carrier, A., Milpied, P., & Navarro, J. (2024) · Frontiers in Immunology · doi:10.3389/fimmu.2024.1505971 · Cited by 5
“Plasmid DNA preparations were made from the screened positive bacterial fi ngerprints and each construct was sequenced and checked against the original sequences.”
Dutta, S., Box, A., Li, Y., & Sardiu, M. E. (2023) · PROTEOMICS · doi:10.1002/pmic.202200290 · Cited by 3
“Normalization is an essential step for cytometry data that eradicates the effects of technical artifacts and improves accuracy of downstream analysis [26–28].”
BackgroundLiu, M., Barton, E. S., Jennings, R. N., Oldenburg, D. G., Whirry, J. M., White, D. W., & Grayson, J. M. (2017) · Virology · doi:10.1016/j.virol.2017.06.018 · Cited by 3
Single Cell and Population Level Analysis of HCA Data
Novo, D., Ghosh, K., & Burke, S. (2017) · Methods in molecular biology · doi:10.1007/978-1-4939-7357-6_15 · Cited by 3
A high-throughput multiplex array for antigen-specific serology with automated analysisPreprint
Rosenberg, A. F., Killian, J. T., Green, T. J., Akther, J., Hossain, M. E., Shang, Q., Qiu, S., Guang, Y., Randall, T. D., Lund, F. E., et al. (2023) · bioRxiv (Cold Spring Harbor Laboratory) · doi:10.1101/2023.03.29.534777 · Cited by 3
Mass Cytometry Assessment of Cell Phenotypes and Signaling States in Human Whole Blood
Sigal, N., & Maecker, H. T. (2022) · Methods in molecular biology · doi:10.1007/978-1-0716-2553-8_10 · Cited by 3
McCoy, J. P. (2014) · Elsevier eBooks · doi:10.1016/b978-0-12-386456-7.07103-3 · Cited by 2
Kahng, J. A., Xavier, A. M., Ferro, A., Tang, S. X., Auguste, Y. S. S., & Cheadle, L. (2024) · Nature Protocols · doi:10.1038/s41596-024-01048-1 · Cited by 2
Navigating the data processing for cytometry-based single-cell proteomics
Sun, H., Zhou, Y., Jiang, R., Liu, Y., Gu, C., Pan, Z., Mou, M., Lian, X., Chen, B., Niu, T., et al. (2025) · Nature Protocols · doi:10.1038/s41596-025-01257-2 · Cited by 2
Machine Learning Designed for Any Hematologic Flow Cytometry Data Set
Mammen, J., Manta, C., Richter, S., Liebers, N., Roider, T., Czernilofsky, F., Kriegsmann, K., Müller‐Tidow, C., Hundemer, M., & Dietrich, S. (2025) · JCO Clinical Cancer Informatics · doi:10.1200/cci-24-00259 · Cited by 1
Bianchi, J., Vieira, A. I. S., Ligeiro, D., Azevedo, R. I., & de Lacerda, J. F. (2021) · ImmunoHorizons · doi:10.4049/immunohorizons.2100021 · Cited by 1
PRI: Re-Analysis of a Public Mass Cytometry Dataset Reveals Patterns of Effective Tumor Treatments
Hoang, Y. N. T., Gryzik, S., Hoppe, I., Rybak, A., Schädlich, M., Kadner, I., Walther, D., Vera, J., Radbruch, A., Groth, D., et al. (2022) · Frontiers in Immunology · doi:10.3389/fimmu.2022.849329 · Cited by 2
“The extracted CD4 + T cell populations are imported as FCS fi les in PRI, where the SI are transformed with inverse hyperbolic sine (arcsinh), commonly used for fl ow cytometric analysis (18), with a cofactor of 0.1.”
MethodInfluentialPopp, G., Jöckel, L., Kläs, M., Wiener, T. F., Hilger, N., Stumpf, N., Groß, J., Dünkel, A., Blache, U., Fricke, S., et al. (2025) · Cytometry Part A · doi:10.1002/cyto.a.24913 · Cited by 3
Grayson, J. M., Perez, M. D., Blevins, R., Coe, B. N., Detty, M. R., & McIver, Z. A. (2020) · PLoS ONE · doi:10.1371/journal.pone.0234778 · Cited by 1
“Samples were preprocessed to remove aggregates, labeled with animal and treatment, and subsequently, fluorescence channels were transformed by optimized Arcsinh and normalized by scaling [11].”
MethodGrégoire, C., Spinelli, L., Villazala‐Merino, S., Gil, L., Moussa, M., Dong, C., Zarubica, A., Fallet, M., Navarro, J., MALISSEN, B., et al. (2021) · bioRxiv (Cold Spring Harbor Laboratory) · doi:10.1101/2021.12.14.472614 · Cited by 1
“For visualization on linear scales in the R programming software, we applied the hyperbolic arcsine transformation on fluorescence parameters (Finak et al., 2010).”
MethodRothwell, A., Carter, A., Green, P., & Jones, A. R. (2022) · medRxiv · doi:10.1101/2022.12.07.22283209 · Cited by 1
“The Logicle transformation has been suggested as the preferred transformation for FC data, resulting in fewer misclassified events than other popular transformations [35].”
Mahnke, Y. D., & Rajwa, B. P. (2026) · Cytometry Part A · doi:10.1002/cyto.a.70023 · Cited by 1
Nolan, G. P. (2013) · Defense Technical Information Center (DTIC) · doi:10.21236/ada599601
Alternative Approaches for Analysis of Complex Data Sets in Flow Cytometry
Gondhalekar, C. (2017) · Series in bioengineering · doi:10.1007/978-981-10-4499-1_9 · Cited by 1
Cirovic, B., Katzmarski, N., & Schlitzer, A. (2019) · Methods in molecular biology · doi:10.1007/978-1-4939-9454-0_18
Machine learning for flow cytometry data analysis
Scott, C. D., & Lee, G. (2011) · Cited by 2
Flow cytometry: counting and sorting stained cells
Ortutay, C., & Ortutay, Z. (2017) · Wiley eBooks · doi:10.1002/9781119165057.ch13
Ortolani, C. (2022) · Springer eBooks · doi:10.1007/978-3-031-10836-5_12
Kahng, J. A., Xavier, A. M., Ferro, A., Auguste, Y. S. S., & Cheadle, L. (2023) · bioRxiv (Cold Spring Harbor Laboratory) · doi:10.1101/2023.08.24.554663
Rosa, S. C. D., & Mahnke, Y. D. (2024) · Cytometry Part A · doi:10.1002/cyto.a.24844
“The introduction of bi-exponential scaling [7, 8] may now seem trivial, just another tool that is universally used, but this “ tool ” does not simply provide a more aesthetically pleasing data representation.”
MethodHauchamps, P., Bayat, B., Delandre, S., Hamrouni, M., Toussaint, M., Temmerman, S. T., Dan, L., & Gatto, L. (2024) · Figshare · doi:10.6084/m9.figshare.25255763
Nandakumar, S., Farjood, F., Bertucci, T. B., Lotz, S., Sai, S., Wang, Y., Kozak, J. A., Arduini, B. L., Stern, J. H., Boles, N. C., et al. (2026) · bioRxiv (Cold Spring Harbor Laboratory) · doi:10.64898/2026.02.26.708319
Brisou, G. (2020) · theses.fr (ABES) · doi:10.70675/0b7366f2z1264z4d83z8f28z435932a47a1a
Flow Cytometry Data: Processing, Analysis, Artifacts, and Pitfalls
Wang, X. (2026) · Cambridge University Press eBooks · doi:10.1017/9781009397797.041
Guidelines for Gating Flow Cytometry Data for Immunological Assays
Staats, J., Divekar, A., McCoy, J. P., & Maecker, H. T. (2026) · Methods in molecular biology · doi:10.1007/978-1-0716-5607-5_14
Metadata
- Authors
- Finak, G., Perez, J.-M., Weng, A., & Gottardo, R.
- Affiliations
- Fred Hutch Cancer Center (US)
- Montreal Clinical Research Institute (CA)
- Terry Fox Research Institute (CA)
- Corresponding author
- Finak, Greg
- Venue
- BMC Bioinformatics
- Published
- 2010-11-04
- Volume
- 11
- Issue
- 1
- Pages
- 546-546
- ISSN
- 1471-2105 (ISSN-L)
- PMC
- PMC3243046
- OpenAlex
- W1976192231
- Cited by
- 99
- References
- 27
- Citations by year
- 2026: 4 · 2025: 5 · 2024: 9 · 2023: 6 · 2022: 7 · 2021: 7 · 2020: 12 · 2019: 14 · 2018: 8 · 2017: 6 · 2016: 2 · 2015: 5 · 2014: 4 · 2013: 4 · 2012: 4
- FWCI
- 1.93
- Type
- journal article
- Language
- en
- Open access
- gold
- doi.org
- Licence
- cc-by
- creativecommons.org/licenses/by/2.0 (tdm)
- Locations
- BMC Bioinformatics (publishedVersion, cc-by)
- Europe PMC (PubMed Central) (publishedVersion, cc-by)
- PubMed Central (publishedVersion, cc-by)
- PubMed (publishedVersion)
- DOAJ (DOAJ: Directory of Open Access Journals) (submittedVersion)
- Funders
- National Institutes of Health
- Canadian Institutes of Health Research
- National Institute of Biomedical Imaging and Bioengineering (R01EB008400)
- Topics
- Life Sciences › Biochemistry, Genetics and Molecular Biology › Biophysics › Cell Image Analysis Techniques
- Life Sciences › Biochemistry, Genetics and Molecular Biology › Molecular Biology › Single-cell and spatial transcriptomics
- Life Sciences › Biochemistry, Genetics and Molecular Biology › Molecular Biology › Gene expression and cancer classification
- Keywords
- automated gating, high-throughput flow cytometry, parameter optimization, maximum likelihood estimation, Bioconductor
- MeSH terms
- Algorithms, Cells, Data Interpretation, Statistical, Flow Cytometry, Databases, Factual
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.