Metabolomic database annotations via query of elemental compositions: Mass accuracy is insufficient even at less than 1 ppm
Open accessThe DOI matches its Crossref record; 24 of the 24 references it cites were found in a registry or an index.
Abstract
Background: Metabolomic studies are targeted at identifying and quantifying all metabolites in a given biological context. Among the tools used for metabolomic research, mass spectrometry is one of the most powerful tools. However, metabolomics by mass spectrometry always reveals a high number of unknown compounds which complicate in depth mechanistic or biochemical understanding. In principle, mass spectrometry can be utilized within strategies of de novo structure elucidation of small molecules, starting with the computation of the elemental composition of an unknown metabolite using accurate masses with errors <5 ppm (parts per million). However even with very high mass accuracy (<1 ppm) many chemically possible formulae are obtained in higher mass regions. In automatic routines an additional orthogonal filter therefore needs to be applied in order to reduce the number of potential elemental compositions. This report demonstrates the necessity of isotope abundance information by mathematical confirmation of the concept. Results: High mass accuracy (<1 ppm) alone is not enough to exclude enough candidates with complex elemental compositions (C, H, N, S, O, P, and potentially F, Cl, Br and Si). Use of isotopic abundance patterns as a single further constraint removes >95% of false candidates. This orthogonal filter can condense several thousand candidates down to only a small number of molecular formulas. Example calculations for 10, 5, 3, 1 and 0.1 ppm mass accuracy are given. Corresponding software scripts can be downloaded from http://fiehnlab.ucdavis.edu. A comparison of eight chemical databases revealed that PubChem and the Dictionary of Natural Products can be recommended for automatic queries using molecular formulae. Conclusion: More than 1.6 million molecular formulae in the range 0–500 Da were generated in an exhaustive manner under strict observation of mathematical and chemical rules. Assuming that ion species are fully resolved (either by chromatography or by high resolution mass spectrometry), we conclude that a mass spectrometer capable of 3 ppm mass accuracy and 2% error for isotopic abundance patterns outperforms mass spectrometers with less than 1 ppm mass accuracy or even hypothetical mass spectrometers with 0.1 ppm mass accuracy that do not include isotope information in the calculation of molecular formulae.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Atomic weights of the elements. Review 2000 (IUPAC Technical Report)
de Laeter, J. R., Böhlke, J. K., De Bièvre, P., Hidaka, H., Peiser, H. S., Rosman, K. J. R., & Taylor, P. D. P. (2003) · Pure and Applied Chemistry · doi:10.1351/pac200375060683 · Cited by 1,049
Combining genomics, metabolome analysis, and biochemical modelling to understand metabolic networks
Fiehn, O. (2001) · Comparative and Functional Genomics · doi:10.1002/cfg.82 · Cited by 934
Self-citationNicolaou, K. C., & Snyder, S. A. (2005) · Angewandte Chemie International Edition · doi:10.1002/anie.200460864 · Cited by 628
Weckwerth, W., Wenzel, K., & Fiehn, O. (2004) · PROTEOMICS · doi:10.1002/pmic.200200500 · Cited by 425
Self-citationDifferential metabolic networks unravel the effects of silent plant phenotypes
Weckwerth, W., Loureiro, M. E., Wenzel, K., & Fiehn, O. (2004) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.0303415101 · Cited by 400
Self-citationMilestones in fourier transform ion cyclotron resonance mass spectrometry technique development
Marshall, A. G. (2000) · International Journal of Mass Spectrometry · doi:10.1016/s1387-3806(00)00324-9 · Cited by 295
Modern isotope ratio mass spectrometry
Platzner, I. (1997) · Cited by 293
Wagner, C., Sefkow, M., & Kopka, J. (2003) · Phytochemistry · doi:10.1016/s0031-9422(02)00703-3 · Cited by 291
A general approach to calculating isotopic distributions for mass spectrometry
Yergey, J. A. (1983) · International Journal of Mass Spectrometry and Ion Physics · doi:10.1016/0020-7381(83)85053-0 · Cited by 222
Comparison of the NCI Open Database with Seven Large Chemical Structural Databases
Voigt, J. H., Bienfait, B., Wang, S., & Nicklaus, M. C. (2001) · Journal of Chemical Information and Computer Sciences · doi:10.1021/ci000150t · Cited by 216
Intercomparison study on accurate mass measurement of small molecules in mass spectrometry
Bristow, A. W. T., & Webb, K. S. (2003) · Journal of the American Society for Mass Spectrometry · doi:10.1016/s1044-0305(03)00403-3 · Cited by 139
Accuracy Requirements for Peptide Characterization by Monoisotopic Molecular Mass Measurements
Zubarev, R. A., Håkansson, P., & Sundqvist, B. (1996) · Analytical Chemistry · doi:10.1021/ac9604651 · Cited by 126
Ultrahigh-Speed Calculation of Isotope Distributions
Rockwood, A. L., & Van Orden, S. L. (1996) · Analytical Chemistry · doi:10.1021/ac951158i · Cited by 122
Atomic Weights of the Elements: Review 2000
Laeter, J. R. D., Böhlke, J. K., Bièvre, P. D., Hidaka, H., Peiser, H. S., Rosman, K. J. R., & Taylor, P. (2016) · IUPAC Standards Online · doi:10.1515/iupac.75.0022 · Cited by 102
Recent developments in automated structure elucidation of natural products
Steinbeck, C. (2004) · Natural Product Reports · doi:10.1039/b400678j · Cited by 99
Partitions and Their Representative Graphs
SENIOR, J. K. (1951) · American Journal of Mathematics · doi:10.2307/2372318 · Cited by 94
Faulon, J. (1994) · Journal of Chemical Information and Computer Sciences · doi:10.1021/ci00021a031 · Cited by 91
Fredenhagen, A., Derrien, C., & Gassmann, E. (2005) · Journal of Natural Products · doi:10.1021/np049657e · Cited by 89
Wu, Q. (1998) · Analytical Chemistry · doi:10.1021/ac971132m · Cited by 30
Grange, A. H., Genicola, F. A., & Sovocool, G. W. (2002) · Rapid Communications in Mass Spectrometry · doi:10.1002/rcm.842 · Cited by 30
Debating Resolution and Mass Accuracy
Balogh, M. P. (2004) · Cited by 25
Seebass, B., & Pretsch, E. (1999) · Journal of Chemical Information and Computer Sciences · doi:10.1021/ci980171b · Cited by 10
Simple tools for the computer-aided interpretation of mass spectra
Heuerding, S., & Clerc, J. T. (1993) · Chemometrics and Intelligent Laboratory Systems · doi:10.1016/0169-7439(93)80021-9 · Cited by 9
ANALOGOUS ODD-EVEN PARITIES IN MATHEMATICS AND CHEMISTRY
Morikawa, T., & Newbold, B. T. (2003) · Cited by 9
Cited by
MetaboAnalyst 4.0: towards more transparent and integrative metabolomics analysis
Chong, J., Soufan, O., Li, C., Caraus, I., Li, S., Bourque, G., Wishart, D. S., & Xia, J. (2018) · Nucleic Acids Research · doi:10.1093/nar/gky310 · Cited by 3,629
INTERPRETATION OF MASS SPECTRA
(1991) · Analytical Chemistry · doi:10.1021/ac00022a726 · Cited by 1,840
Untargeted Metabolomics Strategies—Challenges and Emerging Directions
Schrimpe-Rutledge, A. C., Codreanu, S. G., Sherrod, S. D., & McLean, J. A. (2016) · Journal of the American Society for Mass Spectrometry · doi:10.1007/s13361-016-1469-y · Cited by 1,372
Evans, A. M., DeHaven, C. D., Barrett, T., Mitchell, M., & Milgram, E. (2009) · Analytical Chemistry · doi:10.1021/ac901536h · Cited by 1,333
Kind, T., & Fiehn, O. (2007) · BMC Bioinformatics · doi:10.1186/1471-2105-8-105 · Cited by 1,201
“However, data acquired even by ultrahigh mass accuracy and mass resolution are insufficient for calculating unique elemental compositions without information about isotope ratios [10].”
BackgroundMethodInfluentialSelf-citation
Metadata
- Authors
- Kind, T., & Fiehn, O.
- Venue
- BMC Bioinformatics
- Published
- 2006-04-28
- Volume
- 7
- Issue
- 1
- Pages
- 234-234
- ISSN
- 1471-2105 (ISSN-L)
- OpenAlex
- W1480161928
- Cited by
- 637
- References
- 24
- FWCI
- 10.56
- Type
- journal article
- Language
- en
- Open access
- gold
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.