Metabolomic database annotations via query of elemental compositions: Mass accuracy is insufficient even at less than 1 ppm
Open accessThe DOI matches its Crossref record; 24 of the 24 references it cites were found in a registry or an index.
Abstract
Background: Metabolomic studies are targeted at identifying and quantifying all metabolites in a given biological context. Among the tools used for metabolomic research, mass spectrometry is one of the most powerful tools. However, metabolomics by mass spectrometry always reveals a high number of unknown compounds which complicate in depth mechanistic or biochemical understanding. In principle, mass spectrometry can be utilized within strategies of de novo structure elucidation of small molecules, starting with the computation of the elemental composition of an unknown metabolite using accurate masses with errors <5 ppm (parts per million). However even with very high mass accuracy (<1 ppm) many chemically possible formulae are obtained in higher mass regions. In automatic routines an additional orthogonal filter therefore needs to be applied in order to reduce the number of potential elemental compositions. This report demonstrates the necessity of isotope abundance information by mathematical confirmation of the concept. Results: High mass accuracy (<1 ppm) alone is not enough to exclude enough candidates with complex elemental compositions (C, H, N, S, O, P, and potentially F, Cl, Br and Si). Use of isotopic abundance patterns as a single further constraint removes >95% of false candidates. This orthogonal filter can condense several thousand candidates down to only a small number of molecular formulas. Example calculations for 10, 5, 3, 1 and 0.1 ppm mass accuracy are given. Corresponding software scripts can be downloaded from http://fiehnlab.ucdavis.edu. A comparison of eight chemical databases revealed that PubChem and the Dictionary of Natural Products can be recommended for automatic queries using molecular formulae. Conclusion: More than 1.6 million molecular formulae in the range 0–500 Da were generated in an exhaustive manner under strict observation of mathematical and chemical rules. Assuming that ion species are fully resolved (either by chromatography or by high resolution mass spectrometry), we conclude that a mass spectrometer capable of 3 ppm mass accuracy and 2% error for isotopic abundance patterns outperforms mass spectrometers with less than 1 ppm mass accuracy or even hypothetical mass spectrometers with 0.1 ppm mass accuracy that do not include isotope information in the calculation of molecular formulae.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Atomic weights of the elements. Review 2000 (IUPAC Technical Report)
de Laeter, J. R., Böhlke, J. K., De Bièvre, P., Hidaka, H., Peiser, H. S., Rosman, K. J. R., & Taylor, P. D. P. (2003) · Pure and Applied Chemistry · doi:10.1351/pac200375060683 · Cited by 1,049
Combining genomics, metabolome analysis, and biochemical modelling to understand metabolic networks
Fiehn, O. (2001) · Comparative and Functional Genomics · doi:10.1002/cfg.82 · Cited by 934
Self-citationNicolaou, K. C., & Snyder, S. A. (2005) · Angewandte Chemie International Edition · doi:10.1002/anie.200460864 · Cited by 628
Weckwerth, W., Wenzel, K., & Fiehn, O. (2004) · PROTEOMICS · doi:10.1002/pmic.200200500 · Cited by 425
Self-citationDifferential metabolic networks unravel the effects of silent plant phenotypes
Weckwerth, W., Loureiro, M. E., Wenzel, K., & Fiehn, O. (2004) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.0303415101 · Cited by 400
Self-citationMilestones in fourier transform ion cyclotron resonance mass spectrometry technique development
Marshall, A. G. (2000) · International Journal of Mass Spectrometry · doi:10.1016/s1387-3806(00)00324-9 · Cited by 295
Modern isotope ratio mass spectrometry
Platzner, I. (1997) · Cited by 293
Wagner, C., Sefkow, M., & Kopka, J. (2003) · Phytochemistry · doi:10.1016/s0031-9422(02)00703-3 · Cited by 291
A general approach to calculating isotopic distributions for mass spectrometry
Yergey, J. A. (1983) · International Journal of Mass Spectrometry and Ion Physics · doi:10.1016/0020-7381(83)85053-0 · Cited by 222
Comparison of the NCI Open Database with Seven Large Chemical Structural Databases
Voigt, J. H., Bienfait, B., Wang, S., & Nicklaus, M. C. (2001) · Journal of Chemical Information and Computer Sciences · doi:10.1021/ci000150t · Cited by 216
Cited by
MetaboAnalyst 4.0: towards more transparent and integrative metabolomics analysis
Chong, J., Soufan, O., Li, C., Caraus, I., Li, S., Bourque, G., Wishart, D. S., & Xia, J. (2018) · Nucleic Acids Research · doi:10.1093/nar/gky310 · Cited by 3,629
INTERPRETATION OF MASS SPECTRA
(1991) · Analytical Chemistry · doi:10.1021/ac00022a726 · Cited by 1,840
Untargeted Metabolomics Strategies—Challenges and Emerging Directions
Schrimpe-Rutledge, A. C., Codreanu, S. G., Sherrod, S. D., & McLean, J. A. (2016) · Journal of the American Society for Mass Spectrometry · doi:10.1007/s13361-016-1469-y · Cited by 1,372
Evans, A. M., DeHaven, C. D., Barrett, T., Mitchell, M., & Milgram, E. (2009) · Analytical Chemistry · doi:10.1021/ac901536h · Cited by 1,333
Kind, T., & Fiehn, O. (2007) · BMC Bioinformatics · doi:10.1186/1471-2105-8-105 · Cited by 1,201
“However, data acquired even by ultrahigh mass accuracy and mass resolution are insufficient for calculating unique elemental compositions without information about isotope ratios [10].”
BackgroundMethodInfluentialSelf-citationSugimoto, M., Wong, D. T., Hirayama, A., Soga, T., & Tomita, M. (2010) · Metabolomics · doi:10.1007/s11306-009-0178-y · Cited by 993
Predicting Network Activity from High Throughput Metabolomics
Li, S., Park, Y., Duraisingham, S., Strobel, F. H., Khan, N., Soltow, Q. A., Jones, D. P., & Pulendran, B. (2013) · PLoS Computational Biology · doi:10.1371/journal.pcbi.1003123 · Cited by 936
Metabolomics for Functional Genomics, Systems Biology, and Biotechnology
Saito, K., & Matsuda, F. (2010) · Annual Review of Plant Biology · doi:10.1146/annurev.arplant.043008.092035 · Cited by 744
Krauss, M., Singer, H., & Hollender, J. (2010) · Analytical and Bioanalytical Chemistry · doi:10.1007/s00216-010-3608-9 · Cited by 743
Comprehensive analysis of lipids in biological systems by liquid chromatography-mass spectrometry
Cajka, T., & Fiehn, O. (2014) · TrAC Trends in Analytical Chemistry · doi:10.1016/j.trac.2014.04.017 · Cited by 650
Self-citationZhou, B., Xiao, J. F., Tuli, L., & Ressom, H. W. (2011) · Molecular BioSystems · doi:10.1039/c1mb05350g · Cited by 639
Current approaches and challenges for the metabolite profiling of complex natural extracts
Wolfender, J.-L., Marti, G., Thomas, A., & Bertrand, S. (2015) · Journal of Chromatography A · doi:10.1016/j.chroma.2014.10.091 · Cited by 635
Metabolite identification and quantitation in LC-MS/MS-based metabolomics
Xiao, J. F., Zhou, B., & Ressom, H. W. (2012) · TrAC Trends in Analytical Chemistry · doi:10.1016/j.trac.2011.08.009 · Cited by 620
Mass appeal: metabolite identification in mass spectrometry-focused untargeted metabolomics
Dunn, W. B., Erban, A., Weber, R. J. M., Creek, D. J., Brown, M., Breitling, R., Hankemeier, T., Goodacre, R., Neumann, S., Kopka, J., et al. (2013) · Metabolomics · doi:10.1007/s11306-012-0434-4 · Cited by 555
Liquid chromatography–mass spectrometry based global metabolite profiling: A review
Theodoridis, G. A., Gika, H. G., Want, E. J., & Wilson, I. D. (2012) · Analytica Chimica Acta · doi:10.1016/j.aca.2011.09.042 · Cited by 518
FDR-controlled metabolite annotation for high-resolution imaging mass spectrometry
Palmer, A., Phapale, P., Chernyavsky, I., Lavigne, R., Fay, D., Tarasov, A., Kovalev, V., Fuchser, J., Nikolenko, S., Pineau, C., et al. (2017) · Nature Methods · doi:10.1038/nmeth.4072 · Cited by 509
Bertrand, S., Bohni, N., Schnee, S., Schumpp, O., Gindro, K., & Wolfender, J.-L. (2014) · Biotechnology Advances · doi:10.1016/j.biotechadv.2014.03.001 · Cited by 487
Advances in structure elucidation of small molecules using mass spectrometry
Kind, T., & Fiehn, O. (2010) · Bioanalytical Reviews · doi:10.1007/s12566-010-0015-9 · Cited by 480
Self-citationA comprehensive urinary metabolomic approach for identifying kidney cancer
Kind, T., Tolstikov, V., Fiehn, O., & Weiss, R. H. (2007) · Analytical Biochemistry · doi:10.1016/j.ab.2007.01.028 · Cited by 449
Self-citationCurrent practice of liquid chromatography–mass spectrometry in metabolomics and metabonomics
Gika, H. G., Theodoridis, G. A., Plumb, R. S., & Wilson, I. D. (2014) · Journal of Pharmaceutical and Biomedical Analysis · doi:10.1016/j.jpba.2013.06.032 · Cited by 442
Allard, P.-M., Péresse, T., Bisson, J., Gindro, K., Marcourt, L., Pham, V. C., Roussi, F., Litaudon, M., & Wolfender, J.-L. (2016) · Analytical Chemistry · doi:10.1021/acs.analchem.5b04804 · Cited by 431
Challenges and emergent solutions for LC‐MS/MS based untargeted metabolomics in diseases
Cui, L., Lu, H., & Lee, Y. H. (2018) · Mass Spectrometry Reviews · doi:10.1002/mas.21562 · Cited by 415
Schymanski, E. L., Singer, H. P., Longrée, P., Loos, M., Ruff, M., Stravs, M. A., Ripollés Vidal, C., & Hollender, J. (2014) · Environmental Science & Technology · doi:10.1021/es4044374 · Cited by 414
Metabolic Fingerprinting As A Diagnostic Tool
Ellis, D. I., Dunn, W. B., Griffin, J. L., Allwood, J. W., & Goodacre, R. (2007) · Pharmacogenomics · doi:10.2217/14622416.8.9.1243 · Cited by 396
High-Resolution Mass Spectrometers
Marshall, A. G., & Hendrickson, C. L. (2008) · Annual Review of Analytical Chemistry · doi:10.1146/annurev.anchem.1.031207.112945 · Cited by 394
Metabolomics technologies and metabolite identification
Moco, S., Vervoort, J., Moco, S., Bino, R. J., De Vos, R. C. H., & Bino, R. (2007) · TrAC Trends in Analytical Chemistry · doi:10.1016/j.trac.2007.08.003 · Cited by 390
Uppal, K., Soltow, Q. A., Strobel, F. H., Pittard, W. S., Gernert, K. M., Yu, T., & Jones, D. P. (2013) · BMC Bioinformatics · doi:10.1186/1471-2105-14-15 · Cited by 372
Challenges, progress and promises of metabolite annotation for LC–MS-based metabolomics
Chaleckis, R., Meister, I., Zhang, P., & Wheelock, C. E. (2019) · Current Opinion in Biotechnology · doi:10.1016/j.copbio.2018.07.010 · Cited by 368
Topic modeling for untargeted substructure exploration in metabolomics
van der Hooft, J. J. J., Wandy, J., Barrett, M. P., Burgess, K. E. V., & Rogers, S. (2016) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.1608041113 · Cited by 365
Metabolic reaction network-based recursive metabolite annotation for untargeted metabolomics
Shen, X., Wang, R., Xiong, X., Yin, Y., Cai, Y., Ma, Z., Liu, N., & Zhu, Z.-J. (2019) · Nature Communications · doi:10.1038/s41467-019-09550-x · Cited by 364
Kuehnbaum, N. L., & Britz-McKibbin, P. (2013) · Chemical Reviews · doi:10.1021/cr300484s · Cited by 354
SIRIUS: decomposing isotope patterns for metabolite identification
Böcker, S., Letzel, M. C., Lipták, Z., & Pervukhin, A. (2009) · Bioinformatics · doi:10.1093/bioinformatics/btn603 · Cited by 354
Giavalisco, P., Li, Y., Matthes, A., Eckhardt, A., Hubberten, H., Hesse, H., Segu, S., Hummel, J., Köhl, K., & Willmitzer, L. (2011) · The Plant Journal · doi:10.1111/j.1365-313x.2011.04682.x · Cited by 345
Method validation strategies involved in non-targeted metabolomics
Naz, S., Vallejo, M., García, A., & Barbas, C. (2014) · Journal of Chromatography A · doi:10.1016/j.chroma.2014.04.071 · Cited by 332
bioinformatics tools for mass spectroscopy-based metabolomic data processing and analysis
Sugimoto, M., Kawakami, M., Robert, M., Soga, T., & Tomita, M. (2012) · Current Bioinformatics · doi:10.2174/157489312799304431 · Cited by 307
“A theoretical study estimated that the mass spectral information available from mass spectrometers with accuracy approaching 1 ppm, such as TOFMS, is not sufficient to identify peaks without a matched standard compound, as multiple candidate compounds are often retrieved from the large public databases [93].”
BackgroundWolfender, J.-L., Nuzillard, J.-M., van der Hooft, J. J. J., Renault, J.-H., & Bertrand, S. (2019) · Analytical Chemistry · doi:10.1021/acs.analchem.8b05112 · Cited by 305
xMSannotator: An R Package for Network-Based Annotation of High-Resolution Metabolomics Data
Uppal, K., Walker, D. I., & Jones, D. P. (2017) · Analytical Chemistry · doi:10.1021/acs.analchem.6b01214 · Cited by 297
Vogeser, M., & Seger, C. (2010) · Clinical Chemistry · doi:10.1373/clinchem.2009.138602 · Cited by 290
Metabolite annotations based on the integration of mass spectral information
Iijima, Y., Nakamura, Y., Ogata, Y., Tanaka, K., Sakurai, N., Suda, K., Suzuki, T., Suzuki, H., Okazaki, K., Kitayama, M., et al. (2008) · The Plant Journal · doi:10.1111/j.1365-313x.2008.03434.x · Cited by 283
“Thus the limited capability for metabolite identification has been one of the major obstacles in metabolomics (Kind and Fiehn, 2006; Wagner et al., 2003).”
BackgroundDunn, W. B. (2008) · Physical Biology · doi:10.1088/1478-3975/5/1/011001 · Cited by 278
Brown, M., Dunn, W. B., Dobson, P., Patel, Y., Winder, C. L., Francis-McIntyre, S., Begley, P., Carroll, K., Broadhurst, D., Tseng, A., et al. (2009) · The Analyst · doi:10.1039/b901179j · Cited by 269
Tolić, N., Liu, Y., Liyu, A., Shen, Y., Tfaily, M. M., Kujawinski, E. B., Longnecker, K., Kuo, L.-J., Robinson, E. W., Paša-Tolić, L., et al. (2017) · Analytical Chemistry · doi:10.1021/acs.analchem.7b03318 · Cited by 261
Styczynski, M. P., Moxley, J. F., Tong, L. V., Walther, J. L., Jensen, K. L., & Stephanopoulos, G. N. (2007) · Analytical Chemistry · doi:10.1021/ac0614846 · Cited by 245
Computational Metabolomics: A Framework for the Million Metabolome
Uppal, K., Walker, D. I., Liu, K., Li, S., Go, Y.-M., & Jones, D. P. (2016) · Chemical Research in Toxicology · doi:10.1021/acs.chemrestox.6b00179 · Cited by 244
“37,54 Internal standards and annotated features based on reference metabolites can be used for tracking mass accuracy and estimating mass measurement error.”
Pourchet, M., Debrauwer, L., Klanova, J., Price, E. J., Covaci, A., Caballero-Casero, N., Oberacher, H., Lamoree, M., Damont, A., Fenaille, F., et al. (2020) · Environment International · doi:10.1016/j.envint.2020.105545 · Cited by 244
Current developments in LC-MS for pharmaceutical analysis
Beccaria, M., & Cabooter, D. (2020) · The Analyst · doi:10.1039/c9an02145k · Cited by 241
Böttcher, C., Westphal, L., Schmotz, C., Prade, E., Scheel, D., & Glawischnig, E. (2009) · The Plant Cell · doi:10.1105/tpc.109.066670 · Cited by 230
“…elemental compositionswere calculated, filtered by isotope abundance and the number of double bond equivalents and electron parity (Kind and Fiehn, 2006), and checked for consistency in relation to elemental compositions calculated for fragment ions and observed neutral losses (Konishi et…”
MethodDe Vijlder, T., Valkenborg, D., Lemière, F., Romijn, E. P., Laukens, K., & Cuyckens, F. (2018) · Mass Spectrometry Reviews · doi:10.1002/mas.21551 · Cited by 229
“Even with a goodmass accuracy of <1 ppm, the accurate mass alone is often not sufficient to determine the elemental composition of an unknown.(36) The lower the mass the ions of interest are, the more”
BackgroundCurrent and emerging mass-spectrometry technologies for metabolomics
Bedair, M., & Sumner, L. W. (2008) · TrAC Trends in Analytical Chemistry · doi:10.1016/j.trac.2008.01.006 · Cited by 225
Fourier Transform Mass Spectrometry
Scigelova, M., Hornshaw, M., Giannakopulos, A., & Makarov, A. (2011) · Molecular & Cellular Proteomics · doi:10.1074/mcp.m111.009431 · Cited by 224
A Novel 9.4 Tesla FTICR Mass Spectrometer with Improved Sensitivity, Mass Resolution, and Mass Range
Kaiser, N. K., Quinn, J. P., Blakney, G. T., Hendrickson, C. L., & Marshall, A. G. (2011) · Journal of the American Society for Mass Spectrometry · doi:10.1007/s13361-011-0141-9 · Cited by 223
“Longer time-domain transient lifetime is needed for greater resolving power, to resolve isobaric species and to assign elemental composition at high m/z [15, 16].”
BackgroundWerner, E., Heilier, J.-F., Ducruix, C., Ezan, E., Junot, C., & Tabet, J.-C. (2008) · Journal of Chromatography B · doi:10.1016/j.jchromb.2008.07.004 · Cited by 211
Ojanperä, I., Kolmonen, M., & Pelander, A. (2012) · Analytical and Bioanalytical Chemistry · doi:10.1007/s00216-012-5726-z · Cited by 209
MassTRIX: mass translator into pathways
Suhre, K., & Schmitt-Kopplin, P. (2008) · Nucleic Acids Research · doi:10.1093/nar/gkn194 · Cited by 203
“…that a mass precision as high as 1 p.p.m. may not always suffice for an unambiguous annotation of all mass peaks considering all possible elements (14), but may be sufficient with materials of known elementary composition (15) or in the context of restricted metabolite possibilities of a given…”
BackgroundLiquid chromatography-mass spectrometry for the determination of chemical contaminants in food
Hird, S. J., Lau, B. P.-Y., Schuhmacher, R., & Krska, R. (2014) · TrAC Trends in Analytical Chemistry · doi:10.1016/j.trac.2014.04.005 · Cited by 203
“Data acquired even with <1 ppmmass accuracy and high mass-resolving power can still be insufficient for calculating unique elemental compositions without information about isotope pattern [134,135].”
BackgroundMetExplore: a web server to link metabolomic experiments and genome-scale metabolic networks
Cottret, L., Wildridge, D., Vinson, F., Barrett, M. P., Charles, H., Sagot, M.-F., & Jourdan, F. (2010) · Nucleic Acids Research · doi:10.1093/nar/gkq312 · Cited by 199
“The identification of metabolites by their masses is not always satisfactory since, even with high resolution mass spectrometry, the identification may be ambiguous (22), particularly with respect to isomers that by definition are of identical mass.”
BackgroundHigh-Performance Mass Spectrometry: Fourier Transform Ion Cyclotron Resonance at 14.5 Tesla
Schaub, T. M., Hendrickson, C. L., Horning, S., Quinn, J. P., Senko, M. W., & Marshall, A. G. (2008) · Analytical Chemistry · doi:10.1021/ac800386h · Cited by 192
High resolution mass spectrometry based techniques at the crossroads of metabolic pathways
Junot, C., Fenaille, F., Colsch, B., & Bécher, F. (2014) · Mass Spectrometry Reviews · doi:10.1002/mas.21401 · Cited by 177
“Moreover, it has been shown that a mass spectrometer capable of 3 ppm mass accuracy and 2% error for isotopic abundance patterns should outperform mass spectrometers providing a mass accuracy of 0.1 ppm and poor performances in terms of RIA measurement (Kind & Fiehn, 2006).”
BackgroundInfluentialComputational mass spectrometry for metabolomics: Identification of metabolites and small molecules
Neumann, S., & Böcker, S. (2010) · Analytical and Bioanalytical Chemistry · doi:10.1007/s00216-010-4142-5 · Cited by 175
“In their theoretical evaluation, Kind and Fiehn [12] showed that an instrument with 3-ppm mass accuracy and 2% RIA (relative isotope abundance) accuracy allows one to calculate a single sum formula up to 300 Da.”
BackgroundAlgorithms and tools for the preprocessing of LC–MS metabolomics data
Castillo, S., Gopalacharyulu, P., Yetukuri, L., & Orešič, M. (2011) · Chemometrics and Intelligent Laboratory Systems · doi:10.1016/j.chemolab.2011.03.010 · Cited by 175
Computational mass spectrometry for small molecules
Scheubert, K., Hufsky, F., & Böcker, S. (2013) · Journal of Cheminformatics · doi:10.1186/1758-2946-5-12 · Cited by 173
“Decomposing alone is not sufficient to exclude enough possible molecular formulas in higher mass regions even with very high mass accuracy [117].”
BackgroundMethodInfluentialKueger, S., Steinhauser, D., Willmitzer, L., & Giavalisco, P. (2012) · The Plant Journal · doi:10.1111/j.1365-313x.2012.04902.x · Cited by 171
ICBM-OCEAN: Processing Ultrahigh-Resolution Mass Spectrometry Data of Complex Molecular Mixtures
Merder, J., Freund, J. A., Feudel, U., Hansen, C. T., Hawkes, J. A., Jacob, B., Klaproth, K., Niggemann, J., Noriega-Ortega, B. E., Osterholz, H., et al. (2020) · Analytical Chemistry · doi:10.1021/acs.analchem.9b05659 · Cited by 171
Draper, J., Enot, D. P., Parker, D., Beckmann, M., Snowdon, S., Lin, W., & Zubair, H. (2009) · BMC Bioinformatics · doi:10.1186/1471-2105-10-227 · Cited by 169
“With the advent of ultra-high accuracy mass analyzers such as the Orbitrap (resolution ~100,000) and Fourier Transform Ion Cyclotron Resonance (FT-ICR) analyzer (resolution potentially in excess of 1,000,000) this latter problem is greatly reduced [ 17-19 ].”
BackgroundMethodInfluentialAnnotation: A Computational Solution for Streamlining Metabolomics Analysis
Domingo-Almenara, X., Montenegro-Burke, J. R., Benton, H. P., & Siuzdak, G. (2018) · Analytical Chemistry · doi:10.1021/acs.analchem.7b03929 · Cited by 167
Southam, A. D., Weber, R. J. M., Engel, J., Jones, M. R., & Viant, M. R. (2017) · Nature Protocols · doi:10.1038/nprot.2016.156 · Cited by 162
Stark, H., Yatavelli, R. L. N., Thompson, S. L., Kimmel, J. R., Cubison, M. J., Chhabra, P. S., Canagaratna, M. R., Jayne, J. T., Worsnop, D. R., & Jimenez, J. L. (2015) · International Journal of Mass Spectrometry · doi:10.1016/j.ijms.2015.08.011 · Cited by 161
Böttcher, C., von Roepenack-Lahaye, E., Schmidt, J., Schmotz, C., Neumann, S., Scheel, D., & Clemens, S. (2008) · Plant Physiology · doi:10.1104/pp.108.117754 · Cited by 159
“Although isotope abundance information can be used as an orthogonal filter to efficiently reduce the number of potential elemental compositions (Kind and Fiehn, 2006), isotope abundances obtained with the hardware and hardware settings used in this study were of low accuracy and therefore hardly…”
BackgroundWeb-based resources for mass-spectrometry-based metabolomics: a user’s guide
Tohge, T., & Fernie, A. R. (2009) · Phytochemistry · doi:10.1016/j.phytochem.2009.02.004 · Cited by 152
Draper, J., Lloyd, A. J., Goodacre, R., & Beckmann, M. (2013) · Metabolomics · doi:10.1007/s11306-012-0449-x · Cited by 144
García-Villalba, R., León, C., Dinelli, G., Segura-Carretero, A., Fernández-Gutiérrez, A., Garcia-Cañas, V., & Cifuentes, A. (2008) · Journal of Chromatography A · doi:10.1016/j.chroma.2008.05.018 · Cited by 129
Metadata
- Authors
- Kind, T., & Fiehn, O.
- Venue
- BMC Bioinformatics
- Published
- 2006-04-28
- Volume
- 7
- Issue
- 1
- Pages
- 234-234
- ISSN
- 1471-2105 (ISSN-L)
- OpenAlex
- W1480161928
- Cited by
- 637
- References
- 24
- FWCI
- 10.56
- Type
- journal article
- Language
- en
- Open access
- gold
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.