A new real-time PCR method to overcome significant quantitative inaccuracy due to slight amplification inhibition
Open accessThe DOI matches its Crossref record; 37 of the 37 references it cites were found in a registry or an index.
Abstract
BACKGROUND: Real-time PCR analysis is a sensitive DNA quantification technique that has recently gained considerable attention in biotechnology, microbiology and molecular diagnostics. Although, the cycle-threshold (Ct) method is the present "gold standard", it is far from being a standard assay. Uniform reaction efficiency among samples is the most important assumption of this method. Nevertheless, some authors have reported that it may not be correct and a slight PCR efficiency decrease of about 4% could result in an error of up to 400% using the Ct method. This reaction efficiency decrease may be caused by inhibiting agents used during nucleic acid extraction or copurified from the biological sample. We propose a new method (Cy0) that does not require the assumption of equal reaction efficiency between unknowns and standard curve. RESULTS: The Cy0 method is based on the fit of Richards' equation to real-time PCR data by nonlinear regression in order to obtain the best fit estimators of reaction parameters. Subsequently, these parameters were used to calculate the Cy0 value that minimizes the dependence of its value on PCR kinetic. The Ct, second derivative (Cp), sigmoidal curve fitting method (SCF) and Cy0 methods were compared using two criteria: precision and accuracy. Our results demonstrated that, in optimal amplification conditions, these four methods are equally precise and accurate. However, when PCR efficiency was slightly decreased, diluting amplification mix quantity or adding a biological inhibitor such as IgG, the SCF, Ct and Cp methods were markedly impaired while the Cy0 method gave significantly more accurate and precise results. CONCLUSION: Our results demonstrate that Cy0 represents a significant improvement over the standard methods for obtaining a reliable and precise nucleic acid quantification even in sub-optimal amplification conditions overcoming the underestimation caused by the presence of some PCR inhibitors.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
A Flexible Growth Function for Empirical Use
RICHARDS, F. J. (1959) · Journal of Experimental Botany · doi:10.1093/jxb/10.2.290 · Cited by 4,146 · cited 1×
“The Cy0 method was performed by nonlinear regression fitting of the Richards function [25], an extension of logistic growth curve, in order to fit fluorescence readings to the 5-parameter Richards function: F F”
MethodBustin, S. (2000) · Journal of Molecular Endocrinology · doi:10.1677/jme.0.0250169 · Cited by 3,872
Assumption-free analysis of quantitative real-time polymerase chain reaction (PCR) data
Ramakers, C., Ruijter, J. M., Deprez, R. H. L., & Moorman, A. F. M. (2003) · Neuroscience Letters · doi:10.1016/s0304-3940(02)01423-4 · Cited by 3,709 · cited 3×
“However, most current methods of PCR efficiency assessment report "overall" efficiency as a single value [13, 24 ,36,37].”
MethodInfluentialQuantification of mRNA using real-time RT-PCR
Nolan, T., Hands, R. E., & Bustin, S. A. (2006) · Nature Protocols · doi:10.1038/nprot.2006.236 · Cited by 2,247 · cited 1×
“With a large dynamic range (7–8 magnitudes) and a high degree of sensitivity (5–10 molecules), the real-time PCR addresses the evident requirement for quantitative data analysis in molecular medicine, biotechnology, microbiology and diagnostics [5,6].”
BackgroundKinetic PCR Analysis: Real-time Monitoring of DNA Amplification Reactions
Higuchi, R., Fockler, C., Dollinger, G., & Watson, R. (1993) · Nature Biotechnology · doi:10.1038/nbt0993-1026 · Cited by 2,159 · cited 1×
“Background In the last few years, the real-time polymerase chain reaction (PCR) has rapidly become the most widely used technique in modern molecular biology [1-4].”
MethodLivak, K. J., Flood, S. J., Marmaro, J., Giusti, W., & Deetz, K. (1995) · Genome Research · doi:10.1101/gr.4.6.357 · Cited by 1,603
Comprehensive Algorithm for Quantitative Real-Time Polymerase Chain Reaction
Zhao, S., & Fernald, R. D. (2005) · Journal of Computational Biology · doi:10.1089/cmb.2005.12.1047 · Cited by 1,303 · cited 1×
“The main complication is that actual efficiency amplification is not constant through the PCR run being high in exponential phase and gradually declining towards the plateau phase [33-35].”
BackgroundPeirson, S. N. (2003) · Nucleic Acids Research · doi:10.1093/nar/gng073 · Cited by 843 · cited 1×
“However, most current methods of PCR efficiency assessment report "overall" efficiency as a single value [13,24,36,37].”
MethodA Flexible Sigmoid Function of Determinate Growth
YIN, X. (2003) · Annals of Botany · doi:10.1093/aob/mcg029 · Cited by 795 · cited 1×
“The Richards equation is a more flexible growth function because it has an additional parameter, which is a shape parameter that can make the Richards equation equivalent to the logistic, Gompertz, or monomolecular equations [31,32].”
MethodMathematics of quantitative kinetic PCR and the application of standard curves
Rutledge, R. G. (2003) · Nucleic Acids Research · doi:10.1093/nar/gng093 · Cited by 545
Cited by
Wilcox, T. M., McKelvey, K. S., Young, M. K., Sepulveda, A. J., Shepard, B. B., Jane, S. F., Whiteley, A. R., Lowe, W. H., & Schwartz, M. K. (2016) · Biological Conservation · doi:10.1016/j.biocon.2015.12.023 · Cited by 401
Forensic implications of PCR inhibition—A review
Alaeddini, R. (2012) · Forensic Science International: Genetics · doi:10.1016/j.fsigen.2011.08.006 · Cited by 292
Ruijter, J. M., Pfaffl, M. W., Zhao, S., Spiess, A. N., Boggy, G., Blom, J., Rutledge, R. G., Sisti, D., Lievens, A., De Preter, K., et al. (2013) · Methods · doi:10.1016/j.ymeth.2012.08.011 · Cited by 258
Self-citationMuscle releases alpha-sarcoglycan positive extracellular vesicles carrying miRNAs in the bloodstream
Guescini, M., Canonico, B., Lucertini, F., Maggio, S., Annibalini, G., Barbieri, E., Luchetti, F., Papa, S., & Stocchi, V. (2015) · PLoS ONE · doi:10.1371/journal.pone.0125094 · Cited by 228
DNA-based techniques for authentication of processed food and food supplements
Lo, Y.-T., & Shaw, P.-C. (2018) · Food Chemistry · doi:10.1016/j.foodchem.2017.08.022 · Cited by 218
A survey of tools for the analysis of quantitative PCR (qPCR) data
Pabinger, S., Rödiger, S., Kriegner, A., Vierlinger, K., & Weinhäusel, A. (2014) · Biomolecular Detection and Quantification · doi:10.1016/j.bdq.2014.08.002 · Cited by 192
Overcoming Inhibition in Real-Time Diagnostic PCR
Hedman, J., & Rådström, P. (2013) · Methods in Molecular Biology · doi:10.1007/978-1-60327-353-4_2 · Cited by 164
Bias and Imprecision in Analysis of Real-Time Quantitative Polymerase Chain Reaction Data
Tellinghuisen, J., & Spiess, A.-N. (2015) · Analytical Chemistry · doi:10.1021/acs.analchem.5b02057 · Cited by 35
Metadata
- Authors
- Guescini, M., Sisti, D., Rocchi, M. B., Stocchi, L., & Stocchi, V.
- Venue
- BMC Bioinformatics
- Published
- 2008-07-30
- Volume
- 9
- Issue
- 1
- Pages
- 326-326
- ISSN
- 1471-2105 (ISSN-L)
- OpenAlex
- W2106072567
- Cited by
- 180
- References
- 37
- FWCI
- 2.36
- Type
- journal article
- Language
- en
- Open access
- gold
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.