A new real-time PCR method to overcome significant quantitative inaccuracy due to slight amplification inhibition
Open accessThe DOI matches its Crossref record; 37 of the 37 references it cites were found in a registry or an index.
Abstract
BACKGROUND: Real-time PCR analysis is a sensitive DNA quantification technique that has recently gained considerable attention in biotechnology, microbiology and molecular diagnostics. Although, the cycle-threshold (Ct) method is the present "gold standard", it is far from being a standard assay. Uniform reaction efficiency among samples is the most important assumption of this method. Nevertheless, some authors have reported that it may not be correct and a slight PCR efficiency decrease of about 4% could result in an error of up to 400% using the Ct method. This reaction efficiency decrease may be caused by inhibiting agents used during nucleic acid extraction or copurified from the biological sample. We propose a new method (Cy0) that does not require the assumption of equal reaction efficiency between unknowns and standard curve. RESULTS: The Cy0 method is based on the fit of Richards' equation to real-time PCR data by nonlinear regression in order to obtain the best fit estimators of reaction parameters. Subsequently, these parameters were used to calculate the Cy0 value that minimizes the dependence of its value on PCR kinetic. The Ct, second derivative (Cp), sigmoidal curve fitting method (SCF) and Cy0 methods were compared using two criteria: precision and accuracy. Our results demonstrated that, in optimal amplification conditions, these four methods are equally precise and accurate. However, when PCR efficiency was slightly decreased, diluting amplification mix quantity or adding a biological inhibitor such as IgG, the SCF, Ct and Cp methods were markedly impaired while the Cy0 method gave significantly more accurate and precise results. CONCLUSION: Our results demonstrate that Cy0 represents a significant improvement over the standard methods for obtaining a reliable and precise nucleic acid quantification even in sub-optimal amplification conditions overcoming the underestimation caused by the presence of some PCR inhibitors.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
A Flexible Growth Function for Empirical Use
RICHARDS, F. J. (1959) · Journal of Experimental Botany · doi:10.1093/jxb/10.2.290 · Cited by 4,146 · cited 1×
“The Cy0 method was performed by nonlinear regression fitting of the Richards function [25], an extension of logistic growth curve, in order to fit fluorescence readings to the 5-parameter Richards function: F F”
MethodBustin, S. (2000) · Journal of Molecular Endocrinology · doi:10.1677/jme.0.0250169 · Cited by 3,872
Assumption-free analysis of quantitative real-time polymerase chain reaction (PCR) data
Ramakers, C., Ruijter, J. M., Deprez, R. H. L., & Moorman, A. F. M. (2003) · Neuroscience Letters · doi:10.1016/s0304-3940(02)01423-4 · Cited by 3,709 · cited 3×
“However, most current methods of PCR efficiency assessment report "overall" efficiency as a single value [13, 24 ,36,37].”
MethodInfluentialQuantification of mRNA using real-time RT-PCR
Nolan, T., Hands, R. E., & Bustin, S. A. (2006) · Nature Protocols · doi:10.1038/nprot.2006.236 · Cited by 2,247 · cited 1×
“With a large dynamic range (7–8 magnitudes) and a high degree of sensitivity (5–10 molecules), the real-time PCR addresses the evident requirement for quantitative data analysis in molecular medicine, biotechnology, microbiology and diagnostics [5,6].”
BackgroundKinetic PCR Analysis: Real-time Monitoring of DNA Amplification Reactions
Higuchi, R., Fockler, C., Dollinger, G., & Watson, R. (1993) · Nature Biotechnology · doi:10.1038/nbt0993-1026 · Cited by 2,159 · cited 1×
“Background In the last few years, the real-time polymerase chain reaction (PCR) has rapidly become the most widely used technique in modern molecular biology [1-4].”
MethodLivak, K. J., Flood, S. J., Marmaro, J., Giusti, W., & Deetz, K. (1995) · Genome Research · doi:10.1101/gr.4.6.357 · Cited by 1,603
Comprehensive Algorithm for Quantitative Real-Time Polymerase Chain Reaction
Zhao, S., & Fernald, R. D. (2005) · Journal of Computational Biology · doi:10.1089/cmb.2005.12.1047 · Cited by 1,303 · cited 1×
“The main complication is that actual efficiency amplification is not constant through the PCR run being high in exponential phase and gradually declining towards the plateau phase [33-35].”
BackgroundPeirson, S. N. (2003) · Nucleic Acids Research · doi:10.1093/nar/gng073 · Cited by 843 · cited 1×
“However, most current methods of PCR efficiency assessment report "overall" efficiency as a single value [13,24,36,37].”
MethodA Flexible Sigmoid Function of Determinate Growth
YIN, X. (2003) · Annals of Botany · doi:10.1093/aob/mcg029 · Cited by 795 · cited 1×
“The Richards equation is a more flexible growth function because it has an additional parameter, which is a shape parameter that can make the Richards equation equivalent to the logistic, Gompertz, or monomolecular equations [31,32].”
MethodMathematics of quantitative kinetic PCR and the application of standard curves
Rutledge, R. G. (2003) · Nucleic Acids Research · doi:10.1093/nar/gng093 · Cited by 545
Real-time reverse transcription PCR (qRT-PCR) and its potential use in clinical diagnosis
Bustin, S. A., & Mueller, R. (2005) · Clinical Science · doi:10.1042/cs20050086 · Cited by 529 · cited 1×
“With a large dynamic range (7–8 magnitudes) and a high degree of sensitivity (5–10 molecules), the real-time PCR addresses the evident requirement for quantitative data analysis in molecular medicine, biotechnology, microbiology and diagnostics [5,6].”
BackgroundLiu, W., & Saint, D. A. (2002) · Analytical Biochemistry · doi:10.1006/abio.2001.5530 · Cited by 516 · cited 1×
“Moreover, recent publications on PCR efficiency assessment have concentrated on the analysis of individual shapes of fluorescence plots in order to estimate a dynamic efficiency value [19,20,27,38].”
BackgroundStandardized determination of real-time PCR efficiency from a single reaction set-up
Tichopad, A. (2003) · Nucleic Acids Research · doi:10.1093/nar/gng122 · Cited by 455 · cited 1×
“However, most current methods of PCR efficiency assessment report "overall" efficiency as a single value [13,24,36,37].”
MethodStatistical significance of quantitative PCR
Karlen, Y., McNair, A., Perseguers, S., Mazza, C., & Mermod, N. (2007) · BMC Bioinformatics · doi:10.1186/1471-2105-8-131 · Cited by 373
Validation of a quantitative method for real time PCR kinetics
Liu, W., & Saint, D. A. (2002) · Biochemical and Biophysical Research Communications · doi:10.1016/s0006-291x(02)00478-3 · Cited by 359 · cited 5×
“An alternative approach, proposed by Liu and Saint [18], assumes a dynamic change in efficiency fitting PCR amplification with a sigmoid function (Sigmoidal curve fitting method, SCF).”
BackgroundMethodInfluentialMeijerink, J., Mandigers, C., van de Locht, L., Tönnissen, E., Goodsaid, F., & Raemaekers, J. (2001) · The Journal of Molecular Diagnostics · doi:10.1016/s1525-1578(10)60652-6 · Cited by 298 · cited 1×
“In fact, some, if not all, of the biological samples may contain inhibitors that are not present in the standard nucleic acid samples used to construct the calibration curve, leading to an underestimation of the DNA quantities in the unknown samples [28,29].”
BackgroundLuu-The, V., Paquet, N., Calvo, E., & Cumps, J. (2005) · BioTechniques · doi:10.2144/05382rr05 · Cited by 284 · cited 1×
“The second, namely second derivative, calculates the fractional cycle where the second derivative of the real-time fluorescence intensity curve reaches the maximum value (Cp) [ 9 ].”
BackgroundSchmittgen, T. D. (2001) · Methods · doi:10.1006/meth.2001.1260 · Cited by 280
SPUD: A quantitative PCR assay for the detection of inhibitors in nucleic acid preparations
Nolan, T., Hands, R. E., Ogunkolade, W., & Bustin, S. A. (2006) · Analytical Biochemistry · doi:10.1016/j.ab.2006.01.051 · Cited by 257 · cited 1×
“0625 – 2 μg/ml) thus acting as the inhibitory agent [23].”
BackgroundJiang, J., Alderisio, K. A., Singh, A., & Xiao, L. (2005) · Applied and Environmental Microbiology · doi:10.1128/aem.71.3.1135-1141.2005 · Cited by 240 · cited 1×
“It is well-recognized that template quality is one of the most important determinants of real-time PCR reliability and reproducibility [13], and numerous authors have shown the significant reduction in the sensitivity and kinetics of real-time PCR assays caused by inhibitory components frequently found in biological s…”
BackgroundA New Generalized Logistic Sigmoid Growth Equation Compared with the Richards Growth Equation
BIRCH, C. (1999) · Annals of Botany · doi:10.1006/anbo.1999.0877 · Cited by 211
Rutledge, R. G. (2004) · Nucleic Acids Research · doi:10.1093/nar/gnh177 · Cited by 209 · cited 6×
“Furthermore, in presence of high IgG concentrations, the SCF approach, modified according to Rutledge 2004 [26], was inapplicable because it was impossible to minimize F0 value (Additional file 5).”
MethodInfluentialEvaluation of Real‐Time PCR Amplification Efficiencies to Detect PCR Inhibitors
Kontanis, E. J., & Reed, F. A. (2006) · Journal of Forensic Sciences · doi:10.1111/j.1556-4029.2006.00182.x · Cited by 166 · cited 3×
“It is well-recognized that template quality is one of the most important determinants of real-time PCR reliability and reproducibility [13], and numerous authors have shown the significant reduction in the sensitivity and kinetics of real-time PCR assays caused by inhibitory components frequently found in biological s…”
BackgroundInhibition of real-time RT–PCR quantification due to tissue-specific contaminants
Tichopád, A., Didier, A., & Pfaffl, M. W. (2003) · Molecular and Cellular Probes · doi:10.1016/j.mcp.2003.09.001 · Cited by 147 · cited 2×
“This produced different reaction kinetics, mimicking the amplification inhibition that often occurs in biological samples [17,22].”
BackgroundOn the logistic law of growth and its empirical verifications in biology
Feller, W. (1940) · Acta Biotheoretica · doi:10.1007/bf01602862 · Cited by 134 · cited 1×
“These observations are in accordance with Feller's conclusions that different Sshaped curves can be effectively fitted with various sigmoid models [ 30 ], each providing distinct F0 values.”
ResultStåhlberg, A., Åman, P., Ridell, B., Mostad, P., & Kubista, M. (2003) · Clinical Chemistry · doi:10.1373/49.1.51 · Cited by 128 · cited 1×
“In fact, some, if not all, of the biological samples may contain inhibitors that are not present in the standard nucleic acid samples used to construct the calibration curve, leading to an underestimation of the DNA quantities in the unknown samples [28, 29 ].”
BackgroundA commentary on the practical applications of competitive PCR.Preprint
Raeymaekers, L. (1995) · Genome Research · doi:10.1101/gr.5.1.91 · Cited by 118 · cited 1×
“Furthermore, this efficiency is assumed to be the same for all the standard dilutions, but some authors have reported that this assumption may be questionable [12].”
BackgroundKinetic Outlier Detection (KOD) in real-time PCR
Bar, T. (2003) · Nucleic Acids Research · doi:10.1093/nar/gng106 · Cited by 102 · cited 2×
“It is well-recognized that template quality is one of the most important determinants of real-time PCR reliability and reproducibility [13], and numerous authors have shown the significant reduction in the sensitivity and kinetics of real-time PCR assays caused by inhibitory components frequently found in biological s…”
BackgroundMethodMathematical model of real‐time PCR kinetics
Gevertz, J. L., DUNN, S. M., & Roth, C. M. (2005) · Biotechnology and Bioengineering · doi:10.1002/bit.20617 · Cited by 102 · cited 1×
“The main complication is that actual efficiency amplification is not constant through the PCR run being high in exponential phase and gradually declining towards the plateau phase [ 33-35 ].”
BackgroundFifty Years of Molecular (DNA/RNA) Diagnostics
Gingeras, T., Higuchi, R., Kricka, L. J., Lo, Y. D., & Wittwer, C. T. (2005) · Clinical Chemistry · doi:10.1373/clinchem.2004.045336 · Cited by 66
Evaluation of absolute quantitation by nonlinear regression in probe-based real-time PCR
Goll, R., Olsen, T., Cui, G., & Florholmen, J. (2006) · BMC Bioinformatics · doi:10.1186/1471-2105-7-107 · Cited by 57 · cited 9×
“These observations are in agreement with two recent studies, which reported that it is possible to obtain absolute quantification from real-time data without a standard curve, but the Ct method remains a gold standard due to the inherent errors of the multiple estimates used in nonlinear regression [ 19 ,20].”
BackgroundMethodResultInfluentialModel based analysis of real-time PCR data from DNA binding dye protocols
Alvarez, M. J., Vilá‐Ortíz, G. J., Salibe, M., Podhajcer, O. L., & Pitossi, F. J. (2007) · BMC Bioinformatics · doi:10.1186/1471-2105-8-85 · Cited by 47 · cited 3×
“Precision and accuracy of the Ct, Cp and Cy0 methods The performance of the Ct, Cp and Cy0 methods was compared in terms of precision and accuracy over a wide range of input DNA concentrations and under different reaction efficiencies obtained by decreasing the amount of amplification mix as reported in Liu and Saint…”
BackgroundMethodEstimation of the reaction efficiency in polymerase chain reaction
Lalam, N. (2006) · Journal of Theoretical Biology · doi:10.1016/j.jtbi.2006.06.001 · Cited by 47 · cited 1×
“The main complication is that actual efficiency amplification is not constant through the PCR run being high in exponential phase and gradually declining towards the plateau phase [33-35].”
BackgroundSuñén, E., Casas, N., Moreno, B. G., & Zigorraga, C. (2003) · International Journal of Food Microbiology · doi:10.1016/s0168-1605(03)00374-x · Cited by 38 · cited 1×
“It is well-recognized that template quality is one of the most important determinants of real-time PCR reliability and reproducibility [13], and numerous authors have shown the significant reduction in the sensitivity and kinetics of real-time PCR assays caused by inhibitory components frequently found in biological s…”
BackgroundPrevalence of selective inhibition of HPV‐16 DNA amplification in cervicovaginal lavages
Lefevre, J., Hankins, C. A., Pourreaux, K., Voyer, H., The Canadian Women's HIV Study Group, & Coutlée, F. (2003) · Journal of Medical Virology · doi:10.1002/jmv.10539 · Cited by 28
Statistical Diagnostics Emerging from External Quality Control of Real-Time PCR
Marubini, E., Verderio, P., Raggi, C. C., Pazzagli, M., & Orlando, C. (2004) · The International Journal of Biological Markers · doi:10.1177/172460080401900209 · Cited by 11
(2004) · PubMed Central
Cited by
Wilcox, T. M., McKelvey, K. S., Young, M. K., Sepulveda, A. J., Shepard, B. B., Jane, S. F., Whiteley, A. R., Lowe, W. H., & Schwartz, M. K. (2016) · Biological Conservation · doi:10.1016/j.biocon.2015.12.023 · Cited by 401
Forensic implications of PCR inhibition—A review
Alaeddini, R. (2012) · Forensic Science International: Genetics · doi:10.1016/j.fsigen.2011.08.006 · Cited by 292
Ruijter, J. M., Pfaffl, M. W., Zhao, S., Spiess, A. N., Boggy, G., Blom, J., Rutledge, R. G., Sisti, D., Lievens, A., De Preter, K., et al. (2013) · Methods · doi:10.1016/j.ymeth.2012.08.011 · Cited by 258
Self-citationMuscle releases alpha-sarcoglycan positive extracellular vesicles carrying miRNAs in the bloodstream
Guescini, M., Canonico, B., Lucertini, F., Maggio, S., Annibalini, G., Barbieri, E., Luchetti, F., Papa, S., & Stocchi, V. (2015) · PLoS ONE · doi:10.1371/journal.pone.0125094 · Cited by 228
DNA-based techniques for authentication of processed food and food supplements
Lo, Y.-T., & Shaw, P.-C. (2018) · Food Chemistry · doi:10.1016/j.foodchem.2017.08.022 · Cited by 218
Metadata
- Authors
- Guescini, M., Sisti, D., Rocchi, M. B., Stocchi, L., & Stocchi, V.
- Venue
- BMC Bioinformatics
- Published
- 2008-07-30
- Volume
- 9
- Issue
- 1
- Pages
- 326-326
- ISSN
- 1471-2105 (ISSN-L)
- OpenAlex
- W2106072567
- Cited by
- 180
- References
- 37
- FWCI
- 2.36
- Type
- journal article
- Language
- en
- Open access
- gold
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.