SASI-Seq: sample assurance Spike-Ins, and highly differentiating 384 barcoding for Illumina sequencing
Open accessThe DOI matches its Crossref record; 3 of the 3 references it cites were found in a registry or an index.
Abstract
BACKGROUND: A minor but significant fraction of samples subjected to next-generation sequencing methods are either mixed-up or cross-contaminated. These events can lead to false or inconclusive results. We have therefore developed SASI-Seq; a process whereby a set of uniquely barcoded DNA fragments are added to samples destined for sequencing. From the final sequencing data, one can verify that all the reads derive from the original sample(s) and not from contaminants or other samples. RESULTS: By adding a mixture of three uniquely barcoded amplicons, of different sizes spanning the range of insert sizes one would normally use for Illumina sequencing, at a spike-in level of approximately 0.1%, we demonstrate that these fragments remain intimately associated with the sample. They can be detected following even the tightest size selection regimes or exome enrichment and can report the occurrence of sample mix-ups and cross-contamination.As a consequence of this work, we have designed a set of 384 eleven-base Illumina barcode sequences that are at least 5 changes apart from each other, allowing for single-error correction and very low levels of barcode misallocation due to sequencing error. CONCLUSION: SASI-Seq is a simple, inexpensive and flexible tool that enables sample assurance, allows deconvolution of sample mix-ups and reports levels of cross-contamination between samples throughout NGS workflows.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Quail, M., Smith, M. E., Coupland, P., Otto, T. D., Harris, S. R., Connor, T. R., Bertoni, A., Swerdlow, H. P., & Gu, Y. (2012) · BMC Genomics · doi:10.1186/1471-2164-13-341 · Cited by 2,031 · cited 1×
“With the Illumina error rate less than 1% [29] this should occur at a frequency of less than 1 in 10 6 .”
BackgroundSelf-citationOptimal enzymes for amplifying sequencing libraries
Quail, M. A., Otto, T. D., Gu, Y., Harris, S. R., Skelly, T. F., McQuillan, J. A., Swerdlow, H. P., & Oyola, S. O. (2012) · Nature Methods · doi:10.1038/nmeth.1814 · Cited by 196 · cited 2×
“KK2602) as previously described [30] with 200 nM final concentration of primer PE1.”
MethodSelf-citationProposed methods for testing and selecting the ERCC external RNA controls
External RNA Controls Consortium (2005) · BMC Genomics · doi:10.1186/1471-2164-6-150 · Cited by 187 · cited 1×
“The idea of spiked-in fragments is not new; ERCC RNA spike-ins [14] are routinely used to normalise RNA expression levels between different experiments, combinations of primer pairs specifying control fragments of defined length have been advocated for genotyping studies [15] and Illumina include…”
Background
Cited by
Clinical Metagenomic Next-Generation Sequencing for Pathogen Detection
Gu, W., Miller, S., & Chiu, C. Y. (2019) · Annual Review of Pathology: Mechanisms of Disease · doi:10.1146/annurev-pathmechdis-012418-012751 · Cited by 1,458
Leukemia-associated somatic mutations drive distinct patterns of age-related clonal hemopoiesis
McKerrell, T., Park, N., Moreno, T., Grove, C. S., Ponstingl, H., Stephens, J., Crawley, C., Craig, J., Scott, M. A., Hodkinson, C., et al. (2015) · Cell Reports · doi:10.1016/j.celrep.2015.02.005 · Cited by 534
Self-citationStandards and Guidelines for Validating Next-Generation Sequencing Bioinformatics Pipelines
Roy, S., Coldren, C., Karunamurthy, A., Kip, N. S., Klee, E. W., Lincoln, S. E., Leon, A., Pullambhatla, M., Temple-Smolkin, R. L., Voelkerding, K. V., et al. (2018) · The Journal of Molecular Diagnostics · doi:10.1016/j.jmoldx.2017.11.003 · Cited by 469
Accurate multiplexing and filtering for high-throughput amplicon-sequencing
Esling, P., Lejzerowicz, F., & Pawlowski, J. (2015) · Nucleic Acids Research · doi:10.1093/nar/gkv107 · Cited by 327
Diao, Z., Han, D., Zhang, R., & Li, J. (2022) · Journal of Advanced Research · doi:10.1016/j.jare.2021.09.012 · Cited by 265
Metadata
- Authors
- Quail, M. A., Smith, M., Jackson, D., Leonard, S., Skelly, T., Swerdlow, H. P., Gu, Y., & Ellis, P.
- Venue
- BMC Genomics
- Published
- 2014
- Volume
- 15
- Issue
- 1
- Pages
- 110
- ISSN
- 1471-2164 (ISSN-L)
- OpenAlex
- W2119157396
- Cited by
- 49
- References
- 3
- FWCI
- 2.56
- Type
- journal article
- Language
- en
- Open access
- gold
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: SASI-Seq: sample assurance Spike-Ins, and highly differentiating 384 barcoding for Illumina sequencing. https://app.cochat.ai/papers/10.1186/1471-2164-15-110
- The paper
- Quail, M. A., Smith, M., Jackson, D., Leonard, S., Skelly, T., Swerdlow, H. P., Gu, Y., & Ellis, P. (2014). SASI-Seq: sample assurance Spike-Ins, and highly differentiating 384 barcoding for Illumina sequencing. BMC Genomics. https://doi.org/10.1186/1471-2164-15-110
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.