Performance comparison of four exome capture systems for deep sequencing
Open accessThe DOI matches its Crossref record; 21 of the 21 references it cites were found in a registry or an index.
Abstract
BACKGROUND: Recent developments in deep (next-generation) sequencing technologies are significantly impacting medical research. The global analysis of protein coding regions in genomes of interest by whole exome sequencing is a widely used application. Many technologies for exome capture are commercially available; here we compare the performance of four of them: NimbleGen's SeqCap EZ v3.0, Agilent's SureSelect v4.0, Illumina's TruSeq Exome, and Illumina's Nextera Exome, all applied to the same human tumor DNA sample. RESULTS: Each capture technology was evaluated for its coverage of different exome databases, target coverage efficiency, GC bias, sensitivity in single nucleotide variant detection, sensitivity in small indel detection, and technical reproducibility. In general, all technologies performed well; however, our data demonstrated small, but consistent differences between the four capture technologies. Illumina technologies cover more bases in coding and untranslated regions. Furthermore, whereas most of the technologies provide reduced coverage in regions with low or high GC content, the Nextera technology tends to bias towards target regions with high GC content. CONCLUSIONS: We show key differences in performance between the four technologies. Our data should help researchers who are planning exome sequencing to select appropriate exome capture technology for their particular application.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
The Genome Analysis Toolkit: A MapReduce framework for analyzing next-generation DNA sequencing data
McKenna, A., Hanna, M., Banks, E., Sivachenko, A., Cibulskis, K., Kernytsky, A., Garimella, K., Altshuler, D., Gabriel, S., Daly, M., et al. (2010) · Genome Research · doi:10.1101/gr.107524.110 · Cited by 27,895 · cited 2×
“We used UnifiedGenotyper, implemented in the GATK package [21], to investigate the relationship between read counts and total single nucleotide variants (SNVs) detected within different intervals.”
MethodPruitt, K. D., Tatusova, T., & Maglott, D. R. (2007) · Nucleic Acids Research · doi:10.1093/nar/gkl842 · Cited by 4,481 · cited 1×
“Many different RNA databases are available, such as RefSeq [14] and Ensembl [15], which differ in the number of non-coding RNAs and total number of exons re-ported, as well as the start and end coordinates of exons.”
Gnirke, A., Melnikov, A., Maguire, J., Rogov, P., LeProust, E. M., Brockman, W., Fennell, T., Giannoukos, G., Fisher, S., Russ, C., et al. (2009) · Nature Biotechnology · doi:10.1038/nbt.1523 · Cited by 1,433 · cited 1×
“Base composition has been shown to bias sequencing efficiency, thus coverage may be low for sequences with high GC or AT content [17].”
BackgroundThe power and promise of population genomics: from genotyping to genome typing
Luikart, G., England, P. R., Tallmon, D., Jordan, S., & Taberlet, P. (2003) · Nature Reviews Genetics · doi:10.1038/nrg1226 · Cited by 1,365 · cited 1×
“In general it remains prohibitively expensive to analyze whole genomes for population scale study, even though the cost of whole genome sequencing has fallen significantly [1].”
BackgroundAnalyzing and minimizing PCR amplification bias in Illumina sequencing libraries
Aird, D., Ross, M. G., Chen, W.-S., Danielsson, M., Fennell, T., Russ, C., Jaffe, D. B., Nusbaum, C., & Gnirke, A. (2011) · Genome Biology · doi:10.1186/gb-2011-12-2-r18 · Cited by 1,174 · cited 1×
“There are two primary explanations for this bias: 1) a polymerase chain reaction (PCR) amplification bias, where high or low GC content reduces the efficiency of PCR amplification [18]; and 2) a reduced efficiency of capture probe hybridization to sequences with high or low GC content [19].”
BackgroundDirect selection of human genomic loci by microarray hybridization
Albert, T. J., Molla, M. N., Muzny, D. M., Nazareth, L., Wheeler, D., Song, X., Richmond, T. A., Middle, C. M., Rodesch, M. J., Packard, C. J., et al. (2007) · Nature Methods · doi:10.1038/nmeth1111 · Cited by 681 · cited 1×
“Chip-based exome capture was the first to be developed [6,7], but required large amounts of input DNA, and was quickly replaced by more efficient solution-based capture systems.”
MethodGenome-wide in situ exon capture for selective resequencing
Hodges, E., Xuan, Z., Balija, V., Kramer, M., Molla, M. N., Smith, S. W., Middle, C. M., Rodesch, M. J., Albert, T. J., Hannon, G. J., et al. (2007) · Nature Genetics · doi:10.1038/ng.2007.42 · Cited by 677 · cited 1×
“Chip-based exome capture was the first to be developed [6,7], but required large amounts of input DNA, and was quickly replaced by more efficient solution-based capture systems.”
MethodAssessment of the sensitivity and specificity of oligonucleotide (50mer) microarrays
Kane, M. D. (2000) · Nucleic Acids Research · doi:10.1093/nar/28.22.4552 · Cited by 610 · cited 1×
“There are two primary explanations for this bias: 1) a polymerase chain reaction (PCR) amplification bias, where high or low GC content reduces the efficiency of PCR amplification [18]; and 2) a reduced efficiency of capture probe hybridization to sequences with high or low GC content [19].”
BackgroundPruitt, K. D., Harrow, J., Harte, R. A., Wallin, C., Diekhans, M., Maglott, D. R., Searle, S., Farrell, C. M., Loveland, J. E., Ruef, B. J., et al. (2009) · Genome Research · doi:10.1101/gr.080531.108 · Cited by 557 · cited 1×
“CCDS contains protein-coding sequences with high quality annotations [16].”
BackgroundPerformance comparison of exome DNA sequencing technologies
Clark, M. J., Chen, R., Lam, H. Y. K., Karczewski, K. J., Chen, R., Euskirchen, G., Butte, A. J., & Snyder, M. (2011) · Nature Biotechnology · doi:10.1038/nbt.1975 · Cited by 511 · cited 3×
“We used the methods described by Clark et al. [10] to investigate target coverage efficiency.”
BackgroundMethodInfluential
Cited by
Allio, R., Schomaker‐Bastos, A., Romiguier, J., Prosdocimi, F., Nabholz, B., & Delsuc, F. (2020) · Molecular Ecology Resources · doi:10.1111/1755-0998.13160 · Cited by 1,963
Carss, K. J., Arno, G., Erwood, M., Stephens, J., Sanchis-Juan, A., Hull, S., Megy, K., Grozeva, D., Dewhurst, E., Malka, S., et al. (2017) · The American Journal of Human Genetics · doi:10.1016/j.ajhg.2016.12.003 · Cited by 463
De novo variants in neurodevelopmental disorders with epilepsy
EuroEPINOMICS RES Consortium, Heyne, H. O., Singh, T., Stamberger, H., Abou Jamra, R., Caglayan, H., Craiu, D., De Jonghe, P., Guerrini, R., Helbig, K. L., et al. (2018) · Nature Genetics · doi:10.1038/s41588-018-0143-7 · Cited by 289
Evaluation of Hybridization Capture Versus Amplicon‐Based Methods for Whole‐Exome Sequencing
Samorodnitsky, E., Jewell, B. M., Hagopian, R., Miya, J., Wing, M. R., Lyon, E., Damodaran, S., Bhatt, D., Reeser, J. W., Datta, J., et al. (2015) · Human Mutation · doi:10.1002/humu.22825 · Cited by 274
Exome Sequencing: Current and Future Perspectives
Warr, A., Robert, C., Hume, D., Archibald, A., Deeb, N., & Watson, M. (2015) · G3 Genes|Genomes|Genetics · doi:10.1534/g3.115.018564 · Cited by 224
“Chilamakuri et al. (2014) found that the Nextera kit had increased coverage of high GC content areas as the result of altered bias in the transposome technology used during fragmentation, decreasing its overall uniformity; however, recent changes to the protocol in the new versions may have…”
BackgroundMethodInfluentialAllgäuer, M., Budczies, J., Christopoulos, P., Endris, V., Lier, A., Rempel, E., Volckmar, A.-L., Kirchner, M., von Winterfeld, M., Leichsenring, J., et al. (2018) · Translational Lung Cancer Research · doi:10.21037/tlcr.2018.08.14 · Cited by 212
Predicting DNA hybridization kinetics from sequence
Zhang, J. X., Fang, J. Z., Duan, W., Wu, L. R., Zhang, A. W., Dalchau, N., Yordanov, B., Petersen, R., Phillips, A., & Zhang, D. Y. (2018) · Nature Chemistry · doi:10.1038/nchem.2877 · Cited by 165
Challenge accepted: uncovering the role of rare genetic variants in Alzheimer’s disease
Khani, M., Gibbons, E., Bras, J., & Guerreiro, R. (2022) · Molecular Neurodegeneration · doi:10.1186/s13024-021-00505-9 · Cited by 39
“using different exome capture methods and with varying coverage [89].”
MethodComparison of SureSelect and Nextera Exome Capture Performance in Single-Cell Sequencing
Huss, W. J., Hu, Q., Glenn, S. T., Gangavarapu, K. J., Wang, J., Luce, J. D., Quinn, P. K., Brese, E. A., Zhan, F., Conroy, J. M., et al. (2018) · Human Heredity · doi:10.1159/000490506 · Cited by 8
Metadata
- Authors
- Chilamakuri, C. S., Lorenz, S., Madoui, M.-A., Vodák, D., Sun, J., Hovig, E., Myklebost, O., & Meza-Zepeda, L. A.
- Venue
- BMC Genomics
- Published
- 2014
- Volume
- 15
- Issue
- 1
- Pages
- 449
- ISSN
- 1471-2164 (ISSN-L)
- OpenAlex
- W2081823535
- Cited by
- 185
- References
- 21
- FWCI
- 17.04
- Type
- journal article
- Language
- en
- Open access
- gold
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.