Which activity monitor to use? Validity, reproducibility and user friendliness of three activity monitors
Open accessThe DOI matches its Crossref record; 9 of the 9 references it cites were found in a registry or an index.
Abstract
BACKGROUND: Health is associated with amount of daily physical activity. Recently, the identification of sedentary time as an independent factor, has gained interest. A valid and easy to use activity monitor is needed to objectively investigate the relationship between physical activity, sedentary time and health. We compared validity and reproducibility of physical activity measurement and posture identification of three activity monitors, as well as user friendliness. METHODS: Healthy volunteers wore three activity monitors simultaneously: ActivPAL3, ActiGraphGT3X and CAM. Data were acquired under both controlled (n = 5) and free-living conditions (n = 9). The controlled laboratory measurement, that included standardized walking intensity and posture allocation, was performed twice. User friendliness was evaluated with a questionnaire. Posture classification was compared with direct observation (controlled measurement) and with diaries (free living). Accelerometer intensity accuracy was tested by correlations with walking speed. User friendliness was compared between activity monitors. RESULTS: Reproducibility was at least substantial in all monitors. The difference between the two CAM measurements increased with walking intensity. Amount of correct posture classification by ActivPAL3 was 100.0% (kappa 0.98), 33.9% by ActiGraphGT3X (kappa 0.29) and 100.0% by CAM (kappa 0.99). Correlations between accelerometer intensity and walking speed were 0.98 for ActivPAL3, 1.00 for ActiGraphGT3X and 0.98 for CAM. ICCs between activity monitors and diary were 0.98 in ActivPAL3, 0.59 and 0.96 in ActiGraphGT3X and 0.98 in CAM. ActivPAL3 and ActiGraphGT3X had higher user friendliness scores than the CAM. CONCLUSIONS: The ActivPAL3 is valid, reproducible and user friendly. The posture classification by the ActiGraphGT3X is not valid, but reflection of walking intensity and user friendliness are good. The CAM is valid; however, reproducibility at higher walking intensity and user friendliness might cause problems. Further validity studies in free living are recommended.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Physical Activity in the United States Measured by Accelerometer
TROIANO, R. P., BERRIGAN, D., DODD, K. W., MÂSSE, L. C., TILERT, T., & MCDOWELL, M. (2008) · Medicine & Science in Sports & Exercise · doi:10.1249/mss.0b013e31815a51b3 · Cited by 7,638 · cited 1×
“Usually, non-wear is identified with an algorithm based on a certain amount of inactivity [29-31].”
BackgroundPrince, S. A., Adamo, K. B., Hamel, M., Hardt, J., Connor Gorber, S., & Tremblay, M. (2008) · International Journal of Behavioral Nutrition and Physical Activity · doi:10.1186/1479-5868-5-56 · Cited by 3,162 · cited 1×
“Both reproducibility and validity of self-report physical activity and sedentary behavior are variable [9,10].”
Conducting accelerometer-based activity assessments in field-based research
TROST, S. G., MCIVER, K. L., & PATE, R. R. (2005) · Medicine & Science in Sports & Exercise · doi:10.1249/01.mss.0000185657.86065.98 · Cited by 2,033
Hamilton, M. T., Hamilton, D. G., & Zderic, T. W. (2007) · Diabetes · doi:10.2337/db07-0882 · Cited by 1,655
Sedentary Behaviors and Subsequent Health Outcomes in Adults
Thorp, A. A., Owen, N., Neuhaus, M., & Dunstan, D. W. (2011) · American Journal of Preventive Medicine · doi:10.1016/j.amepre.2011.05.004 · Cited by 1,455
Sitting time and all-cause mortality risk in 222,497 Australian adults
van der Ploeg, H. P. (2012) · Archives of Internal Medicine · doi:10.1001/archinternmed.2011.2174 · Cited by 884
Measurement of Adults' Sedentary Time in Population-Based Studies
Healy, G. N., Clark, B. K., Winkler, E. A. H., Gardiner, P. A., Brown, W. J., & Matthews, C. E. (2011) · American Journal of Preventive Medicine · doi:10.1016/j.amepre.2011.05.005 · Cited by 628
Sedentary Activity Associated With Metabolic Syndrome Independent of Physical Activity
Bankoski, A., Harris, T. B., McClain, J. J., Brychta, R. J., Caserotti, P., Chen, K. Y., Berrigan, D., Troiano, R. P., & Koster, A. (2011) · Diabetes Care · doi:10.2337/dc10-0987 · Cited by 535
Accelerometers and pedometers: methodology and clinical application
Corder, K., Brage, S., & Ekelund, U. (2007) · Current Opinion in Clinical Nutrition and Metabolic Care · doi:10.1097/mco.0b013e328285d883 · Cited by 339 · cited 1×
“The validity and reliability of accelerometry measurements rely on wearing time [22].”
Background
Cited by
Considerations when using the activPAL monitor in field-based research with adult populations
Edwardson, C. L., Winkler, E. A. H., Bodicoat, D. H., Yates, T., Davies, M. J., Dunstan, D. W., & Healy, G. N. (2017) · Journal of Sport and Health Science · doi:10.1016/j.jshs.2016.02.002 · Cited by 502
Winkler, E. A. H., Bodicoat, D. H., Healy, G. N., Bakrania, K., Yates, T., Owen, N., Dunstan, D. W., & Edwardson, C. L. (2016) · Physiological Measurement · doi:10.1088/0967-3334/37/10/1653 · Cited by 287
Duvivier, B. M. F. M., Schaper, N. C., Hesselink, M. K. C., van Kan, L., Stienen, N., Winkens, B., Koster, A., & Savelberg, H. H. C. M. (2017) · Diabetologia · doi:10.1007/s00125-016-4161-7 · Cited by 212
Self-citationValidity of the ActivPAL monitor to distinguish postures: A systematic review
O’Brien, M. W., Wu, Y., Petterson, J. L., Bray, N. W., & Kimmerly, D. S. (2022) · Gait & Posture · doi:10.1016/j.gaitpost.2022.03.002 · Cited by 81
Prince, S. A., Reed, J. L., Cotie, L. M., Harris, J., Pipe, A. L., & Reid, R. D. (2018) · International Journal of Cardiology · doi:10.1016/j.ijcard.2018.07.082 · Cited by 40
Metadata
- Authors
- Berendsen, B. A., Hendriks, M. R., Meijer, K., Plasqui, G., Schaper, N. C., & Savelberg, H. H.
- Venue
- BMC Public Health
- Published
- 2014-07-24
- Volume
- 14
- Issue
- 1
- Pages
- 749-749
- ISSN
- 1471-2458 (ISSN-L)
- OpenAlex
- W2092572700
- Cited by
- 104
- References
- 9
- FWCI
- 6.61
- Type
- journal article
- Language
- en
- Open access
- gold
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Which activity monitor to use? Validity, reproducibility and user friendliness of three activity monitors. https://app.cochat.ai/papers/10.1186/1471-2458-14-749
- The paper
- Berendsen, B. A., Hendriks, M. R., Meijer, K., Plasqui, G., Schaper, N. C., & Savelberg, H. H. (2014). Which activity monitor to use? Validity, reproducibility and user friendliness of three activity monitors. BMC Public Health. https://doi.org/10.1186/1471-2458-14-749
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.