Validation of a high-throughput fermentation system based on online monitoring of biomass and fluorescence in continuously shaken microtiter plates
Open accessThe DOI matches its Crossref record; 26 of the 26 references it cites were found in a registry or an index.
Abstract
Background: An advanced version of a recently reported high-throughput fermentation system with online measurement, called BioLector, and its validation is presented. The technology combines high-throughput screening and high-information content by applying online monitoring of scattered light and fluorescence intensities in continuously shaken microtiter plates. Various examples in calibration of the optical measurements, clone and media screening and promoter characterization are given. Results: Bacterial and yeast biomass concentrations of up to 50 g/L cell dry weight could be linearly correlated to scattered light intensities. In media screening, the BioLector could clearly demonstrate its potential for detecting different biomass and product yields and deducing specific growth rates for quantitatively evaluating media and nutrients. Growth inhibition due to inappropriate buffer conditions could be detected by reduced growth rates and a temporary increase in NADH fluorescence. GFP served very well as reporter protein for investigating the promoter regulation under different carbon sources in yeast strains. A clone screening of 90 different GFP-expressing Hansenula polymorpha clones depicted the broad distribution of growth behavior and an even stronger distribution in GFP expression. The importance of mass transfer conditions could be demonstrated by varying filling volumes of an E. coli culture in 96 well MTP. The different filling volumes cause a deviation in the culture growth and acidification both monitored via scattered light intensities and the fluorescence of a pH indicator, respectively. Conclusion: The BioLector technology is a very useful tool to perform quantitative microfermentations under engineered reaction conditions. With this technique, specific yields and rates can be directly deduced from online biomass and product concentrations, which is superior to existing technologies such as microplate readers or optode-based cultivation systems. In particular, applications with strong demand on high-throughput such as clone and media screening and systems biology can benefit from its simple handling, the high quantitative information content and its capacity of automation.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Introduction to advantages and problems of shaken cultures
Büchs, J. (2001) · Biochemical Engineering Journal · doi:10.1016/s1369-703x(00)00106-6 · Cited by 388 · cited 1×
“This most commonly applied operation mode in screening [27] reaches a cell dry weight of usually below 15 g/L [2].”
BackgroundSelf-citationReporter proteins for in vivo fluorescence without oxygen
Drepper, T., Eggert, T., Circolone, F., Heck, A., Krauß, U., Guterl, J.-K., Wendorff, M., Losi, A., Gärtner, W., & Jaeger, K.-E. (2007) · Nature Biotechnology · doi:10.1038/nbt1293 · Cited by 383
Online respiration activity measurement (OTR, CTR, RQ) in shake flasks
Anderlei, T., Zang, W., Papaspyrou, M., & Büchs, J. (2004) · Biochemical Engineering Journal · doi:10.1016/s1369-703x(03)00181-5 · Cited by 365
Self-citationRegulation of methanol utilisation pathway genes in yeasts.
Hartner, F. S., & Glieder, A. (2006) · Microbial Cell Factories · doi:10.1186/1475-2859-5-39 · Cited by 335
Miniature bioreactors: current practices and future opportunities.
Betts, J. I., & Baganz, F. (2006) · Microbial Cell Factories · doi:10.1186/1475-2859-5-21 · Cited by 294
Characterization of gas–liquid mass transfer phenomena in microtiter plates
Hermann, R., Lehmann, M., & Büchs, J. (2003) · Biotechnology and Bioengineering · doi:10.1002/bit.10456 · Cited by 216
Self-citationMembrane‐aerated microbioreactor for high‐throughput bioprocessing
Zanzotto, A., Szita, N., Boccazzi, P., Lessard, P., Sinskey, A. J., & Jensen, K. F. (2004) · Biotechnology and Bioengineering · doi:10.1002/bit.20140 · Cited by 211
Wilms, B., Hauck, A., Reuss, M., Syldatk, C., Mattes, R., Siemann, M., & Altenbuchner, J. (2001) · Biotechnology and Bioengineering · doi:10.1002/bit.1041 · Cited by 201
John, G. T., Klimant, I., Wittmann, C., & Heinzle, E. (2003) · Biotechnology and Bioengineering · doi:10.1002/bit.10534 · Cited by 199
Two-Dimensional Fluorescence Spectroscopy: A New Tool for On-Line Bioprocess Monitoring
Marose, S., Lindemann, C., & Scheper, T. (1998) · Biotechnology Progress · doi:10.1021/bp970124o · Cited by 190
Cited by
Itaconic acid – A biotechnological process in change
Klement, T., & Büchs, J. (2013) · Bioresource Technology · doi:10.1016/j.biortech.2012.11.141 · Cited by 282
Self-citationMustafi, N., Grünberger, A., Kohlheyer, D., Bott, M., & Frunzke, J. (2012) · Metabolic Engineering · doi:10.1016/j.ymben.2012.02.002 · Cited by 225
“For the dipeptide feeding assay, the main culture was inoculated to an OD600 of 3 and cultivated in a BioLector microbioreactor system (Kensy et al., 2009).”
Biosensor-driven adaptive laboratory evolution of l-valine production in Corynebacterium glutamicum
Mahr, R., Gätgens, C., Gätgens, J., Polen, T., Kalinowski, J., & Frunzke, J. (2015) · Metabolic Engineering · doi:10.1016/j.ymben.2015.09.017 · Cited by 178
“Online monitoring of growth and fluorescence was performed in 48-well microtiter FlowerPlates (MFPs) in the BioLector cultivation system (m2p-labs GmbH, Aachen, Germany) (Kensy et al., 2009).”
Claßen, J., Aupert, F., Reardon, K. F., Solle, D., & Scheper, T. (2017) · Analytical and Bioanalytical Chemistry · doi:10.1007/s00216-016-0068-x · Cited by 176
Single-cell microfluidics: opportunity for bioprocess development
Grünberger, A., Wiechert, W., & Kohlheyer, D. (2014) · Current Opinion in Biotechnology · doi:10.1016/j.copbio.2014.02.008 · Cited by 175
Fluorescence Spectroscopy and Chemometric Modeling for Bioprocess Monitoring
Faassen, S., & Hitzmann, B. (2015) · Sensors · doi:10.3390/s150510271 · Cited by 120
“Fungi Batch 2D-Fluorescence [48–51] Saccharomyces cerevisiae Batch, Fed-Batch 2D-Fluorescence [10,11,27,37,52–55] Claviceps purpurea Hansenula polymorpha Batch Batch 2D-Fluorescence NAD(P)H fluorescence [8,40]”
MethodBruder, S., Reifenrath, M., Thomik, T., Boles, E., & Herzog, K. (2016) · Microbial Cell Factories · doi:10.1186/s12934-016-0526-3 · Cited by 78
“[10], formulating a purely linear correlation, given by”
BackgroundFink, M., Vazulka, S., Egger, E., Jarmer, J., Grabherr, R., Cserjan‐Puschmann, M., & Striedner, G. (2019) · Biotechnology Journal · doi:10.1002/biot.201800637 · Cited by 41
Morschett, H., Schiprowski, D., Müller, C., Mertens, K., Felden, P., Meyer, J., Wiechert, W., & Oldiges, M. (2017) · Biotechnology and Bioengineering · doi:10.1002/bit.26051 · Cited by 19
“Though, state-of-the-art non-invasive online analytics remain exclusively available in microbial microbioreactors (Kensy et al., 2009; Weuster-Botz et al., 2005).”
Background
Metadata
- Authors
- Kensy, F., Zang, E., Faulhammer, C., Tan, R.-K., & Büchs, J.
- Venue
- Microbial Cell Factories
- Published
- 2009-06-04
- Volume
- 8
- Issue
- 1
- Pages
- 31-31
- ISSN
- 1475-2859 (ISSN-L)
- OpenAlex
- W2106943551
- Cited by
- 253
- References
- 26
- FWCI
- 5.64
- Type
- journal article
- Language
- en
- Open access
- gold
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.