The DOI matches its Crossref record; 10 of the 10 references it cites were found in a registry or an index.
Real time electrocardiogram QRS detection using combined adaptive threshold
Open accessAbstract
Background: QRS and ventricular beat detection is a basic procedure for electrocardiogram (ECG) processing and analysis. Large variety of methods have been proposed and used, featuring high percentages of correct detection. Nevertheless, the problem remains open especially with respect to higher detection accuracy in noisy ECGs Methods: A real-time detection method is proposed, based on comparison between absolute values of summed differentiated electrocardiograms of one of more ECG leads and adaptive threshold. The threshold combines three parameters: an adaptive slew-rate value, a second value which rises when high-frequency noise occurs, and a third one intended to avoid missing of low amplitude beats. Two algorithms were developed: Algorithm 1 detects at the current beat and Algorithm 2 has an RR interval analysis component in addition. The algorithms are self-adjusting to the thresholds and weighting constants, regardless of resolution and sampling frequency used. They operate with any number L of ECG leads, self-synchronize to QRS or beat slopes and adapt to beat-to-beat intervals. Results: The algorithms were tested by an independent expert, thus excluding possible author's influence, using all 48 full-length ECG records of the MIT-BIH arrhythmia database. The results were: sensitivity Se = 99.69 % and specificity Sp = 99.65 % for Algorithm 1 and Se = 99.74 % and Sp = 99.65 % for Algorithm 2. Conclusion: The statistical indices are higher than, or comparable to those, cited in the scientific literature.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
A Real-Time QRS Detection Algorithm
Pan, J., & Tompkins, W. J. (1985) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.1985.325532 · Cited by 7,855
Detection of ECG characteristic points using wavelet transforms
Li, C., Zheng, C., & Tai, C. (1995) · IEEE Transactions on Biomedical Engineering · doi:10.1109/10.362922 · Cited by 1,597
A comparison of the noise sensitivity of nine QRS detection algorithms
Friesen, G. M., Jannett, T. C., Jadallah, M. A., Yates, S. L., Quint, S. R., & Nagle, H. T. (1990) · IEEE Transactions on Biomedical Engineering · doi:10.1109/10.43620 · Cited by 1,043 · cited 1×
“Friesen et al. [ 2 ] have presented a comparison of nine QRS detection algorithms, based on: i) amplitude and first derivative, ii) first derivative only, iii) first and second derivative, and iv) digital filtering.”
MethodECG beat detection using filter banks
Afonso, V. X., Tompkins, W. J., Nguyen, T. Q., & Luo, S. (1999) · IEEE Transactions on Biomedical Engineering · doi:10.1109/10.740882 · Cited by 728
Genetic design of optimum linear and nonlinear QRS detectors
Poli, R., Cagnoni, S., & Valli, G. (1995) · IEEE Transactions on Biomedical Engineering · doi:10.1109/10.469381 · Cited by 238
Developments in ECG acquisition, preprocessing, parameter measurement, and recording
Duskalov, I. K., Dotsinsky, I., & Christov, I. I. (1998) · IEEE Engineering in Medicine and Biology Magazine · doi:10.1109/51.664031 · Cited by 156
Self-citationA robust-digital QRS-detection algorithm for arrhythmia monitoring
Ligtenberg, A., & Kunt, M. (1983) · Computers and Biomedical Research · doi:10.1016/0010-4809(83)90027-7 · Cited by 96
A QRS complex detection algorithm using electrocardiogram leads
Moraes, J. C. T. D. B., de Freitas, M. M. D. B., Vilani, F. N., & Costa, E. V. (2003) · Computers in cardiology · doi:10.1109/cic.2002.1166743 · Cited by 72
Ventricular beat detection in single channel electrocardiograms
Dotsinsky, I., & Stoyanov, T. (2004) · BioMedical Engineering OnLine · doi:10.1186/1475-925x-3-3 · Cited by 55
Ventricular beat classifier using fractal number clustering
Bakardjian, H. (1992) · Medical & Biological Engineering & Computing · doi:10.1007/bf02457828 · Cited by 14
Cited by
Removal of FMRI environment artifacts from EEG data using optimal basis sets
Niazy, R. K., Beckmann, C. F., Iannetti, G. D., Brady, J. M., & Smith, S. M. (2005) · NeuroImage · doi:10.1016/j.neuroimage.2005.06.067 · Cited by 567
Analysis of First-Derivative Based QRS Detection Algorithms
Arzeno, N. M., Deng, Z.-D., & Poon, C.-S. (2008) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2007.912658 · Cited by 413
QRS detection using K-Nearest Neighbor algorithm (KNN) and evaluation on standard ECG databases
Saini, I., Singh, D., & Khosla, A. (2013) · Journal of Advanced Research · doi:10.1016/j.jare.2012.05.007 · Cited by 346
Bota, P. J., Wang, C., Fred, A. L. N., & Placido Da Silva, H. (2019) · IEEE Access · doi:10.1109/access.2019.2944001 · Cited by 322
Ritter, P., & Villringer, A. (2006) · Neuroscience & Biobehavioral Reviews · doi:10.1016/j.neubiorev.2006.06.008 · Cited by 294
Metadata
- Authors
- Christov, I. I.
- Venue
- BioMedical Engineering OnLine
- Published
- 2004-08-27
- Volume
- 3
- Issue
- 1
- Pages
- 28-28
- ISSN
- 1475-925X (ISSN-L)
- OpenAlex
- W2098816250
- Cited by
- 464
- References
- 10
- FWCI
- 5.58
- Type
- journal article
- Language
- en
- Open access
- gold
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.