BACKGROUND: The Vegetative and Minimally Conscious States (VS; MCS) are characterized by absent or highly disordered signs of awareness alongside preserved sleep-wake cycles. According to international diagnostic guidelines, sleep-wake cycles are assessed by means of observations of variable periods of eye-opening and eye-closure. However, there is little empirical evidence for true circadian sleep-wake cycling in these patients, and there have been no large-scale investigations of the validity of this diagnostic criterion. METHODS: We measured the circadian sleep-wake rhythms of 55 VS and MCS patients by means of wrist actigraphy, an indirect method that is highly correlated with polysomnographic estimates of sleeping/waking. RESULTS: Contrary to the diagnostic guidelines, a significant proportion of patients did not exhibit statistically reliable sleep-wake cycles. The circadian rhythms of VS patients were significantly more impaired than those of MCS patients, as were the circadian rhythms of patients with non-traumatic injuries relative to those with traumatic injuries. The reliability of the circadian rhythms were significantly predicted by the patients' levels of visual and motor functioning, consistent with the putative biological generators of these rhythms. CONCLUSIONS: The high variability across diagnoses and etiologies highlights the need for improved guidelines for the assessment of sleep-wake cycles in VS and MCS, and advocates the use of actigraphy as an inexpensive and non-invasive alternative.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1186/1741-7015-11-18

Cites

6 of 6 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 6 references

Cited by

See all 72

Metadata

Authors
Cruse, D., Thibaut, A., Demertzi, A., Nantes, J. C., Bruno, M.-A., Gosseries, O., Vanhaudenhuyse, A., Bekinschtein, T. A., Owen, A. M., & Laureys, S.
Venue
BMC Medicine
Published
2013-01-24
Volume
11
Issue
1
Pages
18-18
ISSN
1741-7015 (ISSN-L)
OpenAlex
W2157280093
Cited by
72
References
6
FWCI
5.19
Type
journal article
Language
en
Open access
gold

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Actigraphy assessments of circadian sleep-wake cycles in the Vegetative and Minimally Conscious States. https://app.cochat.ai/papers/10.1186/1741-7015-11-18
The paper
Cruse, D., Thibaut, A., Demertzi, A., Nantes, J. C., Bruno, M.-A., Gosseries, O., Vanhaudenhuyse, A., Bekinschtein, T. A., Owen, A. M., & Laureys, S. (2013). Actigraphy assessments of circadian sleep-wake cycles in the Vegetative and Minimally Conscious States. BMC Medicine. https://doi.org/10.1186/1741-7015-11-18

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.