Student or educator? Sign up with your school email and get 6 months of Pro free.
CoChat

The DOI matches its Crossref record; 24 of the 24 references it cites were found in a registry or an index.

Reliability of Sleep Measures from Four Personal Health Monitoring Devices Compared to Research-Based Actigraphy and Polysomnography

Open access

Abstract

Polysomnography (PSG) is the “gold standard” for monitoring sleep. Alternatives to PSG are of interest for clinical, research, and personal use. Wrist-worn actigraph devices have been utilized in research settings for measures of sleep for over two decades. Whether sleep measures from commercially available devices are similarly valid is unknown. We sought to determine the validity of five wearable devices: Basis Health Tracker, Misfit Shine, Fitbit Flex, Withings Pulse O2, and a research-based actigraph, Actiwatch Spectrum. We used Wilcoxon Signed Rank tests to assess differences between devices relative to PSG and correlational analysis to assess the strength of the relationship. Data loss was greatest for Fitbit and Misfit. For all devices, we found no difference and strong correlation of total sleep time with PSG. Sleep efficiency differed from PSG for Withings, Misfit, Fitbit, and Basis, while Actiwatch mean values did not differ from that of PSG. Only mean values of sleep efficiency (time asleep/time in bed) from Actiwatch correlated with PSG, yet this correlation was weak. Light sleep time differed from PSG (nREM1 + nREM2) for all devices. Measures of Deep sleep time did not differ from PSG (SWS + REM) for Basis. These results reveal the current strengths and limitations in sleep estimates produced by personal health monitoring devices and point to a need for future development.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.3390/s16050646

Cites

24 of 24 references verified0 citation errors · 0 not checkable

Statistics

Figures

Figure 1 Bland-Altmann plots for total sleep time (minutes) for the Basis, the Fitbit, the Misfit, the Spectrum, and the Withings compared to PSG (adjusted values). The x-axis is the mean of the two devices, and the y-axis represents PSG minus the device. Dotted line represents two standard deviations from the mean.
Figure 1 Bland-Altmann plots for total sleep time (minutes) for the Basis, the Fitbit, the Misfit, the Spectrum, and the Withings compared to PSG (adjusted values). The x-axis is the mean of the two devices, and the y-axis represents PSG minus the device. Dotted line represents two standard deviations from the mean.CC BY · PubMed Central
Figure 2 Bland-Altmann plots for sleep efficiency (%) for the Basis, Fitbit, Misfit, Withings, and Actiwatch compared to PSG (adjusted values). The x-axis is the mean of the two devices, and the y-axis represents PSG minus the device. Dotted line represents two standard deviations from the mean.
Figure 2 Bland-Altmann plots for sleep efficiency (%) for the Basis, Fitbit, Misfit, Withings, and Actiwatch compared to PSG (adjusted values). The x-axis is the mean of the two devices, and the y-axis represents PSG minus the device. Dotted line represents two standard deviations from the mean.CC BY · PubMed Central
Figure 3 Bland-Altmann plots for Deep Sleep (top row) and Light Sleep (bottom row), each in minutes, for the Basis, the Misfit, and the Withings (adjusted values). The x-axis is the mean of the two devices, and the y-axis represents PSG minus the device. Dotted line represents two standard deviations from the mean.
Figure 3 Bland-Altmann plots for Deep Sleep (top row) and Light Sleep (bottom row), each in minutes, for the Basis, the Misfit, and the Withings (adjusted values). The x-axis is the mean of the two devices, and the y-axis represents PSG minus the device. Dotted line represents two standard deviations from the mean.CC BY · PubMed Central

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 24 references

Cited by

See all 314

Metadata

Authors
Mantua, J., Gravel, N., & Spencer, R.
Affiliations
University of Massachusetts Amherst (US)
Corresponding author
Spencer, Rebecca
Venue
Sensors
Publisher
MDPI AG
Published
2016-05-05
Volume
16
Issue
5
Pages
646
ISSN
1424-8220 (ISSN-L)
OpenAlex
W2346707803
Cited by
314
References
24
Citations by year
2026: 12 · 2025: 21 · 2024: 23 · 2023: 32 · 2022: 22 · 2021: 35 · 2020: 47 · 2019: 60 · 2018: 30 · 2017: 29 · 2016: 2
FWCI
57.25
Type
journal article
Language
en
Open access
Locations
  • Sensors (publishedVersion, cc-by)
  • Europe PMC (PubMed Central) (publishedVersion, cc-by)
  • PubMed Central (publishedVersion, cc-by)
  • PubMed (publishedVersion)
  • Scholarworks (University of Massachusetts Amherst) (submittedVersion, cc-by)
  • DOAJ (DOAJ: Directory of Open Access Journals) (submittedVersion, cc-by-sa)
  • ScholarWorks@UMassAmherst (University of Massachusetts Amherst) (submittedVersion, cc-by)
Topics
  • Social Sciences › Psychology › Experimental and Cognitive Psychology › Sleep and related disorders
  • Physical Sciences › Engineering › Biomedical Engineering › Non-Invasive Vital Sign Monitoring
  • Life Sciences › Neuroscience › Endocrine and Autonomic Systems › Circadian rhythm and melatonin
Keywords
sleep monitoring, wearable devices, actigraphy, polysomnography, device validity, total sleep time, sleep efficiency, light sleep, slow-wave sleep, NREM sleep, REM sleep, Fitbit, misfit
MeSH terms
Humans, Sleep, Wrist, Reproducibility of Results, Polysomnography, Actigraphy

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Reliability of Sleep Measures from Four Personal Health Monitoring Devices Compared to Research-Based Actigraphy and Polysomnography. https://app.cochat.ai/papers/10.3390/s16050646
The paper
Mantua, J., Gravel, N., & Spencer, R. (2016). Reliability of Sleep Measures from Four Personal Health Monitoring Devices Compared to Research-Based Actigraphy and Polysomnography. Sensors. https://doi.org/10.3390/s16050646

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.