Autonomous identification of freezing of gait in Parkinson's disease from lower-body segmental accelerometry

Open access

The DOI matches its Crossref record; 33 of the 34 references it cites were found in a registry or an index.

Abstract

BACKGROUND: We have previously published a technique for objective assessment of freezing of gait (FOG) in Parkinson's disease (PD) from a single shank-mounted accelerometer. Here we extend this approach to evaluate the optimal configuration of sensor placement and signal processing parameters using seven sensors attached to the lumbar back, thighs, shanks and feet. METHODS: Multi-segmental acceleration data was obtained from 25 PD patients performing 134 timed up and go tasks, and clinical assessment of FOG was performed by two experienced raters from video. Four metrics were used to compare objective and clinical measures; the intraclass correlation coefficient (ICC) for number of FOG episodes and the percent time frozen per trial; and the sensitivity and specificity of FOG detection. RESULTS: The seven-sensor configuration was the most robust, scoring highly on all measures of performance (ICC number of FOG 0.75; ICC percent time frozen 0.80; sensitivity 84.3%; specificity 78.4%). A simpler single-shank sensor approach provided similar ICC values and exhibited a high sensitivity to FOG events, but specificity was lower at 66.7%. Recordings from the lumbar sensor offered only moderate agreement with the clinical raters in terms of absolute number and duration of FOG events (likely due to musculoskeletal attenuation of lower-limb 'trembling' during FOG), but demonstrated a high sensitivity (86.2%) and specificity (82.4%) when considered as a binary test for the presence/absence of FOG within a single trial. CONCLUSIONS: The seven-sensor approach was the most accurate method for quantifying FOG, and is best suited to demanding research applications. A single shank sensor provided measures comparable to the seven-sensor approach but is relatively straightforward in execution, facilitating clinical use. A single lumbar sensor may provide a simple means of objective FOG detection given the ubiquitous nature of accelerometers in mobile telephones and other belt-worn devices.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1186/1743-0003-10-19

Cites

33 of 33 references verified0 citation errors · 0 not checkable

Statistics

Figures

Figure 1 Screen image of the FOG tagging software developed by the investigators. The video image shows a PD patient performing the timed up-and-go (TUG) task, in which subjects start from a seated position and walk 5 m to a target box marked on the floor with tape, execute a turn, and return to the seated position. Clinicians reviewed the video and indicated a FOG event by holding down the 'T' key, resulting in a FOG tag (red rectangle) which could be resized by dragging the ends horizontally in time, which moved the video by a corresponding amount. The video cursor could also be dragged forwards and backwards in time to facilitate repeat viewing of FOG events.
Figure 1 Screen image of the FOG tagging software developed by the investigators. The video image shows a PD patient performing the timed up-and-go (TUG) task, in which subjects start from a seated position and walk 5 m to a target box marked on the floor with tape, execute a turn, and return to the seated position. Clinicians reviewed the video and indicated a FOG event by holding down the 'T' key, resulting in a FOG tag (red rectangle) which could be resized by dragging the ends horizontally in time, which moved the video by a corresponding amount. The video cursor could also be dragged forwards and backwards in time to facilitate repeat viewing of FOG events.CC BY · PubMed Central
Figure 2 A Vertical acceleration data from the right shank during a TUG task of 43-s duration. The grey rectangle indicates FOG as determined by the clinical raters. B At each point in time acceleration data was sampled from a window (black rectangle - set to a width of 5 s in this instance) and a power spectrum calculated (inset). The ratio of power (area under the curve) in the freeze (3-8 Hz) and locomotor (0-3 Hz) bands from these spectra was determined to form an index of FOG (iFOG). C The iFOG waveform (shown here truncated at 10) was used to identify freezing using a threshold (set to 3 in this example); any periods in which the iFOG waveform was above threshold were tagged as a FOG event. D Vertical acceleration from the lumbar sensor was attenuated relative to the shank but still exhibited similar high frequency characteristics, enabling FOG detection E.
Figure 2 A Vertical acceleration data from the right shank during a TUG task of 43-s duration. The grey rectangle indicates FOG as determined by the clinical raters. B At each point in time acceleration data was sampled from a window (black rectangle - set to a width of 5 s in this instance) and a power spectrum calculated (inset). The ratio of power (area under the curve) in the freeze (3-8 Hz) and locomotor (0-3 Hz) bands from these spectra was determined to form an index of FOG (iFOG). C The iFOG waveform (shown here truncated at 10) was used to identify freezing using a threshold (set to 3 in this example); any periods in which the iFOG waveform was above threshold were tagged as a FOG event. D Vertical acceleration from the lumbar sensor was attenuated relative to the shank but still exhibited similar high frequency characteristics, enabling FOG detection E.CC BY · PubMed Central
Figure 3 Visual representation of the dataset generated by a single TUG trial. Each of the seven sensors generated an acceleration trace; each trace was processed with sampling windows of 2.5, 5, 7.5 and 10 s to generate four iFOG waveforms (the ratio of freeze to locomotor band power); fourteen binary traces from each of the four iFOG waveforms were then formed using an iFOG threshold of 0.5 to 7 in steps of 0.5, resulting in a total of 56 binary FOG traces per sensor, and 392 per TUG trial. Each binary waveform provided a measure of number of FOG events and the percent time frozen.
Figure 3 Visual representation of the dataset generated by a single TUG trial. Each of the seven sensors generated an acceleration trace; each trace was processed with sampling windows of 2.5, 5, 7.5 and 10 s to generate four iFOG waveforms (the ratio of freeze to locomotor band power); fourteen binary traces from each of the four iFOG waveforms were then formed using an iFOG threshold of 0.5 to 7 in steps of 0.5, resulting in a total of 56 binary FOG traces per sensor, and 392 per TUG trial. Each binary waveform provided a measure of number of FOG events and the percent time frozen.CC BY · PubMed Central
Figure 4 Agreement between clinical assessment and accelerometry (as measured by the intraclass correlation coefficient, ICC) for number of FOG events (A-D) and percent time frozen (E-H), as a function of sensor location, sampling window width, and threshold.
Figure 4 Agreement between clinical assessment and accelerometry (as measured by the intraclass correlation coefficient, ICC) for number of FOG events (A-D) and percent time frozen (E-H), as a function of sensor location, sampling window width, and threshold.CC BY · PubMed Central
Figure 5 Sensitivity (A-D) and specificity (E-H) of accelerometer-based detection of FOG, as a function of sensor location, sampling window width, and threshold.
Figure 5 Sensitivity (A-D) and specificity (E-H) of accelerometer-based detection of FOG, as a function of sensor location, sampling window width, and threshold.CC BY · PubMed Central

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 33 references

Cited by

See all 204

Metadata

Authors
Moore, S. T., Yungher, D. A., Morris, T. R., Dilda, V., MacDougall, H. G., Shine, J. M., Naismith, S. L., & Lewis, S. J.
Affiliations
  • Icahn School of Medicine at Mount Sinai (US)
  • The University of Sydney (AU)
Corresponding author
Moore, Steven T
Venue
Journal of NeuroEngineering and Rehabilitation
Published
2013
Volume
10
Issue
1
Pages
19
ISSN
1743-0003 (ISSN-L)
OpenAlex
W2122354382
Cited by
204
References
34
Citations by year
2026: 8 · 2025: 11 · 2024: 9 · 2023: 18 · 2022: 18 · 2021: 24 · 2020: 17 · 2019: 20 · 2018: 17 · 2017: 15 · 2016: 17 · 2015: 12 · 2014: 12 · 2013: 5
FWCI
39.85
Type
journal article
Language
en
Open access
Licence
cc-by
Locations
  • Journal of NeuroEngineering and Rehabilitation (publishedVersion, cc-by)
  • Europe PMC (PubMed Central) (publishedVersion, cc-by)
  • PubMed Central (publishedVersion, cc-by)
  • PubMed (publishedVersion)
  • Acquire (CQUniversity) (submittedVersion, cc-by)
  • Figshare (submittedVersion, cc-by)
Funders
  • National Aeronautics and Space Administration (NNX09AL14G, NNX12AM25G)
  • National Space Biomedical Research Institute (1008117)
  • University of Sydney
  • Garnett Passe and Rodney Williams Memorial Foundation
  • National Health and Medical Research Council (1008117)
Topics
  • Health Sciences › Health Professions › Physical Therapy, Sports Therapy and Rehabilitation › Balance, Gait, and Falls Prevention
  • Physical Sciences › Computer Science › Computer Vision and Pattern Recognition › Context-Aware Activity Recognition Systems
  • Physical Sciences › Engineering › Biomedical Engineering › Gait Recognition and Analysis
Keywords
freezing of gait, Parkinson's disease, accelerometry, sensor placement, Timed Up and Go test, objective gait assessment, wearable sensors
MeSH terms
Biomechanical Phenomena, Data Interpretation, Statistical, Electrodes, Female, Foot, Humans, Leg, Locomotion, Lumbosacral Region, Male, Musculoskeletal Physiological Phenomena, Neuropsychological Tests, Parkinson Disease, Psychomotor Performance, Signal Processing, Computer-Assisted, Software, Thigh, Reproducibility of Results, Cohort Studies, Gait Disorders, Neurologic, Lower Extremity

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Autonomous identification of freezing of gait in Parkinson's disease from lower-body segmental accelerometry. https://app.cochat.ai/papers/10.1186/1743-0003-10-19
The paper
Moore, S. T., Yungher, D. A., Morris, T. R., Dilda, V., MacDougall, H. G., Shine, J. M., Naismith, S. L., & Lewis, S. J. (2013). Autonomous identification of freezing of gait in Parkinson's disease from lower-body segmental accelerometry. Journal of NeuroEngineering and Rehabilitation. https://doi.org/10.1186/1743-0003-10-19

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.