Study of stability of time-domain features for electromyographic pattern recognition
Open accessThe DOI matches its Crossref record; 32 of the 32 references it cites were found in a registry or an index.
Abstract
Background: Significant progress has been made towards the clinical application of human-machine interfaces (HMIs) based on electromyographic (EMG) pattern recognition for various rehabilitation purposes. Making this technology practical and available to patients with motor deficits requires overcoming real-world challenges, such as physical and physiological changes, that result in variations in EMG signals and systems that are unreliable for long-term use. In this study, we aimed to address these challenges by (1) investigating the stability of time-domain EMG features during changes in the EMG signals and (2) identifying the feature sets that would provide the most robust EMG pattern recognition. Methods: Variations in EMG signals were introduced during physical experiments. We identified three disturbances that commonly affect EMG signals: EMG electrode location shift, variation in muscle contraction effort, and muscle fatigue. The impact of these disturbances on individual features and combined feature sets was quantified by changes in classification performance. The robustness of feature sets was evaluated by a stability index developed in this study. Results: Muscle fatigue had the smallest effect on the studied EMG features, while electrode location shift and varying effort level significantly reduced the classification accuracy for most of the features. Under these disturbances, the most stable EMG feature set with combination of four features produced at least 16.0% higher classification accuracy than the least stable set. EMG autoregression coefficients and cepstrum coefficients showed the most robust classification performance of all studied time-domain features. Conclusions: Selecting appropriate EMG feature combinations can overcome the impact of the studied disturbances on EMG pattern classification to a certain extent; however, this simple solution is still inadequate. Stabilizing electrode contact locations and developing effective classifier training strategies are suggested to further improve the robustness of HMIs based on EMG pattern recognition.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
A new strategy for multifunction myoelectric control
Hudgins, B., Parker, P., & Scott, R. N. (1993) · IEEE Transactions on Biomedical Engineering · doi:10.1109/10.204774 · Cited by 2,149 · cited 1×
“Investigation of Time-Domain Features Eleven frequently suggested time-domain features with high computational efficiency [10,12,15,26-28] for realtime EMG pattern recognition were assessed.”
Muscles Alive—their functions revealed by electromyography
(1963) · Postgraduate Medical Journal · doi:10.1136/pgmj.39.449.162-b · Cited by 1,772
A robust, real-time control scheme for multifunction myoelectric control
Englehart, K., & Hudgins, B. (2003) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2003.813539 · Cited by 1,743 · cited 3×
“EMG pattern recognition is an advanced, intelligent signal processing technology and has been proposed as a potential method for reliable user intent classification [8,10].”
MethodTargeted Muscle Reinnervation for Real-time Myoelectric Control of Multifunction Artificial Arms
Kuiken, T. A. (2009) · JAMA · doi:10.1001/jama.2009.116 · Cited by 1,089 · cited 1×
“In the field of rehabilitation engineering, EMG signals are one of the major neural control sources for powered upper-limb prostheses [1,2], powered orthoses/ exoskeletons [3,4], rehabilitation robots [5,6], robotic wheelchairs [7], and assistive computers [8].”
BackgroundSelf-citationClassification of the myoelectric signal using time-frequency based representations
Englehart, K., Hudgins, B., Parker, P. A., & Stevenson, M. (1999) · Medical Engineering & Physics · doi:10.1016/s1350-4533(99)00066-1 · Cited by 645
Control of Multifunctional Prosthetic Hands by Processing the Electromyographic Signal
Zecca, M., Micera, S., Carrozza, M. C., & Dario, P. (2002) · Critical Reviews? in Biomedical Engineering · doi:10.1615/critrevbiomedeng.v30.i456.80 · Cited by 606 · cited 3×
“Investigation of Time-Domain Features Eleven frequently suggested time-domain features with high computational efficiency [10,12,15,26-28] for realtime EMG pattern recognition were assessed.”
MethodResultKaplan, E. (1962) · The Journal of Bone & Joint Surgery · doi:10.2106/00004623-196244060-00031 · Cited by 589
Control of Multifunctional Prosthetic Hands by Processing the Electromyographic Signal
Zecca, M., Micera, S., Carrozza, M. C., & Dario, P. (2017) · Critical Reviews in Biomedical Engineering · doi:10.1615/critrevbiomedeng.v45.i1-6.150 · Cited by 570
A Comparison of Surface and Intramuscular Myoelectric Signal Classification
Hargrove, L. J., Englehart, K., & Hudgins, B. (2007) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2006.889192 · Cited by 518
A Strategy for Identifying Locomotion Modes Using Surface Electromyography
Huang, H., Kuiken, T. A., & Lipschutz, R. D. (2009) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2008.2003293 · Cited by 512
Self-citationEMG feature evaluation for movement control of upper extremity prostheses
Zardoshti-Kermani, M., Wheeler, B. C., Badie, K., & Hashemi, R. M. (1995) · IEEE Transactions on Rehabilitation Engineering · doi:10.1109/86.481972 · Cited by 477 · cited 13×
“force [ 12 ]. The optimal EMG signal processor consists of”
BackgroundMethodResultInfluentialA myosignal-based powered exoskeleton system
Rosen, J., Brand, M., Fuchs, M. B., & Arcan, M. (2001) · IEEE Transactions on Systems, Man, and Cybernetics - Part A: Systems and Humans · doi:10.1109/3468.925661 · Cited by 437 · cited 1×
“In the field of rehabilitation engineering, EMG signals are one of the major neural control sources for powered upper-limb prostheses [1,2], powered orthoses/ exoskeletons [3,4], rehabilitation robots [5,6], robotic wheelchairs [7], and assistive computers [8].”
BackgroundEnergy supply and muscle fatigue in humans
SAHLIN, K., TONKONOGI, M., & SÖDERLUND, K. (1998) · Acta Physiologica Scandinavica · doi:10.1046/j.1365-201x.1998.0298f.x · Cited by 419
Anatomic guide for the electromyographer--the limbs
Delagi, E. F., & Perotto, A. (1980) · Thomas eBooks · Cited by 260
Myoelectric signal conduction velocity and spectral parameters: influence of force and time
Broman, H., Bilotto, G., & De Luca, C. J. (1985) · Journal of Applied Physiology · doi:10.1152/jappl.1985.58.5.1428 · Cited by 260
Customized interactive robotic treatment for stroke: EMG-triggered therapy
Dipietro, L., Ferraro, M., Palazzolo, J. J., Krebs, H. I., Volpe, B. T., & Hogan, N. (2005) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2005.850423 · Cited by 241
Sensinger, J. W., Lock, B. A., & Kuiken, T. A. (2009) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2009.2023282 · Cited by 239
Self-citationDecoding a New Neural–Machine Interface for Control of Artificial Limbs
Zhou, P., Lowery, M. M., Englehart, K. B., Huang, H., Li, G., Hargrove, L., Dewald, J. P. A., & Kuiken, T. A. (2007) · Journal of Neurophysiology · doi:10.1152/jn.00178.2007 · Cited by 215 · cited 2×
“For each movement class, the concatenated signals were separated into 150 ms analysis windows with 75 ms (50% of duration) of overlap [25].”
MethodSelf-citationSahlin, K., & Ren, J. M. (1989) · Journal of Applied Physiology · doi:10.1152/jappl.1989.67.2.648 · Cited by 210
Graupe, D., Salahi, J., & Kohn, K. H. (1982) · Journal of Biomedical Engineering · doi:10.1016/0141-5425(82)90021-8 · Cited by 205 · cited 2×
“Investigation of Time-Domain Features Eleven frequently suggested time-domain features with high computational efficiency [10,12,15,26-28] for realtime EMG pattern recognition were assessed.”
BackgroundMechanisms of fatigue differ after low‐ and high‐force fatiguing contractions in men and women
Yoon, T., Schlinder Delap, B., Griffith, E. E., & Hunter, S. K. (2007) · Muscle & Nerve · doi:10.1002/mus.20844 · Cited by 178
Human-machine interfaces based on EMG and EEG applied to robotic systems
Ferreira, A., Celeste, W. C., Cheein, F. A., Bastos-Filho, T., Sarcinelli-Filho, M., & Carelli, R. O. (2008) · Journal of NeuroEngineering and Rehabilitation · doi:10.1186/1743-0003-5-10 · Cited by 172
Stein, J., Narendran, K., McBean, J., Krebs, K., & Hughes, R. (2007) · American Journal of Physical Medicine & Rehabilitation · doi:10.1097/phm.0b013e3180383cc5 · Cited by 170
Real-time intelligent pattern recognition algorithm for surface EMG signals
Khezri, M., & Jahed, M. (2007) · BioMedical Engineering OnLine · doi:10.1186/1475-925x-6-45 · Cited by 166
West, W., Hicks, A. L., Clements, L., & Dowling, J. (1995) · European Journal of Applied Physiology · doi:10.1007/bf00240408 · Cited by 153
The effect of electrode displacements on pattern recognition based myoelectric control
Hargrove, L., Englehart, K., & Hudgins, B. (2006) · 2006 International Conference of the IEEE Engineering in Medicine and Biology Society · doi:10.1109/iembs.2006.260681 · Cited by 135
Practical Methods for Controlling Powered Upper-Extremity Prostheses
Williams, T. W. (1990) · Assistive Technology · doi:10.1080/10400435.1990.10132142 · Cited by 71
EMG-Based Neuro-Fuzzy Control of a 4DOF Upper-Limb Power-Assist Exoskeleton
Kiguchi, K., Imada, Y., & Liyanage, M. (2007) · 2007 29th Annual International Conference of the IEEE Engineering in Medicine and Biology Society · doi:10.1109/iembs.2007.4352969 · Cited by 67
Development and Quantitative Performance Evaluation of a Noninvasive EMG Computer Interface
Choi, C., Micera, S., Carpaneto, J., & Kim, J. (2008) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2008.2005950 · Cited by 65
Smith, I., & Newham, D. J. (2006) · Journal of Applied Physiology · doi:10.1152/japplphysiol.00571.2006 · Cited by 59
Factors influencing quantified surface EMGs
Vigreux, B., Cnockaert, J. C., & Pertuzon, E. (1979) · European Journal of Applied Physiology · doi:10.1007/bf00421659 · Cited by 54
On automatic identification of upper-limb movements using small-sized training sets of EMG signals
Micera, S., Sabatini, A. M., & Dario, P. (2000) · Medical Engineering & Physics · doi:10.1016/s1350-4533(00)00069-2 · Cited by 40
Cited by
Feature reduction and selection for EMG signal classification
Phinyomark, A., Phukpattaranont, P., & Limsakul, C. (2012) · Expert Systems with Applications · doi:10.1016/j.eswa.2012.01.102 · Cited by 1,542
A wearable biosensing system with in-sensor adaptive machine learning for hand gesture recognition
Moin, A., Zhou, A., Rahimi, A., Menon, A., Benatti, S., Alexandrov, G., Tamakloe, S., Ting, J., Yamamoto, N., Khan, Y., et al. (2020) · Nature Electronics · doi:10.1038/s41928-020-00510-8 · Cited by 680
EMG feature evaluation for improving myoelectric pattern recognition robustness
Phinyomark, A., Quaine, F., Charbonnier, S., Serviere, C., Tarpin-Bernard, F., & Laurillau, Y. (2013) · Expert Systems with Applications · doi:10.1016/j.eswa.2013.02.023 · Cited by 643
Control of Hand Prostheses Using Peripheral Information
Micera, S., Carpaneto, J., & Raspopovic, S. (2010) · IEEE Reviews in Biomedical Engineering · doi:10.1109/rbme.2010.2085429 · Cited by 403
A Review of Classification Techniques of EMG Signals during Isotonic and Isometric Contractions
Nazmi, N., Abdul Rahman, M., Yamamoto, S.-I., Ahmad, S., Zamzuri, H., & Mazlan, S. (2016) · Sensors · doi:10.3390/s16081304 · Cited by 377
Metadata
- Authors
- Tkach, D., Huang, H., & Kuiken, T. A.
- Venue
- Journal of NeuroEngineering and Rehabilitation
- Published
- 2010-05-21
- Volume
- 7
- Issue
- 1
- Pages
- 21-21
- ISSN
- 1743-0003 (ISSN-L)
- OpenAlex
- W2110119146
- Cited by
- 582
- References
- 32
- FWCI
- 10.38
- Type
- journal article
- Language
- en
- Open access
- gold
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.