Development and pilot testing of HEXORR: Hand EXOskeleton Rehabilitation Robot
Open accessThe DOI matches its Crossref record; 46 of the 46 references it cites were found in a registry or an index.
Abstract
Background: Following acute therapeutic interventions, the majority of stroke survivors are left with a poorly functioning hemiparetic hand. Rehabilitation robotics has shown promise in providing patients with intensive therapy leading to functional gains. Because of the hand's crucial role in performing activities of daily living, attention to hand therapy has recently increased. Methods: This paper introduces a newly developed Hand Exoskeleton Rehabilitation Robot (HEXORR). This device has been designed to provide full range of motion (ROM) for all of the hand's digits. The thumb actuator allows for variable thumb plane of motion to incorporate different degrees of extension/flexion and abduction/adduction. Compensation algorithms have been developed to improve the exoskeleton's backdrivability by counteracting gravity, stiction and kinetic friction. We have also designed a force assistance mode that provides extension assistance based on each individual's needs. A pilot study was conducted on 9 unimpaired and 5 chronic stroke subjects to investigate the device's ability to allow physiologically accurate hand movements throughout the full ROM. The study also tested the efficacy of the force assistance mode with the goal of increasing stroke subjects' active ROM while still requiring active extension torque on the part of the subject. Results: For 12 of the hand digits'15 joints in neurologically normal subjects, there were no significant ROM differences (P > 0.05) between active movements performed inside and outside of HEXORR. Interjoint coordination was examined in the 1 st and 3 rd digits, and no differences were found between inside and outside of the device (P > 0.05). Stroke subjects were capable of performing free hand movements inside of the exoskeleton and the force assistance mode was successful in increasing active ROM by 43 ± 5% (P < 0.001) and 24 ± 6% (P = 0.041) for the fingers and thumb, respectively. Conclusions: Our pilot study shows that this device is capable of moving the hand's digits through nearly the entire ROM with physiologically accurate trajectories. Stroke subjects received the device intervention well and device impedance was minimized so that subjects could freely extend and flex their digits inside of HEXORR. Our active force-assisted condition was successful in increasing the subjects' ROM while promoting active participation.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
The assessment and analysis of handedness: The Edinburgh inventory
Oldfield, R. C. (1971) · Neuropsychologia · doi:10.1016/0028-3932(71)90067-4 · Cited by 35,900
The post-stroke hemiplegic patient. 1. a method for evaluation of physical performance
Fugl-Meyer, A., Jääskö, L., Leyman, I., Olsson, S., & Steglind, S. (1975) · Journal of Rehabilitation Medicine · doi:10.2340/1650197771331 · Cited by 5,564
Schmidt, R. A., & Bjork, R. A. (1992) · Psychological Science · doi:10.1111/j.1467-9280.1992.tb00029.x · Cited by 1,582
Kwakkel, G., Kollen, B. J., van der Grond, J., & Prevo, A. J. H. (2003) · Stroke · doi:10.1161/01.str.0000087172.16305.cd · Cited by 1,412
Lum, P. S., Burgar, C. G., Shor, P. C., Majmundar, M., & Van der Loos, M. (2002) · Archives of Physical Medicine and Rehabilitation · doi:10.1053/apmr.2001.33101 · Cited by 1,159
Duncan, P. W., Bode, R. K., Min Lai, S., & Perera, S. (2003) · Archives of Physical Medicine and Rehabilitation · doi:10.1016/s0003-9993(03)00035-2 · Cited by 908
Development of robots for rehabilitation therapy: the Palo Alto VA/Stanford experience.
Burgar, C. G., Lum, P. S., Shor, P. C., & der Loos, H. F. M. V. (2000) · PubMed · Cited by 800
Self-citationPatient- cooperative strategies for robot-aided treadmill training: first experimental results
Riener, R., Lunenburger, L., Jezernik, S., Anderschitz, M., Colombo, G., & Dietz, V. (2005) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2005.848628 · Cited by 729
Rehabilitation Robotics: Performance-Based Progressive Robot-Assisted Therapy
Krebs, H. I., Palazzolo, J. J., Dipietro, L., Ferraro, M., Krol, J., Rannekleiv, K., Volpe, B. T., & Hogan, N. (2003) · Autonomous Robots · doi:10.1023/a:1024494031121 · Cited by 714 · cited 1×
“This indicates that the assistance forces were too high and extended the thumb Schabowsky et al. Journal of NeuroEngineering and Rehabilitation 2010, 7:36 http://www.jneuroengrehab.com/content/7/1/36 Page 13 of 16 on past subject performance [ 51 ,52].”
BackgroundRobot-based hand motor therapy after stroke
Takahashi, C. D., Der-Yeghiaian, L., Le, V., Motiwala, R. R., & Cramer, S. C. (2008) · Brain · doi:10.1093/brain/awm311 · Cited by 624
Cited by
Soft robotic glove for combined assistance and at-home rehabilitation
Polygerinos, P., Wang, Z., Galloway, K. C., Wood, R. J., & Walsh, C. J. (2015) · Robotics and Autonomous Systems · doi:10.1016/j.robot.2014.08.014 · Cited by 1,617
A survey on robotic devices for upper limb rehabilitation
Maciejasz, P., Eschweiler, J., Gerlach-Hahn, K., Jansen-Troy, A., & Leonhardt, S. (2014) · Journal of NeuroEngineering and Rehabilitation · doi:10.1186/1743-0003-11-3 · Cited by 1,210
Current hand exoskeleton technologies for rehabilitation and assistive engineering
Heo, P., Gu, G. M., Lee, S.-J., Rhee, K., & Kim, J. (2012) · International Journal of Precision Engineering and Manufacturing · doi:10.1007/s12541-012-0107-2 · Cited by 517
Assisting hand function after spinal cord injury with a fabric-based soft robotic glove
Cappello, L., Meyer, J. T., Galloway, K. C., Peisner, J. D., Granberry, R., Wagner, D. A., Engelhardt, S., Paganoni, S., & Walsh, C. J. (2018) · Journal of NeuroEngineering and Rehabilitation · doi:10.1186/s12984-018-0391-x · Cited by 249
“, rehabilitation of the wrist [6, 7], the hand [8, 9], and the individual fingers [10] (for exhaustive reviews see [11, 12]), however the design trade-off for high forces that characterize these rigid mechanical designs is their limited portability due to the weight of the electromechanical actuators and their rigid f…”
BackgroundBlank, A. A., French, J. A., Pehlivan, A. U., & O’Malley, M. K. (2014) · Current Physical Medicine and Rehabilitation Reports · doi:10.1007/s40141-014-0056-z · Cited by 240
“Later devices aimed to expand the capabilities of robotic therapeutic devices by targeting the more distal segments of the upper limb, with wrist and hand modules to attach to previously developed arm devices [9,37-39], standalone wrist and/or hand devices [6,40-43], or whole limb devices that target the shoulder, elb…”
BackgroundA Review of Active Hand Exoskeletons for Rehabilitation and Assistance
du Plessis, T., Djouani, K., & Oosthuizen, C. (2021) · Robotics · doi:10.3390/robotics10010040 · Cited by 218
“[12] Redundant (four-bar linkage), gear train electric motors Cerebral vascular disease (Stroke)”
BackgroundInfluentialHand Rehabilitation Robotics on Poststroke Motor Recovery
Yue, Z., Zhang, X., & Wang, J. (2017) · Behavioural Neurology · doi:10.1155/2017/3908135 · Cited by 195
A Powered Finger–Thumb Wearable Hand Exoskeleton With Self-Aligning Joint Axes
Cempini, M., Cortese, M., & Vitiello, N. (2015) · IEEE/ASME Transactions on Mechatronics · doi:10.1109/tmech.2014.2315528 · Cited by 193
“Devices based on the former [17], [18] are precise, robust, and can pro-”
BackgroundAgarwal, P., Fox, J., Yun, Y., O’Malley, M. K., & Deshpande, A. D. (2015) · The International Journal of Robotics Research · doi:10.1177/0278364915598388 · Cited by 189
“…CPM,1 Kinetec Maestra Portable Hand CPM,2 Ren et al. (2009)) or active assistance, where the human hand actively interacts with the device and the device reacts as per the interaction based on a feedback (e.g. position sensing) (Jones et al., 2014; Schabowsky et al., 2010; Ueki et al., 2012).”
BackgroundA structured overview of trends and technologies used in dynamic hand orthoses
Bos, R. A., Haarman, C. J. W., Stortelder, T., Nizamis, K., Herder, J. L., Stienen, A. H. A., & Plettenburg, D. H. (2016) · Journal of NeuroEngineering and Rehabilitation · doi:10.1186/s12984-016-0168-z · Cited by 162
“Reported arguments include the increased possibilities for both position and torque control [64], high mechanical bandwidth [65] and general performance in the torquevelocity space [13].”
BackgroundMethod
Metadata
- Authors
- Schabowsky, C. N., Godfrey, S. B., Holley, R. J., & Lum, P. S.
- Venue
- Journal of NeuroEngineering and Rehabilitation
- Published
- 2010-07-28
- Volume
- 7
- Issue
- 1
- Pages
- 36-36
- ISSN
- 1743-0003 (ISSN-L)
- OpenAlex
- W2167371819
- Cited by
- 280
- References
- 46
- FWCI
- 5.10
- Type
- journal article
- Language
- en
- Open access
- gold
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.