Influence of the training set on the accuracy of surface EMG classification in dynamic contractions for the control of multifunction prostheses
Open accessThe DOI matches its Crossref record; 16 of the 16 references it cites were found in a registry or an index.
Abstract
Background: For high usability, myo-controlled devices require robust classification schemes during dynamic contractions. Therefore, this study investigates the impact of the training data set in the performance of several pattern recognition algorithms during dynamic contractions. Methods: A 9 class experiment was designed involving both static and dynamic situations. The performance of various feature extraction methods and classifiers was evaluated in terms of classification accuracy. Results: It is shown that, combined with a threshold to detect the onset of the contraction, current pattern recognition algorithms used on static conditions provide relatively high classification accuracy also on dynamic situations. Moreover, the performance of the pattern recognition algorithms tested significantly improved by optimizing the choice of the training set. Finally, the results also showed that rather simple approaches for classification of time domain features provide results comparable to more complex classification methods of wavelet features. Conclusions: Non-stationary surface EMG signals recorded during dynamic contractions can be accurately classified for the control of multi-function prostheses.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
A new strategy for multifunction myoelectric control
Hudgins, B., Parker, P., & Scott, R. N. (1993) · IEEE Transactions on Biomedical Engineering · doi:10.1109/10.204774 · Cited by 2,149 · cited 3×
“Transient surface EMG have been accurately classified using the transition as a whole[2], and stationary situations (isometric contractions) have been extensively investigated in the past decades, showing promising classification results [7,10,11].”
BackgroundMethodA robust, real-time control scheme for multifunction myoelectric control
Englehart, K., & Hudgins, B. (2003) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2003.813539 · Cited by 1,743 · cited 2×
“A sampling window of 125 ms with a delay of 30 ms has been shown to be a good trade-off between decision delay and accuracy using the majority vote [12].”
MethodClassification of the myoelectric signal using time-frequency based representations
Englehart, K., Hudgins, B., Parker, P. A., & Stevenson, M. (1999) · Medical Engineering & Physics · doi:10.1016/s1350-4533(99)00066-1 · Cited by 645 · cited 2×
“In preliminary studies, the Coiflet wavelet of order 4 has shown the best results amongst the different orders of Daubechies, Coiflet and Symmlet wavelets, and thus it was selected as the mother wavelet in the current study [15].”
BackgroundMethodHuang, Y., Englehart, K. B., Hudgins, B., & Chan, A. D. C. (2005) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2005.856295 · Cited by 643 · cited 1×
“The classification can be performed by a large variety of methods, including linear discriminant analysis [5], support vector machines [6], or artificial neural networks [2].”
BackgroundThe optimal controller delay for myoelectric prostheses
Farrell, T. R., & Weir, R. F. (2007) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2007.891391 · Cited by 438 · cited 1×
“These choices make the response time in this study acceptable for prosthetic devices, as it is generally assumed that a delay shorter than 300 ms is acceptable for myoelectric control [13].”
BackgroundFunctional Separation of EMG Signals via ARMA Identification Methods for Prosthesis Control Purposes
Graupe, D., & Cline, W. K. (1975) · IEEE Transactions on Systems, Man, and Cybernetics · doi:10.1109/tsmc.1975.5408479 · Cited by 354 · cited 1×
“Various feature extraction methods have been explored, such as those involving time-domain features [2], variance and autoregressive coefficients [3], or time-frequency based features [4].”
MethodChu, J.-U., Moon, I., Lee, Y.-J., Kim, S.-K., & Mun, M.-S. (2007) · IEEE/ASME Transactions on Mechatronics · doi:10.1109/tmech.2007.897262 · Cited by 299 · cited 2×
“Transient surface EMG have been accurately classified using the transition as a whole[2], and stationary situations (isometric contractions) have been extensively investigated in the past decades, showing promising classification results [7,10, 11 ].”
ResultOnline Electromyographic Control of a Robotic Prosthesis
Shenoy, P., Miller, K. J., Crawford, B., & Rao, R. P. N. (2008) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2007.909536 · Cited by 285
Lucas, M.-F., Gaufriau, A., Pascual, S., Doncarli, C., & Farina, D. (2008) · Biomedical Signal Processing and Control · doi:10.1016/j.bspc.2007.09.002 · Cited by 253 · cited 2×
“Each classifier was trained using learning sets of features extracted by one of two methods: Time Domain features and Auto Regressive coefficients (TD +AR) (as in [10]), which are simple features extracted from the signal, and the marginals of the Wavelet Transform coefficients (WT) (as in [14]).”
MethodSelf-citationHargrove, L. J., Li, G., Englehart, K. B., & Hudgins, B. S. (2009) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2008.2008171 · Cited by 211 · cited 3×
“According to previous work [ 7 ], it is expected that the results of this study will translate to patients, potentially with a decrease in the overall accuracy.”
MethodResultInfluentialMyoelectric Prostheses: state of the art
Scott, R. N., & Parker, P. A. (1988) · Journal of Medical Engineering & Technology · doi:10.3109/03091908809030173 · Cited by 171
Solnik, S., DeVita, P., Rider, P. M., Long, B. L., & Hortobágyi, T. (2008) · PubMed · Cited by 135
Sebelius, F., Eriksson, L., Balkenius, C., & Laurell, T. (2006) · Journal of Medical Engineering & Technology · doi:10.1080/03091900512331332546 · Cited by 57
Muceli, S., Jiang, N., & Farina, D. (2010) · Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC) · doi:10.1109/iembs.2010.5627622 · Cited by 40 · cited 1×
“kinematics can be estimated by training its association with the surface EMG of the contralateral limb with an artificial neural network [ 8 ,9].”
MethodSelf-citationApplying Genetic Programming To Control Of An Artificial Arm
Farry, K. A., Fernandez, J. J., Abramczyk, R., Novy, M., & Atkins, D. J. (1997) · DukeSpace (Duke University) · Cited by 23
Hargrove, L. J., Scheme, E., Englehart, K. B., & Hudgins, B. (2007) · Conference proceedings · doi:10.1109/iembs.2007.4353851 · Cited by 12
Cited by
Farina, D., Jiang, N., Rehbaum, H., Holobar, A., Graimann, B., Dietl, H., & Aszmann, O. C. (2014) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2014.2305111 · Cited by 992
Self-citationEMG feature evaluation for improving myoelectric pattern recognition robustness
Phinyomark, A., Quaine, F., Charbonnier, S., Serviere, C., Tarpin-Bernard, F., & Laurillau, Y. (2013) · Expert Systems with Applications · doi:10.1016/j.eswa.2013.02.023 · Cited by 643
A Review of Classification Techniques of EMG Signals during Isotonic and Isometric Contractions
Nazmi, N., Abdul Rahman, M., Yamamoto, S.-I., Ahmad, S., Zamzuri, H., & Mazlan, S. (2016) · Sensors · doi:10.3390/s16081304 · Cited by 377
Al-Timemy, A. H., Khushaba, R. N., Bugmann, G., & Escudero, J. (2016) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2015.2445634 · Cited by 336
Al-Timemy, A. H., Bugmann, G., Escudero, J., & Outram, N. (2013) · IEEE Journal of Biomedical and Health Informatics · doi:10.1109/jbhi.2013.2249590 · Cited by 326
Metadata
- Authors
- Lorrain, T., Jiang, N., & Farina, D.
- Venue
- Journal of NeuroEngineering and Rehabilitation
- Published
- 2011-05-09
- Volume
- 8
- Issue
- 1
- Pages
- 25-25
- ISSN
- 1743-0003 (ISSN-L)
- OpenAlex
- W2128756490
- Cited by
- 165
- References
- 16
- FWCI
- 7.11
- Type
- journal article
- Language
- en
- Open access
- gold
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.