Gaming control using a wearable and wireless EEG-based brain-computer interface device with novel dry foam-based sensors
Open accessThe DOI matches its Crossref record; 45 of the 45 references it cites were found in a registry or an index.
Abstract
A brain-computer interface (BCI) is a communication system that can help users interact with the outside environment by translating brain signals into machine commands. The use of electroencephalographic (EEG) signals has become the most common approach for a BCI because of their usability and strong reliability. Many EEG-based BCI devices have been developed with traditional wet- or micro-electro-mechanical-system (MEMS)-type EEG sensors. However, those traditional sensors have uncomfortable disadvantage and require conductive gel and skin preparation on the part of the user. Therefore, acquiring the EEG signals in a comfortable and convenient manner is an important factor that should be incorporated into a novel BCI device. In the present study, a wearable, wireless and portable EEG-based BCI device with dry foam-based EEG sensors was developed and was demonstrated using a gaming control application. The dry EEG sensors operated without conductive gel; however, they were able to provide good conductivity and were able to acquire EEG signals effectively by adapting to irregular skin surfaces and by maintaining proper skin-sensor impedance on the forehead site. We have also demonstrated a real-time cognitive stage detection application of gaming control using the proposed portable device. The results of the present study indicate that using this portable EEG-based BCI device to conveniently and effectively control the outside world provides an approach for researching rehabilitation engineering.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
IEEE Transactions on Biomedical Engineering
(2025) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.10 · Cited by 1,400
Research Methods and Statistics in Psychology
Coolican, H., & Coolican, H. (2017) · Psychology Press eBooks · doi:10.4324/9780203769836 · Cited by 1,174
Dry-Contact and Noncontact Biopotential Electrodes: Methodological Review
Chi, Y. M., Jung, T.-P., & Cauwenberghs, G. (2010) · IEEE Reviews in Biomedical Engineering · doi:10.1109/rbme.2010.2084078 · Cited by 1,061
The Measurement, Instrumentation and Sensors Handbook
Webster, J. G. (1998) · CRC Press eBooks · doi:10.1201/9781003040019 · Cited by 1,029
Scalp electrode impedance, infection risk, and EEG data quality
Ferree, T. C., Luu, P., Russell, G. S., & Tucker, D. M. (2001) · Clinical Neurophysiology · doi:10.1016/s1388-2457(00)00533-2 · Cited by 1,005
Frequency recognition based on canonical correlation analysis for SSVEP-based BCIs
Lin, Z., Zhang, C., Wu, W., & Gao, X. (2007) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2006.889197 · Cited by 867
An efficient P300-based brain–computer interface for disabled subjects
Hoffmann, U., Vesin, J.-M., Ebrahimi, T., & Diserens, K. (2008) · Journal of Neuroscience Methods · doi:10.1016/j.jneumeth.2007.03.005 · Cited by 859 · cited 1×
“The current applications of P300-based BCI systems range from controlling a virtual hand [10] to neuroprostheses [21,23].”
BackgroundResearch Methods and Statistics in Psychology
Coolican, H., & Coolican, H. (2013) · Routledge eBooks · doi:10.4324/9780203769669 · Cited by 832
A BCI-based environmental controller for the motion-disabled
Gao, X., Xu, D., Cheng, M., & Gao, S. (2003) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2003.814449 · Cited by 637
Cognitive approaches to the development of short-term memory
Gathercole, S. E. (1999) · Trends in Cognitive Sciences · doi:10.1016/s1364-6613(99)01388-1 · Cited by 582 · cited 4×
“According to the previous studies on mental focus, the most commonly used method for measuring the state of mental focus is called the “ short-term memory test ” [39-41].”
BackgroundMethodInfluential
Cited by
Brain-Machine Interfaces: From Basic Science to Neuroprostheses and Neurorehabilitation
Lebedev, M. A., & Nicolelis, M. A. L. (2017) · Physiological Reviews · doi:10.1152/physrev.00027.2016 · Cited by 653
How about taking a low‐cost, small, and wireless EEG for a walk?
Debener, S., Minow, F., Emkes, R., Gandras, K., & de Vos, M. (2012) · Psychophysiology · doi:10.1111/j.1469-8986.2012.01471.x · Cited by 540
A Survey on Wearable Technology: History, State-of-the-Art and Current Challenges
Ometov, A., Shubina, V., Klus, L., Skibińska, J., Saafi, S., Pascacio, P., Flueratoru, L., Gaibor, D. Q., Chukhno, N., Chukhno, O., et al. (2021) · Computer Networks · doi:10.1016/j.comnet.2021.108074 · Cited by 506
Norton, J. J. S., Lee, D. S., Lee, J. W., Lee, W., Kwon, O., Won, P., Jung, S.-Y., Cheng, H., Jeong, J.-W., Akce, A., et al. (2015) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.1424875112 · Cited by 387
Past, Present, and Future of EEG-Based BCI Applications
Värbu, K., Muhammad, N., & Muhammad, Y. (2022) · Sensors · doi:10.3390/s22093331 · Cited by 321
Trends in EEG-BCI for daily-life: Requirements for artifact removal
Minguillon, J., Lopez-Gordo, M. A., & Pelayo, F. (2017) · Biomedical Signal Processing and Control · doi:10.1016/j.bspc.2016.09.005 · Cited by 289
Wireless and Wearable EEG System for Evaluating Driver Vigilance
Lin, C.-T., Chuang, C.-H., Huang, C.-S., Tsai, S.-F., Lu, S.-W., Chen, Y.-H., & Ko, L.-W. (2014) · IEEE Transactions on Biomedical Circuits and Systems · doi:10.1109/tbcas.2014.2316224 · Cited by 250
Self-citationWireless EEG: A survey of systems and studies
Niso, G., Romero, E., Moreau, J. T., Araujo, A., & Krol, L. R. (2023) · NeuroImage · doi:10.1016/j.neuroimage.2022.119774 · Cited by 244
Hinrichs, H., Scholz, M., Baum, A. K., Kam, J. W. Y., Knight, R. T., & Heinze, H.-J. (2020) · Scientific Reports · doi:10.1038/s41598-020-62154-0 · Cited by 219
Li, G., Wang, S., & Duan, Y. Y. (2018) · Sensors and Actuators B: Chemical · doi:10.1016/j.snb.2018.08.155 · Cited by 203
Towards a truly mobile auditory brain–computer interface: Exploring the P300 to take away
De Vos, M., Gandras, K., & Debener, S. (2014) · International Journal of Psychophysiology · doi:10.1016/j.ijpsycho.2013.08.010 · Cited by 203
“Several wireless EEG systems have been proposed, among which some seem to be truly portable (e.g., Dias et al., 2011; Liao et al., 2012;Wang et al., 2011).”
BackgroundMobile EEG in research on neurodevelopmental disorders: Opportunities and challenges
Lau-Zhu, A., Lau, M. P. H., & McLoughlin, G. (2019) · Developmental Cognitive Neuroscience · doi:10.1016/j.dcn.2019.100635 · Cited by 201
Kam, J. W. Y., Griffin, S., Shen, A., Patel, S., Hinrichs, H., Heinze, H.-J., Deouell, L. Y., & Knight, R. T. (2019) · NeuroImage · doi:10.1016/j.neuroimage.2018.09.012 · Cited by 188
Roy, A. M. (2022) · Biomedical Signal Processing and Control · doi:10.1016/j.bspc.2022.103496 · Cited by 187
Roy, A. M. (2022) · Engineering Applications of Artificial Intelligence · doi:10.1016/j.engappai.2022.105347 · Cited by 183
A Review of Issues Related to Data Acquisition and Analysis in EEG/MEG Studies
Puce, A., & Hämäläinen, M. (2017) · Brain Sciences · doi:10.3390/brainsci7060058 · Cited by 181
EEG-based BCI and video games: a progress report
Kerous, B., Skola, F., & Liarokapis, F. (2018) · Virtual Reality · doi:10.1007/s10055-017-0328-x · Cited by 179
Biosensor Technologies for Augmented Brain–Computer Interfaces in the Next Decades
Liao, L.-D., Lin, C.-T., McDowell, K., Wickenden, A. E., Gramann, K., Jung, T.-P., Ko, L.-W., & Chang, J.-Y. (2012) · Proceedings of the IEEE · doi:10.1109/jproc.2012.2184829 · Cited by 169
Self-citationTang, X., Li, W., Li, X., Ma, W., & Dang, X. (2020) · Expert Systems with Applications · doi:10.1016/j.eswa.2020.113285 · Cited by 166
Sun, W., Guo, Z., Yang, Z., Wu, Y., Lan, W., Liao, Y., Wu, X., & Liu, Y. (2022) · Sensors · doi:10.3390/s22207784 · Cited by 112
“These nanoparticles improved the surface area of the electrodes, which significantly reduced interfacial impedance and thermal noise, and motion artifacts were reduced by 95%.”
BackgroundAn Imperceptible Magnetic Skin
Almansouri, A. S., Alsharif, N. A., Khan, M. A., Swanepoel, L., Kaidarova, A., Salama, K. N., & Kosel, J. (2019) · Advanced Materials Technologies · doi:10.1002/admt.201900493 · Cited by 46
Metadata
- Authors
- Liao, L.-D., Chen, C.-Y., Wang, I.-J., Chen, S.-F., Li, S.-Y., Chen, B.-W., Chang, J.-Y., & Lin, C.-T.
- Venue
- Journal of NeuroEngineering and Rehabilitation
- Published
- 2012-01-28
- Volume
- 9
- Issue
- 1
- Pages
- 5-5
- ISSN
- 1743-0003 (ISSN-L)
- OpenAlex
- W1977884228
- Cited by
- 258
- References
- 45
- FWCI
- 8.75
- Type
- journal article
- Language
- en
- Open access
- gold
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.