A multi-pad electrode based functional electrical stimulation system for restoration of grasp
Open accessThe DOI matches its Crossref record; 29 of the 29 references it cites were found in a registry or an index.
Abstract
BACKGROUND: Functional electrical stimulation (FES) applied via transcutaneous electrodes is a common rehabilitation technique for assisting grasp in patients with central nervous system lesions. To improve the stimulation effectiveness of conventional FES, we introduce multi-pad electrodes and a new stimulation paradigm. METHODS: The new FES system comprises an electrode composed of small pads that can be activated individually. This electrode allows the targeting of motoneurons that activate synergistic muscles and produce a functional movement. The new stimulation paradigm allows asynchronous activation of motoneurons and provides controlled spatial distribution of the electrical charge that is delivered to the motoneurons. We developed an automated technique for the determination of the preferred electrode based on a cost function that considers the required movement of the fingers and the stabilization of the wrist joint. The data used within the cost function come from a sensorized garment that is easy to implement and does not require calibration. The design of the system also includes the possibility for fine-tuning and adaptation with a manually controllable interface. RESULTS: The device was tested on three stroke patients. The results show that the multi-pad electrodes provide the desired level of selectivity and can be used for generating a functional grasp. The results also show that the procedure, when performed on a specific user, results in the preferred electrode configuration characteristics for that patient. The findings from this study are of importance for the application of transcutaneous stimulation in the clinical and home environments.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Yan, T., Hui-Chan, C. W. Y., & Li, L. S. W. (2005) · Stroke · doi:10.1161/01.str.0000149623.24906.63 · Cited by 324
Electrodes for transcutaneous (surface) electrical stimulation
Keller, T., & Kuhn, A. (2008) · Journal of Automatic Control · doi:10.2298/jac0802035k · Cited by 158
Self-citationElectrical stimulation for the suppression of pathological tremor
Popović Maneski, L., Jorgovanović, N., Ilić, V., Došen, S., Keller, T., Popović, M. B., & Popović, D. B. (2011) · Medical & Biological Engineering & Computing · doi:10.1007/s11517-011-0803-6 · Cited by 129
Self-citationA method to effect physiological recruitment order in electrically activated muscle
Fang, Z.-P., & Mortimer, J. T. (1991) · IEEE Transactions on Biomedical Engineering · doi:10.1109/10.76384 · Cited by 125
Malešević, N., Popović‐Maneski, L., Schwirtlich, L. B., & Popović, D. B. (2010) · Muscle & Nerve · doi:10.1002/mus.21736 · Cited by 124
Self-citationKühn, A., Keller, T., Lawrence, M., & Morari, M. (2010) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2009.2039807 · Cited by 117
Self-citationElectrical stimulation as a means for achieving recovery of function in stroke patients
Popović, D. B., Sinkjær, T., & Popović, M. B. (2009) · Neurorehabilitation · doi:10.3233/nre-2009-0498 · Cited by 112 · cited 1×
“Intensive exercise augmented by FES, termed functional electrical therapy (FET), provided evidence that there are rehabilitation benefits from effective electrical augmentation of movement during the period when this function is not achievable [8,9].”
BackgroundSelf-citationRh, N., & Ohry, A. (1990) · PubMed · Cited by 99
Multi‐Field Surface Electrode for Selective Electrical Stimulation
Popović‐Bijelić, A., Bijelić, G., Jorgovanović, N., Bojanić, D., Popović, M. B., & Popović, D. B. (2005) · Artificial Organs · doi:10.1111/j.1525-1594.2005.29075.x · Cited by 97
Self-citationProportionally controlled functional electrical stimulation of hand.
Rebersek, S., & Vodovnik, L. (1973) · PubMed · Cited by 78
Cited by
Wearable Sensors for Remote Health Monitoring
Majumder, S., Mondal, T., & Deen, M. (2017) · Sensors · doi:10.3390/s17010130 · Cited by 1,375
Advances in functional electrical stimulation (FES)
Popović, D. B. (2014) · Journal of Electromyography and Kinesiology · doi:10.1016/j.jelekin.2014.09.008 · Cited by 170
Self-citationRupp, R., Rohm, M., Schneiders, M., Kreilinger, A., & Muller-Putz, G. R. (2015) · Proceedings of the IEEE · doi:10.1109/jproc.2015.2395253 · Cited by 84
“This may be achieved by the use of textile, gelless electrodes and multipad electrodes, which dynamically compensate the negative effects on grasp patterns caused by soft tissue shifts during forearm rotation [30].”
Background
Metadata
- Authors
- Malešević, N. M., Maneski, L. Z., Ilić, V., Jorgovanović, N., Bijelić, G., Keller, T., & Popović, D. B.
- Venue
- Journal of NeuroEngineering and Rehabilitation
- Published
- 2012
- Volume
- 9
- Issue
- 1
- Pages
- 66
- ISSN
- 1743-0003 (ISSN-L)
- OpenAlex
- W2115621971
- Cited by
- 178
- References
- 29
- FWCI
- 11.46
- Type
- journal article
- Language
- en
- Open access
- gold
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.