A multi-pad electrode based functional electrical stimulation system for restoration of grasp
Open accessThe DOI matches its Crossref record; 29 of the 29 references it cites were found in a registry or an index.
Abstract
BACKGROUND: Functional electrical stimulation (FES) applied via transcutaneous electrodes is a common rehabilitation technique for assisting grasp in patients with central nervous system lesions. To improve the stimulation effectiveness of conventional FES, we introduce multi-pad electrodes and a new stimulation paradigm. METHODS: The new FES system comprises an electrode composed of small pads that can be activated individually. This electrode allows the targeting of motoneurons that activate synergistic muscles and produce a functional movement. The new stimulation paradigm allows asynchronous activation of motoneurons and provides controlled spatial distribution of the electrical charge that is delivered to the motoneurons. We developed an automated technique for the determination of the preferred electrode based on a cost function that considers the required movement of the fingers and the stabilization of the wrist joint. The data used within the cost function come from a sensorized garment that is easy to implement and does not require calibration. The design of the system also includes the possibility for fine-tuning and adaptation with a manually controllable interface. RESULTS: The device was tested on three stroke patients. The results show that the multi-pad electrodes provide the desired level of selectivity and can be used for generating a functional grasp. The results also show that the procedure, when performed on a specific user, results in the preferred electrode configuration characteristics for that patient. The findings from this study are of importance for the application of transcutaneous stimulation in the clinical and home environments.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Yan, T., Hui-Chan, C. W. Y., & Li, L. S. W. (2005) · Stroke · doi:10.1161/01.str.0000149623.24906.63 · Cited by 324
Electrodes for transcutaneous (surface) electrical stimulation
Keller, T., & Kuhn, A. (2008) · Journal of Automatic Control · doi:10.2298/jac0802035k · Cited by 158
Self-citationElectrical stimulation for the suppression of pathological tremor
Popović Maneski, L., Jorgovanović, N., Ilić, V., Došen, S., Keller, T., Popović, M. B., & Popović, D. B. (2011) · Medical & Biological Engineering & Computing · doi:10.1007/s11517-011-0803-6 · Cited by 129
Self-citationA method to effect physiological recruitment order in electrically activated muscle
Fang, Z.-P., & Mortimer, J. T. (1991) · IEEE Transactions on Biomedical Engineering · doi:10.1109/10.76384 · Cited by 125
Malešević, N., Popović‐Maneski, L., Schwirtlich, L. B., & Popović, D. B. (2010) · Muscle & Nerve · doi:10.1002/mus.21736 · Cited by 124
Self-citationKühn, A., Keller, T., Lawrence, M., & Morari, M. (2010) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2009.2039807 · Cited by 117
Self-citationElectrical stimulation as a means for achieving recovery of function in stroke patients
Popović, D. B., Sinkjær, T., & Popović, M. B. (2009) · Neurorehabilitation · doi:10.3233/nre-2009-0498 · Cited by 112 · cited 1×
“Intensive exercise augmented by FES, termed functional electrical therapy (FET), provided evidence that there are rehabilitation benefits from effective electrical augmentation of movement during the period when this function is not achievable [8,9].”
BackgroundSelf-citationRh, N., & Ohry, A. (1990) · PubMed · Cited by 99
Multi‐Field Surface Electrode for Selective Electrical Stimulation
Popović‐Bijelić, A., Bijelić, G., Jorgovanović, N., Bojanić, D., Popović, M. B., & Popović, D. B. (2005) · Artificial Organs · doi:10.1111/j.1525-1594.2005.29075.x · Cited by 97
Self-citationProportionally controlled functional electrical stimulation of hand.
Rebersek, S., & Vodovnik, L. (1973) · PubMed · Cited by 78
Automatic determination of the optimal shape of a surface electrode: Selective stimulation
Popović, D. B., & Popović, M. B. (2008) · Journal of Neuroscience Methods · doi:10.1016/j.jneumeth.2008.12.003 · Cited by 78
Self-citationArray electrode design for transcutaneous electrical stimulation: A simulation study
Kühn, A., Keller, T., Micera, S., & Morari, M. (2009) · Medical Engineering & Physics · doi:10.1016/j.medengphy.2009.05.006 · Cited by 77 · cited 1×
“A group from Eidgenössische Technische Hochschule (ETH) Zurich designed textile multi-pad electrodes with the appropriate control algorithm [16,17].”
MethodSelf-citationElectrophysiological orthosis for the upper extremity in hemiplegia: feasibility study.
Merletti, R., Aćimović, R., Grobelnik, S., & Cvilak, G. (1975) · PubMed · Cited by 72
Nguyen, R., Masani, K., Micera, S., Morari, M., & Popović, M. R. (2011) · Artificial Organs · doi:10.1111/j.1525-1594.2010.01195.x · Cited by 70
AN ELECTROPHYSIOLOGIC SPLINT FOR THE HAND.
LONG, C. (1963) · PubMed · Cited by 67
Hendricks, H. T., IJzerman, M. J., de Kroon, J. R., Groen, F. A. C. G. I. '., & Zilvold, G. (2001) · Clinical Rehabilitation · doi:10.1191/026921501672937235 · Cited by 65 · cited 1×
“; licensee BioMed Cent Commons Attribution License (http://creativec reproduction in any medium, provided the or that followed led to the development of commercial products for therapy such as the Ness H200, Bionic Glove and other similar systems [5,6].”
BackgroundPopovic, L. Z., & Malešević, N. (2009) · Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC) · doi:10.1109/iembs.2009.5333983 · Cited by 60
Self-citationAn FNS-based system for generating upper limb function in the C4 quadriplegic
Nathan, R. H. (1989) · Medical & Biological Engineering & Computing · doi:10.1007/bf02441635 · Cited by 52 · cited 4×
“Detailed maps for the stimulation of forearm muscles were presented by Nathan [13].”
MethodInfluentialA durable, low-cost electrogoniometer for dynamic measurement of joint trajectories
Wang, P. T., King, C., Do, A. H., & Nenadić, Z. (2011) · Medical Engineering & Physics · doi:10.1016/j.medengphy.2010.12.008 · Cited by 52
New Multi-Channel Transcutaneous Electrical Stimulation Technology for Rehabilitation
Keller, T., Lawrence, M., Kühn, A., & Morari, M. (2006) · Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC) · doi:10.1109/iembs.2006.259399 · Cited by 47 · cited 1×
“A group from Eidgenössische Technische Hochschule (ETH) Zurich designed textile multi-pad electrodes with the appropriate control algorithm [16,17].”
MethodSelf-citationTwitch and Tetanic Properties of Human Thenar Motor Units Paralyzed by Chronic Spinal Cord Injury
Häger, C. K., Klein, C. S., & Thomas, C. K. (2006) · Journal of Neurophysiology · doi:10.1152/jn.01339.2005 · Cited by 41
Electronic stimulators for surface neural prosthesis
Broderick, B. J., Breen, P. P., & OLaighin, G. M. (2008) · Journal of Automatic Control · doi:10.2298/jac0802025b · Cited by 35 · cited 1×
“; licensee BioMed Cent Commons Attribution License (http://creativec reproduction in any medium, provided the or that followed led to the development of commercial products for therapy such as the Ness H200, Bionic Glove and other similar systems [5,6].”
BackgroundA novel stimulation pattern improves performance during repetitive dynamic contractions
Kebaetse, M. B., Lee, S. C. K., & Binder‐Macleod, S. A. (2001) · Muscle & Nerve · doi:10.1002/mus.1065 · Cited by 33
Scott, W. B., Lee, S. C. K., Johnston, T. E., Binkley, J., & Binder‐Macleod, S. A. (2007) · Muscle & Nerve · doi:10.1002/mus.20717 · Cited by 29
Muscle twitch responses for shaping the multi-pad electrode for functional electrical stimulation
Malešević, N., Popovic, L., Bijelić, G., & Kvaščev, G. (2010) · Journal of Automatic Control · doi:10.2298/jac1001053m · Cited by 25
Self-citationAdvances in the use of electrical stimulation for the recovery of motor function
Popović, D. B., & Popović, M. B. (2011) · Progress in brain research · doi:10.1016/b978-0-444-53815-4.00005-4 · Cited by 19
Self-citationDoublet stimulation to reduce fatigue in electrically stimulated muscle during controlled leg lifts
Routh, G. R., & Durfee, W. K. (2004) · Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC) · doi:10.1109/iembs.2003.1279643 · Cited by 15
A SELF-OPTIMISING PORTABLE FES SYSTEM USING AN ELECTRODE ARRAY AND MOVEMENT SENSORS
Elsaify, A. (2005) · Figshare · Cited by 9
Optimization of multi-pad surface electrode: Selective stimulation of wrist
Popović‐Maneski, L., Malešević, N., & Popović, M. B. (2009) · IEEE EUROCON - International Conference on Computer as a Tool (EUROCON) · doi:10.1109/eurcon.2009.5167619 · Cited by 5
Self-citation
Cited by
Wearable Sensors for Remote Health Monitoring
Majumder, S., Mondal, T., & Deen, M. (2017) · Sensors · doi:10.3390/s17010130 · Cited by 1,375
Rupp, R., Rohm, M., Schneiders, M., Kreilinger, A., & Muller-Putz, G. R. (2015) · Proceedings of the IEEE · doi:10.1109/jproc.2015.2395253 · Cited by 84
“This may be achieved by the use of textile, gelless electrodes and multipad electrodes, which dynamically compensate the negative effects on grasp patterns caused by soft tissue shifts during forearm rotation [30].”
Background
Metadata
- Authors
- Malešević, N. M., Maneski, L. Z., Ilić, V., Jorgovanović, N., Bijelić, G., Keller, T., & Popović, D. B.
- Venue
- Journal of NeuroEngineering and Rehabilitation
- Published
- 2012
- Volume
- 9
- Issue
- 1
- Pages
- 66
- ISSN
- 1743-0003 (ISSN-L)
- OpenAlex
- W2115621971
- Cited by
- 178
- References
- 29
- FWCI
- 11.46
- Type
- journal article
- Language
- en
- Open access
- gold
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.