A high confidence, manually validated human blood plasma protein reference set
Open accessThe DOI matches its Crossref record; 24 of the 24 references it cites were found in a registry or an index.
Abstract
Background: The immense diagnostic potential of human plasma has prompted great interest and effort in cataloging its contents, exemplified by the Human Proteome Organization (HUPO) Plasma Proteome Project (PPP) pilot project. Due to challenges in obtaining a reliable blood plasma protein list, HUPO later re-analysed their own original dataset with a more stringent statistical treatment that resulted in a much reduced list of high confidence (at least 95%) proteins compared with their original findings. In order to facilitate the discovery of novel biomarkers in the future and to realize the full diagnostic potential of blood plasma, we feel that there is still a need for an ultra-high confidence reference list (at least 99% confidence) of blood plasma proteins. Methods: To address the complexity and dynamic protein concentration range of the plasma proteome, we employed a linear ion-trap-Fourier transform (LTQ-FT) and a linear ion trap-Orbitrap (LTQ-Orbitrap) for mass spectrometry (MS) analysis. Both instruments allow the measurement of peptide masses in the low ppm range. Furthermore, we employed a statistical score that allows database peptide identification searching using the products of two consecutive stages of tandem mass spectrometry (MS3). The combination of MS3 with very high mass accuracy in the parent peptide allows peptide identification with orders of magnitude more confidence than that typically achieved. Results: Herein we established a high confidence set of 697 blood plasma proteins and achieved a high 'average sequence coverage' of more than 14 peptides per protein and a median of 6 peptides per protein. All proteins annotated as belonging to the immunoglobulin family as well as all hypothetical proteins whose peptides completely matched immunoglobulin sequences were excluded from this protein list. We also compared the results of using two high-end MS instruments as well as the use of various peptide and protein separation approaches. Furthermore, we characterized the plasma proteins using cellular localization information, as well as comparing our list of proteins to data from other sources, including the HUPO PPP dataset. Conclusion: Superior instrumentation combined with rigorous validation criteria gave rise to a set of 697 plasma proteins in which we have very high confidence, demonstrated by an exceptionally low false peptide identification rate of 0.29%.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Gapped BLAST and PSI-BLAST: a new generation of protein database search programs
Altschul, S. (1997) · Nucleic Acids Research · doi:10.1093/nar/25.17.3389 · Cited by 73,302 · cited 5×
“All BLAST [15] and all alignments with 90% or higher identity were again manually checked for redundancy using a ClustalW alignment and our peptide mapping software.”
InfluentialPeng, J., Elias, J. E., Thoreen, C. C., Licklider, L. J., & Gygi, S. P. (2003) · Journal of Proteome Research · doi:10.1021/pr025556v · Cited by 1,647 · cited 1×
“This number was then converted to a percentage [11,12].”
Olsen, J. V., de Godoy, L. M. F., Li, G., Macek, B., Mortensen, P., Pesch, R., Makarov, A., Lange, O., Horning, S., & Mann, M. (2005) · Molecular & Cellular Proteomics · doi:10.1074/mcp.t500030-mcp200 · Cited by 1,510 · cited 1×
“The latest hybrid mass spectrometer, the LTQ-Orbitrap, has been put through the acid test [30,31] and is proving itself as a very effective, high sensitivity mass spectrometer, requiring less maintenance and being less expensive than the LTQ-FTICR.”
Self-citationAnderson, N. L., Polanski, M., Pieper, R., Gatlin, T., Tirumalai, R. S., Conrads, T. P., Veenstra, T. D., Adkins, J. N., Pounds, J. G., Fagan, R., et al. (2004) · Molecular & Cellular Proteomics · doi:10.1074/mcp.m300127-mcp200 · Cited by 1,006
Toward a Human Blood Serum Proteome
Adkins, J. N., Varnum, S. M., Auberry, K. J., Moore, R. J., Angell, N. H., Smith, R. D., Springer, D. L., & Pounds, J. G. (2002) · Molecular & Cellular Proteomics · doi:10.1074/mcp.m200066-mcp200 · Cited by 793 · cited 1×
“An estimated 10,000 proteins reside in the remaining 1% of the plasma protein mass [18].”
Omenn, G. S., States, D. J., Adamski, M., Blackwell, T. W., Menon, R., Hermjakob, H., Apweiler, R., Haab, B. B., Simpson, R. J., Eddes, J. S., et al. (2005) · PROTEOMICS · doi:10.1002/pmic.200500358 · Cited by 787 · cited 5×
“HUPO project [3-5], the possible determination of posttranslational modifications of plasma proteins such as protein phosphorylation was mentioned as an important issue for the comprehensive analysis of the protein constituents of human plasma as well as the identification of biomarkers.”
InfluentialAdachi, J., Kumar, C., Zhang, Y., Olsen, J. V., & Mann, M. (2006) · Genome Biology · doi:10.1186/gb-2006-7-9-r80 · Cited by 654 · cited 1×
“Further validation criteria were applied as previously described [13,14] and as defined by Mascot peptide identification/assignment software (Matrix Science, London, UK).”
Self-citationA Mammalian Organelle Map by Protein Correlation Profiling
Foster, L. J., de Hoog, C. L., Zhang, Y., Zhang, Y., Xie, X., Mootha, V. K., & Mann, M. (2006) · Cell · doi:10.1016/j.cell.2006.03.022 · Cited by 576 · cited 1×
“This number was then converted to a percentage [11,12].”
Self-citationPieper, R., Gatlin, C. L., Makusky, A. J., Russo, P. S., Schatz, C. R., Miller, S. S., Su, Q., McGrath, A. M., Estock, M. A., Parmar, P. P., et al. (2003) · PROTEOMICS · doi:10.1002/pmic.200300449 · Cited by 518 · cited 1×
“The combination of 2D-gel electrophoresis, removal of the most abundant serum proteins with immunoaffinity chromatography, and sequential anion-exchange and size-exclusion chromatography, and subsequent MALDI-TOF as well as online electrospray ion trap mass spectrometry, increased the number of distinct plasma protein…”
Vascular Protection: Superoxide Dismutase Isoforms in the Vessel Wall
Faraci, F. M., & Didion, S. P. (2004) · Arteriosclerosis, Thrombosis, and Vascular Biology · doi:10.1161/01.atv.0000133604.20182.cf · Cited by 457 · cited 1×
“SOD-1 is localized in the cytosol, SOD-2 in mitochondria, and SOD-3 is extracellular, and in addition to their unique subcellular localization, all three isoforms have major and distinctive responsibilities in the response process of vascular cells to both acute and chronic oxidative stress [29].”
Large-scale and high-confidence proteomic analysis of human seminal plasma
Pilch, B., & Mann, M. (2006) · Genome Biology · doi:10.1186/gb-2006-7-5-r40 · Cited by 370 · cited 1×
“Further validation criteria were applied as previously described [13,14] and as defined by Mascot peptide identification/assignment software (Matrix Science, London, UK).”
Self-citationStates, D. J., Omenn, G. S., Blackwell, T. W., Fermin, D., Eng, J., Speicher, D. W., & Hanash, S. M. (2006) · Nature Biotechnology · doi:10.1038/nbt1183 · Cited by 325 · cited 2×
“HUPO project [3-5], the possible determination of posttranslational modifications of plasma proteins such as protein phosphorylation was mentioned as an important issue for the comprehensive analysis of the protein constituents of human plasma as well as the identification of biomarkers.”
Olsen, J. V., & Mann, M. (2004) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.0405549101 · Cited by 313 · cited 1×
“MS3 spectra were automatically scored using MSQuant software [7] according to an algorithm that assigns MS3 spectra to peptide fragment sequences [8].”
Self-citationØstergaard, M., Rasmussen, H. H., Nielsen, H. V., Vorum, H., Orntoft, T. F., Wolf, H., & Celis, J. E. (1997) · PubMed · Cited by 206
Performance of a Linear Ion Trap-Orbitrap Hybrid for Peptide Analysis
Yates, J. R., Cociorva, D., Liao, L., & Zabrouskov, V. (2006) · Analytical Chemistry · doi:10.1021/ac0514624 · Cited by 175 · cited 1×
“The latest hybrid mass spectrometer, the LTQ-Orbitrap, has been put through the acid test [30,31] and is proving itself as a very effective, high sensitivity mass spectrometer, requiring less maintenance and being less expensive than the LTQ-FTICR.”
Omenn, G. S. (2004) · PROTEOMICS · doi:10.1002/pmic.200300686 · Cited by 136 · cited 2×
“HUPO project [3-5], the possible determination of posttranslational modifications of plasma proteins such as protein phosphorylation was mentioned as an important issue for the comprehensive analysis of the protein constituents of human plasma as well as the identification of biomarkers.”
Plasma protein map: An update by microsequencing
Hughes, G. J., Frutiger, S., Paquet, N., Ravier, F., Pasquali, C., Sanchez, J., James, R., Tissot, J., Bjellqvist, B., & Hochstrasser, D. F. (1992) · Electrophoresis · doi:10.1002/elps.11501301150 · Cited by 136
Ruscetti, F. W., Akel, S. M., & Bartelmez, S. H. (2005) · Oncogene · doi:10.1038/sj.onc.1208921 · Cited by 131 · cited 1×
“TGFbeta1, -beta2, and -beta3 are isoforms that share high sequence identity and play crucial and only partially overlapping roles in hematopoiesis [27], development, tumor suppression, and wound healing [28].”
Analysis of the human serum proteome
Chan, K. C., Lucas, D. A., Hise, D., Schaefer, C. F., Xiao, Z., Janini, G. M., Buetow, K. H., Issaq, H. J., Veenstra, T. D., & Conrads, T. P. (2004) · Clinical Proteomics · doi:10.1385/cp:1:2:101 · Cited by 114 · cited 2×
“[21] subjected their 1444 proteins to a gene ontology classification as well, finding a distribution of 40.”
Heller, M., Michel, P. E., Morier, P., Crettaz, D., Wenz, C., Tissot, J., Reymond, F., & Rossier, J. S. (2005) · ELECTROPHORESIS · doi:10.1002/elps.200410106 · Cited by 113 · cited 1×
“Since the immuno-depletion column employed removes from approximately 65% to 85% of the total plasma protein (Agilent, personal communication; [20]), the amount of protein loaded in the 09_OGE_6_depl_sample was correspondingly reduced to 650 ug to compensate for the loading of the non-depleted 1800 ug from 08_OGE.”
Crescenzo, G. D., Hinck, C. S., Shu, Z., Zúñiga, J. E., Yang, J., Tang, Y., Baardsnes, J., Mendoza, V., Sun, L., López‐Casillas, F., et al. (2005) · Journal of Molecular Biology · doi:10.1016/j.jmb.2005.10.022 · Cited by 101 · cited 1×
“TGFbeta1, -beta2, and -beta3 are isoforms that share high sequence identity and play crucial and only partially overlapping roles in hematopoiesis [27], development, tumor suppression, and wound healing [ 28 ].”
The Human Factor H-related Protein 4 (FHR-4)
Skerka, C., Hellwage, J., Weber, W., Tilkorn, A., Buck, F., Marti, T., Kampen, E., Beisiegel, U., & Zipfel, P. F. (1997) · Journal of Biological Chemistry · doi:10.1074/jbc.272.9.5627 · Cited by 74 · cited 1×
“5 kDa, is expressed in the liver and is secreted into the plasma where it was found to be associated with lipoproteins [16] [UniProtKB/Swiss-Prot entry Q92496].”
Ontogeny of Proteolytic Immunity
Planque, S. A., Bangale, Y. A., Song, X., Karle, S., Taguchi, H., Poindexter, B. J., Bick, R. J., Edmundson, A. B., Nishiyama, Y., & Paul, S. (2004) · Journal of Biological Chemistry · doi:10.1074/jbc.m312152200 · Cited by 61
Data management and preliminary data analysis in the pilot phase of the HUPO Plasma Proteome Project
Adamski, M., Blackwell, T. W., Menon, R., Martens, L., Hermjakob, H., Taylor, C. F., Omenn, G. S., & States, D. J. (2005) · PROTEOMICS · doi:10.1002/pmic.200500186 · Cited by 57 · cited 1×
“[22] employed a Poisson model to assess a confidence value for protein identifications that they then applied to the HUPO PPP data set.”
Cited by
Proteomics by Mass Spectrometry: Approaches, Advances, and Applications
Yates, J. R., Ruse, C. I., & Nakorchevsky, A. (2009) · Annual Review of Biomedical Engineering · doi:10.1146/annurev-bioeng-061008-124934 · Cited by 1,078
“Some of the recent applications of the LTQ-Orbitrap highlight the benefits of high mass accuracy: It improves quantification of low-abundance peptides with S/N ratio of 10 (60), it aids in profiling very complex biological samples such as human plasma (61), and it furthers identification of proteins from the limited s…”
Platelet-Rich Plasma: A Milieu of Bioactive Factors
Boswell, S. G., Cole, B. J., Sundman, E. A., Karas, V., & Fortier, L. A. (2012) · Arthroscopy: The Journal of Arthroscopic & Related Surgery · doi:10.1016/j.arthro.2011.10.018 · Cited by 613
The Clinical Plasma Proteome: A Survey of Clinical Assays for Proteins in Plasma and Serum
Anderson, N. L. (2010) · Clinical Chemistry · doi:10.1373/clinchem.2009.126706 · Cited by 562
A High-Confidence Human Plasma Proteome Reference Set with Estimated Concentrations in PeptideAtlas
Farrah, T., Deutsch, E. W., Omenn, G. S., Campbell, D. S., Sun, Z., Bletz, J. A., Mallick, P., Katz, J. E., Malmström, J., Ossola, R., et al. (2011) · Molecular & Cellular Proteomics · doi:10.1074/mcp.m110.006353 · Cited by 451
Comparative Human Salivary and Plasma Proteomes
Loo, J. A., Yan, W., Ramachandran, P., & Wong, D. T. (2010) · Journal of Dental Research · doi:10.1177/0022034510380414 · Cited by 444
Metadata
- Authors
- Schenk, S., Schoenhals, G. J., de Souza, G., & Mann, M.
- Venue
- BMC Medical Genomics
- Published
- 2008-09-15
- Volume
- 1
- Issue
- 1
- Pages
- 41-41
- ISSN
- 1755-8794 (ISSN-L)
- OpenAlex
- W2043956496
- Cited by
- 181
- References
- 24
- FWCI
- 7.06
- Type
- journal article
- Language
- en
- Open access
- gold
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.