Regional variations in transepidermal water loss, eccrine sweat gland density, sweat secretion rates and electrolyte composition in resting and exercising humans
Open accessThe DOI matches its Crossref record; 259 of the 260 references it cites were found in a registry or an index.
Abstract
Literature from the past 168 years has been filtered to provide a unified summary of the regional distribution of cutaneous water and electrolyte losses. The former occurs via transepidermal water vapour diffusion and secretion from the eccrine sweat glands. Daily insensible water losses for a standardised individual (surface area 1.8 m2) will be 0.6-2.3 L, with the hands (80-160 g.h-1) and feet (50-150 g.h-1) losing the most, the head and neck losing intermediate amounts (40-75 g.h-1) and all remaining sites losing 15-60 g.h-1. Whilst sweat gland densities vary widely across the skin surface, this same individual would possess some 2.03 million functional glands, with the highest density on the volar surfaces of the fingers (530 glands.cm-2) and the lowest on the upper lip (16 glands.cm-2). During passive heating that results in a resting whole-body sweat rate of approximately 0.4 L.min-1, the forehead (0.99 mg.cm-2.min-1), dorsal fingers (0.62 mg.cm-2.min-1) and upper back (0.59 mg.cm-2.min-1) would display the highest sweat flows, whilst the medial thighs and anterior legs will secrete the least (both 0.12 mg.cm-2.min-1). Since sweat glands selectively reabsorb electrolytes, the sodium and chloride composition of discharged sweat varies with secretion rate. Across whole-body sweat rates from 0.72 to 3.65 mg.cm-2.min-1, sodium losses of 26.5-49.7 mmol.L-1 could be expected, with the corresponding chloride loss being 26.8-36.7 mmol.L-1. Nevertheless, there can be threefold differences in electrolyte losses across skin regions. When exercising in the heat, local sweat rates increase dramatically, with regional glandular flows becoming more homogeneous. However, intra-regional evaporative potential remains proportional to each local surface area. Thus, there is little evidence that regional sudomotor variations reflect an hierarchical distribution of sweating either at rest or during exercise.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Figures
![Figure 1 Regional variations in transepidermal water loss. Data were extracted from four studies: (A) Galeotti and Macri [42]. (B) Ikeuchi and Kuno [43]. (C) Burch and Sodeman [44]. (D) Park and Tamura [45]. Data are reported in identical units and arranged in descending order. To highlight differences among sites within each study, two ordinate scales have been used. Nine sites from Park and Tamura [45] have been excluded for simplicity, leaving only the sites in common with the other reports.](https://figures.cochat.ai/paper-figures/39e827f1881642bf9854235178b27a44/regional-variations-in-transepidermal-water-loss-eccrine-sweat-gland-density-figure-1.jpg)
![Figure 2 The distribution of physiologically active, eccrine sweat glands in humans. Data are means (with 95% confidence intervals) derived across 31 studies, with an average sample size of 23 individuals per data set. The numbers above each bar indicate data sets used for that site, with the site-specific sample sizes in parenthesis (B). Means were computed as follows: regional density = ((N1 × density1) + (N2 × density2) + … (Ni × densityi)) / NTotal (where N is the sample size and subscript numerals refer to separate studies). (A) shows all sites investigated. These data were subsequently grouped into 14 larger regions (B). The active sweat glands for one region (axilla) have not been investigated, so this value was taken to be 90% of that reported in Table 1. Sources: Clark and Lhamon [60], Ogata [63], Randall [64], Thompson [65], Willis et al. [66], Roberts et al. [78], Sato and Dobson [85], Inoue et al. [86], Kondo et al. [87], Peter and Wyndham [88], Buono [89], Gibson and Shelley [90], MacKinnon [91] (with the original calculation error corrected), Collins et al., [92], Hellon and Lind [93], Silver et al. [94], Ojikutu [95], Sargent and Weinman [96], Juniper and Dykman [97], Toda [98], Bar-Or et al. [99], Knip [100], Knip [101], Schaefer et al. [102], Catania et al. [103], Behm et al. [104], Inoue et al. [105], Kondo et al. [106], Inoue et al. [107], Welch et al. [108] and Madeira et al. [109].](https://figures.cochat.ai/paper-figures/497acfb8470d412491775e833a51f3a9/regional-variations-in-transepidermal-water-loss-eccrine-sweat-gland-density-figure-2.jpg)

![Figure 4 Total cutaneous water loss and sweat gland outputs in resting, passively heated individuals. (A) Regional variations in total cutaneous water loss (descending order) and (B) sweat gland output (ordered as in A). (A) is a summation of transepidermal water loss (averaged from Figure 1: dorsal foot was assumed to equal the dorsal hand) and thermoregulatory sweating. Sweat data are means (with 95% confidence intervals across studies) derived from 17 studies (191 subjects: numbers are data sets used for each site), with an average sweat rate across all sites and studies of 0.36 mg.cm−2.min−1. For simplicity, all anterior surfaces of the head were included within the face. For the limbs, data from all surfaces were combined, while the hands and feet were separated according to their dorsal and volar surfaces, with corresponding data obtained from the fingers and toes included within those surfaces. Data for the buttocks came from only two studies with considerable between-study variability and should be treated cautiously. Site-specific sweat rates were computed as follows: regional sweating = ((N1 × SR1) + (N2 × SR2) + … (Ni × SRi)) ∕ NTotal (where N is the sample size, SR is the sweat rate and subscript numerals refer to separate studies). (B) shows variations in sweat gland output, derived by combining data from Figures 2B and 4A. Sources: Machado-Moreira and Taylor [20], Machado-Moreira et al. [21], Ikeuchi and Kuno [43], Burch and Sodeman [44], Park and Tamura [45], Taylor et al. [61], Machado-Moreira et al. [62], Inoue et al. [86], Smith et al. [194], Hertzman [207], Hertzman et al. [213], Machado-Moreira et al. [224], Machado-Moreira et al. [225], Cotter [226], Gordon [227] and Machado-Moreira [228].](https://figures.cochat.ai/paper-figures/4568a62c14be4e0aab466d086e5f99b5/regional-variations-in-transepidermal-water-loss-eccrine-sweat-gland-density-figure-4.jpg)
![Figure 5 Total cutaneous water loss and sweat gland output during dynamic and static exercise. (A) Regional variations in total cutaneous water loss (descending order) and (B) sweat gland output (ordered as in A). (A) is a summation of transepidermal water loss (averaged from Figure 1: dorsal foot was assumed to equal the dorsal hand) and thermal and non-thermal sweating. Data are means (with 95% confidence intervals across studies) derived from 20 studies (214 subjects: numbers are data sets used for each site), with an average sweat rate across all sites and studies of 0.89 mg.cm−2.min−1. For simplicity, all anterior surfaces of the head were included within the face. For the limbs, data from all surfaces were combined, while the hands and feet were separated according to their dorsal and volar surfaces, with data obtained from the fingers and toes included within those surfaces. Data for the buttocks came from only one study. Site-specific sweat rates were computed as follows: regional sweating = ((N1 × SR1) + (N2 × SR2) + … (Ni × SRi)) ∕ NTotal (where N is the sample size, SR is the sweat rate and subscript numerals refer to separate studies). (B) shows variations in sweat gland output, derived by combining data from Figures 2B and 5A. Sources: Taylor et al. [61], Machado-Moreira et al. [62], Sato and Dobson [85], Patterson et al. [156], Weiner [164], Patterson et al. [191], Havenith et al. [192], Smith et al. [194], Takano et al. [208], Kondo et al. [87], Smith and Havenith [233], Machado-Moreira et al. [224], Machado-Moreira et al. [225], Gordon [227], Höfler [234], Ayling [235], Cabanac and Brinnel [236], Libert et al. [237], Cotter et al. [238] and Cotter et al. [239].](https://figures.cochat.ai/paper-figures/1c173e784c2b477b95b5a9c4293a3904/regional-variations-in-transepidermal-water-loss-eccrine-sweat-gland-density-figure-5.jpg)

![Figure 7 Inter- and intra-regional distribution of steady-state thermal sweating (ventilated capsules) for resting individuals. Participants (N = 49) were seated (air temperature 36°C, 60% relative humidity) and wore a heated, water-perfusion suit (40°C–46°C). Data are means with standard deviations extracted from five studies undertaken within the authors' laboratory (sweat capsules (capacitance hygrometry)). Sources: Machado-Moreira et al. [62], Smith et al. [194], Machado-Moreira et al. [224], Machado-Moreira et al. [225] and Machado-Moreira [228].](https://figures.cochat.ai/paper-figures/8f1b3af6887b4f0d81fbb835dc6cac1f/regional-variations-in-transepidermal-water-loss-eccrine-sweat-gland-density-figure-7.jpg)
![Figure 8 Inter- and intra-regional distribution of steady-state sweating during exercise. Data are presented in two forms: (A) Mean sweat rates (closed circles: ventilated capsules) with standard deviations extracted from six studies undertaken in the authors' laboratory (N = 46, cycling: air temperature 36°C, 60% relative humidity: sweat capsules (capacitance hygrometry)). Subjects wore a heated, water-perfusion suit (40°C–46°C). Sources: Taylor et al. [61], Machado-Moreira et al. [62], Smith et al. [194], Machado-Moreira et al. [224], Machado-Moreira et al. [225] and Machado-Moreira [228]. (B) For comparative purposes, averages extracted from the literature for exercise (triangles) are provided (sources identified in Figure 5). Data reported by Smith and Havenith [233] (second exercise intensity) are also provided (open circles).](https://figures.cochat.ai/paper-figures/19dd0d469cdf4a50a86bcb2c7f69343c/regional-variations-in-transepidermal-water-loss-eccrine-sweat-gland-density-figure-8.jpg)
![Figure 9 Regional variations in sweat sodium, chloride and potassium concentrations. Data were obtained from 13 papers that reported both electrolyte concentrations and sweat rates, or information that permitted derivation of the latter. These sweat rate ranges and sample sizes for each site are provided in Table 5. Data are means with 95% confidence intervals across studies. Site-specific sweat compositions were computed as follows: regional composition = ((N1 × X1) + (N2 × X2) + … (Ni × Xi)) ∕ NTotal (where N is the sample size, X is the electrolyte composition and subscript numerals refer to separate studies). Sources: Sato et al. [79], Patterson et al. [191], Allan and Wilson [246], van den Heuvel et al. [248], Yousef and Dill [251], Hayden et al. [255], Collins [256], Locke et al. [257], Emrich et al. [258], Costa et al. [259], Cage et al. [260], Boisvert et al. [261], Fukumoto et al. [262] and Saat et al. [263].](https://figures.cochat.ai/paper-figures/b6ae458e11ab4f6c92ab4809fe9a14cf/regional-variations-in-transepidermal-water-loss-eccrine-sweat-gland-density-figure-9.jpg)
![Figure 10 A quadrant diagram for estimating fluid and sodium replacement rates. This prediction uses heart rates obtained during steady-state cycling in the heat (36°C, 50% relative humidity). Data were collected from six, fully-hydrated and unacclimatised females [268]. Regressions show 95% confidence intervals. Commencing from position 1, enter the quadrant to successively approximate the oxygen consumption (position 2), core temperature (position 3) and sweat rate (position 4) that would obtain for the measured heart rate. Predictions of sodium (position 5) and fluid replacement rates (position 6) to sustain body-fluid and electrolyte homeostasis can then be approximated.](https://figures.cochat.ai/paper-figures/0657d9e0de4642888321338c55fc8299/regional-variations-in-transepidermal-water-loss-eccrine-sweat-gland-density-figure-10.jpg)
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
The cited source doesn’t support the claim as written.
In the citing paper
“For instance, sweat secretion rates can be lower than 10 nL min−1 cm−2 at low secretion sites such as arm and leg, and can reach on the order of 100 nL min−1 cm−2 at high secretion areas like the palm and foot29,30.”
From A wearable patch for continuous analysis of thermoregulatory sweat at rest (2021) · cites this paper as [29]
Checked by a reasoning model — may be wrong.
Experimental — accuracy not yet measuredThe cited source doesn’t support the claim as written.
In the citing paper
“The results agree with the literatures which showed that palm and fingers have the highest secretion rate29.”
From A wearable patch for continuous analysis of thermoregulatory sweat at rest (2021) · cites this paper as [29]
Checked by a reasoning model — may be wrong.
Experimental — accuracy not yet measuredThe source backs part of the claim, not all of it — or backs it for a different population, condition or comparison.
In the citing paper
“Some studies report sweat [K+] values with a slightly broader range (e.g., ~ 2 to 8 mmol/L) than blood plasma”
From Physiological mechanisms determining eccrine sweat composition (2020) · cites this paper as Taylor and Machado-Moreira 2013
Experimental — accuracy not yet measuredThe source backs part of the claim, not all of it — or backs it for a different population, condition or comparison.
In the citing paper
“This is especially relevant in athletics, where proper fluid replacement during practice and competition is critical for ensuring physical and mental well-being (43, 44).”
From Regional and correlative sweat analysis using high-throughput microfluidic sensing patches toward decoding sweat (2019) · cites this paper as [44]
Experimental — accuracy not yet measuredThe source backs part of the claim, not all of it — or backs it for a different population, condition or comparison.
In the citing paper
“Maintaining fluid/electrolyte balance is essential for healthy vital functions.”
From Regional and correlative sweat analysis using high-throughput microfluidic sensing patches toward decoding sweat (2019) · cites this paper as [44]
Experimental — accuracy not yet measured
8 more claims about this paper
Create a free account to see every claim other papers make about this one.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
(1992) · Applied Ergonomics · doi:10.1016/0003-6870(92)90318-p · Cited by 5,737
Åstrand, P. O., & Ryhming, I. (1954) · Journal of Applied Physiology · doi:10.1152/jappl.1954.7.2.218 · Cited by 1,558 · cited 1×
“exercise-induced increments in heart rate [265] and that”
BackgroundScheuplein, R. J., & Blank, I. H. (1971) · Physiological Reviews · doi:10.1152/physrev.1971.51.4.702 · Cited by 1,398 · cited 3×
“Indeed, the steady-state water flux through the skin from the abdomen is about 10% of that observed from the plantar surface of the foot and 30% of that from the palm [27].”
BackgroundInfluentialHuman biology: A guide to field methods;
Weiner, J. S., & Lourie, J. A. (1969) · Medical Entomology and Zoology · Cited by 981
Advances in Comparative and Environmental Physiology: Volume 7
Houlihan, D. F., Livingstone, D. R., & Lee, R. F. (1991) · Advances in Comparative and Environmental Physiology · doi:10.1007/978-3-642-75897-3 · Cited by 738
Biology of sweat glands and their disorders. I. Normal sweat gland function
Sato, K., Kang, W. H., Saga, K., & Sato, K. T. (1989) · Journal of the American Academy of Dermatology · doi:10.1016/s0190-9622(89)70063-3 · Cited by 717 · cited 2×
“A discontinuous layer of myoepithelial cells separates the epithelial cells from the basement membrane [9,53,55].”
BackgroundGeneral Characteristics of Sympathetic Activity in Human Skin Nerves
Hagbarth, K. ‐., Hallin, R. G., Hongell, A., Torebjörk, H. E., & Wallin, B. G. (1972) · Acta Physiologica Scandinavica · doi:10.1111/j.1748-1716.1972.tb05167.x · Cited by 688
Physiological and behavioral temperature regulation
Hardy, J. D., Gagge, A. P., & Stolwijk, J. A. J. (1970) · Thomas eBooks · Cited by 668
Malaparte, C. (1988) · Cited by 601
Esophageal, rectal, and muscle temperature during exercise
Saltin, B., & Hermansen, L. (1966) · Journal of Applied Physiology · doi:10.1152/jappl.1966.21.6.1757 · Cited by 557 · cited 1×
“For instance, it is well known that oxygen consumption increases linearly with exercise-induced increments in heart rate [265] and that body core temperature is intrinsically linked with oxygen consumption [266].”
Background
Research works printed but not linked: 27
- Kuno Y: Human Perspiration. 1956, Springfield: C.C. Thomas
- Quincy J: Medicina Statica: Being the Aphorisms of Sanctorius. 1712, London: Printed for William Newton
- Wendt A: Über die menschliche Epidermis. Müller Arch. 1834, 278-291.
- Krause KFT: Handwörterbuch der Physiologie. Edited by: Braunschweig WR. 1844, Germany: F. Vieweg and Sohn, 108-186. Die Haut, 2,
- Ranvier L-A: Le mécanisme de la sécrétion. Schwalbe Jahresber. 1887, 16: 388-392.
- Schiefferdecker P: Die Hautdrüsen des Menschen und der Säugetiere, ihre biologische und rassenanatomische Bedeutung, sowie die Muscularis sexualis. Biol Zentralblatt. 1917, 37: 534-562.
- Sanctorius S: De statica medicina. 1614
- MacPherson RK, Newling PSB: Salt concentration and rate of evaporation of sweat. J Physiol. 1954, 123: 74P-
- Benedict FG, Benedict CG: Perspiratio insensibilis: ihr Wesen und ihre Ursachen. Biochem Ztschr. 1927, 186: 278-312.
- Buettner KJK, Odland GF: Physical factors of the skin barrier layer and water diffusion into human skin. Fed Proc. 1957, 16: 18-
- Galeotti G, Macri NM: Über die Perspiratio insensibilis unter normalen und pathologischen Bedingungen. Biochem Z. 1914, 67: 472-482.
- Ikeuchi K, Kuno Y: On the regional differences of the perspiration on the surface of the human body. J Orient Med. 1927, 7: 106-107.
- Renaut J: Dispositif anatomique et mécanisme de l'excrétion des glandes sudoripares. Ann Dermatol. 1894, 5: 1101-1104.
- Ogata K: Functional variations in human sweat glands, with remarks upon the regional differences of the amount of sweat. J Oriental Med. 1935, 23: 98-101.
- Szabo G: The number of eccrine sweat glands in human skin. Adv Biol Skin. 1962, 3: 1-5.
- Ojikutu RO: Die Rolle von Hautpigment und Schweissdrusen in der Klima-anpassung des Menschen. Homo. 1965, 16: 77-95.
- Morimoto T: Sweat secretion. The Physiology and Pharmacology of the Skin. Edited by: Jarrett A. 1978, London: Academic Press, 1611-1621.
- Eichna LW, Bean WB, Ashe WF, Nelson N: Performance in relation to environmental temperature. Bull Johns Hopkins Hosp. 1945, 76: 25-58.
- Machado-Moreira CA, Barry RJ, Vosselman MJ, Taylor NAS: Thermal and non-thermal sweating: what you see is not necessarily what you get. J Physiol Sci. 2009, 59 (Suppl. 1): 167-
- Féré C: Note sur des modifications de la résistance électrique sous l'influence des excitations sensorialles et des emotions. CR Séances Soc Biol Fil. 1888, 5: 217-219.
- Yen TJ: A new method for the measurement of the secretion of a single sweat gland. Med J Southern Manchuria. 1924, 12: 507-
- Ichihashi T: Method of observing sweat drops on the skin covered with oil, and several observations with this method. J Orient Med. 1936, 25: 107-108.
- Werner J, Graener R, Heising M, Tutughamiarsa TB: A microprocessor-supported device for the measurement of human sweat rate. Med Biol Engin Comp. 1985, 23: 1037-1038.
- Oehler J: Über die Hauttemperatur der gesunden Menschen. Deutsches Arch f klin Med. 1904, 80: 245-262.
- Takahara K: Observations on the discharge of sweat from a single sweat gland. J Oriental Med. 1936, 24: 4-
- van Beaumont W, Bullard RW, Banerjee MR: Observations on human sweating by resistance hygrometry. Dermatol Digest. 1966, 75-87.
- Gordon CJ: Non-thermoregulatory factors in humans during exercise and rest: influences on thermoeffector function. 2010, PhD thesis. University of Wollongong, Department of Biomedical Science
Cited by
Items 101–200 of 509
Self-Testing of Ketone Bodies, along with Glucose, Using Touch-Based Sweat Analysis
Moon, J., Caño, R. D., Moonla, C., Sakdaphetsiri, K., Saha, T., Mendes, L. F., Yin, L., Chang, A., Seker, S., & Wang, J. (2022) · ACS Sensors · doi:10.1021/acssensors.2c02369 · Cited by 65
Sweat as a source of non-invasive biomarkers for clinical diagnosis: An overview
Zhang, Z., Li, Z., Wei, K., Cao, Z. C., Zhu, Z., & Chen, R. (2024) · Talanta · doi:10.1016/j.talanta.2024.125865 · Cited by 69
Meade, R. D., Notley, S. R., Kirby, N. V., & Kenny, G. P. (2024) · The Lancet Planetary Health · doi:10.1016/s2542-5196(24)00030-5 · Cited by 75
“20 The high latent heat of vaporisation of sweat (2426 J/g), 17 alongside maximal sweat rates of 2 L/h or more, 21 make evaporative heat loss the most powerful autonomic cooling mechanism in humans.”
3D-Printed Flexible Microfluidic Health Monitor for In Situ Sweat Analysis and Biomarker Detection
Chen, C., Fu, Y., Sparks, S. S., Lyu, Z., Pradhan, A., Ding, S., Boddeti, N., Liu, Y., Lin, Y., Du, D., et al. (2024) · ACS Sensors · doi:10.1021/acssensors.4c00528 · Cited by 67
Patterson, M. J., Stocks, J. M., & Taylor, N. A. S. (2014) · Acta Physiologica · doi:10.1111/apha.12214 · Cited by 65
“Data were recorded at 1-s intervals (DAS1602; Keithley Instruments, Cleveland, OH, USA) and used to derive local sweat rates (Taylor et al. 1997).”
MethodSelf-citationLiu, S., Yang, D. S., Wang, S., Luan, H., Sekine, Y., Model, J. B., Aranyosi, A. J., Ghaffari, R., & Rogers, J. A. (2023) · EcoMat · doi:10.1002/eom2.12270 · Cited by 60
A Real-Time Wireless Sweat Rate Measurement System for Physical Activity Monitoring
Brueck, A., Iftekhar, A. T., Stannard, A. B., Yelamarthi, K., & Kaya, T. (2018) · Sensors · doi:10.3390/s18020533 · Cited by 59
“8 m2) were defined, and the active sweat gland density for the forearm was given as 104 glands/cm2 [14].”
BackgroundMethodInfluentialJain, V., Ochoa, M., Jiang, H., Rahimi, R., & Ziaie, B. (2019) · Microsystems & Nanoengineering · doi:10.1038/s41378-019-0067-0 · Cited by 57
Fingerprint ridges allow primates to regulate grip
Yum, S.-M., Baek, I., Hong, D., Kim, J., Jung, K., Kim, S., Eom, K., Jang, J., Kim, S., Sattorov, M. A., et al. (2020) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.2001055117 · Cited by 62
Emerging Wearable Biosensor Technologies for Stress Monitoring and Their Real-World Applications
Wu, J., Ching, C. T., Wang, H., & Liao, L. (2022) · Biosensors · doi:10.3390/bios12121097 · Cited by 65
Wearable porous PDMS layer of high moisture permeability for skin trouble reduction
Yoon, S., Seok, M., Kim, M., & Cho, Y.-H. (2021) · Scientific Reports · doi:10.1038/s41598-020-78580-z · Cited by 60
Computational design and optimization of electro-physiological sensors
Nittala, A. S., Karrenbauer, A., Khan, A., Kraus, T., & Steimle, J. (2021) · Nature Communications · doi:10.1038/s41467-021-26442-1 · Cited by 53
“The sweat gland concentration for various other locations is reported in the literature 46,47 .”
BackgroundWearable capillary microfluidics for continuous perspiration sensing
Ma, B., Chi, J., Xu, C., Ni, Y., Zhao, C., & Liu, H. (2020) · Talanta · doi:10.1016/j.talanta.2020.120786 · Cited by 54
Computational estimation of body temperature and sweating in the aged during passive heat exposure
Hirata, A., Nomura, T., & Laakso, I. (2014) · International Journal of Thermal Sciences · doi:10.1016/j.ijthermalsci.2014.11.001 · Cited by 55
“Note that the sweating rate in the forehead is approximately adjusted on the basis of the number of active glands [34].”
BackgroundMeade, R. D., Louie, J. C., Poirier, M. P., McGinn, R. N., Fujii, N., & Kenny, G. P. (2016) · Physiological Reports · doi:10.14814/phy2.12738 · Cited by 53
Wang, S., Liu, M., Yang, X., Lu, Q., Xiong, Z., Li, L., Zheng, H., Feng, S., & Zhang, T. (2022) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2022.114351 · Cited by 52
Real-time colorimetric hydration sensor for sport activities
Zhou, Y., Han, H., Naw, H. P. P., Lammy, A. V., Goh, C. H., Boujday, S., & Steele, T. W. J. (2015) · Materials & Design · doi:10.1016/j.matdes.2015.06.078 · Cited by 51
Bennet, D., Khorsandian, Y., Pelusi, J., Mirabella, A., Pirrotte, P., & Zenhausern, F. (2021) · Clinical and Translational Medicine · doi:10.1002/ctm2.461 · Cited by 53
Ammer, K., & Ring, F. J. (2019) · doi:10.1201/9780429019982 · Cited by 55
Treefrog‐Inspired Flexible Electrode with High Permeability, Stable Adhesion, and Robust Durability
Lan, T., Tian, H., Chen, X., Li, X., Wang, C., Wang, D., Li, S., Liu, G., Zhu, X., & Shao, J. (2024) · Advanced Materials · doi:10.1002/adma.202404761 · Cited by 52
Delgado‐Povedano, M. D. M., Calderón-Santiago, M., Priego‐Capote, F., & de Castro, M. D. L. (2015) · Analytica Chimica Acta · doi:10.1016/j.aca.2015.11.048 · Cited by 48
Conformal and Disposable Antenna-Based Sensor for Non-Invasive Sweat Monitoring
Eldamak, A. R., & Fear, E. C. (2018) · Sensors · doi:10.3390/s18124088 · Cited by 51
Electrodermal activity as a proxy for sweat rate monitoring during physical and mental activities
Kim, S., Zhan, Y., Davis, N., Bellamkonda, S., Gillan, L., Hakola, E., Hiltunen, J. A., & Javey, A. (2025) · Nature Electronics · doi:10.1038/s41928-025-01365-7 · Cited by 59
“In one system, dry electrodes fabricated on thin plastic substrates are laser cut into a lace-like structure with sub-50-μm linewidths, smaller than the average size of sweat pores 23 .”
Water content of latent fingerprints – Dispelling the myth
Kent, T. (2016) · Forensic Science International · doi:10.1016/j.forsciint.2016.05.016 · Cited by 44
An All‐Fabric Droplet‐Based Energy Harvester with Topology Optimization
Liang, F., Chao, X., Yu, S., Gu, Y., Zhang, X., Wei, X., Fan, J., Tao, X., & Shou, D. (2021) · Advanced Energy Materials · doi:10.1002/aenm.202102991 · Cited by 45
Open nanofluidic films with rapid transport and no analyte exchange for ultra-low sample volumes
Twine, N. B., Norton, R. M., Brothers, M. C., Hauke, A., Gomez, E. F., & Heikenfeld, J. (2018) · Lab on a Chip · doi:10.1039/c8lc00186c · Cited by 43
Influence of exposure to summer environments on skin properties
Kim, S., Park, J. W., Yeon, Y., Han, J. Y., & Kim, E. (2019) · Journal of the European Academy of Dermatology and Venereology · doi:10.1111/jdv.15745 · Cited by 39
Methods for improving thermal tolerance in military personnel prior to deployment
Ashworth, E. T., Cotter, J. D., & Kilding, A. E. (2020) · Military Medical Research · doi:10.1186/s40779-020-00287-z · Cited by 52
Notley, S. R., Park, J., Tagami, K., Ohnishi, N., & Taylor, N. A. S. (2016) · Journal of Applied Physiology · doi:10.1152/japplphysiol.00151.2016 · Cited by 44
“That discrepancy may be explained by the well known limitations of using local sweating to approximated whole-body sudomotor function (39).”
BackgroundSelf-citationA Compressed Sensing Based Decomposition of Electrodermal Activity Signals
Jain, S., Oswal, U., Xu, K. S., Eriksson, B., & Haupt, J. (2016) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2016.2632523 · Cited by 42
“Electrodermal Activity, or EDA, is typically recorded as the conductance over a person’s skin, near concentrations of sweat glands ( e.g., palm of the hand or finger tips [1]).”
BackgroundPersonal Moisture Management by Advanced Textiles and Intelligent Wearables
Shou, D., & Li, Z. (2025) · Advanced Materials · doi:10.1002/adma.202508831 · Cited by 43
Diversity and evolution of human eccrine sweat gland density
Best, A. W., Lieberman, D. E., & Kamilar, J. M. (2019) · Journal of Thermal Biology · doi:10.1016/j.jtherbio.2019.07.024 · Cited by 45
“Since Kuno (1956), several researchers (Thomson, 1953; Folk and Semken, 1991; Taylor and Machado-Moreira, 2013; Machado-Moreira and Taylor, 2017) have proposed that some proportion of human eccrine glands are wholly inactive—that is, they appear normal in structure but fail to produce sweat in response to thermal expo…”
BackgroundA Bioinspired Wireless Epidermal Photoreceptor for Artificial Skin Vision
Zhang, Y., & Tao, T. H. (2020) · Advanced Functional Materials · doi:10.1002/adfm.202000381 · Cited by 41
Ishibashi, F., Kojima, R., Kawasaki, A., Yamanaka, E., Kosaka, A., & Uetake, H. (2013) · Journal of Diabetes Investigation · doi:10.1111/jdi.12171 · Cited by 38
Amengual‐Gual, M., Ulate-Campos, A., & Loddenkemper, T. (2018) · Seizure · doi:10.1016/j.seizure.2018.09.013 · Cited by 40
Wang, S., Lafaye, C., Saubade, M., Besson, C., Margarit, J. M., Grémeaux, V., & Liu, S. (2022) · IEEE Journal of Biomedical and Health Informatics · doi:10.1109/jbhi.2022.3186150 · Cited by 37
“All sweat samples were collected using the absorbent patch technique [26] during each session.”
MethodA wearable microfluidic system for efficient sweat collection and real-time detection
Yin, Y., Tan, Z., Zhu, W., Pu, Z., Yu, H., Wang, R., & Li, D. (2024) · Talanta · doi:10.1016/j.talanta.2024.125967 · Cited by 41
Noninvasive On-Skin Biosensors for Monitoring Diabetes Mellitus
Sedighi, A., Kou, T., Huang, H., & Li, Y. (2025) · Nano-Micro Letters · doi:10.1007/s40820-025-01843-9 · Cited by 52
Brain stem representation of thermal and psychogenic sweating in humans
Farrell, M. J., Trevaks, D., Taylor, N. A. S., & McAllen, R. M. (2013) · American Journal of Physiology-Regulatory, Integrative and Comparative Physiology · doi:10.1152/ajpregu.00041.2013 · Cited by 36
Self-citationPatle, S. K., & Rotake, D. R. (2024) · Microchemical Journal · doi:10.1016/j.microc.2024.110457 · Cited by 36
Carr, A. R., Patel, Y., Neff, C. R., Charkhabi, S., Kallmyer, N. E., Angus, H. F., & Reuel, N. F. (2020) · npj Digital Medicine · doi:10.1038/s41746-020-0270-2 · Cited by 40
Carbon nanomaterials for sweat-based sensors: a review
Ehtesabi, H., & Kalji, S.-O. (2024) · Microchimica Acta · doi:10.1007/s00604-023-06162-7 · Cited by 39
“Additionally, the K concentration in sweat, which has a normal range of 1 to 24 mM, can reveal the physiological well-being of the human body [57].”
Chen, X., Gąsecka, P., Formanek, F., Galey, J.-B., & Rigneault, H. (2016) · British Journal of Dermatology · doi:10.1111/bjd.14292 · Cited by 39
Januário, W. M., Lessa, N. F., Schittine, A. J. D. O., Prata, E. R. B. D. A., Marins, J. C. B., Natali, A. J., Wanner, S. P., & Prímola‐Gomes, T. N. (2024) · Journal of Thermal Biology · doi:10.1016/j.jtherbio.2024.103907 · Cited by 39
Bio-inspired fractal textile device for rapid sweat collection and monitoring
Chen, Y.-C., Shan, S.-S., Liao, Y., & Liao, Y. (2021) · Lab on a Chip · doi:10.1039/d1lc00328c · Cited by 36
Bainbridge, P., Browning, P., Bernatchez, S. F., Blaser, C., & Hitschmann, G. (2021) · The Journal of Vascular Access · doi:10.1177/11297298211050485 · Cited by 34
Tape‐Free, Digital Wearable Band for Exercise Sweat Rate Monitoring
Dautta, M., Ayala‐Cardona, L. F., Davis, N., Aggarwal, A., Park, J., Wang, S., Gillan, L., Jansson, E., Hietala, M., Ko, H., et al. (2023) · Advanced Materials Technologies · doi:10.1002/admt.202201187 · Cited by 37
Multifunctional Wearable System for Mapping Body Temperature and Analyzing Sweat
Alam, M. S., Kim, J. K., & Choi, J. (2023) · ACS Sensors · doi:10.1021/acssensors.3c00098 · Cited by 36
Jimenez‐Perez, I., Gil-Calvo, M., Priego‐Quesada, J. I., Aparicio, I., Pérez‐Soriano, P., & de Anda, R. M. C. O. (2020) · Journal of Thermal Biology · doi:10.1016/j.jtherbio.2020.102612 · Cited by 33
Finnegan, M., Duffy, E., & Morrin, A. (2022) · Sensing and Bio-Sensing Research · doi:10.1016/j.sbsr.2022.100473 · Cited by 34
A Passive Sweat-Responsive Thermoregulatory Textile with the Largest Thermal Comfort Zone
Wang, X., Du, X., Xu, D., Wei, T., Zhang, Q., Chen, Z., Kong, D., Wei, K., Zhou, L., Zhu, B., et al. (2025) · ACS Nano · doi:10.1021/acsnano.5c03236 · Cited by 34
Wearable Humidity Sensor for Continuous Sweat Rate Monitoring
Aggarwal, A., Dautta, M., Ayala‐Cardona, L. F., Wudaru, A., & Javey, A. (2023) · Advanced Materials Technologies · doi:10.1002/admt.202300385 · Cited by 33
Kang, T. W., Lee, J., Kwon, Y., Lee, Y. J., & Yeo, W. (2024) · Advanced NanoBiomed Research · doi:10.1002/anbr.202300169 · Cited by 34
Versatile sweat bioanalysis on demand with hydrogel-programmed wearables
Chen, Y., Ma, B., Zuo, Y., Chen, G., Hao, Q., Zhao, C., & Liu, H. (2023) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2023.115412 · Cited by 35
Understanding Physical Developer (PD): Part II – Is PD targeting eccrine constituents?
de la Hunty, M., Moret, S., Chadwick, S., Lennard, C. J., Spindler, X., & Roux, C. P. (2015) · Forensic Science International · doi:10.1016/j.forsciint.2015.08.029 · Cited by 31
“An average person has more than two million functional glands on the entire surface of the body, with the highest density on the volar surfaces of the fingers, with an average of 530 glands cm 2 and a water loss rate of 80–160 g h 1 [5].”
BackgroundThermal performance trials on the habitability of private bushfire shelters: part 2
Taylor, N. A. S., & Haberley, B. J. (2014) · International Journal of Biometeorology · doi:10.1007/s00484-014-0912-7 · Cited by 30
Self-citationRao, L. T., Mandal, C. K., & Patolsky, F. (2025) · Advanced Healthcare Materials · doi:10.1002/adhm.202503096 · Cited by 45
External ears for non-invasive and stable monitoring of volatile organic compounds in human blood
Toma, K., Suzuki, S., Arakawa, T., Iwasaki, Y., & Mitsubayashi, K. (2021) · Scientific Reports · doi:10.1038/s41598-021-90146-1 · Cited by 33
Noninvasive Concept for Optical Ethanol Sensing on the Skin Surface with Camera-Based Quantification
Hair, M. E., Gerkman, R., Mathis, A. I., Halámková, L., & Halámek, J. (2019) · Analytical Chemistry · doi:10.1021/acs.analchem.9b04297 · Cited by 30
Focus Review on Nanomaterial-Based Electrochemical Sensing of Glucose for Health Applications
Tonelli, D., Gualandi, I., Scavetta, E., & Mariani, F. (2023) · Nanomaterials · doi:10.3390/nano13121883 · Cited by 30
“99 μL cm−2 min−1 [68], while the tears volume is about 7 μL [69,70].”
Overwhelming Physiological Regulation Through Personal Protection
Taylor, N. A. S. (2015) · The Journal of Strength and Conditioning Research · doi:10.1519/jsc.0000000000001030 · Cited by 29
“24), then through its passive dissipation to the ambient medium (dry heat loss), and eventually, if required, through the neural activation of evaporative cooling (52).”
BackgroundSelf-citationAdvanced Microfluidic‐Based Wearable Electrochemical Sensors for Continuous Biochemical Monitoring
Park, S., Kim, S., Lee, S.-J., Tsukruk, V. V., Park, S., & Lim, H. (2025) · Advanced Electronic Materials · doi:10.1002/aelm.202500010 · Cited by 31
Murphy, G. R., Dunstan, R. H., Macdonald, M. M., Borges, N. R., Radford, Z., Sparkes, D. L., Dascombe, B. J., & Roberts, T. K. (2019) · PLoS ONE · doi:10.1371/journal.pone.0223381 · Cited by 29
Caldwell, J. N., Matsuda‐Nakamura, M., & Taylor, N. A. S. (2015) · European Journal of Applied Physiology · doi:10.1007/s00421-015-3288-4 · Cited by 29
“These data also highlight clear regional differences in vascular control, as recently defined for sudomotor function (Taylor and Machado-Moreira 2013), with the more distal sites typically experiencing greater blood flow extremes.”
BackgroundSelf-citationA wearable sensor patch for joule-heating sweating and comfortable biofluid monitoring
Li, X., He, X., Yang, X., Tian, G., Liu, C., & Xu, T. (2024) · Sensors and Actuators B Chemical · doi:10.1016/j.snb.2024.136399 · Cited by 30
Abbasiasl, T., Mirlou, F., Istif, E., Koydemir, H. C., & Beker, L. (2022) · Sensors & Diagnostics · doi:10.1039/d2sd00032f · Cited by 28
Transepidermal water loss and stratum corneum hydration in forearm versus hand palm
MAYROVITZ, H. N. (2023) · Skin Research and Technology · doi:10.1111/srt.13218 · Cited by 27
Zhang, M., Zeng, S., Zhang, L., Li, H., Chen, L., Zhang, X., Li, X., Lin, C., Shu, S., Xie, S., et al. (2014) · Acta Histochemica · doi:10.1016/j.acthis.2014.08.010 · Cited by 28
“Sweat is derived from blood plasma and it contains mostly ater (Saga, 2002; Taylor and Machado-Moreira, 2013).”
BackgroundIncidence, severity, and impact of hyperhidrosis in people with lower-limb amputation
Hansen, C. R., Godfrey, B., Wixom, J. Q., & McFadden, M. (2015) · The Journal of Rehabilitation Research and Development · doi:10.1682/jrrd.2014.04.0108 · Cited by 27
“Sweat gland density does not appear to vary significantly from the leg region to the thigh region [28], so this finding may simply relate to the relative area of skin covered by liners and sleeves.”
BackgroundGao, Y., Xu, B., Qiu, M., Li, Z., Ahmed, T., Yang, Y., Guan, X., & Hong, F. (2024) · Advanced Functional Materials · doi:10.1002/adfm.202416577 · Cited by 35
Drug-Induced Hyperthermia Review
Horseman, M. A., Panahi, L., Udeani, G., Tenpas, A., Verduzco, R., Patel, P. H., Bazan, D. Z., Mora, A., Samuel, N. G., Mingle, A.-C., et al. (2022) · Cureus · doi:10.7759/cureus.27278 · Cited by 36
“Human skin contains approximately two million eccrine sweat glands [8].”
BackgroundShen, G., Moua, K. T. Y., Perkins, K., Johnson, D., Li, A., Curtin, P. T., Gao, W. F., & McCune, J. S. (2023) · Frontiers in Pharmacology · doi:10.3389/fphar.2023.1126981 · Cited by 26
Emerging trends in wearable glove-based sensors: A review
Tsong, J. L., Robert, R., & Khor, S. M. (2023) · Analytica Chimica Acta · doi:10.1016/j.aca.2023.341277 · Cited by 27
Willmott, A. G. B., Gibson, O. R., James, C., Hayes, M., & Maxwell, N. (2018) · Temperature · doi:10.1080/23328940.2018.1426949 · Cited by 26
“back, forearm, axilla, chest, abdomen and buttocks) [38].”
BackgroundNotley, S. R., Meade, R. D., Looney, D. P., Chapman, C. L., Potter, A. W., Fogarty, A. L., Howlader, T., Main, L. C., Friedl, K. E., & Kenny, G. P. (2025) · Applied Physiology, Nutrition, and Metabolism · doi:10.1139/apnm-2024-0395 · Cited by 33
A Janus infrared emission dual-mode super-fabric for sustainable efficient thermal management
Zhang, X., Zhang, T., Cao, Y., Jiang, Y., Chen, Y., Li, Y., Yu, D., & Wang, W. (2024) · Chemical Engineering Journal · doi:10.1016/j.cej.2024.158664 · Cited by 27
Location of cat brain stem neurons that drive sweating
Shafton, A. D., & McAllen, R. M. (2013) · American Journal of Physiology-Regulatory, Integrative and Comparative Physiology · doi:10.1152/ajpregu.00040.2013 · Cited by 25
Sheffield, Z., Paul, P., Krishnakumar, S., & Pan, D. (2024) · Advanced Science · doi:10.1002/advs.202411339 · Cited by 29
Lin, P.-H., Chang, W.-L., Sheu, S.-C., & Li, B. (2020) · iScience · doi:10.1016/j.isci.2020.101658 · Cited by 24
Percutaneous metals absorption following exposure to road dust powder
Magnano, G. C., Marussi, G., Pavoni, E., Adami, G., Filon, F. L., & Crosera, M. (2021) · Environmental Pollution · doi:10.1016/j.envpol.2021.118353 · Cited by 27
Skin‐Interfaced Bifluidic Paper‐Based Device for Quantitative Sweat Analysis
Deng, M., Li, X., Song, K., Yang, H., Wei, W., Duan, X., Ouyang, X., Cheng, H., & Wang, X. (2023) · Advanced Science · doi:10.1002/advs.202306023 · Cited by 28
Hybrid 3D Printing of a Nature‐Inspired Flexible Self‐Adhesive Biopatch for Multi‐Biosignal Sensing
Alsharif, A. A., Syed, A. M., Li, X., Alsharif, N. A., Lubineau, G., & El‐Atab, N. (2024) · Advanced Functional Materials · doi:10.1002/adfm.202406341 · Cited by 29
Huygen, L., Thys, P. M., Wollenberg, A., Gutermuth, J., & Krohn, I. K. (2024) · Annals of Dermatology · doi:10.5021/ad.23.052 · Cited by 23
Performance of Polymeric Skin Adhesives during Perspiration
Hansen, D. A., Moghaddam, S. Z., Eiler, J., Hansen, K., & Thormann, E. (2020) · ACS Applied Polymer Materials · doi:10.1021/acsapm.9b01214 · Cited by 27
Sponge-inspired MXene@CeO2 detector for ultra-sensitive detection of glucose
Jiang, S., Zhang, H., Li, Z., Chen, L., Yin, L., & Liu, X. (2023) · Materials Today Chemistry · doi:10.1016/j.mtchem.2023.101638 · Cited by 28
In vitro evaluation of skin adhesives during perspiration
Eiler, J., Hansen, D. A., Bingöl, B., Hansen, K., Heikenfeld, J. C., & Thormann, E. (2020) · International Journal of Adhesion and Adhesives · doi:10.1016/j.ijadhadh.2020.102574 · Cited by 24
New wicking measurement system to mimic human sweating phenomena with continuous microfluidic flow
Kim, H. S., Michielsen, S., & DenHartog, E. (2020) · Journal of Materials Science · doi:10.1007/s10853-020-04543-4 · Cited by 23
Analytical assessment of sodium ISFET based sensors for sweat analysis
Rovira, M., Lafaye, C., Wang, S., Fernández‐Sánchez, C., Saubade, M., Liu, S., & Jiménez‐Jorquera, C. (2023) · Sensors and Actuators B Chemical · doi:10.1016/j.snb.2023.134135 · Cited by 22
Bretagne, A., Cotot, F., Arnaud‐Roux, M., Sztucki, M., Cabane, B., & Galey, J.-B. (2017) · Soft Matter · doi:10.1039/c6sm02510b · Cited by 25
Dry Electrode Optimization for Wrist-based Electrodermal Activity Monitoring
Anusha, A. S., Preejith, S. P., Akl, T. J., Joseph, J., & Sivaprakasam, M. (2018) · IEEE International Symposium on Medical Measurements and Applications (MeMeA) · doi:10.1109/memea.2018.8438595 · Cited by 22
Knitting technology for seamless sportswear
Troynikov, O., & Watson, C. (2015) · Elsevier eBooks · doi:10.1016/b978-1-78242-229-7.00005-9 · Cited by 30
Machado-Moreira, C. A., Barry, R. J., Vosselman, M. J., Ruest, R. M., & Taylor, N. A. S. (2014) · Psychophysiology · doi:10.1111/psyp.12292 · Cited by 22
Self-citationRecent Advances in Stretchable and Permeable Electrodes for Epidermal Electronics
Li, Y., Sun, Y., Lu, Q., Lu, Y., & Kong, D. (2024) · Advanced Sensor Research · doi:10.1002/adsr.202300195 · Cited by 25
Subochev, P., Deán‐Ben, X. L., Chen, Z., Prudnikov, M., Vorobev, V. A., Kurnikov, A. A., Orlova, A., Postnikova, A. S., Kharitonov, A. V., Proyavin, M. D., et al. (2025) · Light Science & Applications · doi:10.1038/s41377-025-01894-y · Cited by 23
Ohashi, T., Gerrett, N., Shinkawa, S., Satō, T., Miyake, R., Kondo, N., & Mitsuzawa, S. (2020) · Analytical Chemistry · doi:10.1021/acs.analchem.0c03466 · Cited by 23
Moore, S., McIntosh, R. L., Iskra, S., & Wood, A. (2015) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2014.2362517 · Cited by 23
“the most recent and experimental data [48].”
Kim, M., Doh, I., Oh, E., & Cho, Y.-H. (2023) · ACS Applied Nano Materials · doi:10.1021/acsanm.3c04030 · Cited by 23
Ma, J., Li, H., Anwer, S., Umer, W., Antwi‐Afari, M. F., & Xiao, E. B. (2024) · International Journal of Occupational Safety and Ergonomics · doi:10.1080/10803548.2024.2330242 · Cited by 21
Topically Applied Therapies for the Treatment of Skin Disease: Past, Present, and Future
Brown, M. B., Williams, A., Chilcott, R. P., Brady, B., Lenn, J. D., Evans, C., Allen, L., McAuley, W. J., Beebeejaun, M., Haslinger, J., et al. (2024) · Pharmacological Reviews · doi:10.1124/pharmrev.123.000549 · Cited by 32
Kownacki, K. L., Dahl, M., Gao, C., Jakobsson, K., Linninge, C., Song, D., & Kuklane, K. (2017) · Industrial Health · doi:10.2486/indhealth.2017-0030 · Cited by 20
Metadata
- Authors
- Taylor, N. A., & Machado-Moreira, C. A.
- Affiliations
- University of Wollongong (AU)
- Corresponding author
- Taylor, Nigel AS
- ORCID
- Taylor, Nigel AS
- Venue
- Extreme Physiology & Medicine
- Published
- 2013-02-01
- Volume
- 2
- Issue
- 1
- Pages
- 4-4
- ISSN
- 2046-7648 (ISSN-L)
- PMC
- PMC3710196
- OpenAlex
- W2131490519
- Cited by
- 490
- References
- 260
- Citations by year
- 2026: 31 · 2025: 47 · 2024: 56 · 2023: 44 · 2022: 45 · 2021: 57 · 2020: 44 · 2019: 38 · 2018: 38 · 2017: 26 · 2016: 14 · 2015: 25 · 2014: 16 · 2013: 8
- FWCI
- 14.62
- Type
- journal article
- Language
- en
- Open access
- hybrid
- doi.org
- Licence
- cc-by
- creativecommons.org/licenses/by/2.0 (tdm)
- Locations
- Extreme Physiology & Medicine (publishedVersion, cc-by)
- Europe PMC (PubMed Central) (publishedVersion, cc-by)
- PubMed Central (publishedVersion, cc-by)
- PubMed (publishedVersion)
- Research Online (University of Wollongong) (submittedVersion)
- Figshare (submittedVersion)
- Funders
- Coordenação de Aperfeiçoamento de Pessoal de Nível Superior
- Ministério da Educação
- Defence Science and Technology Group
- Topics
- Health Sciences › Medicine › Physiology (medical) › Thermoregulation and physiological responses
- Health Sciences › Medicine › Physiology (medical) › Cardiovascular and exercise physiology
- Physical Sciences › Materials Science › Polymers and Plastics › Textile materials and evaluations
- Keywords
- transepidermal water loss, eccrine sweat glands, sweat gland density, insensible water loss, passive heating, exercise thermoregulation, evaporative cooling
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.