Regional variations in transepidermal water loss, eccrine sweat gland density, sweat secretion rates and electrolyte composition in resting and exercising humans
Open accessThe DOI matches its Crossref record; 259 of the 260 references it cites were found in a registry or an index.
Abstract
Literature from the past 168 years has been filtered to provide a unified summary of the regional distribution of cutaneous water and electrolyte losses. The former occurs via transepidermal water vapour diffusion and secretion from the eccrine sweat glands. Daily insensible water losses for a standardised individual (surface area 1.8 m2) will be 0.6-2.3 L, with the hands (80-160 g.h-1) and feet (50-150 g.h-1) losing the most, the head and neck losing intermediate amounts (40-75 g.h-1) and all remaining sites losing 15-60 g.h-1. Whilst sweat gland densities vary widely across the skin surface, this same individual would possess some 2.03 million functional glands, with the highest density on the volar surfaces of the fingers (530 glands.cm-2) and the lowest on the upper lip (16 glands.cm-2). During passive heating that results in a resting whole-body sweat rate of approximately 0.4 L.min-1, the forehead (0.99 mg.cm-2.min-1), dorsal fingers (0.62 mg.cm-2.min-1) and upper back (0.59 mg.cm-2.min-1) would display the highest sweat flows, whilst the medial thighs and anterior legs will secrete the least (both 0.12 mg.cm-2.min-1). Since sweat glands selectively reabsorb electrolytes, the sodium and chloride composition of discharged sweat varies with secretion rate. Across whole-body sweat rates from 0.72 to 3.65 mg.cm-2.min-1, sodium losses of 26.5-49.7 mmol.L-1 could be expected, with the corresponding chloride loss being 26.8-36.7 mmol.L-1. Nevertheless, there can be threefold differences in electrolyte losses across skin regions. When exercising in the heat, local sweat rates increase dramatically, with regional glandular flows becoming more homogeneous. However, intra-regional evaporative potential remains proportional to each local surface area. Thus, there is little evidence that regional sudomotor variations reflect an hierarchical distribution of sweating either at rest or during exercise.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Figures
![Figure 1 Regional variations in transepidermal water loss. Data were extracted from four studies: (A) Galeotti and Macri [42]. (B) Ikeuchi and Kuno [43]. (C) Burch and Sodeman [44]. (D) Park and Tamura [45]. Data are reported in identical units and arranged in descending order. To highlight differences among sites within each study, two ordinate scales have been used. Nine sites from Park and Tamura [45] have been excluded for simplicity, leaving only the sites in common with the other reports.](https://figures.cochat.ai/paper-figures/39e827f1881642bf9854235178b27a44/regional-variations-in-transepidermal-water-loss-eccrine-sweat-gland-density-figure-1.jpg)
![Figure 2 The distribution of physiologically active, eccrine sweat glands in humans. Data are means (with 95% confidence intervals) derived across 31 studies, with an average sample size of 23 individuals per data set. The numbers above each bar indicate data sets used for that site, with the site-specific sample sizes in parenthesis (B). Means were computed as follows: regional density = ((N1 × density1) + (N2 × density2) + … (Ni × densityi)) / NTotal (where N is the sample size and subscript numerals refer to separate studies). (A) shows all sites investigated. These data were subsequently grouped into 14 larger regions (B). The active sweat glands for one region (axilla) have not been investigated, so this value was taken to be 90% of that reported in Table 1. Sources: Clark and Lhamon [60], Ogata [63], Randall [64], Thompson [65], Willis et al. [66], Roberts et al. [78], Sato and Dobson [85], Inoue et al. [86], Kondo et al. [87], Peter and Wyndham [88], Buono [89], Gibson and Shelley [90], MacKinnon [91] (with the original calculation error corrected), Collins et al., [92], Hellon and Lind [93], Silver et al. [94], Ojikutu [95], Sargent and Weinman [96], Juniper and Dykman [97], Toda [98], Bar-Or et al. [99], Knip [100], Knip [101], Schaefer et al. [102], Catania et al. [103], Behm et al. [104], Inoue et al. [105], Kondo et al. [106], Inoue et al. [107], Welch et al. [108] and Madeira et al. [109].](https://figures.cochat.ai/paper-figures/497acfb8470d412491775e833a51f3a9/regional-variations-in-transepidermal-water-loss-eccrine-sweat-gland-density-figure-2.jpg)

![Figure 4 Total cutaneous water loss and sweat gland outputs in resting, passively heated individuals. (A) Regional variations in total cutaneous water loss (descending order) and (B) sweat gland output (ordered as in A). (A) is a summation of transepidermal water loss (averaged from Figure 1: dorsal foot was assumed to equal the dorsal hand) and thermoregulatory sweating. Sweat data are means (with 95% confidence intervals across studies) derived from 17 studies (191 subjects: numbers are data sets used for each site), with an average sweat rate across all sites and studies of 0.36 mg.cm−2.min−1. For simplicity, all anterior surfaces of the head were included within the face. For the limbs, data from all surfaces were combined, while the hands and feet were separated according to their dorsal and volar surfaces, with corresponding data obtained from the fingers and toes included within those surfaces. Data for the buttocks came from only two studies with considerable between-study variability and should be treated cautiously. Site-specific sweat rates were computed as follows: regional sweating = ((N1 × SR1) + (N2 × SR2) + … (Ni × SRi)) ∕ NTotal (where N is the sample size, SR is the sweat rate and subscript numerals refer to separate studies). (B) shows variations in sweat gland output, derived by combining data from Figures 2B and 4A. Sources: Machado-Moreira and Taylor [20], Machado-Moreira et al. [21], Ikeuchi and Kuno [43], Burch and Sodeman [44], Park and Tamura [45], Taylor et al. [61], Machado-Moreira et al. [62], Inoue et al. [86], Smith et al. [194], Hertzman [207], Hertzman et al. [213], Machado-Moreira et al. [224], Machado-Moreira et al. [225], Cotter [226], Gordon [227] and Machado-Moreira [228].](https://figures.cochat.ai/paper-figures/4568a62c14be4e0aab466d086e5f99b5/regional-variations-in-transepidermal-water-loss-eccrine-sweat-gland-density-figure-4.jpg)
![Figure 5 Total cutaneous water loss and sweat gland output during dynamic and static exercise. (A) Regional variations in total cutaneous water loss (descending order) and (B) sweat gland output (ordered as in A). (A) is a summation of transepidermal water loss (averaged from Figure 1: dorsal foot was assumed to equal the dorsal hand) and thermal and non-thermal sweating. Data are means (with 95% confidence intervals across studies) derived from 20 studies (214 subjects: numbers are data sets used for each site), with an average sweat rate across all sites and studies of 0.89 mg.cm−2.min−1. For simplicity, all anterior surfaces of the head were included within the face. For the limbs, data from all surfaces were combined, while the hands and feet were separated according to their dorsal and volar surfaces, with data obtained from the fingers and toes included within those surfaces. Data for the buttocks came from only one study. Site-specific sweat rates were computed as follows: regional sweating = ((N1 × SR1) + (N2 × SR2) + … (Ni × SRi)) ∕ NTotal (where N is the sample size, SR is the sweat rate and subscript numerals refer to separate studies). (B) shows variations in sweat gland output, derived by combining data from Figures 2B and 5A. Sources: Taylor et al. [61], Machado-Moreira et al. [62], Sato and Dobson [85], Patterson et al. [156], Weiner [164], Patterson et al. [191], Havenith et al. [192], Smith et al. [194], Takano et al. [208], Kondo et al. [87], Smith and Havenith [233], Machado-Moreira et al. [224], Machado-Moreira et al. [225], Gordon [227], Höfler [234], Ayling [235], Cabanac and Brinnel [236], Libert et al. [237], Cotter et al. [238] and Cotter et al. [239].](https://figures.cochat.ai/paper-figures/1c173e784c2b477b95b5a9c4293a3904/regional-variations-in-transepidermal-water-loss-eccrine-sweat-gland-density-figure-5.jpg)

![Figure 7 Inter- and intra-regional distribution of steady-state thermal sweating (ventilated capsules) for resting individuals. Participants (N = 49) were seated (air temperature 36°C, 60% relative humidity) and wore a heated, water-perfusion suit (40°C–46°C). Data are means with standard deviations extracted from five studies undertaken within the authors' laboratory (sweat capsules (capacitance hygrometry)). Sources: Machado-Moreira et al. [62], Smith et al. [194], Machado-Moreira et al. [224], Machado-Moreira et al. [225] and Machado-Moreira [228].](https://figures.cochat.ai/paper-figures/8f1b3af6887b4f0d81fbb835dc6cac1f/regional-variations-in-transepidermal-water-loss-eccrine-sweat-gland-density-figure-7.jpg)
![Figure 8 Inter- and intra-regional distribution of steady-state sweating during exercise. Data are presented in two forms: (A) Mean sweat rates (closed circles: ventilated capsules) with standard deviations extracted from six studies undertaken in the authors' laboratory (N = 46, cycling: air temperature 36°C, 60% relative humidity: sweat capsules (capacitance hygrometry)). Subjects wore a heated, water-perfusion suit (40°C–46°C). Sources: Taylor et al. [61], Machado-Moreira et al. [62], Smith et al. [194], Machado-Moreira et al. [224], Machado-Moreira et al. [225] and Machado-Moreira [228]. (B) For comparative purposes, averages extracted from the literature for exercise (triangles) are provided (sources identified in Figure 5). Data reported by Smith and Havenith [233] (second exercise intensity) are also provided (open circles).](https://figures.cochat.ai/paper-figures/19dd0d469cdf4a50a86bcb2c7f69343c/regional-variations-in-transepidermal-water-loss-eccrine-sweat-gland-density-figure-8.jpg)
![Figure 9 Regional variations in sweat sodium, chloride and potassium concentrations. Data were obtained from 13 papers that reported both electrolyte concentrations and sweat rates, or information that permitted derivation of the latter. These sweat rate ranges and sample sizes for each site are provided in Table 5. Data are means with 95% confidence intervals across studies. Site-specific sweat compositions were computed as follows: regional composition = ((N1 × X1) + (N2 × X2) + … (Ni × Xi)) ∕ NTotal (where N is the sample size, X is the electrolyte composition and subscript numerals refer to separate studies). Sources: Sato et al. [79], Patterson et al. [191], Allan and Wilson [246], van den Heuvel et al. [248], Yousef and Dill [251], Hayden et al. [255], Collins [256], Locke et al. [257], Emrich et al. [258], Costa et al. [259], Cage et al. [260], Boisvert et al. [261], Fukumoto et al. [262] and Saat et al. [263].](https://figures.cochat.ai/paper-figures/b6ae458e11ab4f6c92ab4809fe9a14cf/regional-variations-in-transepidermal-water-loss-eccrine-sweat-gland-density-figure-9.jpg)
![Figure 10 A quadrant diagram for estimating fluid and sodium replacement rates. This prediction uses heart rates obtained during steady-state cycling in the heat (36°C, 50% relative humidity). Data were collected from six, fully-hydrated and unacclimatised females [268]. Regressions show 95% confidence intervals. Commencing from position 1, enter the quadrant to successively approximate the oxygen consumption (position 2), core temperature (position 3) and sweat rate (position 4) that would obtain for the measured heart rate. Predictions of sodium (position 5) and fluid replacement rates (position 6) to sustain body-fluid and electrolyte homeostasis can then be approximated.](https://figures.cochat.ai/paper-figures/0657d9e0de4642888321338c55fc8299/regional-variations-in-transepidermal-water-loss-eccrine-sweat-gland-density-figure-10.jpg)
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
The cited source doesn’t support the claim as written.
In the citing paper
“For instance, sweat secretion rates can be lower than 10 nL min−1 cm−2 at low secretion sites such as arm and leg, and can reach on the order of 100 nL min−1 cm−2 at high secretion areas like the palm and foot29,30.”
From A wearable patch for continuous analysis of thermoregulatory sweat at rest (2021) · cites this paper as [29]
Checked by a reasoning model — may be wrong.
Experimental — accuracy not yet measuredThe cited source doesn’t support the claim as written.
In the citing paper
“The results agree with the literatures which showed that palm and fingers have the highest secretion rate29.”
From A wearable patch for continuous analysis of thermoregulatory sweat at rest (2021) · cites this paper as [29]
Checked by a reasoning model — may be wrong.
Experimental — accuracy not yet measuredThe source backs part of the claim, not all of it — or backs it for a different population, condition or comparison.
In the citing paper
“Some studies report sweat [K+] values with a slightly broader range (e.g., ~ 2 to 8 mmol/L) than blood plasma”
From Physiological mechanisms determining eccrine sweat composition (2020) · cites this paper as Taylor and Machado-Moreira 2013
Experimental — accuracy not yet measuredThe source backs part of the claim, not all of it — or backs it for a different population, condition or comparison.
In the citing paper
“This is especially relevant in athletics, where proper fluid replacement during practice and competition is critical for ensuring physical and mental well-being (43, 44).”
From Regional and correlative sweat analysis using high-throughput microfluidic sensing patches toward decoding sweat (2019) · cites this paper as [44]
Experimental — accuracy not yet measuredThe source backs part of the claim, not all of it — or backs it for a different population, condition or comparison.
In the citing paper
“Maintaining fluid/electrolyte balance is essential for healthy vital functions.”
From Regional and correlative sweat analysis using high-throughput microfluidic sensing patches toward decoding sweat (2019) · cites this paper as [44]
Experimental — accuracy not yet measured
8 more claims about this paper
Create a free account to see every claim other papers make about this one.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
(1992) · Applied Ergonomics · doi:10.1016/0003-6870(92)90318-p · Cited by 5,737
Åstrand, P. O., & Ryhming, I. (1954) · Journal of Applied Physiology · doi:10.1152/jappl.1954.7.2.218 · Cited by 1,558 · cited 1×
“exercise-induced increments in heart rate [265] and that”
BackgroundScheuplein, R. J., & Blank, I. H. (1971) · Physiological Reviews · doi:10.1152/physrev.1971.51.4.702 · Cited by 1,398 · cited 3×
“Indeed, the steady-state water flux through the skin from the abdomen is about 10% of that observed from the plantar surface of the foot and 30% of that from the palm [27].”
BackgroundInfluentialHuman biology: A guide to field methods;
Weiner, J. S., & Lourie, J. A. (1969) · Medical Entomology and Zoology · Cited by 981
Advances in Comparative and Environmental Physiology: Volume 7
Houlihan, D. F., Livingstone, D. R., & Lee, R. F. (1991) · Advances in Comparative and Environmental Physiology · doi:10.1007/978-3-642-75897-3 · Cited by 738
Biology of sweat glands and their disorders. I. Normal sweat gland function
Sato, K., Kang, W. H., Saga, K., & Sato, K. T. (1989) · Journal of the American Academy of Dermatology · doi:10.1016/s0190-9622(89)70063-3 · Cited by 717 · cited 2×
“A discontinuous layer of myoepithelial cells separates the epithelial cells from the basement membrane [9,53,55].”
BackgroundGeneral Characteristics of Sympathetic Activity in Human Skin Nerves
Hagbarth, K. ‐., Hallin, R. G., Hongell, A., Torebjörk, H. E., & Wallin, B. G. (1972) · Acta Physiologica Scandinavica · doi:10.1111/j.1748-1716.1972.tb05167.x · Cited by 688
Physiological and behavioral temperature regulation
Hardy, J. D., Gagge, A. P., & Stolwijk, J. A. J. (1970) · Thomas eBooks · Cited by 668
Malaparte, C. (1988) · Cited by 601
Esophageal, rectal, and muscle temperature during exercise
Saltin, B., & Hermansen, L. (1966) · Journal of Applied Physiology · doi:10.1152/jappl.1966.21.6.1757 · Cited by 557 · cited 1×
“For instance, it is well known that oxygen consumption increases linearly with exercise-induced increments in heart rate [265] and that body core temperature is intrinsically linked with oxygen consumption [266].”
Background
Research works printed but not linked: 27
- Kuno Y: Human Perspiration. 1956, Springfield: C.C. Thomas
- Quincy J: Medicina Statica: Being the Aphorisms of Sanctorius. 1712, London: Printed for William Newton
- Wendt A: Über die menschliche Epidermis. Müller Arch. 1834, 278-291.
- Krause KFT: Handwörterbuch der Physiologie. Edited by: Braunschweig WR. 1844, Germany: F. Vieweg and Sohn, 108-186. Die Haut, 2,
- Ranvier L-A: Le mécanisme de la sécrétion. Schwalbe Jahresber. 1887, 16: 388-392.
- Schiefferdecker P: Die Hautdrüsen des Menschen und der Säugetiere, ihre biologische und rassenanatomische Bedeutung, sowie die Muscularis sexualis. Biol Zentralblatt. 1917, 37: 534-562.
- Sanctorius S: De statica medicina. 1614
- MacPherson RK, Newling PSB: Salt concentration and rate of evaporation of sweat. J Physiol. 1954, 123: 74P-
- Benedict FG, Benedict CG: Perspiratio insensibilis: ihr Wesen und ihre Ursachen. Biochem Ztschr. 1927, 186: 278-312.
- Buettner KJK, Odland GF: Physical factors of the skin barrier layer and water diffusion into human skin. Fed Proc. 1957, 16: 18-
- Galeotti G, Macri NM: Über die Perspiratio insensibilis unter normalen und pathologischen Bedingungen. Biochem Z. 1914, 67: 472-482.
- Ikeuchi K, Kuno Y: On the regional differences of the perspiration on the surface of the human body. J Orient Med. 1927, 7: 106-107.
- Renaut J: Dispositif anatomique et mécanisme de l'excrétion des glandes sudoripares. Ann Dermatol. 1894, 5: 1101-1104.
- Ogata K: Functional variations in human sweat glands, with remarks upon the regional differences of the amount of sweat. J Oriental Med. 1935, 23: 98-101.
- Szabo G: The number of eccrine sweat glands in human skin. Adv Biol Skin. 1962, 3: 1-5.
- Ojikutu RO: Die Rolle von Hautpigment und Schweissdrusen in der Klima-anpassung des Menschen. Homo. 1965, 16: 77-95.
- Morimoto T: Sweat secretion. The Physiology and Pharmacology of the Skin. Edited by: Jarrett A. 1978, London: Academic Press, 1611-1621.
- Eichna LW, Bean WB, Ashe WF, Nelson N: Performance in relation to environmental temperature. Bull Johns Hopkins Hosp. 1945, 76: 25-58.
- Machado-Moreira CA, Barry RJ, Vosselman MJ, Taylor NAS: Thermal and non-thermal sweating: what you see is not necessarily what you get. J Physiol Sci. 2009, 59 (Suppl. 1): 167-
- Féré C: Note sur des modifications de la résistance électrique sous l'influence des excitations sensorialles et des emotions. CR Séances Soc Biol Fil. 1888, 5: 217-219.
- Yen TJ: A new method for the measurement of the secretion of a single sweat gland. Med J Southern Manchuria. 1924, 12: 507-
- Ichihashi T: Method of observing sweat drops on the skin covered with oil, and several observations with this method. J Orient Med. 1936, 25: 107-108.
- Werner J, Graener R, Heising M, Tutughamiarsa TB: A microprocessor-supported device for the measurement of human sweat rate. Med Biol Engin Comp. 1985, 23: 1037-1038.
- Oehler J: Über die Hauttemperatur der gesunden Menschen. Deutsches Arch f klin Med. 1904, 80: 245-262.
- Takahara K: Observations on the discharge of sweat from a single sweat gland. J Oriental Med. 1936, 24: 4-
- van Beaumont W, Bullard RW, Banerjee MR: Observations on human sweating by resistance hygrometry. Dermatol Digest. 1966, 75-87.
- Gordon CJ: Non-thermoregulatory factors in humans during exercise and rest: influences on thermoeffector function. 2010, PhD thesis. University of Wollongong, Department of Biomedical Science
Cited by
Items 401–500 of 509
Berth‐Jones, J., & Tebbs, V. M. (2021) · Springer eBooks · doi:10.1007/978-3-319-45134-3_41-1 · Cited by 3
Wearable Transdermal Biosensors
Rao, G., Srinivasan, V., Sheffield, Z., Ahuja, P., Kumar, S., Ge, X., Dighe, K., & Sundberg, C. A. (2024) · Springer eBooks · doi:10.1007/978-981-99-8122-9_5 · Cited by 3
Predicting Hand Surface Area from a Two-Dimensional Hand Tracing
O'Mara, M. (2017) · Digital Commons - University of South Florida (University of South Florida) · Cited by 2
Song, C., Zhou, C., Sang, H., Zhao, D., & Liu, Y. (2025) · Building and Environment · doi:10.1016/j.buildenv.2025.112627 · Cited by 2
Assessment of Sweat Rate in Different Sports
Das, A., & Ramesh, V. (2025) · Methods and protocols in food science · doi:10.1007/978-1-0716-4370-9_15 · Cited by 1
Du, X., Wu, L., Yu, R., Fan, Z., Chen, Y., Zhou, T., Yang, Z., Liu, Y., Zhu, M., & Pan, S. (2025) · ACS Sensors · doi:10.1021/acssensors.5c02247 · Cited by 1
Amano, T., Ichinose‐Kuwahara, T., Ueda, H., Kondo, N., & Inoue, Y. (2025) · Journal of Thermal Biology · doi:10.1016/j.jtherbio.2025.104308 · Cited by 1
Development of wearable thermal MEMS sensor for sweat-rate measurement
YOSHIZAWA, H., YASUDA, H., ICHIKAWA, Y., Mukaimoto, T., Yanagita, S., Suzuki, T., Shitanda, I., & Motosuke, M. (2025) · Journal of Thermal Science and Technology · doi:10.1299/jtst.25-00222 · Cited by 1
Chang, M.-H., Chou, L., Liu, Y.-J., Hsu, C.-H., Yang, Y.-Y., Juan, B.-C., Lin, G. L., Lin, Y.-J., Huang, Y., Kumar, N., et al. (2026) · Digest of technical papers/Digest of technical papers - IEEE International Solid-State Circuits Conference · doi:10.1109/isscc49663.2026.11409179 · Cited by 1
MIP-based wearable sweat sensors: From materials design to integrated systems
Wang, Z., Chen, X., Dong, W., & Wang, Z. (2026) · Materials Science and Engineering R Reports · doi:10.1016/j.mser.2026.101227 · Cited by 4
Lee, J., Moon, J.-H., kim, Y., Kim, H., Kim, E., Lee, H., Yoon, S., Chon, S., Lee, Y., & Park, J. (2026) · Scientific Reports · doi:10.1038/s41598-026-47148-8 · Cited by 3
Headset-Type Biofluorometric Gas Sensor with CMOS for Transcutaneous Ethanol from the Ear Canal
Zhang, G., Huang, D., Ichikawa, K., Iitani, K., Nakajima, Y., & Mitsubayashi, K. (2026) · Sensors · doi:10.3390/s26092817 · Cited by 1
“The sweat gland density in the external ear area is much lower than that of the palm, forearm, and cheek [27].”
Retzinger, A. C. (2026) · Frontiers in Microbiology · doi:10.3389/fmicb.2026.1714798 · Cited by 1
Han, Y., Fernandes, C. S., Davis, E., & Malakooti, M. H. (2026) · ACS Applied Materials & Interfaces · doi:10.1021/acsami.6c07022 · Cited by 2
Noninvasive measurement of glucose and lactate in thermoregulatory sweat in neonates and adults
Liu, X., Gowers, S. A. N., Gourin, B., McClure, Z. E., Dado, S., Abraham, T., Banerjee, J., & Boutelle, M. G. (2026) · Science Advances · doi:10.1126/sciadv.aec4166 · Cited by 2
Pang, J. (2026) · Biomedical Chromatography · doi:10.1002/bmc.70574 · Cited by 1
Saha, T., Khan, M. I., Longardner, K., Sabbagh, B., Zheng, K., Mendoza, H., Ji, G., Choi, B., Wang, Z., Pham, R., et al. (2026) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.2610453123 · Cited by 1
Zhaldak, A., Ivanko, O., & Deputat, Y. N. (2021) · Ukrainian Scientific Medical Youth Journal · doi:10.32345/usmyj.2(124).2021.53-63 · Cited by 1
Fraga, J. C. D. L. T., & Mesa‐Álvarez, L. (2016) · Piel · doi:10.1016/j.piel.2015.10.009 · Cited by 1
Deposition of Metals on the Skin and Quantification of Skin Exposure
Midander, K. (2018) · Springer eBooks · doi:10.1007/978-3-319-58503-1_6 · Cited by 1
Heartbeat and Respiration: Toward a Functional Chronobiology
Furst, B. (2019) · Springer eBooks · doi:10.1007/978-3-030-25062-1_23 · Cited by 1
Impact of airflow on body cooling in exercise: an exploratory study
Nogueira, P. H., da Silva, A. G., Oliveira, S. A., Sillero‐Quintana, M., & Marins, J. C. B. (2021) · Archivos de medicina del deporte: revista de la Federación Española de Medicina del Deporte y de la Confederación Iberoamericana de Medicina del Deporte · doi:10.18176/archmeddeporte.00050 · Cited by 1
Wissler, E. H. (2018) · Springer eBooks · doi:10.1007/978-3-662-57397-6_8 · Cited by 1
Effectiveness of smart wrist wearables for distinguishing physical and cognitive demands
Cha, J. S., Ausri, F., Mudge, L., & Yu, D. (2022) · IISE Transactions on Healthcare Systems Engineering · doi:10.1080/24725579.2022.2142867 · Cited by 1
“The ventral forearm, however, has a density of around 159 glands per square centimeter (Taylor & Machado-Moreira, 2013).”
BackgroundHong, S., Heo, S., & Lee, B. (2022) · International Journal of Human-Computer Studies · doi:10.1016/j.ijhcs.2022.102985 · Cited by 1
Dose-dependent nonthermal modulation of whole body heat exchange during dynamic exercise in humans
Notley, S. R., Akerman, A. P., D’Souza, A. W., Meade, R. D., McCourt, E. R., McCormick, J. J., & Kenny, G. P. (2023) · American Journal of Physiology-Regulatory, Integrative and Comparative Physiology · doi:10.1152/ajpregu.00203.2023 · Cited by 1
Watkins, Z., McHenry, A., & Heikenfeld, J. C. (2023) · Advances in biochemical engineering, biotechnology · doi:10.1007/10_2023_238 · Cited by 2
Sample preparation using microfluidic technologies for non-invasive tests
Oksuz, C., Tarim, E. A., Ozcan, H. A., Koc, S., & Tekin, H. C. (2024) · Elsevier eBooks · doi:10.1016/b978-0-443-15978-7.00038-2 · Cited by 1
Yin, X., Adelaars, S., Peri, E., Pelssers, E., den Toonder, J. M. J., Bouwman, R. A., van de Kerkhof, D., & Mischi, M. (2025) · Frontiers in Physiology · doi:10.3389/fphys.2025.1547117 · Cited by 3
Boisa, N. (2016) · Jordan Journal of Chemistry · Cited by 1
Developments in silicone technology for use in stoma care
Swift, T., Westgate, G. E., Onselen, J. V., & Lee, S. (2021) · British Journal of Nursing · doi:10.12968/bjon.2021.30.sup8.7 · Cited by 1
정다희 (2017) · Seoul National University Open Repository (Seoul National University) · Cited by 1
“Hidroscopy”-Suggesting Dermoscopy for expendable indications
Sonthalia, S., Errichetti, E., & Sehgal, V. N. (2019) · Skin Research and Technology · doi:10.1111/srt.12724 · Cited by 1
Siah, J. (2020) · Murdoch University Research Portal · Cited by 1
Electrochemical Wearable Devices
Lee, B. H., & Daniele, M. A.-A. (2021) · Wiley eBooks · doi:10.1002/9783527610426.bard030113 · Cited by 1
West, A. (2020) · Figshare · doi:10.26174/thesis.lboro.12030174 · Cited by 2
Kadri, M. E. (2020) · theses.fr (ABES) · doi:10.70675/2e1ddea6zbfd9z41b0z90b2z9ca2e3e457c3 · Cited by 8
The Influence of Sex on the Osmoreceptor Modulation of Heat Loss Responses
Ramírez, B. (2013) · uO Research (University of Ottawa) · doi:10.20381/ruor-3378
“This is followed by an influx of calcium ions that activates the movement of sodium and chloride ions into the cell, thus creating an osmotic gradient that favors the movement of water from the plasma into the gland (Taylor & Machado-Moreira, 2013).”
A measurement setup to test instruments for detecting sweat
Verhaart, J. J., Snoeren, R. R., Li, R., & Zeiler, W. (2015) · TU/e Research Portal
Immersion Suits for Helicopter Transportation
Sweeney, D. H. (2015) · Elsevier eBooks · doi:10.1016/b978-1-78242-187-0.00009-2
Zhu, Z., Li, R., & Pan, T. (2017) · IEEE International Conference on Nano/Micro Engineered and Molecular Systems · doi:10.1109/nems.2017.8017033
Frequency of resonance of human sweat duct in different modes of operation
Tripathi, S. R., Takahasi, S., Kinumura, K., & Kawase, K. (2018) · Optical Interactions with Tissue and Cells · doi:10.1117/12.2289322
“The high duct density in child is due to the fact that the glands start to appear after a few gestational weeks, their development is complete after 22 weeks of gestation, and the number remains fairly constant [10].”
BackgroundA System Centric View of Modern Structured and Sparse Inference Tasks
Jain, S. (2017) · University of Minnesota Digital Conservancy (University of Minnesota)
Brueck, A., Bates, K. D., Wood, T., House, W., Martinez, Z., Peters, S., Root, B., Yelamarthi, K., & Kaya, T. (2018) · IEEE International Conference on Electro Information Technology · doi:10.1109/eit.2018.8500209
“Thermoregulation occurs through eccrine sweat glands that are throughout the body [1].”
BackgroundDevelopment of a Non-enzymatic, Non-invasive Sensor for Detection of Lactate in Sweat
ljungh, A. (2018) · Chalmers Publication Library (Chalmers University of Technology)
Alleviating Heat Strain During Exercise: Hand Cooling and Thermoregulation
Ruddock, A. D. (2017) · Sheffield Hallam University · doi:10.7190/shu-thesis-00094
“The largest sweat gland densities are reported to be present on the palmar surface of the hands and the soles of the feet and in theory should have the highest sweat rates [20].”
BackgroundVideo Luminance Levels for Human Skin Tones in Hybrid Log-Gamma Video
Thompson, S. (2019) · SMPTE Motion Imaging Journal · doi:10.5594/jmi.2019.2894226
“Using a Konika-Minolta CS2000 photospectrometer, we measured the reflectance of the Figure 3: Skin tone reflectance vs HLG luma for ideal camera with region labels from (3)”
BackgroundMethodInfluentialMeasured Electrical Properties of Skin Using a Homemade Electrode: Preliminary Results
Brunnquell, S., & Bertemes-Filho, P. (2019) · World Congress on Medical Physics and Biomedical Engineering, September 7 - 12, 2009, Munich, Germany · doi:10.1007/978-981-13-2517-5_108
Holes in wrist patches improve wearing comfort
Klous, L., Tiest, W. M. B., van Dorst, P. W. M., van der Linde, M. J. A., & Daanen, H. A. M. (2019) · International Journal of Clothing Science and Technology · doi:10.1108/ijcst-07-2018-0102
Repeated Exercise in Heat and Exertional Alterations to Thermoregulation (REHEAT)
Anderson, C. A. J. (2020) · Queensland University of Technology · doi:10.5204/thesis.eprints.135793
LCMS Measurement of Steroid Biomarkers Collected from Palmar Sweat.Preprint
Hyde, J., & Runyon, J. R. (2020) · ChemRxiv · doi:10.26434/chemrxiv.12931769.v1
der Schyff, R. V. (2019) · DUT Open Scholar (Durban University of Technology) · doi:10.51415/10321/3882
Preparation of the artificial “skin” uniform sweating simulation device
Zheng, H., Liu, M., Yang, X., Cao, Y. F., Nie, W., Wang, S., & Zhang, T. (2022) · Scientia Sinica Technologica · doi:10.1360/sst-2022-0114
Desert and tropical environments
Gunga, H. (2020) · Elsevier eBooks · doi:10.1016/b978-0-12-815942-2.00005-5
Hashimoto, S., Yamashita, N., Taniguchi, K., & Sugita, M. (2022) · 体力科學 · doi:10.7600/jspfsm.71.333
Development of a prototype toe sensor for detection of diabetic peripheral small fiber neuropathy
Tronstad, C., Pabst, O., Amini, M., Kleggetveit, I. P., Elvebakk, O., Martinsen, Ø. G., Jenssen, T. G., Hisdal, J., Berg, T. J., & Qvigstad, E. (2022) · Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC) · doi:10.1109/embc48229.2022.9871101
“The volar surface of the distal toe phalanx is among the skin sites with the highest densities of eccrine sweat glands [24], providing a sensitive measuring site for sudomotor activity.”
BackgroundSkin wrinkling an Händen und Füßen – Theorie und Praxis
Jasinskas, M., Frerichs, O., Fansa, H., & Walle, L. (2022) · Handchirurgie · Mikrochirurgie · Plastische Chirurgie · doi:10.1055/a-1894-7267
“Das periphere Nervensystem scheint Einfluss auf die Hautfaltenbildung an Händen und Füßen zu haben [5, 6].”
BackgroundRocour, S., & Maillard, H. (2023) · EMC - Cosmetologia Medica e Medicina degli Inestetismi Cutanei · doi:10.1016/s1776-0313(22)47512-5
Grandjean, D., Gallet, C., Julien, C., Blondot, M., & Bacqué, H. (2022) · Bulletin de l Académie vétérinaire de France · doi:10.3406/bavf.2022.71013
Healthful Connected Living: Vision and Challenges for the Case of Obesity
Singh, M. P., Chi, M., & Misra, V. (2023) · IEEE Internet Computing · doi:10.1109/mic.2023.3257994 · Cited by 1
Poulsen, A. H. (2021) · VBN Forskningsportal (Aalborg Universitet) · doi:10.54337/aau450850794
Хлор (Cl) – значение для организма и здоровья, где содержится
Наталья, Т., & Татьяна, Е. (2022) · Журнал здорового питания и диетологии · doi:10.59316/.vi20.173
Peel, J. (2024) · Cronfa (Swansea University) · doi:10.23889/suthesis.66881
Stenkina, M., & Lee, J. (2024) · The Korean Journal of Community Living Science · doi:10.7856/kjcls.2024.35.3.391
Wearable Sweat Sensors: A Review
Chowdhury, I., Ali, M. Y., & Howlader, M. M. R. (2024) · Elsevier eBooks · doi:10.1016/b978-0-323-95478-5.00015-7 · Cited by 2
Fingerprint Sweat Pore Density in Patients with Oligodontia: A Controlled Clinical Trial
Schmid, J. Q., Reimann, J., Middelberg, C., Oelerich, O., Stamm, T., & Hohoff, A. (2024) · Biomedicines · doi:10.3390/biomedicines12122768
Midoh, N., Koike, Y., Koike, R., Sato, R., & Fudono, S. (2025) · NIPPON SHOKUHIN KOGYO GAKKAISHI · doi:10.3136/nskkk.nskkk-d-24-00104
Secreciones sudorípara y sebácea
Aubert‐Pouëssel, A. (2025) · EMC - Dermatología · doi:10.1016/s1761-2896(24)50023-1
Quantification of Palmar and Digital Epidermal Thickness and Sweat Duct Density
Jones, E. A., Mughal, H. N., Moscalu, R., Columb, M. O., Duff, C. G., Dickinson, M., Reid, A. J., & Murphy, R. (2025) · Clinical Anatomy · doi:10.1002/ca.24292
Parlak, E. A., Ilkaz, N., Ayhan, H., & İyigün, E. (2025) · International Journal of Occupational Safety and Ergonomics · doi:10.1080/10803548.2025.2503580
Gil-Calvo, M., Jimenez‐Perez, I., Pérez‐Soriano, P., & Priego‐Quesada, J. I. (2025) · Springer eBooks · doi:10.1007/978-3-031-93311-0_14
Özgür, M., Yılmaz, H. Ö., Onay, T., Yılmaz, S. K., Tamer, F., Karakaya, Z. E., Günalan, E., Yıldırım, G., Serçe, H., Tazeoğlu, A., et al. (2025) · Akademisyen Kitabevi eBooks · doi:10.37609/akya.3728
Esposito, V., Sciurti, E., Calogiuri, A., Bellisario, D., Velardi, L., Casino, F., Blasi, L., & Francioso, L. N. (2025) · Measurement Sensors · doi:10.1016/j.measen.2025.101977 · Cited by 2
On Haptic Cues, Dimensions, and Stability in Touch
Driller, K. K. (2025) · Multisensory Research · doi:10.1163/22134808-bja10173
Belgardt, A. J., Kalhoff, H., Kersting, M., Sinningen, K., Bechtel, B., & Lücke, T. (2025) · BMC Pediatrics · doi:10.1186/s12887-025-06271-7
Subathra, Y., C, J. C. M., & Ramakrishnan, K. (2025) · Proceedings of the Institution of Mechanical Engineers Part H Journal of Engineering in Medicine · doi:10.1177/09544119251398453
In, M. K. (2022) · Refubium (Universitätsbibliothek der Freien Universität Berlin) · doi:10.17169/refubium-33915
Gotsmy, M., Brunmair, J., Büschl, C., Gerner, C., & Zanghellini, J. (2022) · Figshare · doi:10.6084/m9.figshare.21151115
Rapid Heat Acclimation Strategies for Use in the Military
Ashworth, E. T. (2021) · Tuwhera (Auckland University of Technology) · Cited by 1
Lifestyle Factors Influencing Heat Stress Response: A Review
Zlatar, T., da Cruz, F. M., Valério, B. M. V., Martins, A. R. B., Lago, E. M. G., Martins, L. B., Baptista, J. S., & Júnior, B. B. (2018) · Portuguese National Funding Agency for Science, Research and Technology (RCAAP Project by FCT) · Cited by 1
The effect of the UVB light in epidermal cells of Xeroderma Pigmentosum-C
Sánchez-Mayoral Amador, R. (2015) · e-Archivo (Carlos III University of Madrid)
Skin Phantom for Biowearable Device Testing
Karimjee, R., Fitzwilson, B., & Spice, J. (2021) · Scholar Commons (Santa Clara University)
Developing Nutritional Considerations for Elite Squash Players Through a Performance Problems Lens
Turner, O. J. (2024) · Sheffield Hallam University · doi:10.7190/shu-thesis-00748
Gou, X., Sun, L., Su, X., Hu, Y., Cao, X., & Yuan, Y. (2026) · Cell Reports Physical Science · doi:10.1016/j.xcrp.2026.103105
Makas, A. L., Troshkov, M. L., Podyachev, S. P., & Kudryavtsev, A. S. (2026) · Analitika i kontrolʹ · doi:10.15826/analitika.2025.29.4.006
Facial skin temperature as a biomarker for motion sickness
Louvenberg, S., Bos, J. E., Nijskens, L., van der Hurk, S. E., & Souman, J. L. (2026) · Applied Ergonomics · doi:10.1016/j.apergo.2026.104765 · Cited by 1
Sweat output on the dorsal aspect of the forearm and foot
Mack, G. W., Young, A. M., Bahr, K., Renfro, A., & Robinson, A. (2026) · Journal of Applied Physiology · doi:10.1152/japplphysiol.00459.2025
Etude fonctionnelle de la communauté microbienne de la peau par une approche métagénomique
Mathieu, A. (2014) · theses.fr (ABES) · doi:10.70675/879785bfz77f7z452dzbfb2zb123a5c87cd8 · Cited by 1
Détection de situations à risques pour des personnes fragiles sur des données multimodales
Yebda, T. (2022) · theses.fr (ABES) · doi:10.70675/e50bced2zd936z4369zbcf1zc0773a26d47c
Domenico, H. D. (2023) · theses.fr (ABES) · doi:10.70675/99cdde1dza6ffz482ez840ez34bade84539a · Cited by 2
From Cue to Construct : Cues, Mechanisms, and Stability in Haptic Perception
Driller, K. K. (2024) · theses.fr (ABES) · doi:10.70675/bda39103z88d0z4088z8a5fz632c3ab5f09b
Laser-Induced Breakdown Spectroscopy as a Tool for the Detection of Trace Elements in Sweat
Sreeja, K., V, P, S. T., & Anoop, K. K. (2026) · Journal of Condensed Matter · doi:10.61343/jcm.v4i01.218
Persson, A., Łyczyńska, Z., Shahata, M., Kotlyar, O., Engwall, M., Särndahl, E., Ehrström, M., Melican, K., Wallinder, I. O., & Alijagić, A. (2026) · Chemical Research in Toxicology · doi:10.1021/acs.chemrestox.6c00100
Blount, H. (2026) · ePrints Soton (University of Southampton) · doi:10.5258/soton/pg/t114
Xie, Y., Liao, J., Lin, N., Wu, X., Deng, S., Gao, L., Su, Q., Lu, X., Liu, F., Yang, S., et al. (2026) · Sensors and Actuators A Physical · doi:10.1016/j.sna.2026.117950
Aerosol jet and 3D printed impedance-based wearable sensors for local sweating rate monitoring
Dong, K., Wen, H., Huang, F., Gao, Z., Cao, Y., Xu, X., Ye, Q., & Liu, Q. (2026) · Microchemical Journal · doi:10.1016/j.microc.2026.118496
Enfermedades dermatológicas localizadas en la nuca
López-Pérez, M. P., Jácome-Vargas, A., & Chaparro-Reyes, D. (2026) · Piel · doi:10.1016/j.piel.2026.03.005
Non-invasive in vivo lactate monitoring via NIR spectroscopyPreprint
Lehnert, T., Seidel, S., Euchner, J., Thierbach, A., Schmidt, F. P., Ögün, C. M., & Hermes, W. (2026) · bioRxiv (Cold Spring Harbor Laboratory) · doi:10.64898/2026.06.23.733906
“Key features include also high local sweat flux, elevated transepidermal water loss, and dense peri-glandular capillarization, all of which support faster local solute exchange and a high ISF-specific optical path [19, 20].”
Microneedle technology for biological monitoring and diagnosis
Chen, Y., & Quan, G. (2026) · Elsevier eBooks · doi:10.1016/b978-0-443-45544-5.00011-7
Mori, K., & Tsunoda, M. (2026) · Talanta · doi:10.1016/j.talanta.2026.130480
Metadata
- Authors
- Taylor, N. A., & Machado-Moreira, C. A.
- Affiliations
- University of Wollongong (AU)
- Corresponding author
- Taylor, Nigel AS
- ORCID
- Taylor, Nigel AS
- Venue
- Extreme Physiology & Medicine
- Published
- 2013-02-01
- Volume
- 2
- Issue
- 1
- Pages
- 4-4
- ISSN
- 2046-7648 (ISSN-L)
- PMC
- PMC3710196
- OpenAlex
- W2131490519
- Cited by
- 490
- References
- 260
- Citations by year
- 2026: 31 · 2025: 47 · 2024: 56 · 2023: 44 · 2022: 45 · 2021: 57 · 2020: 44 · 2019: 38 · 2018: 38 · 2017: 26 · 2016: 14 · 2015: 25 · 2014: 16 · 2013: 8
- FWCI
- 14.62
- Type
- journal article
- Language
- en
- Open access
- hybrid
- doi.org
- Licence
- cc-by
- creativecommons.org/licenses/by/2.0 (tdm)
- Locations
- Extreme Physiology & Medicine (publishedVersion, cc-by)
- Europe PMC (PubMed Central) (publishedVersion, cc-by)
- PubMed Central (publishedVersion, cc-by)
- PubMed (publishedVersion)
- Research Online (University of Wollongong) (submittedVersion)
- Figshare (submittedVersion)
- Funders
- Coordenação de Aperfeiçoamento de Pessoal de Nível Superior
- Ministério da Educação
- Defence Science and Technology Group
- Topics
- Health Sciences › Medicine › Physiology (medical) › Thermoregulation and physiological responses
- Health Sciences › Medicine › Physiology (medical) › Cardiovascular and exercise physiology
- Physical Sciences › Materials Science › Polymers and Plastics › Textile materials and evaluations
- Keywords
- transepidermal water loss, eccrine sweat glands, sweat gland density, insensible water loss, passive heating, exercise thermoregulation, evaporative cooling
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.