Regional variations in transepidermal water loss, eccrine sweat gland density, sweat secretion rates and electrolyte composition in resting and exercising humans
Open accessThe DOI matches its Crossref record; 259 of the 260 references it cites were found in a registry or an index.
Abstract
Literature from the past 168 years has been filtered to provide a unified summary of the regional distribution of cutaneous water and electrolyte losses. The former occurs via transepidermal water vapour diffusion and secretion from the eccrine sweat glands. Daily insensible water losses for a standardised individual (surface area 1.8 m2) will be 0.6-2.3 L, with the hands (80-160 g.h-1) and feet (50-150 g.h-1) losing the most, the head and neck losing intermediate amounts (40-75 g.h-1) and all remaining sites losing 15-60 g.h-1. Whilst sweat gland densities vary widely across the skin surface, this same individual would possess some 2.03 million functional glands, with the highest density on the volar surfaces of the fingers (530 glands.cm-2) and the lowest on the upper lip (16 glands.cm-2). During passive heating that results in a resting whole-body sweat rate of approximately 0.4 L.min-1, the forehead (0.99 mg.cm-2.min-1), dorsal fingers (0.62 mg.cm-2.min-1) and upper back (0.59 mg.cm-2.min-1) would display the highest sweat flows, whilst the medial thighs and anterior legs will secrete the least (both 0.12 mg.cm-2.min-1). Since sweat glands selectively reabsorb electrolytes, the sodium and chloride composition of discharged sweat varies with secretion rate. Across whole-body sweat rates from 0.72 to 3.65 mg.cm-2.min-1, sodium losses of 26.5-49.7 mmol.L-1 could be expected, with the corresponding chloride loss being 26.8-36.7 mmol.L-1. Nevertheless, there can be threefold differences in electrolyte losses across skin regions. When exercising in the heat, local sweat rates increase dramatically, with regional glandular flows becoming more homogeneous. However, intra-regional evaporative potential remains proportional to each local surface area. Thus, there is little evidence that regional sudomotor variations reflect an hierarchical distribution of sweating either at rest or during exercise.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Figures
![Figure 1 Regional variations in transepidermal water loss. Data were extracted from four studies: (A) Galeotti and Macri [42]. (B) Ikeuchi and Kuno [43]. (C) Burch and Sodeman [44]. (D) Park and Tamura [45]. Data are reported in identical units and arranged in descending order. To highlight differences among sites within each study, two ordinate scales have been used. Nine sites from Park and Tamura [45] have been excluded for simplicity, leaving only the sites in common with the other reports.](https://figures.cochat.ai/paper-figures/39e827f1881642bf9854235178b27a44/regional-variations-in-transepidermal-water-loss-eccrine-sweat-gland-density-figure-1.jpg)
![Figure 2 The distribution of physiologically active, eccrine sweat glands in humans. Data are means (with 95% confidence intervals) derived across 31 studies, with an average sample size of 23 individuals per data set. The numbers above each bar indicate data sets used for that site, with the site-specific sample sizes in parenthesis (B). Means were computed as follows: regional density = ((N1 × density1) + (N2 × density2) + … (Ni × densityi)) / NTotal (where N is the sample size and subscript numerals refer to separate studies). (A) shows all sites investigated. These data were subsequently grouped into 14 larger regions (B). The active sweat glands for one region (axilla) have not been investigated, so this value was taken to be 90% of that reported in Table 1. Sources: Clark and Lhamon [60], Ogata [63], Randall [64], Thompson [65], Willis et al. [66], Roberts et al. [78], Sato and Dobson [85], Inoue et al. [86], Kondo et al. [87], Peter and Wyndham [88], Buono [89], Gibson and Shelley [90], MacKinnon [91] (with the original calculation error corrected), Collins et al., [92], Hellon and Lind [93], Silver et al. [94], Ojikutu [95], Sargent and Weinman [96], Juniper and Dykman [97], Toda [98], Bar-Or et al. [99], Knip [100], Knip [101], Schaefer et al. [102], Catania et al. [103], Behm et al. [104], Inoue et al. [105], Kondo et al. [106], Inoue et al. [107], Welch et al. [108] and Madeira et al. [109].](https://figures.cochat.ai/paper-figures/497acfb8470d412491775e833a51f3a9/regional-variations-in-transepidermal-water-loss-eccrine-sweat-gland-density-figure-2.jpg)

![Figure 4 Total cutaneous water loss and sweat gland outputs in resting, passively heated individuals. (A) Regional variations in total cutaneous water loss (descending order) and (B) sweat gland output (ordered as in A). (A) is a summation of transepidermal water loss (averaged from Figure 1: dorsal foot was assumed to equal the dorsal hand) and thermoregulatory sweating. Sweat data are means (with 95% confidence intervals across studies) derived from 17 studies (191 subjects: numbers are data sets used for each site), with an average sweat rate across all sites and studies of 0.36 mg.cm−2.min−1. For simplicity, all anterior surfaces of the head were included within the face. For the limbs, data from all surfaces were combined, while the hands and feet were separated according to their dorsal and volar surfaces, with corresponding data obtained from the fingers and toes included within those surfaces. Data for the buttocks came from only two studies with considerable between-study variability and should be treated cautiously. Site-specific sweat rates were computed as follows: regional sweating = ((N1 × SR1) + (N2 × SR2) + … (Ni × SRi)) ∕ NTotal (where N is the sample size, SR is the sweat rate and subscript numerals refer to separate studies). (B) shows variations in sweat gland output, derived by combining data from Figures 2B and 4A. Sources: Machado-Moreira and Taylor [20], Machado-Moreira et al. [21], Ikeuchi and Kuno [43], Burch and Sodeman [44], Park and Tamura [45], Taylor et al. [61], Machado-Moreira et al. [62], Inoue et al. [86], Smith et al. [194], Hertzman [207], Hertzman et al. [213], Machado-Moreira et al. [224], Machado-Moreira et al. [225], Cotter [226], Gordon [227] and Machado-Moreira [228].](https://figures.cochat.ai/paper-figures/4568a62c14be4e0aab466d086e5f99b5/regional-variations-in-transepidermal-water-loss-eccrine-sweat-gland-density-figure-4.jpg)
![Figure 5 Total cutaneous water loss and sweat gland output during dynamic and static exercise. (A) Regional variations in total cutaneous water loss (descending order) and (B) sweat gland output (ordered as in A). (A) is a summation of transepidermal water loss (averaged from Figure 1: dorsal foot was assumed to equal the dorsal hand) and thermal and non-thermal sweating. Data are means (with 95% confidence intervals across studies) derived from 20 studies (214 subjects: numbers are data sets used for each site), with an average sweat rate across all sites and studies of 0.89 mg.cm−2.min−1. For simplicity, all anterior surfaces of the head were included within the face. For the limbs, data from all surfaces were combined, while the hands and feet were separated according to their dorsal and volar surfaces, with data obtained from the fingers and toes included within those surfaces. Data for the buttocks came from only one study. Site-specific sweat rates were computed as follows: regional sweating = ((N1 × SR1) + (N2 × SR2) + … (Ni × SRi)) ∕ NTotal (where N is the sample size, SR is the sweat rate and subscript numerals refer to separate studies). (B) shows variations in sweat gland output, derived by combining data from Figures 2B and 5A. Sources: Taylor et al. [61], Machado-Moreira et al. [62], Sato and Dobson [85], Patterson et al. [156], Weiner [164], Patterson et al. [191], Havenith et al. [192], Smith et al. [194], Takano et al. [208], Kondo et al. [87], Smith and Havenith [233], Machado-Moreira et al. [224], Machado-Moreira et al. [225], Gordon [227], Höfler [234], Ayling [235], Cabanac and Brinnel [236], Libert et al. [237], Cotter et al. [238] and Cotter et al. [239].](https://figures.cochat.ai/paper-figures/1c173e784c2b477b95b5a9c4293a3904/regional-variations-in-transepidermal-water-loss-eccrine-sweat-gland-density-figure-5.jpg)

![Figure 7 Inter- and intra-regional distribution of steady-state thermal sweating (ventilated capsules) for resting individuals. Participants (N = 49) were seated (air temperature 36°C, 60% relative humidity) and wore a heated, water-perfusion suit (40°C–46°C). Data are means with standard deviations extracted from five studies undertaken within the authors' laboratory (sweat capsules (capacitance hygrometry)). Sources: Machado-Moreira et al. [62], Smith et al. [194], Machado-Moreira et al. [224], Machado-Moreira et al. [225] and Machado-Moreira [228].](https://figures.cochat.ai/paper-figures/8f1b3af6887b4f0d81fbb835dc6cac1f/regional-variations-in-transepidermal-water-loss-eccrine-sweat-gland-density-figure-7.jpg)
![Figure 8 Inter- and intra-regional distribution of steady-state sweating during exercise. Data are presented in two forms: (A) Mean sweat rates (closed circles: ventilated capsules) with standard deviations extracted from six studies undertaken in the authors' laboratory (N = 46, cycling: air temperature 36°C, 60% relative humidity: sweat capsules (capacitance hygrometry)). Subjects wore a heated, water-perfusion suit (40°C–46°C). Sources: Taylor et al. [61], Machado-Moreira et al. [62], Smith et al. [194], Machado-Moreira et al. [224], Machado-Moreira et al. [225] and Machado-Moreira [228]. (B) For comparative purposes, averages extracted from the literature for exercise (triangles) are provided (sources identified in Figure 5). Data reported by Smith and Havenith [233] (second exercise intensity) are also provided (open circles).](https://figures.cochat.ai/paper-figures/19dd0d469cdf4a50a86bcb2c7f69343c/regional-variations-in-transepidermal-water-loss-eccrine-sweat-gland-density-figure-8.jpg)
![Figure 9 Regional variations in sweat sodium, chloride and potassium concentrations. Data were obtained from 13 papers that reported both electrolyte concentrations and sweat rates, or information that permitted derivation of the latter. These sweat rate ranges and sample sizes for each site are provided in Table 5. Data are means with 95% confidence intervals across studies. Site-specific sweat compositions were computed as follows: regional composition = ((N1 × X1) + (N2 × X2) + … (Ni × Xi)) ∕ NTotal (where N is the sample size, X is the electrolyte composition and subscript numerals refer to separate studies). Sources: Sato et al. [79], Patterson et al. [191], Allan and Wilson [246], van den Heuvel et al. [248], Yousef and Dill [251], Hayden et al. [255], Collins [256], Locke et al. [257], Emrich et al. [258], Costa et al. [259], Cage et al. [260], Boisvert et al. [261], Fukumoto et al. [262] and Saat et al. [263].](https://figures.cochat.ai/paper-figures/b6ae458e11ab4f6c92ab4809fe9a14cf/regional-variations-in-transepidermal-water-loss-eccrine-sweat-gland-density-figure-9.jpg)
![Figure 10 A quadrant diagram for estimating fluid and sodium replacement rates. This prediction uses heart rates obtained during steady-state cycling in the heat (36°C, 50% relative humidity). Data were collected from six, fully-hydrated and unacclimatised females [268]. Regressions show 95% confidence intervals. Commencing from position 1, enter the quadrant to successively approximate the oxygen consumption (position 2), core temperature (position 3) and sweat rate (position 4) that would obtain for the measured heart rate. Predictions of sodium (position 5) and fluid replacement rates (position 6) to sustain body-fluid and electrolyte homeostasis can then be approximated.](https://figures.cochat.ai/paper-figures/0657d9e0de4642888321338c55fc8299/regional-variations-in-transepidermal-water-loss-eccrine-sweat-gland-density-figure-10.jpg)
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
The cited source doesn’t support the claim as written.
In the citing paper
“For instance, sweat secretion rates can be lower than 10 nL min−1 cm−2 at low secretion sites such as arm and leg, and can reach on the order of 100 nL min−1 cm−2 at high secretion areas like the palm and foot29,30.”
From A wearable patch for continuous analysis of thermoregulatory sweat at rest (2021) · cites this paper as [29]
Checked by a reasoning model — may be wrong.
Experimental — accuracy not yet measuredThe cited source doesn’t support the claim as written.
In the citing paper
“The results agree with the literatures which showed that palm and fingers have the highest secretion rate29.”
From A wearable patch for continuous analysis of thermoregulatory sweat at rest (2021) · cites this paper as [29]
Checked by a reasoning model — may be wrong.
Experimental — accuracy not yet measuredThe source backs part of the claim, not all of it — or backs it for a different population, condition or comparison.
In the citing paper
“Some studies report sweat [K+] values with a slightly broader range (e.g., ~ 2 to 8 mmol/L) than blood plasma”
From Physiological mechanisms determining eccrine sweat composition (2020) · cites this paper as Taylor and Machado-Moreira 2013
Experimental — accuracy not yet measuredThe source backs part of the claim, not all of it — or backs it for a different population, condition or comparison.
In the citing paper
“This is especially relevant in athletics, where proper fluid replacement during practice and competition is critical for ensuring physical and mental well-being (43, 44).”
From Regional and correlative sweat analysis using high-throughput microfluidic sensing patches toward decoding sweat (2019) · cites this paper as [44]
Experimental — accuracy not yet measuredThe source backs part of the claim, not all of it — or backs it for a different population, condition or comparison.
In the citing paper
“Maintaining fluid/electrolyte balance is essential for healthy vital functions.”
From Regional and correlative sweat analysis using high-throughput microfluidic sensing patches toward decoding sweat (2019) · cites this paper as [44]
Experimental — accuracy not yet measured
8 more claims about this paper
Create a free account to see every claim other papers make about this one.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
(1992) · Applied Ergonomics · doi:10.1016/0003-6870(92)90318-p · Cited by 5,737
Åstrand, P. O., & Ryhming, I. (1954) · Journal of Applied Physiology · doi:10.1152/jappl.1954.7.2.218 · Cited by 1,558 · cited 1×
“exercise-induced increments in heart rate [265] and that”
BackgroundScheuplein, R. J., & Blank, I. H. (1971) · Physiological Reviews · doi:10.1152/physrev.1971.51.4.702 · Cited by 1,398 · cited 3×
“Indeed, the steady-state water flux through the skin from the abdomen is about 10% of that observed from the plantar surface of the foot and 30% of that from the palm [27].”
BackgroundInfluentialHuman biology: A guide to field methods;
Weiner, J. S., & Lourie, J. A. (1969) · Medical Entomology and Zoology · Cited by 981
Advances in Comparative and Environmental Physiology: Volume 7
Houlihan, D. F., Livingstone, D. R., & Lee, R. F. (1991) · Advances in Comparative and Environmental Physiology · doi:10.1007/978-3-642-75897-3 · Cited by 738
Biology of sweat glands and their disorders. I. Normal sweat gland function
Sato, K., Kang, W. H., Saga, K., & Sato, K. T. (1989) · Journal of the American Academy of Dermatology · doi:10.1016/s0190-9622(89)70063-3 · Cited by 717 · cited 2×
“A discontinuous layer of myoepithelial cells separates the epithelial cells from the basement membrane [9,53,55].”
BackgroundGeneral Characteristics of Sympathetic Activity in Human Skin Nerves
Hagbarth, K. ‐., Hallin, R. G., Hongell, A., Torebjörk, H. E., & Wallin, B. G. (1972) · Acta Physiologica Scandinavica · doi:10.1111/j.1748-1716.1972.tb05167.x · Cited by 688
Physiological and behavioral temperature regulation
Hardy, J. D., Gagge, A. P., & Stolwijk, J. A. J. (1970) · Thomas eBooks · Cited by 668
Malaparte, C. (1988) · Cited by 601
Esophageal, rectal, and muscle temperature during exercise
Saltin, B., & Hermansen, L. (1966) · Journal of Applied Physiology · doi:10.1152/jappl.1966.21.6.1757 · Cited by 557 · cited 1×
“For instance, it is well known that oxygen consumption increases linearly with exercise-induced increments in heart rate [265] and that body core temperature is intrinsically linked with oxygen consumption [266].”
Background
Research works printed but not linked: 27
- Kuno Y: Human Perspiration. 1956, Springfield: C.C. Thomas
- Quincy J: Medicina Statica: Being the Aphorisms of Sanctorius. 1712, London: Printed for William Newton
- Wendt A: Über die menschliche Epidermis. Müller Arch. 1834, 278-291.
- Krause KFT: Handwörterbuch der Physiologie. Edited by: Braunschweig WR. 1844, Germany: F. Vieweg and Sohn, 108-186. Die Haut, 2,
- Ranvier L-A: Le mécanisme de la sécrétion. Schwalbe Jahresber. 1887, 16: 388-392.
- Schiefferdecker P: Die Hautdrüsen des Menschen und der Säugetiere, ihre biologische und rassenanatomische Bedeutung, sowie die Muscularis sexualis. Biol Zentralblatt. 1917, 37: 534-562.
- Sanctorius S: De statica medicina. 1614
- MacPherson RK, Newling PSB: Salt concentration and rate of evaporation of sweat. J Physiol. 1954, 123: 74P-
- Benedict FG, Benedict CG: Perspiratio insensibilis: ihr Wesen und ihre Ursachen. Biochem Ztschr. 1927, 186: 278-312.
- Buettner KJK, Odland GF: Physical factors of the skin barrier layer and water diffusion into human skin. Fed Proc. 1957, 16: 18-
- Galeotti G, Macri NM: Über die Perspiratio insensibilis unter normalen und pathologischen Bedingungen. Biochem Z. 1914, 67: 472-482.
- Ikeuchi K, Kuno Y: On the regional differences of the perspiration on the surface of the human body. J Orient Med. 1927, 7: 106-107.
- Renaut J: Dispositif anatomique et mécanisme de l'excrétion des glandes sudoripares. Ann Dermatol. 1894, 5: 1101-1104.
- Ogata K: Functional variations in human sweat glands, with remarks upon the regional differences of the amount of sweat. J Oriental Med. 1935, 23: 98-101.
- Szabo G: The number of eccrine sweat glands in human skin. Adv Biol Skin. 1962, 3: 1-5.
- Ojikutu RO: Die Rolle von Hautpigment und Schweissdrusen in der Klima-anpassung des Menschen. Homo. 1965, 16: 77-95.
- Morimoto T: Sweat secretion. The Physiology and Pharmacology of the Skin. Edited by: Jarrett A. 1978, London: Academic Press, 1611-1621.
- Eichna LW, Bean WB, Ashe WF, Nelson N: Performance in relation to environmental temperature. Bull Johns Hopkins Hosp. 1945, 76: 25-58.
- Machado-Moreira CA, Barry RJ, Vosselman MJ, Taylor NAS: Thermal and non-thermal sweating: what you see is not necessarily what you get. J Physiol Sci. 2009, 59 (Suppl. 1): 167-
- Féré C: Note sur des modifications de la résistance électrique sous l'influence des excitations sensorialles et des emotions. CR Séances Soc Biol Fil. 1888, 5: 217-219.
- Yen TJ: A new method for the measurement of the secretion of a single sweat gland. Med J Southern Manchuria. 1924, 12: 507-
- Ichihashi T: Method of observing sweat drops on the skin covered with oil, and several observations with this method. J Orient Med. 1936, 25: 107-108.
- Werner J, Graener R, Heising M, Tutughamiarsa TB: A microprocessor-supported device for the measurement of human sweat rate. Med Biol Engin Comp. 1985, 23: 1037-1038.
- Oehler J: Über die Hauttemperatur der gesunden Menschen. Deutsches Arch f klin Med. 1904, 80: 245-262.
- Takahara K: Observations on the discharge of sweat from a single sweat gland. J Oriental Med. 1936, 24: 4-
- van Beaumont W, Bullard RW, Banerjee MR: Observations on human sweating by resistance hygrometry. Dermatol Digest. 1966, 75-87.
- Gordon CJ: Non-thermoregulatory factors in humans during exercise and rest: influences on thermoeffector function. 2010, PhD thesis. University of Wollongong, Department of Biomedical Science
Cited by
Items 201–300 of 509
Taylor, N. A. S., Lee, J., Kim, S., & Notley, S. R. (2021) · Journal of Thermal Biology · doi:10.1016/j.jtherbio.2021.102858 · Cited by 20
Self-citationNormative data on regional sweat-sodium concentrations of professional male team-sport athletes
Ranchordas, M. K., Tiller, N. B., Ramchandani, G., Jutley, R., Blow, A., Tye, J., & Drury, B. (2017) · Journal of the International Society of Sports Nutrition · doi:10.1186/s12970-017-0197-4 · Cited by 23
“First, it is well-established that there exist regional differences in sweat-electrolyte content [35], and regional sweat collection techniques have been shown to overestimate sweat-sodium concentrations when compared to wholebody values [36–38].”
Amano, T., Hirose, M., Konishi, K., Gerrett, N., Ueda, H., Kondo, N., & Inoue, Y. (2017) · European Journal of Applied Physiology · doi:10.1007/s00421-017-3619-8 · Cited by 19
Relf, R., Willmott, A., Flint, M. S., Beale, L., & Maxwell, N. (2019) · Journal of Thermal Biology · doi:10.1016/j.jtherbio.2018.12.019 · Cited by 19
“Humans have a substantial and flexible capacity for the active secretion of sweat (Taylor and Machado-Moreira, 2013), which can be assessed using whole-body techniques or methods localised to specific anatomical locations.”
BackgroundNotley, S. R., Mitchell, D., & Taylor, N. A. S. (2023) · European Journal of Applied Physiology · doi:10.1007/s00421-023-05276-3 · Cited by 21
Self-citationEffects of individual characteristics and local body functions on sweating response: A review
Niu, Z., & Tomonobu, G. O. T. O. (2024) · International Journal of Biometeorology · doi:10.1007/s00484-024-02758-7 · Cited by 24
“In contrast, Taylor and Machado-Moreira (2013) are the only authors to conduct a comprehensive review to date.”
BackgroundTaylor, N. A. S., & Gordon, C. J. (2019) · Journal of Thermal Biology · doi:10.1016/j.jtherbio.2019.08.003 · Cited by 21
Self-citationZooming in across the Skin: A Macro-to-Molecular Panorama
Deniz, A. A. H., Abdik, E. A., Abdik, H., Aydın, S., Şahin, F., & Taşlı, P. N. (2019) · Advances in experimental medicine and biology · doi:10.1007/5584_2019_442 · Cited by 19
Upasham, S., Osborne, O., & Prasad, S. (2021) · RSC Advances · doi:10.1039/d0ra10561a · Cited by 19
Comparison of density and output of sweat gland in tropical Africans and temperate Koreans
Lee, J., & Shin, Y. (2017) · Autonomic Neuroscience · doi:10.1016/j.autneu.2017.05.004 · Cited by 20
“…the forehead (0.99 mg/cm2/ min), dorsal fingers (0.62 mg/cm2/min), and upper back (0.59 mg/ cm2/min) of a typical person generally displays the highest sweat rates, while the medial thighs and anterior legs display the lowest sweat rate (both 0.12 mg/cm2/min) (Taylor and Machado-Moreira, 2013).”
InfluentialTaylor, N. A. S., Nykvist, Å., Powers, N., & Caldwell, J. N. (2019) · Journal of Thermal Biology · doi:10.1016/j.jtherbio.2019.05.001 · Cited by 18
Self-citationIn vivo assessments of microneedle arrays and iontophoresis of pilocarpine in human palmar sweating
Amano, T., Fujii, N., Quan, Y., Kenny, G. P., Kondo, N., Yamashita, H., & Inoue, Y. (2023) · Journal of Controlled Release · doi:10.1016/j.jconrel.2023.04.044 · Cited by 18
An Assistive Magnetic Skin System: Enabling Technology for Quadriplegics
Almansouri, A. S., Upadhyaya, L., Nunes, S. P., Salama, K. N., & Kosel, J. (2020) · Advanced Engineering Materials · doi:10.1002/adem.202000944 · Cited by 19
Sunscreen formulations do not interfere with sweat cooling during exercise
Ou‐Yang, H., Meyer, K., Houser, T., & Grove, G. L. (2017) · International Journal of Cosmetic Science · doi:10.1111/ics.12440 · Cited by 18
“With the diameter of sweat ducts on skin surface being about 60–80 lm [4], this corresponds to a flow rate of about 100 mg cm 2 min 1 inside the sweat pores.”
BackgroundEnhancing the sweat resistance of sunscreens
Keshavarzi, F., Knudsen, N. Ø., Komjani, N. M., Ebbesen, M. F., Brewer, J. R., Jafarzadeh, S., & Thormann, E. (2021) · Skin Research and Technology · doi:10.1111/srt.13115 · Cited by 19
Chen, B., Qian, Z., Song, G., Zhuang, Z., Sun, X., Ma, S., Liang, Y., Ren, L., & Ren, L. (2023) · Chemical Engineering Journal · doi:10.1016/j.cej.2023.142350 · Cited by 18
Sustainable Nanofibril Interfaces for Strain‐Resilient and Multimodal Porous Bioelectronics
Zhao, G., Chen, Z., Wang, S., Chen, S., Zhang, F., Andrabi, S. M., Xu, Y., Ouyang, Q., Busquets, M. E., Qian, X., et al. (2024) · Advanced Materials · doi:10.1002/adma.202411587 · Cited by 20
Iftekhar, A. T., Ho, J. C.-T., Mellinger, A., & Kaya, T. (2017) · Journal of Applied Physics · doi:10.1063/1.4977998 · Cited by 17
Grandjean, D., Gallet, C., Julien, C., Sarkis, R., Muzzin, Q., Roger, V., Roisse, D., Dirn, N., Levert, C., Breton, E., et al. (2022) · PLoS ONE · doi:10.1371/journal.pone.0262631 · Cited by 19
Wearable Sweat Management Technologies
Wei, L., Li, Z., Dai, Z., Ding, L., Wei, H., Li, J., Zhu, H., & Zhu, Y. (2024) · Advanced Materials Technologies · doi:10.1002/admt.202301812 · Cited by 21
Vittrant, B., Ayoub, H., & Brunswick, P. (2024) · Frontiers in Neuroanatomy · doi:10.3389/fnana.2024.1454095 · Cited by 16
Discretised microfluidics for noninvasive health monitoring using sweat sensing
Moonen, E. J. M., Verberne, W., Pelssers, E., Heikenfeld, J. C., & den Toonder, J. M. J. (2024) · Lab on a Chip · doi:10.1039/d4lc00763h · Cited by 18
A Touch Enabled Hemodynamic and Metabolic Monitor
Djassemi, O., Saha, T., Nandhakumar, P., Khan, M. I., Fishman, H., Earney, S., Moonla, C., Xu, Y., Thai, H., Morales‐Fermin, S., et al. (2025) · Advanced Science · doi:10.1002/advs.202502138 · Cited by 18
Amano, T., Okushima, D., Breese, B. C., Bailey, S. J., Koga, S., & Kondo, N. (2018) · European Journal of Applied Physiology · doi:10.1007/s00421-018-3889-9 · Cited by 17
“However, it is important to note the large inter-regional differences in local SR and skin blood flow (SkBF) previously reported across human skin (Havenith et al. 2008; Smith and Havenith 2011; Taylor and Machado-Moreira 2013; Kuno 1956; Hertzman and Randall 1948).”
Schwarck, J. B., Burdon, C. A., Taylor, E., Peoples, G. E., Machado-Moreira, C. A., & Taylor, N. A. S. (2019) · Journal of Thermal Biology · doi:10.1016/j.jtherbio.2019.04.017 · Cited by 16
Self-citationSeok, M., Yoon, S., Kim, M., & Cho, Y.-H. (2021) · Nanoscale Advances · doi:10.1039/d1na00180a · Cited by 16
A One-Dollar, Disposable, Paper-Based Microfluidic Chip for Real-Time Monitoring of Sweat Rate
Wang, H., Xu, K., Xu, H., Huang, A., Fang, Z., Zhang, Y., Wang, Z., Lu, K., Wan, F., Bai, Z., et al. (2022) · Micromachines · doi:10.3390/mi13030414 · Cited by 17
“Therefore, the sweat rate of the left forearm was much lower than that of the forehead and greater than that of the nape of the neck for regional variations in human eccrine sweat gland density and local sweat secretion rates during the thermal loading in exercising individuals [44].”
BackgroundTopham, T. H., Smallcombe, J. W., Clark, B., Brown, H. A., Telford, R. D., Jay, O., & Périard, J. D. (2022) · American Journal of Physiology-Regulatory, Integrative and Comparative Physiology · doi:10.1152/ajpregu.00328.2021 · Cited by 17
Machado-Moreira, C. A., & Taylor, N. A. S. (2017) · Journal of Thermal Biology · doi:10.1016/j.jtherbio.2017.03.002 · Cited by 16
Self-citationEffect of aqueous dilution on the absorption of the nerve agent VX through skin in vitro
Dalton, C. H., Graham, S., & Jenner, J. (2018) · Toxicology in Vitro · doi:10.1016/j.tiv.2018.08.003 · Cited by 16
Developments in silicone technology for use in stoma care
Swift, T., Westgate, G. E., Onselen, J. V., & Lee, S. (2020) · British Journal of Nursing · doi:10.12968/bjon.2020.29.6.s6 · Cited by 17
Tanaka, K., Nakamura, K., & Katafuchi, T. (2014) · Acta Astronautica · doi:10.1016/j.actaastro.2014.08.009 · Cited by 16
Notley, S. R., Mitchell, D., & Taylor, N. A. S. (2023) · European Journal of Applied Physiology · doi:10.1007/s00421-023-05284-3 · Cited by 16
Self-citationKeefe, M. S., Benjamin, C. L., Casa, D. J., & Sekiguchi, Y. (2024) · Applied Sciences · doi:10.3390/app142210103 · Cited by 18
Noninvasive profiling of sweat‐derived lipid mediators for cutaneous research
Agrawal, K., Sivamani, R. K., & Newman, J. W. I. (2018) · Skin Research and Technology · doi:10.1111/srt.12617 · Cited by 17
Don’t Sweat It: The Quest for Wearable Stress Sensors
Bandodkar, A. J., Ghaffari, R., & Rogers, J. A. (2020) · Matter · doi:10.1016/j.matt.2020.03.004 · Cited by 15
“human body produces a considerable amount of this relatively underexplored class of biofluid.(9) More importantly, sweat contains a rich mixture of important biochemical markers,(10) including cortisol,(11) that can yield insights into health status.”
BackgroundNishioka, Y., Nagano, K., Koga, Y., Okada, Y., Mori, I., Hayase, A., Mori, T., & Manabe, K. (2021) · Scientific Reports · doi:10.1038/s41598-021-98042-4 · Cited by 16
Hodges, G. J., McGarr, G. W., Mallette, M. M., Pozzi, A. T. D., & Cheung, S. S. (2015) · Microvascular Research · doi:10.1016/j.mvr.2015.12.004 · Cited by 15
Seasonal variations in the skin parameters of Caucasian women from Central Europe
Dolečková, I., Čápová, A., Machková, L., Moravčíková, S., Marešová, M., & Velebný, V. (2020) · Skin Research and Technology · doi:10.1111/srt.12951 · Cited by 18
Construction of Flexible Kaolin/Chitin Composite Aerogels and Their Properties
He, M., Huang, Y., Cui, Z., Cheng, Z., Cao, W., Wang, G., Yao, W., & Feng, M. (2026) · Gels · doi:10.3390/gels12010076 · Cited by 14
“All the composite aerogels exhibited WVTR values that significantly exceeded the average water vapor evaporation rate of human skin, a feature that is crucial for effective wound management by reducing the risk of maceration and facilitating healing [36,37].”
Nabeel, M. I., Jaber, H., Taieh, N. K., Li, Y., Gou, G., & Kovács, T. A. (2026) · Sensors and Actuators A Physical · doi:10.1016/j.sna.2026.117723 · Cited by 18
A versatile artificial skin platform for sweat sensor development
Moonen, E. J. M., Islam, T. U., van Kemenade, S., Pelssers, E., Heikenfeld, J. C., & den Toonder, J. M. J. (2023) · Lab on a Chip · doi:10.1039/d3lc00109a · Cited by 16
Dyson, E., Sikkink, S. K., Nocita, D., Twigg, P. C., Westgate, G. E., & Swift, T. (2023) · ACS Applied Bio Materials · doi:10.1021/acsabm.3c00874 · Cited by 14
Coşkun, A., Savaş, İ. N., Can, O., & Lippi, G. (2025) · Critical Reviews in Clinical Laboratory Sciences · doi:10.1080/10408363.2025.2453152 · Cited by 16
“The composition of sweat also varies due to other factors including changes in sweat gland activity, individual metabolic rates, reabsorption of electrolytes by sweat glands and also sample collection methods [41,94].”
Relf, R. L., Eichhorn, G., Waldock, K., Flint, M. S., Beale, L., & Maxwell, N. (2020) · Journal of Thermal Biology · doi:10.1016/j.jtherbio.2020.102577 · Cited by 15
Noninvasive Epidermal Metabolite Profiling
Stoffers, K. M., Cronkright, A. A., Huggins, G. S., & Baleja, J. (2020) · Analytical Chemistry · doi:10.1021/acs.analchem.0c02274 · Cited by 14
Churcher, N. K. M., Greyling, C. F., Upasham, S., Lin, K., Rice, P., Pali, M. L., Spiro, J. C. K., & Prasad, S. (2022) · Biosensors and Bioelectronics X · doi:10.1016/j.biosx.2022.100145 · Cited by 16
Military Clothing and Protective Material: Protection at the Limits of Physiological Regulation
Taylor, N. A. S., & Patterson, M. J. (2014) · Studies in mechanobiology, tissue engineering and biomaterials · doi:10.1007/8415_2014_181 · Cited by 17
“diffusing down the vapour pressure gradient within the stratum corneum [74] at a whole-body rate of 26–43 g h [81], then the trapped boundary layer also becomes progressively more humid.”
BackgroundSelf-citationFrequency of the resonance of the human sweat duct in a normal mode of operation
Tripathi, S. R., Ishai, P. B., & Kawase, K. (2018) · Biomedical Optics Express · doi:10.1364/boe.9.001301 · Cited by 15
Thermal sensitivity mapping - warmth and cold detection thresholds of the human torso
Schmidt, D., Schlee, G., Milani, T. L., & Germano, A. M. C. (2020) · Journal of Thermal Biology · doi:10.1016/j.jtherbio.2020.102718 · Cited by 15
Thermal signatures of liquid droplets on a skin induced by emotional sweating
Koroteeva, E. Y., & Bashkatov, A. A. (2021) · Quantitative InfraRed Thermography Journal · doi:10.1080/17686733.2020.1846113 · Cited by 15
“This agrees with the general physiological observation that palmar sweat gland bodies have more than 4-times lower secretory capacity than those on a face [16].”
BackgroundSweat evaporation in humans: A molecular and thermodynamic perspective
Ashworth, E. T. (2025) · Experimental Physiology · doi:10.1113/ep093011 · Cited by 15
“Sweat production by eccrine glands forms the foundation of human evaporative cooling (Taylor & Machado-Moreira, 2013).”
InfluentialZhang, Y., Zhang, S., Yang, Y., Tao, L., Yu, F., Song, C., Guo, K., Zhu, J., Lin, Y., Yang, F., et al. (2026) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.2532127123 · Cited by 19
Recent Advances in Wearable Sweat Sensor Development
Zhang, T., Kabandana, G. K. M., Terrell, J. A., Chen, H., & Chen, C. (2025) · Wiley Interdisciplinary Reviews Nanomedicine and Nanobiotechnology · doi:10.1002/wnan.70006 · Cited by 15
Exertional heat stress and sodium balance: Leaders, followers, and adaptations
McCubbin, A. J. (2021) · Autonomic Neuroscience · doi:10.1016/j.autneu.2021.102863 · Cited by 13
Baroreceptor unloading does not limit forearm sweat rate during severe passive heat stress
Schlader, Z. J., Gagnon, D., Lucas, R. A. I., Pearson, J., & Crandall, C. G. (2014) · Journal of Applied Physiology · doi:10.1152/japplphysiol.00800.2014 · Cited by 13
“That said, although forearm sweat rate is representative of other nonglabrous areas during passive heating (33) and it responds to nonthermal stimuli similarly to other nonglabrous skin sites (25), we cannot rule out the possibility that sweat rate in other areas of the body increased during the baroreceptor reloading…”
BackgroundSpathmann, O., Zang, M., Streckert, J. R., Hansen, V., Saviz, M., Fiedler, T. M., Statnikov, K., Pfeiffer, U. R., & Clemens, M. (2015) · IEEE Transactions on Terahertz Science and Technology · doi:10.1109/tthz.2015.2476962 · Cited by 13
“2 mm [38].”
Morphological and Physiological Considerations for the Modelling of Human Heat Loss
Taylor, N. A. S., & Notley, S. R. (2018) · Wiley eBooks · doi:10.1002/9781119127420.ch22 · Cited by 15
Self-citationMulti-sensing of fragile persons for risk situation detection: devices, methods, challenges
Yebda, T., Benois‐Pineau, J., Amieva, H., & Frolicher, B. (2019) · International Workshop on Content-Based Multimedia Indexing (CBMI) · doi:10.1109/cbmi.2019.8877476 · Cited by 13
“According to numerous studies [19], the optimal place to take measurements of electro-dermal activity is the palm or fingers of one hand for the high concentration of eccrine glands responsible for sweat secretions from the human body.”
BackgroundRecent Impact of Microfluidics on Skin Models for Perspiration Simulation
Rabost-Garcia, G., Farré‐Lladós, J., & Casals‐Terré, J. (2021) · Membranes · doi:10.3390/membranes11020150 · Cited by 13
“Yet, these devices are currently still at the research phase and human validation is both time- and resource-consuming, and has a high degree of variability [30], which limits the comparison between studies.”
BackgroundCaldwell, J. N., & Taylor, N. A. S. (2014) · Physiological Measurement · doi:10.1088/0967-3334/35/9/1781 · Cited by 13
Self-citationGil-Calvo, M., Jimenez‐Perez, I., Pérez‐Soriano, P., & Priego‐Quesada, J. I. (2016) · Biological and medical physics, biomedical engineering · doi:10.1007/978-3-319-47410-6_10 · Cited by 14
Rutherford, M. M., Akerman, A. P., Notley, S. R., Meade, R. D., Schmidt, M. D., & Kenny, G. P. (2020) · Experimental Physiology · doi:10.1113/ep089074 · Cited by 15
“Although a variety ofmethods exist, the ventilated capsule technique is preferred for mechanistic research (Meade et al., 2016; Taylor & Machado-Moreira, 2013), Experimental Physiology.”
Lin, F., Anaya, D. V., Gong, S. P., Yap, L. W., Yan, L., Yong, Z., & Cheng, W. (2024) · ACS Sensors · doi:10.1021/acssensors.4c01635 · Cited by 14
Wearable Devices for Biofluid Monitoring in a Body: from Lab to Commercialization
Yang, Y. J., Lee, S. G., & Kim, T. (2024) · Korean Journal of Chemical Engineering · doi:10.1007/s11814-024-00295-y · Cited by 15
Revisiting regional variation in the age‐related reduction in sweat rate during passive heat stress
Schmidt, M. D., Notley, S. R., Meade, R. D., Akerman, A. P., Rutherford, M. M., & Kenny, G. P. (2022) · Physiological Reports · doi:10.14814/phy2.15250 · Cited by 15
Real-time smart multisensing wearable platform for monitoring sweat biomarkers during exercise
Lafaye, C., Rovira, M., Demuru, S., Wang, S., Kim, J., Kunnel, B. P., Besson, C., Fernández‐Sánchez, C., Serra-Graells, F., Margarit, J. M., et al. (2022) · IEEE Biomedical Circuits and Systems Conference (BioCAS) · doi:10.1109/biocas54905.2022.9948565 · Cited by 14
“using the absorbent patch technique [16] from the forehead, arm (tricep), and mid back.”
MethodImpacts of Skin Eccrine Glands on the Measured Values of Transepidermal Water Loss
Schwab, H., Flora, J., & MAYROVITZ, H. N. (2022) · Cureus · doi:10.7759/cureus.32266 · Cited by 14
“Pre- and post-exercise measurements have been used to evaluate the effects of eccrine gland sweat production on TEWL [17,29,38].”
BackgroundMethodResultInfluentialNotley, S. R., Mitchell, D., & Taylor, N. A. S. (2023) · European Journal of Applied Physiology · doi:10.1007/s00421-023-05262-9 · Cited by 13
Self-citationJung, D., Kim, Y.-B., Lee, J., Muhamed, A. M. C., & Lee, J. (2018) · European Journal of Applied Physiology · doi:10.1007/s00421-018-3988-7 · Cited by 12
Kuklane, K., Eggeling, J., Kemmeren, M., & Heus, R. (2022) · Biology · doi:10.3390/biology11121813 · Cited by 14
“…during different work tasks, body internal heat distribution and areas for heat loss [28,29], protection criteria of vital regions, sweating patterns [30–32], but also freedom of motion, may set the specific demands on the need of regional evaporative resistance [33] and clothing insulation [34].”
Gopinath, H., Karthiga, R., & Karthikeyan, K. (2018) · International Journal of Dermatology · doi:10.1111/ijd.14088 · Cited by 12
The effects of exercise and passive heating on the sweat glands ion reabsorption rates
Gerrett, N., Amano, T., Inoue, Y., Havenith, G., & Kondo, N. (2018) · Physiological Reports · doi:10.14814/phy2.13619 · Cited by 11
Water vapor permeation through topical films on a moisture‐releasing skin Model
Keshavarzi, F., Moghaddam, S. Z., Pedersen, M. B., Knudsen, N. Ø., Jafarzadeh, S., & Thormann, E. (2020) · Skin Research and Technology · doi:10.1111/srt.12926 · Cited by 13
On the Breathability of Epidermal Polymeric-Printed Tattoo Electrodes
Galliani, M., Greco, F., Ismailova, E., & Ferrari, L. M. (2025) · ACS Applied Electronic Materials · doi:10.1021/acsaelm.4c01902 · Cited by 11
Gao, H., & Ghahramani, A. (2025) · Energy and Buildings · doi:10.1016/j.enbuild.2025.116690 · Cited by 13
Ahmed, T., Gao, Y., So, M. Y., Zhang, J., Liu, X., Toki, G. F. I., Lü, J., Chen, T., & Xu, B. (2026) · Small · doi:10.1002/smll.202514093 · Cited by 12
Chen, H., Xu, S., Liu, H., Liu, C., Liu, H., Chen, J., Huang, H., Gong, H., Wu, J., Tang, H., et al. (2023) · Advanced Functional Materials · doi:10.1002/adfm.202309798 · Cited by 14
Michaels, B., Ayers, T., Brooks-McLaughlin, J., McLaughlin, R. J., Sandoval-Warren, K., Schlenker, C., Ronaldson, L., & Ardagh, S. (2024) · Journal of Food Protection · doi:10.1016/j.jfp.2024.100283 · Cited by 13
Yokoya, M., & Higuchi, Y. (2016) · American Journal of Human Biology · doi:10.1002/ajhb.22867 · Cited by 11
Dilation of Multiple Eccrine Ducts as a Highly Specific Marker for Cicatricial Alopecia
Tan, T. L., Doytcheva, K., Guitart, J., Gerami, P., & Yazdan, P. (2019) · American Journal of Dermatopathology · doi:10.1097/dad.0000000000001396 · Cited by 11
In vitro skin model for characterization of sunscreen substantivity upon perspiration
Keshavarzi, F., Knudsen, N. Ø., Brewer, J. R., Ebbesen, M. F., Komjani, N. M., Moghaddam, S. Z., Jafarzadeh, S., & Thormann, E. (2021) · International Journal of Cosmetic Science · doi:10.1111/ics.12703 · Cited by 11
“31 μL min−1 cm−2 were selected based on the sweat rates on untreated human foreheads in two different conditions of moderate and heavy sweating [46].”
BackgroundMethodNam, S., & Kuchenbecker, K. J. (2021) · IEEE Transactions on Haptics · doi:10.1109/toh.2021.3077549 · Cited by 12
“It is known that sweat gland density in the finger’s volar region is the second-highest in the body (after the toe) [32]; the permeated liquid may allow deformations of the surrounding solid tissue mainly in the dermis layer.”
BackgroundA Bioinspired Sweat‐Drainable Janus Electrophysiological Electrode for Scientific Sports Training
Li, P., Bao, Y., Chen, B., Liu, X., Yang, H., Li, Q., Chen, T., Fan, J., Hu, C., & Ling, Y. (2022) · Advanced Materials Technologies · doi:10.1002/admt.202200040 · Cited by 11
de Rome, L., Taylor, E., Croft, R. J., Brown, J. K., Fitzharris, M., & Taylor, N. A. S. (2015) · Ergonomics · doi:10.1080/00140139.2015.1082632 · Cited by 11
“Whole-body sweat rate (Taylor and Machado-Moreira 2013), clothing moisture retention and evaporation rates were determined from gross body (wearing swimming costumes only), and clothing and equipment masses measured before and after each trial (fw-150 k, A&D scale, CA, USA: ±20 g).”
MethodSelf-citationEffects of stimulation technique, anatomical region, and time on human sweat lipid mediator profiles
Agrawal, K., Waller, J. D., Pedersen, T. L., & Newman, J. W. (2018) · Prostaglandins & Other Lipid Mediators · doi:10.1016/j.prostaglandins.2017.09.007 · Cited by 10
Lu, T., Fan, J., You, S., Adiraju, A., Guo, Y., Talbi, M., Jaradat, H., & Kanoun, O. (2025) · Emergent Materials · doi:10.1007/s42247-025-01279-2 · Cited by 10
“Its composition is closely related to blood and extracellular fluid [ 2], making it a valuable biological indicator for assessing physiological status [3].”
Orthogonal‐polarization‐gating optical coherence tomography for human sweat ducts in vivo
Li, D., Li, Z., Zhang, J., Li, K., Wu, S., He, Y., & Lin, Y. (2020) · Journal of Biophotonics · doi:10.1002/jbio.202000432 · Cited by 10
Meteier, Q., Capallera, M., de Salis, E., Widmer, M., Angelini, L., Khaled, O. A., Mugellini, E., & Sonderegger, A. (2022) · Physiological Reports · doi:10.14814/phy2.15229 · Cited by 11
Yang, H., Ding, H., Wei, W., Li, X.-F., Duan, X., Zhuang, C., Liu, W., Chen, S., & Wang, X. (2024) · Lab on a Chip · doi:10.1039/d3lc00791j · Cited by 10
Textile sorption and release of odorous volatile organic compounds from a synthetic sweat solution
McQueen, R. H., Eyres, G. T., & Laing, R. M. (2024) · Textile Research Journal · doi:10.1177/00405175241249462 · Cited by 10
Khan, Y., Mauriello, M. L., Nowruzi, P., Motani, A., Hon, G., Vitale, N. H., Li, J., Kim, J., Foudeh, A. M., Duvio, D., et al. (2024) · CHI Conference on Human Factors in Computing Systems · doi:10.1145/3613904.3643473 · Cited by 13
“We then proposed a combined wear index created using a weighting mechanism: ( We then visualize this data to explore tradeoffs between how and are utilized to suggest optimal wear locations.”
Li, H., Zhang, X., Zeng, S., Chen, L., Li, X., Lin, C., Zhang, M., Shu, S., Xie, S., He, Y., et al. (2014) · Acta Histochemica · doi:10.1016/j.acthis.2014.07.005 · Cited by 10
Burdon, C. A., Tagami, K., Park, J., Caldwell, J. N., & Taylor, N. A. S. (2017) · Journal of Thermal Biology · doi:10.1016/j.jtherbio.2017.02.015 · Cited by 10
Self-citationIitani, K., Naisierding, M., Toma, K., Arakawa, T., & Mitsubayashi, K. (2020) · The Analyst · doi:10.1039/c9an02089f · Cited by 11
Žnidarič, M., Škrinjar, D., & Kapel, A. (2023) · Biomolecules and Biomedicine · doi:10.17305/bb.2022.8561 · Cited by 11
“The average number of sweat glands per cm2 on male skin is 233 on the palms, 620 on the forearms, 360 on the forehead, 120 on the thighs, 497 on the sole, 155 on the dorsal side of the foot, and 57 on the shins [24, 25].”
BackgroundAn Artificial Sweating System for Sweat Sensor Testing Applications
Brueck, A., Bates, K. D., Wood, T., House, W., Martinez, Z., Peters, S., Root, B., Yelamarthi, K., & Kaya, T. (2019) · Electronics · doi:10.3390/electronics8060606 · Cited by 10
Sakhawoth, Y., Dupire, J., Léonforte, F., Chardon, M., Monti, F., Tabeling, P., Cabane, B., Botet, R. S., & Galey, J.-B. (2021) · Scientific Reports · doi:10.1038/s41598-021-85691-8 · Cited by 13
Suvi, S., Mooses, M., Timpmann, S., Medijainen, L., Narõškina, D., Unt, E., & Ööpik, V. (2018) · Applied Physiology, Nutrition, and Metabolism · doi:10.1139/apnm-2017-0584 · Cited by 11
“Compared with temperate environment, exercise in the heat places a higher demand on body’s thermoregulatory system and induces sweat losses that may reach 3–4 L·h‒1 in trained athletes (Taylor and Machado-Moreira 2013).”
BackgroundCan POPs be substantially popped out through sweat?
Imbeault, P., Ravanelli, N., & Chevrier, J. (2017) · Environment International · doi:10.1016/j.envint.2017.11.023 · Cited by 10
Metadata
- Authors
- Taylor, N. A., & Machado-Moreira, C. A.
- Affiliations
- University of Wollongong (AU)
- Corresponding author
- Taylor, Nigel AS
- ORCID
- Taylor, Nigel AS
- Venue
- Extreme Physiology & Medicine
- Published
- 2013-02-01
- Volume
- 2
- Issue
- 1
- Pages
- 4-4
- ISSN
- 2046-7648 (ISSN-L)
- PMC
- PMC3710196
- OpenAlex
- W2131490519
- Cited by
- 490
- References
- 260
- Citations by year
- 2026: 31 · 2025: 47 · 2024: 56 · 2023: 44 · 2022: 45 · 2021: 57 · 2020: 44 · 2019: 38 · 2018: 38 · 2017: 26 · 2016: 14 · 2015: 25 · 2014: 16 · 2013: 8
- FWCI
- 14.62
- Type
- journal article
- Language
- en
- Open access
- hybrid
- doi.org
- Licence
- cc-by
- creativecommons.org/licenses/by/2.0 (tdm)
- Locations
- Extreme Physiology & Medicine (publishedVersion, cc-by)
- Europe PMC (PubMed Central) (publishedVersion, cc-by)
- PubMed Central (publishedVersion, cc-by)
- PubMed (publishedVersion)
- Research Online (University of Wollongong) (submittedVersion)
- Figshare (submittedVersion)
- Funders
- Coordenação de Aperfeiçoamento de Pessoal de Nível Superior
- Ministério da Educação
- Defence Science and Technology Group
- Topics
- Health Sciences › Medicine › Physiology (medical) › Thermoregulation and physiological responses
- Health Sciences › Medicine › Physiology (medical) › Cardiovascular and exercise physiology
- Physical Sciences › Materials Science › Polymers and Plastics › Textile materials and evaluations
- Keywords
- transepidermal water loss, eccrine sweat glands, sweat gland density, insensible water loss, passive heating, exercise thermoregulation, evaporative cooling
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.