Microbial phylogenetic profiling with the Pacific Biosciences sequencing platform
Open accessThe DOI matches its Crossref record; 18 of the 18 references it cites were found in a registry or an index.
Abstract
High-throughput sequencing of 16S rRNA gene amplicons has revolutionized the capacity and depth of microbial community profiling. Several sequencing platforms are available, but most phylogenetic studies are performed on the 454-pyrosequencing platform because its longer reads can give finer phylogenetic resolution. The Pacific Biosciences (PacBio) sequencing platform is significantly less expensive per run, does not rely on amplification for library generation, and generates reads that are, on average, four times longer than those from 454 (C2 chemistry), but the resulting high error rates appear to preclude its use in phylogenetic profiling. Recently, however, the PacBio platform was used to characterize four electrosynthetic microbiomes to the genus-level for less than USD 1,000 through the use of PacBio's circular consensus sequence technology. Here, we describe in greater detail: 1) the output from successful 16S rRNA gene amplicon profiling with PacBio, 2) how the analysis was contingent upon several alterations to standard bioinformatic quality control workflows, and 3) the advantages and disadvantages of using the PacBio platform for community profiling.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
QIIME allows analysis of high-throughput community sequencing data
Caporaso, J. G., Kuczynski, J., Stombaugh, J., Bittinger, K., Bushman, F. D., Costello, E. K., Fierer, N., Peña, A. G., Goodrich, J. K., Gordon, J. I., et al. (2010) · Nature Methods · doi:10.1038/nmeth.f.303 · Cited by 34,887
Schloss, P. D., Westcott, S. L., Ryabin, T., Hall, J. R., Hartmann, M., Hollister, E. B., Lesniewski, R. A., Oakley, B. B., Parks, D. H., Robinson, C. J., et al. (2009) · Applied and Environmental Microbiology · doi:10.1128/aem.01541-09 · Cited by 19,549 · cited 1×
“As this workflow was not wholly sufficient for use with PacBio-generated data output [4], the necessary alterations are discussed further in the text, all of which can be executed with open-source software such as mothur [6] or QIIME [7].”
MethodUCHIME improves sensitivity and speed of chimera detection
Edgar, R. C., Haas, B. J., Clemente, J. C., Quince, C., & Knight, R. (2011) · Bioinformatics · doi:10.1093/bioinformatics/btr381 · Cited by 15,114
Reducing the Effects of PCR Amplification and Sequencing Artifacts on 16S rRNA-Based Studies
Schloss, P. D., Gevers, D., & Westcott, S. L. (2011) · PLoS ONE · doi:10.1371/journal.pone.0027310 · Cited by 2,112 · cited 2×
“Illumina and 454 have low error rates, but the errors are positional (they increase distally, with guanine-cytosine (GC) content, or with homopolymers) [8,9,15].”
BackgroundDetermination of microbial diversity in environmental samples: pitfalls of PCR-based rRNA analysis
v. Wintzingerode, F. (1997) · FEMS Microbiology Reviews · doi:10.1016/s0168-6445(97)00057-0 · Cited by 2,063
Quail, M., Smith, M. E., Coupland, P., Otto, T. D., Harris, S. R., Connor, T. R., Bertoni, A., Swerdlow, H. P., & Gu, Y. (2012) · BMC Genomics · doi:10.1186/1471-2164-13-341 · Cited by 2,031 · cited 3×
“Illumina and 454 have low error rates, but the errors are positional (they increase distally, with guanine-cytosine (GC) content, or with homopolymers) [8,9,15].”
BackgroundComparison of Next-Generation Sequencing Systems
Liu, L., Li, Y., Li, S., Hu, N., He, Y., Pong, R., Lin, D., Lu, L., & Law, M. (2012) · Journal of Biomedicine and Biotechnology · doi:10.1155/2012/251364 · Cited by 1,533 · cited 1×
“), one sequencing platform may be more appropriate than another for phylogenetic profiling [1,12-15].”
BackgroundPerformance comparison of benchtop high-throughput sequencing platforms
Loman, N. J., Misra, R. V., Dallman, T. J., Constantinidou, C., Gharbia, S. E., Wain, J., & Pallen, M. J. (2012) · Nature Biotechnology · doi:10.1038/nbt.2198 · Cited by 1,337
Analyzing and minimizing PCR amplification bias in Illumina sequencing libraries
Aird, D., Ross, M. G., Chen, W.-S., Danielsson, M., Fennell, T., Russ, C., Jaffe, D. B., Nusbaum, C., & Gnirke, A. (2011) · Genome Biology · doi:10.1186/gb-2011-12-2-r18 · Cited by 1,174
Substantial biases in ultra-short read data sets from high-throughput DNA sequencing
Dohm, J. C., Lottaz, C., Borodina, T., & Himmelbauer, H. (2008) · Nucleic Acids Research · doi:10.1093/nar/gkn425 · Cited by 1,088
Hybrid error correction and de novo assembly of single-molecule sequencing reads
Koren, S., Schatz, M. C., Walenz, B. P., Martin, J., Howard, J. T., Ganapathy, G., Wang, Z., Rasko, D. A., McCombie, W. R., Jarvis, E. D., et al. (2012) · Nature Biotechnology · doi:10.1038/nbt.2280 · Cited by 1,011 · cited 1×
“Pacific Biosciences (PacBio) is a less expensive platform (per run) and produces much longer reads (3,000 to 15,000 bp [1]) without a library preparation amplification step, but a recent review found that PacBio was in theory the least suitable out of the major high-throughput sequencing platforms available for phylog…”
BackgroundField guide to next‐generation DNA sequencers
GLENN, T. C. (2011) · Molecular Ecology Resources · doi:10.1111/j.1755-0998.2011.03024.x · Cited by 940 · cited 1×
“), one sequencing platform may be more appropriate than another for phylogenetic profiling [1,12-15].”
BackgroundPCR Biases Distort Bacterial and Archaeal Community Structure in Pyrosequencing Datasets
Pinto, A. J., & Raskin, L. (2012) · PLoS ONE · doi:10.1371/journal.pone.0043093 · Cited by 443 · cited 1×
“Conversely, Ion Torrent, Illumina, and 454 all have a noticeable GC bias [15-17], but Aird et al.”
BackgroundHigh-throughput bacterial genome sequencing: an embarrassment of choice, a world of opportunity
Loman, N. J., Constantinidou, C., Chan, J. Z. M., Halachev, M., Sergeant, M., Penn, C. W., Robinson, E. R., & Pallen, M. J. (2012) · Nature Reviews Microbiology · doi:10.1038/nrmicro2850 · Cited by 427 · cited 2×
“), one sequencing platform may be more appropriate than another for phylogenetic profiling [1,12-15].”
BackgroundElectrosynthesis of Commodity Chemicals by an Autotrophic Microbial Community
Marshall, C. W., Ross, D. E., Fichot, E. B., Norman, R. S., & May, H. D. (2012) · Applied and Environmental Microbiology · doi:10.1128/aem.02401-12 · Cited by 422 · cited 6×
“[4] contained a step to exclude chimeric sequences (UCHIME) [11].”
BackgroundMethodSelf-citationEvaluation of 16S rDNA-Based Community Profiling for Human Microbiome Research
Jumpstart Consortium Human Microbiome Project Data Generation Working Group (2012) · PLoS ONE · doi:10.1371/journal.pone.0039315 · Cited by 297
Pacific biosciences sequencing technology for genotyping and variation discovery in human data
Carneiro, M. O., Russ, C., Ross, M. G., Gabriel, S. B., Nusbaum, C., & DePristo, M. A. (2012) · BMC Genomics · doi:10.1186/1471-2164-13-375 · Cited by 254 · cited 4×
“Circular consensus sequencing (ccs) allows the polymerase to repeatedly replicate the circularized strand, producing one long read with randomly distributed errors [9].”
BackgroundInfluentialWerner, J. J., Zhou, D., Caporaso, J. G., Knight, R., & Angenent, L. T. (2012) · The ISME Journal · doi:10.1038/ismej.2011.186 · Cited by 123 · cited 1×
“5 billion reads per run) [1,2].”
Cited by
Kozich, J. J., Westcott, S. L., Baxter, N. T., Highlander, S. K., & Schloss, P. D. (2013) · Applied and Environmental Microbiology · doi:10.1128/aem.01043-13 · Cited by 7,112
The Madness of Microbiome: Attempting To Find Consensus “Best Practice” for 16S Microbiome Studies
Pollock, J., Glendinning, L., Wisedchanwet, T., & Watson, M. (2018) · Applied and Environmental Microbiology · doi:10.1128/aem.02627-17 · Cited by 575
proovread : large-scale high-accuracy PacBio correction through iterative short read consensus
Hackl, T., Hedrich, R., Schultz, J., & Förster, F. (2014) · Bioinformatics · doi:10.1093/bioinformatics/btu392 · Cited by 510
The Road to Metagenomics: From Microbiology to DNA Sequencing Technologies and Bioinformatics
Escobar-Zepeda, A., Vera-Ponce de León, A., & Sanchez-Flores, A. (2015) · Frontiers in Genetics · doi:10.3389/fgene.2015.00348 · Cited by 363
Shifting the paradigm from pathogens to pathobiome: new concepts in the light of meta-omics
Vayssier-Taussat, M., Albina, E., Citti, C., Cosson, J.-F., Jacques, M.-A., Lebrun, M.-H., Le Loir, Y., Ogliastro, M., Petit, M.-A., Roumagnac, P., et al. (2014) · Frontiers in Cellular and Infection Microbiology · doi:10.3389/fcimb.2014.00029 · Cited by 358
Metadata
- Authors
- Fichot, E. B., & Norman, R. S.
- Venue
- Microbiome
- Published
- 2013-03-04
- Volume
- 1
- Issue
- 1
- Pages
- 10-10
- ISSN
- 2049-2618 (ISSN-L)
- OpenAlex
- W2126132152
- Cited by
- 159
- References
- 18
- FWCI
- 9.01
- Type
- journal article
- Language
- en
- Open access
- gold
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.