The DOI matches its Crossref record; 9 of the 9 references it cites were found in a registry or an index.
Quantitative shear wave ultrasound elastography: initial experience in solid breast masses
Open accessAbstract
Introduction: Shear wave elastography is a new method of obtaining quantitative tissue elasticity data during breast ultrasound examinations. The aims of this study were (1) to determine the reproducibility of shear wave elastography (2) to correlate the elasticity values of a series of solid breast masses with histological findings and (3) to compare shear wave elastography with greyscale ultrasound for benign/malignant classification. Methods: Using the Aixplorer® ultrasound system (SuperSonic Imagine, Aix en Provence, France), 53 solid breast lesions were identified in 52 consecutive patients. Two orthogonal elastography images were obtained of each lesion. Observers noted the mean elasticity values in regions of interest (ROI) placed over the stiffest areas on the two elastography images and a mean value was calculated for each lesion. A sub-set of 15 patients had two elastography images obtained by an additional operator. Reproducibility of observations was assessed between (1) two observers analysing the same pair of images and (2) findings from two pairs of images of the same lesion taken by two different operators. All lesions were subjected to percutaneous biopsy. Elastography measurements were correlated with histology results. After preliminary experience with 10 patients a mean elasticity cut off value of 50 kilopascals (kPa) was selected for benign/malignant differentiation. Greyscale images were classified according to the American College of Radiology (ACR) Breast Imaging Reporting and Data System (BI-RADS). BI-RADS categories 1-3 were taken as benign while BI-RADS categories 4 and 5 were classified as malignant. Results: Twenty-three benign lesions and 30 cancers were diagnosed on histology. Measurement of mean elasticity yielded an intraclass correlation coefficient of 0.99 for two observers assessing the same pairs of elastography images. Analysis of images taken by two independent operators gave an intraclass correlation coefficient of 0.80. Shear wave elastography versus greyscale BI-RADS performance figures were sensitivity: 97% vs 87%, specificity: 83% vs 78%, positive predictive value (PPV): 88% vs 84%, negative predictive value (NPV): 95% vs 82% and accuracy: 91% vs 83% respectively. These differences were not statistically significant. Conclusions: Shear wave elastography gives quantitative and reproducible information on solid breast lesions with diagnostic accuracy at least as good as greyscale ultrasound with BI-RADS classification.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Supersonic shear imaging: a new technique for soft tissue elasticity mapping
Bercoff, J., Tanter, M., & Fink, M. (2004) · IEEE Transactions on Ultrasonics, Ferroelectrics and Frequency Control · doi:10.1109/tuffc.2004.1295425 · Cited by 2,476
Breast imaging reporting and data system (BI-RADS)
Liberman, L., & Menell, J. H. (2002) · Radiologic Clinics of North America · doi:10.1016/s0033-8389(01)00017-3 · Cited by 2,155
Solid breast nodules: use of sonography to distinguish between benign and malignant lesions.
Stavros, A. T., Thickman, D., Rapp, C. L., Dennis, M. A., Parker, S. H., & Sisney, G. A. (1995) · Radiology · doi:10.1148/radiology.196.1.7784555 · Cited by 1,780
Breast Disease: Clinical Application of US Elastography for Diagnosis
Itoh, A., Ueno, E., Tohno, E., Kamma, H., Takahashi, H., Shiina, T., Yamakawa, M., & Matsumura, T. (2006) · Radiology · doi:10.1148/radiol.2391041676 · Cited by 1,640
Tanter, M., Bercoff, J., Athanasiou, A., Deffieux, T., Gennisson, J.-L., Montaldo, G., Muller, M., Tardivon, A., & Fink, M. (2008) · Ultrasound in Medicine & Biology · doi:10.1016/j.ultrasmedbio.2008.02.002 · Cited by 733
Breast Lesions: Quantitative Elastography with Supersonic Shear Imaging—Preliminary Results
Athanasiou, A., Tardivon, A., Tanter, M., Sigal-Zafrani, B., Bercoff, J., Deffieux, T., Gennisson, J.-L., Fink, M., & Neuenschwander, S. (2010) · Radiology · doi:10.1148/radiol.10090385 · Cited by 519
Differentiating Benign from Malignant Solid Breast Masses with US Strain Imaging
Burnside, E. S., Hall, T. J., Sommer, A. M., Hesley, G. K., Sisney, G. A., Svensson, W. E., Fine, J. P., Jiang, J., & Hangiandreou, N. J. (2007) · Radiology · doi:10.1148/radiol.2452061805 · Cited by 296
Breast Lesions: Evaluation with US Strain Imaging–Clinical Experience of Multiple Observers
Regner, D. M., Hesley, G. K., Hangiandreou, N. J., Morton, M. J., Nordland, M. R., Meixner, D. D., Hall, T. J., Farrell, M. A., Mandrekar, J. N., Harmsen, W. S., et al. (2006) · Radiology · doi:10.1148/radiol.2381041336 · Cited by 175
Multiwave imaging and super resolution
Fink, M., & Tanter, M. (2010) · Physics Today · doi:10.1063/1.3326986 · Cited by 119
Cited by
Acerbi, I., Cassereau, L., Dean, I., Shi, Q., Au, A., Park, C., Chen, Y. Y., Liphardt, J., Hwang, E. S., & Weaver, V. M. (2015) · Integrative Biology · doi:10.1039/c5ib00040h · Cited by 1,059
Cosgrove, D., Piscaglia, F., Bamber, J., Bojunga, J., Correas, J.-M., Gilja, O., Klauser, A., Sporea, I., Calliada, F., Cantisani, V., et al. (2013) · Ultraschall in der Medizin - European Journal of Ultrasound · doi:10.1055/s-0033-1335375 · Cited by 955
WFUMB Guidelines and Recommendations for Clinical Use of Ultrasound Elastography: Part 3: Liver
Ferraioli, G., Filice, C., Castera, L., Choi, B. I., Sporea, I., Wilson, S. R., Cosgrove, D., Dietrich, C. F., Amy, D., Bamber, J. C., et al. (2015) · Ultrasound in Medicine & Biology · doi:10.1016/j.ultrasmedbio.2015.03.007 · Cited by 879
Ultrasound Imaging Technologies for Breast Cancer Detection and Management: A Review
Guo, R., Lu, G., Qin, B., & Fei, B. (2018) · Ultrasound in Medicine & Biology · doi:10.1016/j.ultrasmedbio.2017.09.012 · Cited by 542
WFUMB Guidelines and Recommendations for Clinical Use of Ultrasound Elastography: Part 2: Breast
Barr, R. G., Nakashima, K., Amy, D., Cosgrove, D., Farrokh, A., Schafer, F., Bamber, J. C., Castera, L., Choi, B. I., Chou, Y.-H., et al. (2015) · Ultrasound in Medicine & Biology · doi:10.1016/j.ultrasmedbio.2015.03.008 · Cited by 474
Shear wave elastography for breast masses is highly reproducible
the BE1 Study Group, Cosgrove, D. O., Berg, W. A., Doré, C. J., Skyba, D. M., Henry, J.-P., Gay, J., & Cohen-Bacrie, C. (2012) · European Radiology · doi:10.1007/s00330-011-2340-y · Cited by 406
Tissue mechanics modulate microRNA-dependent PTEN expression to regulate malignant progression
Mouw, J. K., Yui, Y., Damiano, L., Bainer, R. O., Lakins, J. N., Acerbi, I., Ou, G., Wijekoon, A. C., Levental, K. R., Gilbert, P. M., et al. (2014) · Nature Medicine · doi:10.1038/nm.3497 · Cited by 396
Chang, J. M., Moon, W. K., Cho, N., Yi, A., Koo, H. R., Han, W., Noh, D.-Y., Moon, H.-G., & Kim, S. J. (2011) · Breast Cancer Research and Treatment · doi:10.1007/s10549-011-1627-7 · Cited by 347
Evans, A., Whelehan, P., Thomson, K., McLean, D., Brauer, K., Purdie, C., Baker, L., Jordan, L., Rauchhaus, P., & Thompson, A. (2012) · Radiology · doi:10.1148/radiol.12111317 · Cited by 268
Self-citationDeep learning based classification of breast tumors with shear-wave elastography
Zhang, Q., Xiao, Y., Dai, W., Suo, J., Wang, C., Shi, J., & Zheng, H. (2016) · Ultrasonics · doi:10.1016/j.ultras.2016.08.004 · Cited by 240
Gioiella, F., Urciuolo, F., Imparato, G., Brancato, V., & Netti, P. A. (2016) · Advanced Healthcare Materials · doi:10.1002/adhm.201600772 · Cited by 112
Shear wave elastography of placenta: in vivo quantitation of placental elasticity in preeclampsia
Kilic, F., Kayadibi, Y., Yuksel, M. A., Adaletli, I., Ustabasioglu, F. E., Oncul, M., Madazli, R., Yilmaz, M. H., Mihmanli, I., & Kantarci, F. (2015) · Diagnostic and Interventional Radiology · doi:10.5152/dir.2014.14338 · Cited by 114
Metadata
- Authors
- Evans, A., Whelehan, P., Thomson, K., McLean, D., Brauer, K., Purdie, C., Jordan, L., Baker, L., & Thompson, A.
- Venue
- Breast Cancer Research
- Published
- 2010-12-01
- Volume
- 12
- Issue
- 6
- Pages
- R104-R104
- ISSN
- 1465-5411 (ISSN-L)
- 1465-542X
- OpenAlex
- W2141744828
- Cited by
- 450
- References
- 9
- FWCI
- 21.45
- Type
- journal article
- Language
- en
- Open access
- gold
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.