The DOI matches its Crossref record.
How can the response to volume expansion in patients with spontaneous respiratory movements be predicted?
Open accessAbstract
Introduction: The aim of the study was to evaluate the ability of different static and dynamic measurements of preload to predict fluid responsiveness in patients with spontaneous respiratory movements. Methods: The subjects were 21 critically ill patients with spontaneous breathing movements receiving mechanical ventilation with pressure support mode ( n = 9) or breathing through a face mask ( n = 12), and who required a fluid challenge. Complete hemodynamic measurements, including pulmonary artery occluded pressure (PAOP), right atrial pressure (RAP), pulse pressure variation (ΔPP) and inspiratory variation in RAP were obtained before and after fluid challenge. Fluid challenge consisted of boluses of either crystalloid or colloid until cardiac output reached a plateau. Receiver operating characteristics (ROC) curve analysis was used to evaluate the predictive value of the indices to the response to fluids, as defined by an increase in cardiac index of 15% or more. Results: Cardiac index increased from 3.0 (2.3 to 3.5) to 3.5 (3.0 to 3.9) l minute -1 m -2 (medians and 25th and 75th centiles), p < 0.05. At baseline, ΔPP varied between 0% and 49%. There were no significant differences in ΔPP, PAOP, RAP and inspiratory variation in RAP between fluid responders and non-responders. Fluid responsiveness was predicted better with static indices (ROC curve area ± SD: 0.73 ± 0.13 for PAOP, p < 0.05 vs ΔPP and 0.69 ± 0.12 for RAP, p = 0.054 compared with ΔPP) than with dynamic indices of preload (0.40 ± 0.13 for ΔPP and 0.53 ± 0.13 for inspiratory changes in RAP, p not significant compared with ΔPP). Conclusion: In patients with spontaneous respiratory movements, ΔPP and inspiratory changes in RAP failed to predict the response to volume expansion.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Cecconi, M., De Backer, D., Antonelli, M., Beale, R., Bakker, J., Hofer, C., Jaeschke, R., Mebazaa, A., Pinsky, M. R., Teboul, J. L., et al. (2014) · Intensive Care Medicine · doi:10.1007/s00134-014-3525-z · Cited by 1,767
Self-citationLamia, B., Ochagavia, A., Monnet, X., Chemla, D., Richard, C., & Teboul, J.-L. (2007) · Intensive Care Medicine · doi:10.1007/s00134-007-0646-7 · Cited by 393
Cavallaro, F., Sandroni, C., Marano, C., La Torre, G., Mannocci, A., De Waure, C., Bello, G., Maviglia, R., & Antonelli, M. (2010) · Intensive Care Medicine · doi:10.1007/s00134-010-1929-y · Cited by 386
Will This Hemodynamically Unstable Patient Respond to a Bolus of Intravenous Fluids?
Bentzer, P., Griesdale, D. E., Boyd, J., MacLean, K., Sirounis, D., & Ayas, N. T. (2016) · JAMA · doi:10.1001/jama.2016.12310 · Cited by 329
Monnet, X., & Teboul, J.-L. (2008) · Intensive Care Medicine · doi:10.1007/s00134-008-0994-y · Cited by 317
Monnet, X., Osman, D., Ridel, C., Lamia, B., Richard, C., & Teboul, J.-L. (2009) · Critical Care Medicine · doi:10.1097/ccm.0b013e3181968fe1 · Cited by 301
Should we measure the central venous pressure to guide fluid management? Ten answers to 10 questions
De Backer, D., & Vincent, J.-L. (2018) · Critical Care · doi:10.1186/s13054-018-1959-3 · Cited by 255
Self-citationDoerschug, K. C., Delsing, A. S., Schmidt, G. A., & Ashare, A. (2010) · Critical Care · doi:10.1186/cc8887 · Cited by 119
Metadata
- Authors
- Heenen, S., De Backer, D., & Vincent, J.-L.
- Venue
- Critical Care
- Published
- 2006-07-17
- Volume
- 10
- Issue
- 4
- Pages
- R102-R102
- ISSN
- 1364-8535 (ISSN-L)
- OpenAlex
- W2131282386
- Cited by
- 197
- References
- 0
- FWCI
- 20.57
- Type
- journal article
- Language
- en
- Open access
- gold
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.