The DOI matches its Crossref record; 27 of the 27 references it cites were found in a registry or an index.
Goal-directed fluid management based on pulse pressure variation monitoring during high-risk surgery: a pilot randomized controlled trial
Open accessAbstract
Introduction: Several studies have shown that maximizing stroke volume (or increasing it until a plateau is reached) by volume loading during high-risk surgery may improve post-operative outcome. This goal could be achieved simply by minimizing the variation in arterial pulse pressure (ΔPP) induced by mechanical ventilation. We tested this hypothesis in a prospective, randomized, single-centre study. The primary endpoint was the length of postoperative stay in hospital. Methods: Thirty-three patients undergoing high-risk surgery were randomized either to a control group (group C, n = 16) or to an intervention group (group I, n = 17). In group I, ΔPP was continuously monitored during surgery by a multiparameter bedside monitor and minimized to 10% or less by volume loading. Results: Both groups were comparable in terms of demographic data, American Society of Anesthesiology score, type, and duration of surgery. During surgery, group I received more fluid than group C (4,618 ± 1,557 versus 1,694 ± 705 ml (mean ± SD), P < 0.0001), and ΔPP decreased from 22 ± 75 to 9 ± 1% ( P < 0.05) in group I. The median duration of postoperative stay in hospital (7 versus 17 days, P < 0.01) was lower in group I than in group C. The number of postoperative complications per patient (1.4 ± 2.1 versus 3.9 ± 2.8, P < 0.05), as well as the median duration of mechanical ventilation (1 versus 5 days, P < 0.05) and stay in the intensive care unit (3 versus 9 days, P < 0.01) was also lower in group I. Conclusion: Monitoring and minimizing ΔPP by volume loading during high-risk surgery improves postoperative outcome and decreases the length of stay in hospital. Trial registration: NCT00479011
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
1 retracted
Fluid management of patients undergoing abdominal surgery – more questions than answers *
Boldt, J. (2006) · European Journal of Anaesthesiology · doi:10.1017/s026502150600069x · Cited by 36
RetractedShoemaker, W. C., Appel, P. L., Kram, H. B., Waxman, K., & Lee, T.-S. (1988) · Chest · doi:10.1378/chest.94.6.1176 · Cited by 1,794
Brandstrup, B., Tønnesen, H., Beier-Holgersen, R., Hjortsø, E., Ørding, H., Lindorff-Larsen, K., Rasmussen, M. S., Lanng, C., Wallin, L., Iversen, L. H., et al. (2003) · Annals of Surgery · doi:10.1097/01.sla.0000094387.50865.23 · Cited by 1,585
MICHARD, F., BOUSSAT, S., CHEMLA, D., ANGUEL, N., MERCAT, A., LECARPENTIER, Y., RICHARD, C., PINSKY, M. R., & TEBOUL, J.-L. (2000) · American Journal of Respiratory and Critical Care Medicine · doi:10.1164/ajrccm.162.1.9903035 · Cited by 1,458
Self-citationBoyd, O. (1993) · JAMA: The Journal of the American Medical Association · doi:10.1001/jama.1993.03510220055034 · Cited by 997
Gan, T. J., Soppitt, A., Maroof, M., El-Moalem, H., Robertson, K. M., Moretti, E., Dwane, P., & Glass, P. S. A. (2002) · Anesthesiology · doi:10.1097/00000542-200210000-00012 · Cited by 953
Effect of Intraoperative Fluid Management on Outcome after Intraabdominal Surgery
Nisanevich, V., Felsenstein, I., Almogy, G., Weissman, C., Einav, S., & Matot, I. (2005) · Anesthesiology · doi:10.1097/00000542-200507000-00008 · Cited by 864
Sinclair, S., James, S., & Singer, M. (1997) · BMJ · doi:10.1136/bmj.315.7113.909 · Cited by 742
Changes in Arterial Pressure during Mechanical Ventilation
Michard, F. (2005) · Anesthesiology · doi:10.1097/00000542-200508000-00026 · Cited by 713
Self-citationPulse pressure variations to predict fluid responsiveness: influence of tidal volume
De Backer, D., Heenen, S., Piagnerelli, M., Koch, M., & Vincent, J.-L. (2005) · Intensive Care Medicine · doi:10.1007/s00134-005-2586-4 · Cited by 706
Cited by
Hamilton, M. A., Cecconi, M., & Rhodes, A. (2011) · Anesthesia & Analgesia · doi:10.1213/ane.0b013e3181eeaae5 · Cited by 898
Allegranzi, B., Zayed, B., Bischoff, P., Kubilay, N. Z., de Jonge, S., de Vries, F., Gomes, S. M., Gans, S., Wallert, E. D., Wu, X., et al. (2016) · The Lancet Infectious Diseases · doi:10.1016/s1473-3099(16)30402-9 · Cited by 867
Marik, P. E., & Cavallazzi, R. (2013) · Critical Care Medicine · doi:10.1097/ccm.0b013e31828a25fd · Cited by 866
Hemodynamic parameters to guide fluid therapy
Marik, P. E., Monnet, X., & Teboul, J.-L. (2011) · Annals of Intensive Care · doi:10.1186/2110-5820-1-1 · Cited by 686
Peng, K., Li, J., Cheng, H., & Ji, F.-H. (2014) · Medical Principles and Practice · doi:10.1159/000363573 · Cited by 641
Metadata
- Authors
- Lopes, M. R., Oliveira, M. A., Pereira, V. O. S., Lemos, I. P. B., Auler, J. O. C., & Michard, F.
- Venue
- Critical Care
- Published
- 2007-09-07
- Volume
- 11
- Issue
- 5
- Pages
- R100-R100
- ISSN
- 1364-8535 (ISSN-L)
- OpenAlex
- W2126601156
- Cited by
- 442
- References
- 27
- FWCI
- 23.85
- Type
- journal article
- Language
- en
- Open access
- gold
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Goal-directed fluid management based on pulse pressure variation monitoring during high-risk surgery: a pilot randomized controlled trial. https://app.cochat.ai/papers/10.1186/cc6117
- The paper
- Lopes, M. R., Oliveira, M. A., Pereira, V. O. S., Lemos, I. P. B., Auler, J. O. C., & Michard, F. (2007). Goal-directed fluid management based on pulse pressure variation monitoring during high-risk surgery: a pilot randomized controlled trial. Critical Care. https://doi.org/10.1186/cc6117
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.