Variation in the PaO2/FiO2 ratio with FiO2: mathematical and experimental description, and clinical relevance
Open accessThe DOI matches its Crossref record; 3 of the 3 references it cites were found in a registry or an index.
Abstract
Introduction: Previous studies have shown through theoretical analyses that the ratio of the partial pressure of oxygen in arterial blood (PaO 2) to the inspired oxygen fraction (FiO 2) varies with the FiO 2 level. The aim of the present study was to evaluate the relevance of this variation both theoretically and experimentally using mathematical model simulations, comparing these ratio simulations with PaO 2/FiO 2 ratios measured in a range of different patients. Methods: The study was designed as a retrospective study using data from 36 mechanically ventilated patients and 57 spontaneously breathing patients studied on one or more occasions. Patients were classified into four disease groups (normal, mild hypoxemia, acute lung injury and acute respiratory distress syndrome) according to their PaO 2/FiO 2 ratio. On each occasion the patients were studied using four to eight different FiO 2 values, achieving arterial oxygen saturations in the range 85–100%. At each FiO 2 level, measurements were taken of ventilation, of arterial acid–base and of oxygenation status. Two mathematical models were fitted to the data: a one-parameter 'effective shunt' model, and a two-parameter shunt and ventilation/perfusion model. These models and patient data were used to investigate the variation in the PaO 2/FiO 2 ratio with FiO 2, and to quantify how many patients changed disease classification due to variation in the PaO 2/FiO 2 ratio. An F test was used to assess the statistical difference between the two models' fit to the data. A confusion matrix was used to quantify the number of patients changing disease classification. Results: The two-parameter model gave a statistically better fit to patient data (P < 0.005). When using this model to simulate variation in the PaO 2/FiO 2 ratio, disease classification changed in 30% of the patients when changing the FiO 2 level. Conclusion: The PaO 2/FiO 2 ratio depends on both the FiO 2 level and the arterial oxygen saturation level. As a minimum, the FiO 2 level at which the PaO 2/FiO 2 ratio is measured should be defined when quantifying the effects of therapeutic interventions or when specifying diagnostic criteria for acute lung injury and acute respiratory distress syndrome. Alternatively, oxygenation problems could be described using parameters describing shunt and ventilation/perfusion mismatch.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Practical Statistics for Medical Research
Altman, D. G. (1990) · doi:10.1201/9780429258589 · Cited by 10,668
Bernard, G. R., Artigas, A., Brigham, K. L., Carlet, J., Falke, K., Hudson, L., Lamy, M., Legall, J. R., Morris, A., & Spragg, R. (1994) · American journal of respiratory and critical care medicine · doi:10.1164/ajrccm.149.3.7509706 · Cited by 6,746
Amato, M. B., Barbas, C. S., Medeiros, D. M., Schettino, G. D. P., Lorenzi Filho, G., Kairalla, R. A., Deheinzelin, D., Morais, C., Fernandes, E. D. O., & Takagaki, T. Y. (1995) · American journal of respiratory and critical care medicine · doi:10.1164/ajrccm.152.6.8520744 · Cited by 625 · cited 1×
“The ratio has been used in numerous experimental studies to quantify pulmonary gas exchange before and after therapeutic intervention (for example [1-3]).”
Method
Cited by
Parhar, K. K. S., Zjadewicz, K., Soo, A., Sutton, A., Zjadewicz, M., Doig, L., Lam, C., Ferland, A., Niven, D. J., Fiest, K. M., et al. (2019) · Annals of the American Thoracic Society · doi:10.1513/annalsats.201812-910oc · Cited by 159
“…between fraction of inspired oxygen (F I O 2 ) and arterial oxygen tension to inspired fraction of oxygen ratio (PF ratio) and therefore the applied F I O 2 can in fl uence the PF ratio at the time of diagnosis (14 – 16), potentially leading to misclassi fi cation of the severity of ARDS.”
Metadata
- Authors
- Karbing, D. S., Kjærgaard, S., Smith, B. W., Espersen, K., Allerød, C., Andreassen, S., & Rees, S. E.
- Venue
- Critical Care
- Published
- 2007-11-07
- Volume
- 11
- Issue
- 6
- Pages
- R118-R118
- ISSN
- 1364-8535 (ISSN-L)
- OpenAlex
- W2041780055
- Cited by
- 177
- References
- 3
- FWCI
- 3.12
- Type
- journal article
- Language
- en
- Open access
- gold
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Variation in the PaO2/FiO2 ratio with FiO2: mathematical and experimental description, and clinical relevance. https://app.cochat.ai/papers/10.1186/cc6174
- The paper
- Karbing, D. S., Kjærgaard, S., Smith, B. W., Espersen, K., Allerød, C., Andreassen, S., & Rees, S. E. (2007). Variation in the PaO2/FiO2 ratio with FiO2: mathematical and experimental description, and clinical relevance. Critical Care. https://doi.org/10.1186/cc6174
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.