Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 262

The DOI matches its Crossref record; 45 of the 45 references it cites were found in a registry or an index.

Implementation and evaluation of the SPRINT protocol for tight glycaemic control in critically ill patients: a clinical practice change

Open access
Chase, JGeoffrey, Shaw, Geoffrey, Le Compte, Aaron, Lonergan, Timothy, Willacy, Michael, Wong, Xing-Wei, Lin, Jessica, Lotz, Thomas, Lee, Dominic, Hann, Christopher · 2008 · Critical Care

Abstract

Introduction: Stress-induced hyperglycaemia is prevalent in critical care. Control of blood glucose levels to within a 4.4 to 6.1 mmol/L range or below 7.75 mmol/L can reduce mortality and improve clinical outcomes. The Specialised Relative Insulin Nutrition Tables (SPRINT) protocol is a simple wheel-based system that modulates insulin and nutritional inputs for tight glycaemic control. Methods: SPRINT was implemented as a clinical practice change in a general intensive care unit (ICU). The objective of this study was to measure the effect of the SPRINT protocol on glycaemic control and mortality compared with previous ICU control methods. Glycaemic control and mortality outcomes for 371 SPRINT patients with a median Acute Physiology And Chronic Health Evaluation (APACHE) II score of 18 (interquartile range [IQR] 15 to 24) are compared with a 413-patient retrospective cohort with a median APACHE II score of 18 (IQR 15 to 23). Results: Overall, 53.9% of all measurements were in the 4.4 to 6.1 mmol/L band. Blood glucose concentrations were found to be log-normal and thus log-normal statistics are used throughout to describe the data. The average log-normal glycaemia was 6.0 mmol/L (standard deviation 1.5 mmol/L). Only 9.0% of all measurements were below 4.4 mmol/L, with 3.8% below 4 mmol/L and 0.1% of measurements below 2.2 mmol/L. On SPRINT, 80% more measurements were in the 4.4 to 6.1 mmol/L band and standard deviation of blood glucose was 38% lower compared with the retrospective control. The range and peak of blood glucose were not correlated with mortality for SPRINT patients (P >0.30). For ICU length of stay (LoS) of greater than or equal to 3 days, hospital mortality was reduced from 34.1% to 25.4% (-26%) (P = 0.05). For ICU LoS of greater than or equal to 4 days, hospital mortality was reduced from 34.3% to 23.5% (-32%) (P = 0.02). For ICU LoS of greater than or equal to 5 days, hospital mortality was reduced from 31.9% to 20.6% (-35%) (P = 0.02). ICU mortality was also reduced but the P value was less than 0.13 for ICU LoS of greater than or equal to 4 and 5 days. Conclusion: SPRINT achieved a high level of glycaemic control on a severely ill critical cohort population. Reductions in mortality were observed compared with a retrospective hyperglycaemic cohort. Range and peak blood glucose metrics were no longer correlated with mortality outcome under SPRINT.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1186/cc6868

Cites

45 of 45 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 45 references

Cited by

Metadata

Authors
Chase, J., Shaw, G., Le Compte, A., Lonergan, T., Willacy, M., Wong, X.-W., Lin, J., Lotz, T., Lee, D., & Hann, C.
Venue
Critical Care
Published
2008-04-16
Volume
12
Issue
2
Pages
R49-R49
ISSN
1364-8535 (ISSN-L)
OpenAlex
W1971436236
Cited by
262
References
45
FWCI
17.21
Type
journal article
Language
en
Open access
gold

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.