IPO: a tool for automated optimization of XCMS parameters
Open accessThe DOI matches its Crossref record; 22 of the 22 references it cites were found in a registry or an index.
Abstract
BACKGROUND: Untargeted metabolomics generates a huge amount of data. Software packages for automated data processing are crucial to successfully process these data. A variety of such software packages exist, but the outcome of data processing strongly depends on algorithm parameter settings. If they are not carefully chosen, suboptimal parameter settings can easily lead to biased results. Therefore, parameter settings also require optimization. Several parameter optimization approaches have already been proposed, but a software package for parameter optimization which is free of intricate experimental labeling steps, fast and widely applicable is still missing. RESULTS: We implemented the software package IPO ('Isotopologue Parameter Optimization') which is fast and free of labeling steps, and applicable to data from different kinds of samples and data from different methods of liquid chromatography - high resolution mass spectrometry and data from different instruments. IPO optimizes XCMS peak picking parameters by using natural, stable (13)C isotopic peaks to calculate a peak picking score. Retention time correction is optimized by minimizing relative retention time differences within peak groups. Grouping parameters are optimized by maximizing the number of peak groups that show one peak from each injection of a pooled sample. The different parameter settings are achieved by design of experiments, and the resulting scores are evaluated using response surface models. IPO was tested on three different data sets, each consisting of a training set and test set. IPO resulted in an increase of reliable groups (146% - 361%), a decrease of non-reliable groups (3% - 8%) and a decrease of the retention time deviation to one third. CONCLUSIONS: IPO was successfully applied to data derived from liquid chromatography coupled to high resolution mass spectrometry from three studies with different sample types and different chromatographic methods and devices. We were also able to show the potential of IPO to increase the reliability of metabolomics data. The source code is implemented in R, tested on Linux and Windows and it is freely available for download at https://github.com/glibiseller/IPO . The training sets and test sets can be downloaded from https://health.joanneum.at/IPO .
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Smith, C. A., Want, E. J., O'Maille, G., Abagyan, R., & Siuzdak, G. (2006) · Analytical Chemistry · doi:10.1021/ac051437y · Cited by 5,262
Some New Three Level Designs for the Study of Quantitative Variables
Box, G. E. P., & Behnken, D. W. (1960) · Technometrics · doi:10.1080/00401706.1960.10489912 · Cited by 4,177
Pluskal, T., Castillo, S., Villar-Briones, A., & Orešič, M. (2010) · BMC Bioinformatics · doi:10.1186/1471-2105-11-395 · Cited by 3,845
XCMS Online: A Web-Based Platform to Process Untargeted Metabolomic Data
Tautenhahn, R., Patti, G. J., Rinehart, D., & Siuzdak, G. (2012) · Analytical Chemistry · doi:10.1021/ac300698c · Cited by 1,319
Kuhl, C., Tautenhahn, R., Böttcher, C., Larson, T. R., & Neumann, S. (2012) · Analytical Chemistry · doi:10.1021/ac202450g · Cited by 1,203
Self-citationHighly sensitive feature detection for high resolution LC/MS
Tautenhahn, R., Böttcher, C., & Neumann, S. (2008) · BMC Bioinformatics · doi:10.1186/1471-2105-9-504 · Cited by 1,185
Self-citationLommen, A. (2009) · Analytical Chemistry · doi:10.1021/ac900036d · Cited by 734
Metabolomic Analysis and Visualization Engine for LC−MS Data
Melamud, E., Vastag, L., & Rabinowitz, J. D. (2010) · Analytical Chemistry · doi:10.1021/ac1021166 · Cited by 619
Bajad, S. U., Lu, W., Kimball, E. H., Yuan, J., Peterson, C., & Rabinowitz, J. D. (2006) · Journal of Chromatography A · doi:10.1016/j.chroma.2006.05.019 · Cited by 592
apLCMS—adaptive processing of high-resolution LC/MS data
Yu, T., Park, Y., Johnson, J. M., & Jones, D. P. (2009) · Bioinformatics · doi:10.1093/bioinformatics/btp291 · Cited by 406
Cited by
MetaboAnalyst 5.0: narrowing the gap between raw spectra and functional insights
Pang, Z., Chong, J., Zhou, G., de Lima Morais, D. A., Chang, L., Barrette, M., Gauthier, C., Jacques, P.-É., Li, S., & Xia, J. (2021) · Nucleic Acids Research · doi:10.1093/nar/gkab382 · Cited by 3,958
Feature-based molecular networking in the GNPS analysis environment
Nothias, L.-F., Petras, D., Schmid, R., Dührkop, K., Rainer, J., Sarvepalli, A., Protsyuk, I., Ernst, M., Tsugawa, H., Fleischauer, M., et al. (2020) · Nature Methods · doi:10.1038/s41592-020-0933-6 · Cited by 1,634
Self-citationPang, Z., Zhou, G., Ewald, J., Chang, L., Hacariz, O., Basu, N., & Xia, J. (2022) · Nature Protocols · doi:10.1038/s41596-022-00710-w · Cited by 1,444
MetaboAnalystR 3.0: Toward an Optimized Workflow for Global Metabolomics
Pang, Z., Chong, J., Li, S., & Xia, J. (2020) · Metabolites · doi:10.3390/metabo10050186 · Cited by 558
Santoru, M. L., Piras, C., Murgia, A., Palmas, V., Camboni, T., Liggi, S., Ibba, I., Lai, M. A., Orrù, S., Blois, S., et al. (2017) · Scientific Reports · doi:10.1038/s41598-017-10034-5 · Cited by 387
Guo, J., & Huan, T. (2020) · Analytical Chemistry · doi:10.1021/acs.analchem.9b05135 · Cited by 312
HEx: A heterologous expression platform for the discovery of fungal natural products
Harvey, C. J. B., Tang, M., Schlecht, U., Horecka, J., Fischer, C. R., Lin, H.-C., Li, J., Naughton, B., Cherry, J. A., Miranda, M., et al. (2018) · Science Advances · doi:10.1126/sciadv.aar5459 · Cited by 247
Computational Metabolomics: A Framework for the Million Metabolome
Uppal, K., Walker, D. I., Liu, K., Li, S., Go, Y.-M., & Jones, D. P. (2016) · Chemical Research in Toxicology · doi:10.1021/acs.chemrestox.6b00179 · Cited by 244
“13,36,37,49 xMSanalyzer is an R package that uses a scoring function based on number and quality of features determined based on coefficient of variation (CV) within technical replicates. xMSanalyzer is designed to work with apLCMS, XCMS, and other data extraction software.”
Helmus, R., ter Laak, T. L., van Wezel, A. P., de Voogt, P., & Schymanski, E. L. (2021) · Journal of Cheminformatics · doi:10.1186/s13321-020-00477-w · Cited by 208
Agrawal, S., Kumar, S., Sehgal, R., George, S., Gupta, R., Poddar, S., Jha, A., & Pathak, S. (2019) · Methods in Molecular Biology · doi:10.1007/978-1-4939-9236-2_19 · Cited by 205
Metabolomic analysis of urine samples by UHPLC-QTOF-MS: Impact of normalization strategies
Gagnebin, Y., Tonoli, D., Lescuyer, P., Ponte, B., de Seigneux, S., Martin, P.-Y., Schappler, J., Boccard, J., & Rudaz, S. (2017) · Analytica Chimica Acta · doi:10.1016/j.aca.2016.12.029 · Cited by 203
Brunius, C., Shi, L., & Landberg, R. (2016) · Metabolomics · doi:10.1007/s11306-016-1124-4 · Cited by 182
“XCMS peak picking parameters (prefilter, peakwidth, mzdiff, snthresh) were obtained using the IPO R package (Libiseller et al. 2015).”
MethodA roadmap for the XCMS family of software solutions in metabolomics
Mahieu, N. G., Genenbacher, J. L., & Patti, G. J. (2016) · Current Opinion in Chemical Biology · doi:10.1016/j.cbpa.2015.11.009 · Cited by 151
High-resolution metabolomics of occupational exposure to trichloroethylene
Walker, D. I., Uppal, K., Zhang, L., Vermeulen, R., Smith, M., Hu, W., Purdue, M. P., Tang, X., Reiss, B., Kim, S., et al. (2016) · International Journal of Epidemiology · doi:10.1093/ije/dyw218 · Cited by 107
Alygizakis, N., Lestremau, F., Gago-Ferrero, P., Gil-Solsona, R., Arturi, K., Hollender, J., Schymanski, E. L., Dulio, V., Slobodnik, J., & Thomaidis, N. S. (2023) · TrAC Trends in Analytical Chemistry · doi:10.1016/j.trac.2023.116944 · Cited by 103
Narath, S. H., Mautner, S. I., Svehlikova, E., Schultes, B., Pieber, T. R., Sinner, F. M., Gander, E., Libiseller, G., Schimek, M. G., Sourij, H., et al. (2016) · PLOS ONE · doi:10.1371/journal.pone.0161425 · Cited by 65
“XCMS parameters were optimized by the R-package IPO [49].”
MethodSelf-citationCharidemou, E., Ashmore, T., Li, X., McNally, B. D., West, J. A., Liggi, S., Harvey, M., Orford, E., & Griffin, J. L. (2019) · JCI Insight · doi:10.1172/jci.insight.124819 · Cited by 52
Costa, A., Riça, L., van de Bilt, M., Zandonadi, F., Gattaz, W., Talib, L., & Sussulini, A. (2023) · Metabolites · doi:10.3390/metabo13050600 · Cited by 25
“Using RStudio (RStudio, Boston, MA, USA), the parameters for data processing with the ‘xcms’ package [33] were optimized with the ‘IPO’ package [34] based on QC samples.”
Method
Metadata
- Authors
- Libiseller, G., Dvorzak, M., Kleb, U., Gander, E., Eisenberg, T., Madeo, F., Neumann, S., Trausinger, G., Sinner, F., Pieber, T., & Magnes, C.
- Venue
- BMC Bioinformatics
- Published
- 2015-04-16
- Volume
- 16
- Issue
- 1
- Pages
- 118-118
- ISSN
- 1471-2105 (ISSN-L)
- OpenAlex
- W2073939393
- Cited by
- 342
- References
- 22
- FWCI
- 9.65
- Type
- journal article
- Language
- en
- Open access
- gold
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.