The DOI matches its Crossref record; 8 of the 8 references it cites were found in a registry or an index.
A Sequel to Sanger: amplicon sequencing that scales
Open accessAbstract
BACKGROUND: Although high-throughput sequencers (HTS) have largely displaced their Sanger counterparts, the short read lengths and high error rates of most platforms constrain their utility for amplicon sequencing. The present study tests the capacity of single molecule, real-time (SMRT) sequencing implemented on the SEQUEL platform to overcome these limitations, employing 658 bp amplicons of the mitochondrial cytochrome c oxidase I gene as a model system. RESULTS: By examining templates from more than 5000 species and 20,000 specimens, the performance of SMRT sequencing was tested with amplicons showing wide variation in GC composition and varied sequence attributes. SMRT and Sanger sequences were very similar, but SMRT sequencing provided more complete coverage, especially for amplicons with homopolymer tracts. Because it can characterize amplicon pools from 10,000 DNA extracts in a single run, the SEQUEL can reduce greatly reduce sequencing costs in comparison to first (Sanger) and second generation platforms (Illumina, Ion). CONCLUSIONS: SMRT analysis generates high-fidelity sequences from amplicons with varying GC content and is resilient to homopolymer tracts. Analytical costs are low, substantially less than those for first or second generation sequencers. When implemented on the SEQUEL platform, SMRT analysis enables massive amplicon characterization because each instrument can recover sequences from more than 5 million DNA extracts a year.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Cutadapt removes adapter sequences from high-throughput sequencing reads
Martin, M. (2011) · EMBnet.journal · doi:10.14806/ej.17.1.200 · Cited by 33,889
Needleman, S. B., & Wunsch, C. D. (1970) · Journal of Molecular Biology · doi:10.1016/0022-2836(70)90057-4 · Cited by 11,288
A DNA-Based Registry for All Animal Species: The Barcode Index Number (BIN) System
Ratnasingham, S., & Hebert, P. D. N. (2013) · PLoS ONE · doi:10.1371/journal.pone.0066213 · Cited by 2,301
Self-citationQuail, M., Smith, M. E., Coupland, P., Otto, T. D., Harris, S. R., Connor, T. R., Bertoni, A., Swerdlow, H. P., & Gu, Y. (2012) · BMC Genomics · doi:10.1186/1471-2164-13-341 · Cited by 2,031 · cited 1×
“Despite its high error (13%) in single base calls [3], its long reads permit the generation of circular consensus sequences (CCSs) [15].”
The sequence of sequencers: The history of sequencing DNA
Heather, J. M., & Chain, B. (2016) · Genomics · doi:10.1016/j.ygeno.2015.11.003 · Cited by 1,397 · cited 2×
“While Sanger analysis is effective for sequencing amplicons up to 1 kb [14, 47], the characterization of longer”
Carew, M. E., Pettigrove, V. J., Metzeling, L., & Hoffmann, A. A. (2013) · Frontiers in Zoology · doi:10.1186/1742-9994-10-45 · Cited by 243
Sequencing 16S rRNA gene fragments using the PacBio SMRT DNA sequencing system.
Schloss, P. D., Jenior, M. L., Koumpouras, C. C., Westcott, S. L., & Highlander, S. K. (2016) · PeerJ · doi:10.7717/peerj.1869 · Cited by 226 · cited 1×
“Earlier studies have reported similar results, but they focused on 16S rRNA and examined far fewer templates [32, 33].”
Koster, M. J. E., & Timmers, H. T. M. (2015) · Nucleic Acids Research · doi:10.1093/nar/gku1263 · Cited by 55
Cited by
Wenger, A. M., Peluso, P., Rowell, W. J., Chang, P.-C., Hall, R. J., Concepcion, G. T., Ebler, J., Fungtammasan, A., Kolesnikov, A., Olson, N. D., et al. (2019) · Nature Biotechnology · doi:10.1038/s41587-019-0217-9 · Cited by 1,841
Callahan, B. J., Wong, J., Heiner, C., Oh, S., Theriot, C. M., Gulati, A. S., McGill, S. K., & Dougherty, M. K. (2019) · Nucleic Acids Research · doi:10.1093/nar/gkz569 · Cited by 706
Long-Read Sequencing Emerging in Medical Genetics
Mantere, T., Kersten, S., & Hoischen, A. (2019) · Frontiers in Genetics · doi:10.3389/fgene.2019.00426 · Cited by 440
Biases in bulk: DNA metabarcoding of marine communities and the methodology involved
van der Loos, L. M., & Nijland, R. (2021) · Molecular Ecology · doi:10.1111/mec.15592 · Cited by 268
Pomerantz, A., Peñafiel, N., Arteaga, A., Bustamante, L., Pichardo, F., Coloma, L. A., Barrio-Amorós, C. L., Salazar-Valenzuela, D., & Prost, S. (2018) · GigaScience · doi:10.1093/gigascience/giy033 · Cited by 256
Metadata
- Authors
- Hebert, P. D. N., Braukmann, T. W. A., Prosser, S. W. J., Ratnasingham, S., deWaard, J. R., Ivanova, N. V., Janzen, D. H., Hallwachs, W., Naik, S., Sones, J. E., & Zakharov, E. V.
- Venue
- BMC Genomics
- Published
- 2018-03-27
- Volume
- 19
- Issue
- 1
- Pages
- 219-219
- ISSN
- 1471-2164 (ISSN-L)
- OpenAlex
- W2949819089
- Cited by
- 280
- References
- 8
- FWCI
- 9.81
- Type
- journal article
- Language
- en
- Open access
- gold
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: A Sequel to Sanger: amplicon sequencing that scales. https://app.cochat.ai/papers/10.1186/s12864-018-4611-3
- The paper
- Hebert, P. D. N., Braukmann, T. W. A., Prosser, S. W. J., Ratnasingham, S., deWaard, J. R., Ivanova, N. V., Janzen, D. H., Hallwachs, W., Naik, S., Sones, J. E., & Zakharov, E. V. (2018). A Sequel to Sanger: amplicon sequencing that scales. BMC Genomics. https://doi.org/10.1186/s12864-018-4611-3
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.