CoChat

Time to publication among completed diagnostic accuracy studies: associated with reported accuracy estimates

Open access
Korevaar, Daniël A., van Es, Nick, Zwinderman, Aeilko H., Cohen, Jérémie F., Bossuyt, Patrick M. M. · 2016 · BMC Medical Research Methodology
Cited by 20

The DOI matches its Crossref record; 19 of the 19 references it cites were found in a registry or an index.

Abstract

BACKGROUND: Previous evaluations have documented that studies evaluating the effectiveness of therapeutic interventions are not always reported, and that those with statistically significant results are published more rapidly than those without. This can lead to reporting bias in systematic reviews and other literature syntheses. We evaluated whether diagnostic accuracy studies that report promising results about the performance of medical tests are also published more rapidly. METHODS: We obtained all primary diagnostic accuracy studies included in meta-analyses of Medline-indexed systematic reviews that were published between September 2011 and January 2012. For each primary study, we extracted estimates of diagnostic accuracy (sensitivity, specificity, Youden's index), the completion date of participant recruitment, and the publication date. We calculated the time from completion to publication and assessed associations with reported accuracy estimates. RESULTS: Forty-nine systematic reviews were identified, containing 92 meta-analyses and 924 unique primary studies, of which 756 could be included. Study completion dates were missing for 285 (38 %) of these. Median time from completion to publication in the remaining 471 studies was 24 months (IQR 16 to 35). Primary studies that reported higher estimates of sensitivity (Spearman's rho = -0.14; p = 0.003), specificity (rho = -0.17; p < 0.001), and Youden's index (rho = -0.22; p < 0.001) had significantly shorter times to publication. When comparing time to publication in studies reporting accuracy estimates above versus below the median, the median number of months was 23 versus 25 for sensitivity (p = 0.046), 22 versus 27 for specificity (p = 0.001), and 22 versus 27 for Youden's index (p < 0.001). These differential time lags remained significant in multivariable Cox regression analyses with adjustment for other study characteristics, with hazard ratios of publication of 1.06 (95 % CI 1.02 to 1.11; p = 0.007) for logit-transformed estimates of sensitivity, 1.09 (95 % CI 1.04 to 1.14; p < 0.001) for logit-transformed estimates of specificity, and 1.09 (95 % CI 1.03 to 1.14; p = 0.001) for logit-transformed estimates of Youden's index. CONCLUSIONS: Time to publication was significantly shorter for studies reporting higher estimates of diagnostic accuracy compared to those reporting lower estimates. This suggests that searching and analyzing the published literature, rather than all completed studies, can produce a biased view of the performance of medical tests.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1186/s12874-016-0177-4

Cites

19 of 19 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 19 references

Cited by

See all 20

Metadata

Authors
Korevaar, D. A., van Es, N., Zwinderman, A. H., Cohen, J. F., & Bossuyt, P. M. M.
Venue
BMC Medical Research Methodology
Published
2016-06-06
Volume
16
Issue
1
Pages
68-68
ISSN
1471-2288 (ISSN-L)
OpenAlex
W2412701052
Cited by
20
References
19
FWCI
2.75
Type
journal article
Language
en
Open access
gold

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Time to publication among completed diagnostic accuracy studies: associated with reported accuracy estimates. https://app.cochat.ai/papers/10.1186/s12874-016-0177-4
The paper
Korevaar, D. A., van Es, N., Zwinderman, A. H., Cohen, J. F., & Bossuyt, P. M. M. (2016). Time to publication among completed diagnostic accuracy studies: associated with reported accuracy estimates. BMC Medical Research Methodology. https://doi.org/10.1186/s12874-016-0177-4

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.