Performance of ultrasonography screening for breast cancer: a systematic review and meta-analysis
Open accessThe DOI matches its Crossref record; 8 of the 8 references it cites were found in a registry or an index.
Abstract
Background: To investigate the performance of primary ultrasound (P-US) screening for breast cancer, and that of supplemental ultrasound (S-US) screening for breast cancer after negative mammography (MAM). Methods: Electronic databases (PubMed, Scopus, Web of Science, and Embase) were systematically searched to identify relevant studies published between January 2003 and May 2018. Only high-quality or fair-quality studies reporting any of the following performance values for P-US or S-US screening were included: sensitivity, specificity, cancer detected rate (CDR), recall rate (RR), biopsy rate (BR), proportion of invasive cancers among screening-detected cancers (ProIC), and proportion of node-negative cancers among screening-detected invasive cancers (ProNNIC). Results: Twenty-three studies were included, including 12 studies in which S-US screening was used after negative MAM and 11 joint screening studies in which both primary MAM (P-MAM) and P-US were used. Meta-analyses revealed that S-US screening could detect 96% [95% confidential intervals (CIs): 82 to 99%] of occult breast cancers missed by MAM and identify 93% (95% CIs: 89 to 96%) of healthy women, with a CDR of 3.0/1000 (95% CIs: 1.8/1000 to 4.6/1000), RR of 8.8% (95% CIs: 5.0 to 13.4%), BR of 3.9% (95% CIs: 2.7 to 5.4%), ProIC of 73.9% (95% CIs: 49.0 to 93.7%), and ProNNIC of 70.9% (95% CIs: 46.0 to 91.6%). Compared with P-MAM screening, P-US screening led to the recall of significantly more women with positive screening results [1.5% (95% CIs:0.6 to 2.3%), P = 0.001] and detected significantly more invasive cancers [16.3% (95% CIs: 10.6 to 22.1%), P < 0.001]. However, there were no significant differences for other performance measures between the two screening methods, including sensitivity, specificity, CDR, BR, and ProNNIC. Conclusions: Current evidence suggests that S-US screening could detect occult breast cancers missed by MAM. P-US screening has shown to be comparable to P-MAM screening in women with dense breasts in terms of sensitivity, specificity, cancer detection rate, and biopsy rate, but with higher recall rates and higher detection rates for invasive cancers.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Towards complete and accurate reporting of studies of diagnostic accuracy: The STARD Initiative.
Bossuyt, P. M., Reitsma, J. B., Bruns, D. E., Gatsonis, C. A., Glasziou, P. P., Irwig, L. M., Lijmer, J. G., Moher, D., Rennie, D., de Vet, H. C. W., et al. (2003) · Annals of Internal Medicine · doi:10.7326/0003-4819-138-1-200301070-00010 · Cited by 3,219
Towards complete and accurate reporting of studies of diagnostic accuracy: the STARD initiative
Bossuyt, P. M., Reitsma, J. B., Bruns, D. E., Gatsonis, C. A., Glasziou, P. P., Irwig, L. M., Lijmer, J. G., Moher, D., Rennie, D., & de Vet, H. C. W. (2003) · BMJ · doi:10.1136/bmj.326.7379.41 · Cited by 3,215
Towards Complete and Accurate Reporting of Studies of Diagnostic Accuracy: The STARD Initiative
Bossuyt, P. M., Reitsma, J. B., Bruns, D. E., Gatsonis, C. A., Glasziou, P. P., Irwig, L. M., Lijmer, J. G., Moher, D., Rennie, D., & de Vet, H. C. W. (2003) · Radiology · doi:10.1148/radiol.2261021292 · Cited by 3,215
McInnes, M. D. F., Moher, D., Thombs, B. D., McGrath, T. A., Bossuyt, P. M., and the PRISMA-DTA Group, Clifford, T., Cohen, J. F., Deeks, J. J., Gatsonis, C., et al. (2018) · JAMA · doi:10.1001/jama.2017.19163 · Cited by 3,210
Metaprop: a Stata command to perform meta-analysis of binomial data
Nyaga, V. N., Arbyn, M., & Aerts, M. (2014) · Archives of Public Health · doi:10.1186/2049-3258-72-39 · Cited by 2,139
Screening for breast cancer: U.S. Preventive Services Task Force recommendation statement
Siu, A. L., & on behalf of the U.S. Preventive Services Task Force (2016) · Annals of Internal Medicine · doi:10.7326/m15-2886 · Cited by 2,094
Oeffinger, K. C., Fontham, E. T. H., Etzioni, R., Herzig, A., Michaelson, J. S., Shih, Y.-C. T., Walter, L. C., Church, T. R., Flowers, C. R., LaMonte, S. J., et al. (2015) · JAMA · doi:10.1001/jama.2015.12783 · Cited by 1,653
Metan: fixed- and random-effects meta-analysis
Harris, R. J., Deeks, J. J., Altman, D. G., Bradburn, M. J., Harbord, R. M., & Sterne, J. A. C. (2008) · The Stata Journal: Promoting communications on statistics and Stata · doi:10.1177/1536867x0800800102 · Cited by 1,027
Cited by
McInnes, M. D. F., Moher, D., Thombs, B. D., McGrath, T. A., Bossuyt, P. M., and the PRISMA-DTA Group, Clifford, T., Cohen, J. F., Deeks, J. J., Gatsonis, C., et al. (2018) · JAMA · doi:10.1001/jama.2017.19163 · Cited by 3,210
Shen, Y., Shamout, F. E., Oliver, J. R., Witowski, J., Kannan, K., Park, J., Wu, N., Huddleston, C., Wolfson, S., Millet, A., et al. (2021) · Nature Communications · doi:10.1038/s41467-021-26023-2 · Cited by 270
Pfob, A., Sidey-Gibbons, C., Barr, R. G., Duda, V., Alwafai, Z., Balleyguier, C., Clevert, D.-A., Fastner, S., Gomez, C., Goncalo, M., et al. (2022) · European Radiology · doi:10.1007/s00330-021-08519-z · Cited by 29
“Especially breast ultrasound has been under intense evaluation over the past years as it showed potential to identify cancers that are initially missed in mammography but ultrasound also leads to more false-positive findings [7].”
BackgroundAI: Can It Make a Difference to the Predictive Value of Ultrasound Breast Biopsy?
Browne, J. L., Pascual, M. Á., Perez, J., Salazar, S., Valero, B., Rodriguez, I., Cassina, D., Alcázar, J. L., Guerriero, S., & Graupera, B. (2023) · Diagnostics · doi:10.3390/diagnostics13040811 · Cited by 20
Huang, X., Qiu, Y., Bao, F., Wang, J., Lin, C., Lin, Y., Wu, J., & Yang, H. (2023) · Frontiers in Public Health · doi:10.3389/fpubh.2022.1098639 · Cited by 6
Metadata
- Authors
- Yang, L., Wang, S., Zhang, L., Sheng, C., Song, F., Wang, P., & Huang, Y.
- Venue
- BMC Cancer
- Published
- 2020-06-01
- Volume
- 20
- Issue
- 1
- Pages
- 499-499
- ISSN
- 1471-2407 (ISSN-L)
- OpenAlex
- W3030108548
- Cited by
- 98
- References
- 8
- FWCI
- 2.12
- Type
- journal article
- Language
- en
- Open access
- gold
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Performance of ultrasonography screening for breast cancer: a systematic review and meta-analysis. https://app.cochat.ai/papers/10.1186/s12885-020-06992-1
- The paper
- Yang, L., Wang, S., Zhang, L., Sheng, C., Song, F., Wang, P., & Huang, Y. (2020). Performance of ultrasonography screening for breast cancer: a systematic review and meta-analysis. BMC Cancer. https://doi.org/10.1186/s12885-020-06992-1
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.