Worldwide Argus II implantation: recommendations to optimize patient outcomes
Open accessThe DOI matches its Crossref record; 7 of the 7 references it cites were found in a registry or an index.
Abstract
BACKGROUND: A position paper based on the collective experiences of Argus II Retinal Prosthesis System investigators to review strategies to optimize outcomes in patients with retinitis pigmentosa undergoing retinal prosthesis implantation. METHODS: Retinal surgeons, device programmers, and rehabilitation specialists from Europe, Canada, Middle East, and the United States were convened to the first international Argus II Investigator Meeting held in Ann Arbor, MI in March 2015. The recommendations from the collective experiences were collected. Factors associated with successful outcomes were determined. RESULTS: Factors leading to successful outcomes begin with appropriate patient selection, expectation counseling, and preoperative retinal assessment. Challenges to surgical implantation include presence of staphyloma and inadequate Tenon's capsule or conjunctiva. Modified surgical technique may reduce risks of complications such as hypotony and conjunctival erosion. Rehabilitation efforts and correlation with validated outcome measures following implantation are critical. CONCLUSIONS: Bringing together Argus II investigators allowed the identification of strategies to optimize patient outcomes. Establishing an on-line collaborative network will foster coordinated research efforts to advance outcome assessment and rehabilitation strategies.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Hartong, D. T., Berson, E. L., & Dryja, T. P. (2006) · The Lancet · doi:10.1016/s0140-6736(06)69740-7 · Cited by 2,924
Interim results from the international trial of Second Sight's visual prosthesis
Humayun, M. S., Dorn, J. D., da Cruz, L., Dagnelie, G., Sahel, J.-A., Stanga, P. E., Cideciyan, A. V., Duncan, J. L., Eliott, D., Filley, E., et al. (2012) · Ophthalmology · doi:10.1016/j.ophtha.2011.09.028 · Cited by 700 · cited 1×
“sults with visual function as well as improved performance on orientation and mobility tasks [4–8].”
BackgroundSelf-citationda Cruz, L., Coley, B. F., Dorn, J., Merlini, F., Filley, E., Christopher, P., Chen, F. K., Wuyyuru, V., Sahel, J., Stanga, P., et al. (2013) · British Journal of Ophthalmology · doi:10.1136/bjophthalmol-2012-301525 · Cited by 359 · cited 1×
“sults with visual function as well as improved performance on orientation and mobility tasks [4–8].”
BackgroundSelf-citationAhuja, A. K., Dorn, J. D., Caspi, A., McMahon, M. J., Dagnelie, G., daCruz, L., Stanga, P., Humayun, M. S., Greenberg, R. J., & Argus II Study Group (2011) · British Journal of Ophthalmology · doi:10.1136/bjo.2010.179622 · Cited by 289 · cited 1×
“sults with visual function as well as improved performance on orientation and mobility tasks [4–8].”
BackgroundSelf-citationJensen, R. J., Rizzo, J. F., Ziv, O. R., Grumet, A., & Wyatt, J. (2003) · Investigative Opthalmology & Visual Science · doi:10.1167/iovs.02-1041 · Cited by 145
Preliminary 6 month results from the argustm ii epiretinal prosthesis feasibility study
Humayun, M. S., Dorn, J. D., Ahuja, A. K., Caspi, A., Filley, E., Dagnelie, G., Salzmann, J., Santos, A., Duncan, J., daCruz, L., et al. (2009) · 2009 Annual International Conference of the IEEE Engineering in Medicine and Biology Society · doi:10.1109/iembs.2009.5332695 · Cited by 100 · cited 1×
“Visual acuity was measured by three methods: grating visual acuity, square localization, and direction of motion [21].”
MethodSelf-citationFLORA™: phase I development of a functional vision assessment for prosthetic vision users
Geruschat, D. R., Flax, M., Tanna, N., Bianchi, M., Fisher, A., Goldschmidt, M., Fisher, L., Dagnelie, G., Deremeik, J., Smith, A., et al. (2015) · Clinical and Experimental Optometry · doi:10.1111/cxo.12242 · Cited by 75
Self-citation
Cited by
Beyeler, M., Rokem, A., Boynton, G. M., & Fine, I. (2017) · Journal of Neural Engineering · doi:10.1088/1741-2552/aa795e · Cited by 102
Finn, A., Grewal, D., & Vajzovic, L. (2018) · Clinical ophthalmology · doi:10.2147/opth.s137525 · Cited by 71
A Second-Generation (44-Channel) Suprachoroidal Retinal Prosthesis: Interim Clinical Trial Results
Petoe, M. A., Titchener, S. A., Kolic, M., Kentler, W. G., Abbott, C. J., Nayagam, D. A. X., Baglin, E. K., Kvansakul, J., Barnes, N., Walker, J. G., et al. (2021) · Translational Vision Science & Technology · doi:10.1167/tvst.10.10.12 · Cited by 63
Bionic eye review - An update.
Nowik, K., Langwińska-Wośko, E., Skopiński, P., Nowik, K. E., & Szaflik, J. P. (2020) · Journal of Clinical Neuroscience · doi:10.1016/j.jocn.2020.05.041 · Cited by 49
One-Year Safety and Performance Assessment of the Argus II Retinal Prosthesis: A Postapproval Study
Schaffrath, K., Schellhase, H., Walter, P., Augustin, A., Chizzolini, M., Kirchhof, B., Grisanti, S., Wiedemann, P., Szurman, P., Richard, G., et al. (2019) · JAMA Ophthalmology · doi:10.1001/jamaophthalmol.2019.1476 · Cited by 44
Self-citation
Metadata
- Authors
- Ghodasra, D. H., Chen, A., Arevalo, J. F., Birch, D. G., Branham, K., Coley, B., Dagnelie, G., de Juan, E., Devenyi, R. G., Dorn, J. D., Fisher, A., Geruschat, D. R., Gregori, N. Z., Greenberg, R. J., Hahn, P., Ho, A. C., Howson, A., Huang, S. S., Iezzi, R., Khan, N., Lam, B. L., Lim, J. I., Locke, K. G., Markowitz, M., Ripley, A.-M., Rankin, M., Schimitzek, H., Tripp, F., Weiland, J. D., Yan, J., Zacks, D. N., & Jayasundera, K. T.
- Venue
- BMC Ophthalmology
- Published
- 2016-05-06
- Volume
- 16
- Issue
- 1
- Pages
- 52-52
- ISSN
- 1471-2415 (ISSN-L)
- OpenAlex
- W2345822578
- Cited by
- 50
- References
- 7
- FWCI
- 4.24
- Type
- journal article
- Language
- en
- Open access
- gold
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Worldwide Argus II implantation: recommendations to optimize patient outcomes. https://app.cochat.ai/papers/10.1186/s12886-016-0225-1
- The paper
- Ghodasra, D. H., Chen, A., Arevalo, J. F., Birch, D. G., Branham, K., Coley, B., Dagnelie, G., de Juan, E., Devenyi, R. G., Dorn, J. D., Fisher, A., Geruschat, D. R., Gregori, N. Z., Greenberg, R. J., Hahn, P., Ho, A. C., Howson, A., Huang, S. S., Iezzi, R., . . . Jayasundera, K. T. (2016). Worldwide Argus II implantation: recommendations to optimize patient outcomes. BMC Ophthalmology. https://doi.org/10.1186/s12886-016-0225-1
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.