A motion-classification strategy based on sEMG-EEG signal combination for upper-limb amputees
Open accessThe DOI matches its Crossref record; 43 of the 43 references it cites were found in a registry or an index.
Abstract
BACKGROUND: Most of the modern motorized prostheses are controlled with the surface electromyography (sEMG) recorded on the residual muscles of amputated limbs. However, the residual muscles are usually limited, especially after above-elbow amputations, which would not provide enough sEMG for the control of prostheses with multiple degrees of freedom. Signal fusion is a possible approach to solve the problem of insufficient control commands, where some non-EMG signals are combined with sEMG signals to provide sufficient information for motion intension decoding. In this study, a motion-classification method that combines sEMG and electroencephalography (EEG) signals were proposed and investigated, in order to improve the control performance of upper-limb prostheses. METHODS: Four transhumeral amputees without any form of neurological disease were recruited in the experiments. Five motion classes including hand-open, hand-close, wrist-pronation, wrist-supination, and no-movement were specified. During the motion performances, sEMG and EEG signals were simultaneously acquired from the skin surface and scalp of the amputees, respectively. The two types of signals were independently preprocessed and then combined as a parallel control input. Four time-domain features were extracted and fed into a classifier trained by the Linear Discriminant Analysis (LDA) algorithm for motion recognition. In addition, channel selections were performed by using the Sequential Forward Selection (SFS) algorithm to optimize the performance of the proposed method. RESULTS: The classification performance achieved by the fusion of sEMG and EEG signals was significantly better than that obtained by single signal source of either sEMG or EEG. An increment of more than 14% in classification accuracy was achieved when using a combination of 32-channel sEMG and 64-channel EEG. Furthermore, based on the SFS algorithm, two optimized electrode arrangements (10-channel sEMG + 10-channel EEG, 10-channel sEMG + 20-channel EEG) were obtained with classification accuracies of 84.2 and 87.0%, respectively, which were about 7.2 and 10% higher than the accuracy by using only 32-channel sEMG input. CONCLUSIONS: This study demonstrated the feasibility of fusing sEMG and EEG signals towards improving motion classification accuracy for above-elbow amputees, which might enhance the control performances of multifunctional myoelectric prostheses in clinical application. TRIAL REGISTRATION: The study was approved by the ethics committee of Institutional Review Board of Shenzhen Institutes of Advanced Technology, and the reference number is SIAT-IRB-150515-H0077.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Delorme, A., & Makeig, S. (2004) · Journal of Neuroscience Methods · doi:10.1016/j.jneumeth.2003.10.009 · Cited by 24,371 · cited 1×
“1991) [19] was applied to process the EEG data, where the mean of baseline for each channel was removed and the EEG epochs of each motion class was extracted based on the onset-endpoint lines.”
Peng, H., Long, F., & Ding, C. (2005) · IEEE Transactions on Pattern Analysis and Machine Intelligence · doi:10.1109/tpami.2005.159 · Cited by 10,544 · cited 1×
“4, for both sEMG and EEG signals, the classification accuracies increased significantly with the increase of channel number until about 10, but the increase slowed down if more channels were further added, which means that the last set of signal channels may not provide much effective information for motion classifica…”
Reach and grasp by people with tetraplegia using a neurally controlled robotic arm
Hochberg, L. R., Bacher, D., Jarosiewicz, B., Masse, N. Y., Simeral, J. D., Vogel, J., Haddadin, S., Liu, J., Cash, S. S., van der Smagt, P., et al. (2012) · Nature · doi:10.1038/nature11076 · Cited by 2,719
A new strategy for multifunction myoelectric control
Hudgins, B., Parker, P., & Scott, R. N. (1993) · IEEE Transactions on Biomedical Engineering · doi:10.1109/10.204774 · Cited by 2,149
A robust, real-time control scheme for multifunction myoelectric control
Englehart, K., & Hudgins, B. (2003) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2003.813539 · Cited by 1,743
Feature reduction and selection for EMG signal classification
Phinyomark, A., Phukpattaranont, P., & Limsakul, C. (2012) · Expert Systems with Applications · doi:10.1016/j.eswa.2012.01.102 · Cited by 1,542
Targeted Muscle Reinnervation for Real-time Myoelectric Control of Multifunction Artificial Arms
Kuiken, T. A. (2009) · JAMA · doi:10.1001/jama.2009.116 · Cited by 1,089 · cited 2×
“In the future, the efficiencies of hybrid methods, especially the one with optimized channel sets, would be investigated in real-time environment and assessed by more measures such as motion selection time, motion completion time, and motion completion rate [7, 40].”
FASTER: Fully Automated Statistical Thresholding for EEG artifact Rejection
Nolan, H., Whelan, R., & Reilly, R. B. (2010) · Journal of Neuroscience Methods · doi:10.1016/j.jneumeth.2010.07.015 · Cited by 1,077 · cited 1×
“Different from S-I, the dual-signal method of S-II (32-ch sEMG+ 32-ch EEG) used only the first 32 of total 64 EEG channels located on the cerebral cortex area, which is associated with the thinking and motion functions [20, 21].”
Farina, D., Jiang, N., Rehbaum, H., Holobar, A., Graimann, B., Dietl, H., & Aszmann, O. C. (2014) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2014.2305111 · Cited by 992
Scheme, E., & Englehart, K. (2011) · The Journal of Rehabilitation Research and Development · doi:10.1682/jrrd.2010.09.0177 · Cited by 969 · cited 1×
“As a result, multifunctional myoelectric prostheses for above-elbow amputees are still seldom seen on the market [7, 8].”
Control of an Electrical Prosthesis With an SSVEP-Based BCI
Muller-Putz, G. R., & Pfurtscheller, G. (2008) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2007.897815 · Cited by 589 · cited 1×
“developed a non-invasive BCI system based on the steady-state visual evoked potentials (SSVEPs) to control a prosthetic hand, where a varied classification accuracy between 44 and 88% was obtained on able-bodied subjects [11].”
Huang, H., Zhang, F., Hargrove, L. J., Dou, Z., Rogers, D. R., & Englehart, K. B. (2011) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2011.2161671 · Cited by 542 · cited 1×
“Multiple-source signal fusion is a possible solution for the problem of insufficient information in prosthesis control [13, 14], where some non-EMG signals are combined to sEMG signals to realize a more precise extraction of motor commands.”
How about taking a low‐cost, small, and wireless EEG for a walk?
Debener, S., Minow, F., Emkes, R., Gandras, K., & de Vos, M. (2012) · Psychophysiology · doi:10.1111/j.1469-8986.2012.01471.x · Cited by 540 · cited 1×
“Both the sEMG and EEG acquisition systems used in the experiments have been integrated with a pre-filter by the producers [17, 18].”
Jiang, N., Englehart, K. B., & Parker, P. A. (2009) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2008.2007967 · Cited by 450
Quantifying Pattern Recognition—Based Myoelectric Control of Multifunctional Transradial Prostheses
Li, G., Schultz, A. E., & Kuiken, T. A. (2010) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2009.2039619 · Cited by 443
Self-citationEvaluation of the forearm EMG signal features for the control of a prosthetic hand
Boostani, R., & Moradi, M. H. (2003) · Physiological Measurement · doi:10.1088/0967-3334/24/2/307 · Cited by 391 · cited 1×
“The linear discriminant analysis (LDA) classifier [25, 27, 31, 32] was used for motion classification.”
van Kuijk, A. A., Bakker, C. D., Hendriks, J. C., Geurts, A. C., Stegeman, D. F., & Pasman, J. W. (2014) · Journal of NeuroEngineering and Rehabilitation · doi:10.1186/1743-0003-11-1 · Cited by 373
Jiang, N., Rehbaum, H., Vujaklija, I., Graimann, B., & Farina, D. (2014) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2013.2278411 · Cited by 269 · cited 1×
“Both the sEMG and EEG acquisition systems used in the experiments have been integrated with a pre-filter by the producers [17, 18].”
The Best Two Independent Measurements Are Not the Two Best
Cover, T. M. (1974) · IEEE Transactions on Systems, Man, and Cybernetics · doi:10.1109/tsmc.1974.5408535 · Cited by 248 · cited 3×
“A possible reason is that in oS-I, the optimal 10-ch sEMG and 20-ch EEG were selected by using the SFS algorithm from the 32 sEMG and 64 EEG channels, respectively, and therefore they might not be the best matching group for motion classification, which is consistent with the conclusion by Cover [39].”
InfluentialDiers, M., Christmann, C., Koeppe, C., Ruf, M., & Flor, H. (2010) · Pain · doi:10.1016/j.pain.2010.02.020 · Cited by 240
A comparison of quantitative EEG features for neonatal seizure detection
Greene, B. R., Faul, S., Marnane, W. P., Lightbody, G., Korotchikova, I., & Boylan, G. B. (2008) · Clinical Neurophysiology · doi:10.1016/j.clinph.2008.02.001 · Cited by 217
Hargrove, L. J., Li, G., Englehart, K. B., & Hudgins, B. S. (2009) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2008.2008171 · Cited by 211
Self-citationHuang, H., Zhou, P., Li, G., & Kuiken, T. A. (2008) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2007.910282 · Cited by 187 · cited 1×
“In the future, the efficiencies of hybrid methods, especially the one with optimized channel sets, would be investigated in real-time environment and assessed by more measures such as motion selection time, motion completion time, and motion completion rate [7, 40].”
Self-citationSchultz, A. E., & Kuiken, T. A. (2011) · PM&R · doi:10.1016/j.pmrj.2010.06.016 · Cited by 186 · cited 1×
“However, EEG is usually limited for clinical use due to either the biocompatibility of implantable electrode and signal instability for long term application in an invasive way or the low information transmission rate, low spatial resolution, and high signal variability in a non-invasive way [1, 12].”
Geng, Y., Zhou, P., & Li, G. (2012) · Journal of NeuroEngineering and Rehabilitation · doi:10.1186/1743-0003-9-74 · Cited by 183 · cited 1×
“4 and 6) and some previous studies [6, 33].”
Self-citationNon-invasive control interfaces for intention detection in active movement-assistive devices
Lobo-Prat, J., Kooren, P. N., Stienen, A. H. A., Herder, J. L., Koopman, H. F. J. M., & Veltink, P. H. (2014) · Journal of NeuroEngineering and Rehabilitation · doi:10.1186/1743-0003-11-168 · Cited by 173
Disentangling motor execution from motor imagery with the phantom limb
Raffin, E., Mattout, J., Reilly, K. T., & Giraux, P. (2012) · Brain · doi:10.1093/brain/awr337 · Cited by 143 · cited 1×
“1) 32-ch sEMG, where only 32 sEMG electrodes were used; 2) 64-ch EEG, where only 64 EEG electrodes were used; 3) 32-ch EEG, where the first 32 of 64 EEG electrodes were used, locating on the frontal, temporal, and central lobes of cerebral cortex that are associated with thinking and motion functions [21, 22], as show…”
Daley, H., Englehart, K. B., Hargrove, L. J., & Kuruganti, U. (2012) · Journal of Electromyography and Kinesiology · doi:10.1016/j.jelekin.2011.12.012 · Cited by 143 · cited 3×
“The proposed hybrid method combining sEMG and EEG was additionally optimized by decreasing the channel number with the sequential forward selection (SFS) algorithm [31, 33, 34].”
Brain Computer Interface: A Review
Fouad, M. M., Amin, K. M., El-Bendary, N., & Hassanien, A. E. (2014) · Intelligent systems reference library · doi:10.1007/978-3-319-10978-7_1 · Cited by 83
Lalitharatne, T., Teramoto, K., Hayashi, Y., & Kiguchi, K. (2013) · Paladyn J. Behav. Robotics · doi:10.2478/pjbr-2013-0009 · Cited by 77 · cited 1×
“Multiple-source signal fusion is a possible solution for the problem of insufficient information in prosthesis control [13, 14], where some non-EMG signals are combined to sEMG signals to realize a more precise extraction of motor commands.”
Woodhouse, A. (2005) · Clinical and Experimental Pharmacology and Physiology · doi:10.1111/j.1440-1681.2005.04142.x · Cited by 67
Geng, Y., Zhang, X., Zhang, Y., & Li, G. (2014) · BioMedical Engineering OnLine · doi:10.1186/1475-925x-13-102 · Cited by 64 · cited 3×
“The proposed hybrid method combining sEMG and EEG was additionally optimized by decreasing the channel number with the sequential forward selection (SFS) algorithm [31, 33, 34].”
Self-citationIntroduction to Neural Engineering for Motor Rehabilitation
Farina, D., Jensen, W., & Akay, M. (2013) · Wiley eBooks · doi:10.1002/9781118628522 · Cited by 61 · cited 2×
“However, EEG is usually limited for clinical use due to either the biocompatibility of implantable electrode and signal instability for long term application in an invasive way or the low information transmission rate, low spatial resolution, and high signal variability in a non-invasive way [1, 12].”
Brain Computer Interface: A Review
Pal, D., Palit, S., & Dey, A. (2021) · Lecture notes in electrical engineering · doi:10.1007/978-981-16-4035-3_3 · Cited by 55
Towards reducing the impacts of unwanted movements on identification of motion intentions
Li, X., Chen, S., Zhang, H., Samuel, O. W., Wang, H., Fang, P., Zhang, X., & Li, G. (2016) · Journal of Electromyography and Kinesiology · doi:10.1016/j.jelekin.2016.03.005 · Cited by 44
Self-citationProstheses Control with Combined Near-Infrared and Myoelectric Signals
Herrmann, S., Attenberger, A., & Buchenrieder, K. J. (2012) · Lecture notes in computer science · doi:10.1007/978-3-642-27579-1_77 · Cited by 39 · cited 1×
“A method based on the combination of sEMG and near-infrared (NIR) signals was reported [15], where hand gestures could be identified by adjoining two or more sEMG/NIR sensors.”
Improving Myoelectric Control for Amputees through Transcranial Direct Current Stimulation
Pan, L., Zhang, D., Sheng, X., & Zhu, X. (2015) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2015.2407491 · Cited by 38 · cited 1×
“The linear discriminant analysis (LDA) classifier [25, 27, 31, 32] was used for motion classification.”
Omurtag, A., Baki, S. G. A., Chari, G., Cracco, R. Q., Zehtabchi, S., Fenton, A. A., & Grant, A. C. (2012) · International Journal of Emergency Medicine · doi:10.1186/1865-1380-5-35 · Cited by 31
Fang, P., Geng, Y., Wei, Z. X., Zhou, P., Tian, L., & Li, G. (2015) · IEEE Intelligent Systems · doi:10.1109/mis.2015.40 · Cited by 20 · cited 1×
“Some previous works have demonstrated the feasibility of using speech as an additional input to realize a flexible control of multifunctional myoelectric prostheses [16].”
Self-citationInverse consistent non-rigid image registration based on robust point set matching
Yang, X., Pei, J., & Shi, J. (2014) · BioMedical Engineering OnLine · doi:10.1186/1475-925x-13-s2-s2 · Cited by 16
Wang, H., Fang, P., Tian, L., Zheng, Y., Zhou, H. D., Li, G., & Zhang, X. (2015) · Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC) · doi:10.1109/embc.2015.7319114 · Cited by 9
Self-citationLi, X., Chen, S., Zhang, H., Zhang, X., & Li, G. (2014) · Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC) · doi:10.1109/embc.2014.6944147 · Cited by 5 · cited 1×
“The linear discriminant analysis (LDA) classifier [25, 27, 31, 32] was used for motion classification.”
Self-citationMaterial-aware cloth simulation via constrained geometric deformation
Liu, L., Su, Z., Wang, R., & Luo, X. (2012) · Computers & Graphics · doi:10.1016/j.cag.2012.10.006 · Cited by 4 · cited 1×
“, which would eventually affect the acceptability of prostheses [34, 37].”
Cited by
Brain-Controlled Robotic Arm System Based on Multi-Directional CNN-BiLSTM Network Using EEG Signals
Jeong, J.-H., Shim, K.-H., Kim, D.-J., & Lee, S.-W. (2020) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2020.2981659 · Cited by 292
SAE+LSTM: A New Framework for Emotion Recognition From Multi-Channel EEG
Xing, X., Li, Z., Xu, T., Shu, L., Hu, B., & Xu, X. (2019) · Frontiers in Neurorobotics · doi:10.3389/fnbot.2019.00037 · Cited by 269
Samuel, O. W., Asogbon, M. G., Geng, Y., Al-Timemy, A. H., Pirbhulal, S., Ji, N., Chen, S., Fang, P., & Li, G. (2019) · IEEE Access · doi:10.1109/access.2019.2891350 · Cited by 185
“The control method adopted in developing a prosthesis determines the functionality supported by the device, it ease of use, and acceptability [1]–[4].”
MethodSelf-citationYang, G., Zhu, K., Guo, W., Wu, D., Quan, X., Huang, X., Liu, S., Li, Y., Fang, H., Qiu, Y., et al. (2022) · Advanced Functional Materials · doi:10.1002/adfm.202200457 · Cited by 177
A review on EMG/EEG based control scheme of upper limb rehabilitation robots for stroke patients
Sarhan, S. M., Al-Faiz, M. Z., & Takhakh, A. M. (2023) · Heliyon · doi:10.1016/j.heliyon.2023.e18308 · Cited by 41
“A feasible solution to these difficulties is the combination of the benefits of both types of signals [44].”
Metadata
- Authors
- Li, X., Samuel, O. W., Zhang, X., Wang, H., Fang, P., & Li, G.
- Venue
- Journal of NeuroEngineering and Rehabilitation
- Published
- 2017-01-07
- Volume
- 14
- Issue
- 1
- Pages
- 2-2
- ISSN
- 1743-0003 (ISSN-L)
- OpenAlex
- W2569969175
- Cited by
- 199
- References
- 43
- FWCI
- 8.26
- Type
- journal article
- Language
- en
- Open access
- gold
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.