D’Andola, Mattia, Giulioni, Massimiliano, Dante, Vittorio, Del Giudice, Paolo, Sanchez-Vives, Maria V. · 2019 · Journal of NeuroEngineering and Rehabilitation

The DOI matches its Crossref record; 53 of the 53 references it cites were found in a registry or an index.

Abstract

BACKGROUND: We present a closed-loop system able to control the frequency of slow oscillations (SO) spontaneously generated by the cortical network in vitro. The frequency of SO can be controlled by direct current (DC) electric fields within a certain range. Here we set out to design a system that would be able to autonomously bring the emergent oscillatory activity to a target frequency determined by the experimenter. METHODS: The cortical activity was recorded through an electrode and was analyzed online. Once a target frequency was set, the frequency of the slow oscillation was steered through the injection of DC of variable intensity that generated electric fields of proportional amplitudes in the brain slice. To achieve such closed-loop control, we designed a custom programmable stimulator ensuring low noise and accurate tuning over low current levels. For data recording and analysis, we relied on commercial acquisition and software tools. RESULTS: The result is a flexible and reliable system that ensures control over SO frequency in vitro. The system guarantees artifact removal, minimal gaps in data acquisition and robustness in spite of slice heterogeneity. CONCLUSIONS: Our tool opens new possibilities for the investigation of dynamics of cortical slow oscillations-an activity pattern that is associated with cognitive processes such as memory consolidation, and that is altered in several neurological conditions-and also for potential applications of this technology.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1186/s12984-018-0470-z

Cites

53 of 53 references verified0 citation errors · 0 not checkable

Statistics

Figures

Fig. 1 Closed-loop system. At the bottom of the figure is a photograph of four cortical slices in the recording chamber. In a counterclockwise direction, the loop proceeds from recording to stimulation. To the right, a sample of the local field potential (LFP) signal recorded from layer 5 is amplified, digitalized and sent to the PC via USB. At the top, the PC performs the online analysis for Up-state recognition and slow oscillation (SO) computation. To the left, the custom-made stimulator is controlled by the PC via Bluetooth. The stimulator injects DC current (i) into the slices by creating an adequate potential difference (ΔV) between the stimulation electrodes
Fig. 1 Closed-loop system. At the bottom of the figure is a photograph of four cortical slices in the recording chamber. In a counterclockwise direction, the loop proceeds from recording to stimulation. To the right, a sample of the local field potential (LFP) signal recorded from layer 5 is amplified, digitalized and sent to the PC via USB. At the top, the PC performs the online analysis for Up-state recognition and slow oscillation (SO) computation. To the left, the custom-made stimulator is controlled by the PC via Bluetooth. The stimulator injects DC current (i) into the slices by creating an adequate potential difference (ΔV) between the stimulation electrodesCC BY · PubMed Central
Fig. 2 Sample recording traces, stimulation configuration and SO frequency behavior across injected DC currents. a Sample recording (3 s). Bottom row, raw LFP trace; middle and top rows, the MUA and MUA waveforms, respectively, obtained with online filtering of the LFP. Up states (gray shade) were automatically recognized through the use of amplitude and time thresholds in the MUA traces. b Scheme of electrode stimulation setup. Electric fields were directed parallel to the polarization direction of pyramidal neurons. c Typical distribution of SO frequency across injected currents for one of the recorded slices (mean ± SD). For each stimulation current (x axis), all the measured values of the slow oscillation frequency obtained during the stimulation interval at that specific intensity were averaged (58 values). The logarithm of the SO frequency monotonically increases with the applied DC currents. The linear fit is superimposed [28] (p-value = 3.9182 × 10− 7). The variability of the response to the stimulation across the five tested slices is showed in the inset by superimposing the linear fits for each slice, after normalization to the control condition (spontaneous activity). LFP, local field potential; MUA, multiunit activity; SO, slow oscillations
Fig. 2 Sample recording traces, stimulation configuration and SO frequency behavior across injected DC currents. a Sample recording (3 s). Bottom row, raw LFP trace; middle and top rows, the MUA and MUA waveforms, respectively, obtained with online filtering of the LFP. Up states (gray shade) were automatically recognized through the use of amplitude and time thresholds in the MUA traces. b Scheme of electrode stimulation setup. Electric fields were directed parallel to the polarization direction of pyramidal neurons. c Typical distribution of SO frequency across injected currents for one of the recorded slices (mean ± SD). For each stimulation current (x axis), all the measured values of the slow oscillation frequency obtained during the stimulation interval at that specific intensity were averaged (58 values). The logarithm of the SO frequency monotonically increases with the applied DC currents. The linear fit is superimposed [28] (p-value = 3.9182 × 10− 7). The variability of the response to the stimulation across the five tested slices is showed in the inset by superimposing the linear fits for each slice, after normalization to the control condition (spontaneous activity). LFP, local field potential; MUA, multiunit activity; SO, slow oscillationsCC BY · PubMed Central
Fig. 3 Diagram of the stimulator. Input voltage is applied at Vinj, output current flows between IOut and Gnd. The leftmost resistor branch ensures the current zero-point. AD62 0 AD is an instrumental amplifier; AD79 5 AD is an operational amplifier with very high input impedance. The configuration of the two amplifiers implements a feedback circuit based on the voltage across the R332 resistor, which dictates the V/I conversion factor
Fig. 3 Diagram of the stimulator. Input voltage is applied at Vinj, output current flows between IOut and Gnd. The leftmost resistor branch ensures the current zero-point. AD62 0 AD is an instrumental amplifier; AD79 5 AD is an operational amplifier with very high input impedance. The configuration of the two amplifiers implements a feedback circuit based on the voltage across the R332 resistor, which dictates the V/I conversion factorCC BY · PubMed Central
Fig. 4 Experimental protocol. Left, initial open-loop characterization part: top left, profile of the applied current. Stimulation phases last 60 s. Current levels span the [− 0.6 + 0.6] mA range with 0.1-mA steps. There were 20 s between successive stimulation phases. Right, closed-loop part: bottom right, profile of the desired target SO frequency. A stimulation pause of 40 s was enforced after every set of three targets (0.5, 0.1 and 0.8 Hz)
Fig. 4 Experimental protocol. Left, initial open-loop characterization part: top left, profile of the applied current. Stimulation phases last 60 s. Current levels span the [− 0.6 + 0.6] mA range with 0.1-mA steps. There were 20 s between successive stimulation phases. Right, closed-loop part: bottom right, profile of the desired target SO frequency. A stimulation pause of 40 s was enforced after every set of three targets (0.5, 0.1 and 0.8 Hz)CC BY · PubMed Central
Fig. 5 A closed-loop run. Recording (400 s) from the closed-loop part of the protocol. Top panel: black trace represents the applied current. Central panel: blue trace represents the online measure of the SO frequency. The line is dashed during the transition phase. The fine-tuning closed-loop phases start soon after the transition phase. Dashed black lines represent the desired target frequency levels (0.5, 0.1 and 0.8 Hz). Around the target frequency, the blue shade represents the tolerance range, that was set at 10% of the target frequency (0.01 Hz, 0.05 Hz and 0.08 Hz respectively). MUA traces are shown for the last 10 s of each target phase. Bottom panel: three sections of the recording illustrating the expanded areas indicated. Each section illustrates one of the reached oscillatory frequencies. SO, slow oscillations; RMS, voltage root mean square to identify occurrence of SO
Fig. 5 A closed-loop run. Recording (400 s) from the closed-loop part of the protocol. Top panel: black trace represents the applied current. Central panel: blue trace represents the online measure of the SO frequency. The line is dashed during the transition phase. The fine-tuning closed-loop phases start soon after the transition phase. Dashed black lines represent the desired target frequency levels (0.5, 0.1 and 0.8 Hz). Around the target frequency, the blue shade represents the tolerance range, that was set at 10% of the target frequency (0.01 Hz, 0.05 Hz and 0.08 Hz respectively). MUA traces are shown for the last 10 s of each target phase. Bottom panel: three sections of the recording illustrating the expanded areas indicated. Each section illustrates one of the reached oscillatory frequencies. SO, slow oscillations; RMS, voltage root mean square to identify occurrence of SOCC BY · PubMed Central
Fig. 6 System flexibility and stability. a Behavior of SO frequency for all the slices (n = 5, color-coded). At t = 0, the closed-loop fine-tuning phase starts. In some cases (particularly at target 0.1 Hz), the frequency did not reach the target in the maximum time imposed by our protocol (120 s). The slope of the patterns, particularly for target 0.5 Hz and 0.8 Hz, suggests that the frequency would have reached the target over time. The same cannot be said for what concerns the 0.1 Hz, where many times the reached frequency was strongly decreased to a value between 0 and 0.2 Hz. b Data acquired from repetitions of one slice (slice 1) during a single uninterrupted series of 3 closed-loop protocols complete runs. Differences between the repetitions of the same target-reaching phase exist: the closed loop compensates for such unpredictable variations. Shadow bars represent the tolerance range, set at 10% of the target frequency (0.01 Hz, 0.05 Hz and 0.08 Hz respectively)
Fig. 6 System flexibility and stability. a Behavior of SO frequency for all the slices (n = 5, color-coded). At t = 0, the closed-loop fine-tuning phase starts. In some cases (particularly at target 0.1 Hz), the frequency did not reach the target in the maximum time imposed by our protocol (120 s). The slope of the patterns, particularly for target 0.5 Hz and 0.8 Hz, suggests that the frequency would have reached the target over time. The same cannot be said for what concerns the 0.1 Hz, where many times the reached frequency was strongly decreased to a value between 0 and 0.2 Hz. b Data acquired from repetitions of one slice (slice 1) during a single uninterrupted series of 3 closed-loop protocols complete runs. Differences between the repetitions of the same target-reaching phase exist: the closed loop compensates for such unpredictable variations. Shadow bars represent the tolerance range, set at 10% of the target frequency (0.01 Hz, 0.05 Hz and 0.08 Hz respectively)CC BY · PubMed Central
Fig. 7 Artifact management and adaptive behavior to large current steps. a Top panel: firing rate (logMUA), first 7 s of recording after a large (~ 1 mA) step in the injected current (from ~ − 0.4 mA to ~ 0.6 mA). An adaptation phenomenon is visible. The red and green dashed circles highlight respectively the changes in the MUA baseline and in the amplitude of the Up states during and after the adaptation phase. Bottom panel: the corresponding MUA trace. The arrows mark three artifacts due to three small (< 50 μA) current updates. b Top panel: firing rate (logMUA) illustrating slow oscillations. Bottom panel: spikes in the MUA trace are artifacts due to current updates: the amplitude of the artifacts is proportional to the current jump. Artifacts are removed before computing the MUA trace (top panel) and do not affect the Up state detection. MUA, multiunit activity. Inset, one expanded Up state. Top, log MUA. Bottom, MUA
Fig. 7 Artifact management and adaptive behavior to large current steps. a Top panel: firing rate (logMUA), first 7 s of recording after a large (~ 1 mA) step in the injected current (from ~ − 0.4 mA to ~ 0.6 mA). An adaptation phenomenon is visible. The red and green dashed circles highlight respectively the changes in the MUA baseline and in the amplitude of the Up states during and after the adaptation phase. Bottom panel: the corresponding MUA trace. The arrows mark three artifacts due to three small (< 50 μA) current updates. b Top panel: firing rate (logMUA) illustrating slow oscillations. Bottom panel: spikes in the MUA trace are artifacts due to current updates: the amplitude of the artifacts is proportional to the current jump. Artifacts are removed before computing the MUA trace (top panel) and do not affect the Up state detection. MUA, multiunit activity. Inset, one expanded Up state. Top, log MUA. Bottom, MUACC BY · PubMed Central

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 53 references

Cited by

See all 16

Metadata

Authors
D’Andola, M., Giulioni, M., Dante, V., Del Giudice, P., & Sanchez-Vives, M. V.
Affiliations
  • Consorci Institut D'Investigacions Biomediques August Pi I Sunyer (ES)
  • Istituto Superiore di Sanità (IT)
  • Institució Catalana de Recerca i Estudis Avançats (ES)
Corresponding author
Sanchez-Vives, Maria V.
Venue
Journal of NeuroEngineering and Rehabilitation
Published
2019-01-09
Volume
16
Issue
1
Pages
7-7
ISSN
1743-0003 (ISSN-L)
OpenAlex
W2914771135
Cited by
16
References
52
Citations by year
2026: 1 · 2025: 3 · 2024: 5 · 2023: 3 · 2022: 1 · 2021: 2 · 2019: 1
FWCI
0.58
Type
journal article
Language
en
Open access
Licence
  • cc-by
  • creativecommons.org/licenses/by/4.0/ (tdm)
Locations
  • Journal of NeuroEngineering and Rehabilitation (publishedVersion, cc-by)
  • Europe PMC (PubMed Central) (publishedVersion, cc-by)
  • PubMed Central (publishedVersion, cc-by)
  • PubMed (publishedVersion)
  • DOAJ (DOAJ: Directory of Open Access Journals) (submittedVersion, cc-by-sa)
  • Zenodo (CERN European Organization for Nuclear Research) (submittedVersion, cc-by)
Funders
  • Ministerio de Economía y Competitividad (BFU2017-85048-R)
  • FP7 Information and Communication Technologies (600806)
  • Ministerio de Economía, Industria y Competitividad, Gobierno de España (FLAG-ERA (PCIN-2015-162-C02-01))
Topics
  • Life Sciences › Neuroscience › Cognitive Neuroscience › Neural dynamics and brain function
  • Life Sciences › Neuroscience › Cellular and Molecular Neuroscience › Neuroscience and Neural Engineering
  • Life Sciences › Neuroscience › Neurology › Transcranial Magnetic Stimulation Studies
Keywords
brain slices, memory consolidation, neurological disorders
MeSH terms
Animals, Brain, Electric Stimulation, Female, Ferrets, Male, Organ Culture Techniques, Brain-Computer Interfaces

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Control of cortical oscillatory frequency by a closed-loop system. https://app.cochat.ai/papers/10.1186/s12984-018-0470-z
The paper
D’Andola, M., Giulioni, M., Dante, V., Del Giudice, P., & Sanchez-Vives, M. V. (2019). Control of cortical oscillatory frequency by a closed-loop system. Journal of NeuroEngineering and Rehabilitation. https://doi.org/10.1186/s12984-018-0470-z

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.