CoChat

Macrophages bend long fibres with flexural rigidity lower than 3 mN·nm2 to avoid frustrated phagocytosis

Open access
Broßell, Dirk, Meyer-Plath, Asmus, Gräb, Oliver, Heunisch, Elisabeth, Kämpf, Kerstin, Haase, Andrea, Wiemann, Martin · 2026 · Particle and Fibre Toxicology

Published version of a preprint

The DOI matches its Crossref record; 48 of the 48 references it cites were found in a registry or an index; 5 of the 47 sources its claims cite were checked for support.

Abstract

Background: It is an established toxicological principle that the inhalation pathogenicity of respirable and biodurable fibres is caused by excessive fibre length as alveolar macrophages fail to uptake and remove such fibres. However, studies on carbon nanotubes showed that this principle needs revision, as thin, flexible variants showed reduced fibre-specific toxicity. One potential explanation is that the low flexural rigidity of thin fibres enables macrophages to bend and internalize even those that are long relative to the cell size. To evaluate this proposed “rigidity hypothesis,” the mechanisms governing the uptake of flexible long fibres that determine a critical threshold value for flexural rigidity require clarification. Methods: We exposed NR8383 rat alveolar macrophages to three silver nanowire variants differing in diameter and length. Time-lapse microscopy captured fibre uptake processes. Successful internalization of long fibres was found to require fibre bending during uptake. A mechanical model was developed by combining established cytoskeletal biophysics with the observed fibre deformation dynamics. As flexural rigidity describes fibre behaviour under load, our model estimated rigidity by reproducing the observed bent fibre shape. By defining limit cases for physically ‘weak’ and ‘strong’ NR8383 macrophages, i.e., assuming upper bounds on the forces generated by their cytoskeletal nanomachinery, our model enabled us to derive a range for the critical fibre rigidity threshold. Results and conclusion: A macrophage was observed bending an exceptionally long fibre (~ 140 μm) first into an arc and then a spiral for full internalization, initiated by a pseudopod extending along the fibre and buckling the internalized segment. Our model can reproduce such behaviour. It yielded a flexural rigidity of 20 mN·nm² for this fibre. Predicted critical rigidity limits for fibres that just fit into NR8383 macrophages range from 3 to 62 mN·nm². Using the conservative lower bound, long and biodurable fibres with a rigidity lower than 3 mN·nm² are expected to be readily phagocytized by this cell line. Although this rigidity scale may not be directly translatable to human alveolar macrophages, our experimental findings and their modeling emphasize the key role of rigidity in fibre–cell interactions. Fibre rigidity is therefore central for material safety aspects and sustainable product design.

Overview

CoChat Summary

## TL;DR

The paper reports a direct observation of an NR8383 rat alveolar macrophage bending and fully internalizing a very long silver nanowire (~140 μm), supporting the idea that fibre rigidity, not just length, helps determine whether phagocytosis succeeds. Using time-lapse microscopy plus a mechanical model, the authors estimate a conservative NR8383-specific critical flexural rigidity threshold of about 3 mN·nm², below which long fibres are expected to be readily phagocytized.

## Key findings

  • A macrophage was observed bending an exceptionally long silver nanowire (~140 μm) first into an arc and then into a spiral to achieve full internalization; the internalization process took about 46 min, with ~10 min to initial uptake/pseudopod extension.
  • The bent fibre was modeled as having a flexural rigidity of 20 mN·nm², and the model reproduced the observed bending behavior.
  • Predicted critical rigidity limits for fibres that just fit into NR8383 macrophages ranged from 3 to 62 mN·nm²; using the conservative lower bound, fibres below 3 mN·nm² are expected to be readily phagocytized by this cell line.
  • Material characterization showed major differences between silver nanowire variants: fresh Ag-Rods-3170 had a critical fibre fraction of 72% and rigidity of 148\(_{-115}^{+294}\) mN·nm², aged Ag-Rods-3170 had ~54% and 23\(_{-14}^{+26}\) mN·nm², and Ag-NWs-40 had rigidity of 30\(_{-16}^{+28}\) mN·nm².

## Methods

  • In vitro design: NR8383 rat alveolar macrophages were exposed under submerged conditions to three silver nanowire variants differing in length and rigidity: fresh Ag-NWs-40, fresh Ag-Rods-3170, and aged Ag-Rods-3170.
  • Data/sample: 32,000 cells were seeded per compartment, exposed at a final concentration of 2 µg/mL, and monitored by phase-contrast time-lapse microscopy at 1 frame/min; at least 300 fibres per sample were measured for length and diameter by SEM-based characterization.
  • Analysis: The authors combined observed fibre deformation with a mechanical pseudopod-bending model based on cytoskeletal biophysics and Euler–Bernoulli beam theory to estimate fibre rigidity and derive a critical rigidity range.

## Limitations

  • The authors state that only a single fibre-bending event was observed, which limits the validity of the model.
  • They state that the results cannot be directly extrapolated to human physiology; additional experiments with human alveolar macrophages are required to validate the rigidity hypothesis and establish a human threshold.
  • Evident from the text: the rigidity estimate depends on assumed force bounds, literature-based cytoskeletal parameters, and a modeled bending modulus (e.g., 80 ± 20 GPa for Ag-Rods-3170), so the threshold is model-dependent rather than directly measured.

Model-written summary. Check it against the paper before relying on it.

Integrity signals

Registry

Crossref · 10.1186/s12989-026-00666-9

Cites

48 of 48 references verified0 citation errors · 0 not checkable

Statistics

Nothing to recompute.

Figures

Fig. 1 Outline of the ‘rigidity hypothesis’ and supporting observations linking fibre rigidity to distinctly different behaviours during phagocytosis of long fibres. a, Visualization of events observed during phagocytosis of long fibres leading to different outcomes: a macrophage contacts the fibre tip with a pseudopodium, then takes it up into a membrane pouch. If the fibre is flexible (\:\mathcal{R} < \:{\mathcal{R}}_{cr})\:the macrophage can complete phagocytosis. Frustrated phagocytosis occurs when fibre rigidity \:\mathcal{R} exceeds the critical rigidity threshold value \:{\mathcal{R}}_{cr}\:(\:\mathcal{R} > \:{\mathcal{R}}_{cr})\:and is too long to be taken up completely. b, Time-lapse capture of the completion of phagocytosis of a very long fibre of the aged Ag-Rods-3170 variant by a NR8383 macrophage. The fibre is first engaged and partly taken up at time t followed by a pseudopod extending along the fibre shaft (t + 5 min) that subsequently arcs and bends the fibre (t + 8 min), leading to full internalization (t + 38 min). This observation corroborates the stated rigidity hypothesis. Scale bars represent 10 µm. c, Time-lapse captures taken over more two hours apart (t, t + 131 min) of two macrophages unable to take up more rigid fresh Ag-Rods-3170. d, Rigidity histogram calculated for 185 critical (length > 5 µm) aged Ag-Rod-3170 nanowires, indicating that a large portion ( ~ 88%) of critical nanowires exhibited rigidity within the threshold range defined by [25]., e, For fresh Ag-Rods-3170 nanowires, only a small portion exhibited rigidity within the threshold range and a large portion ( ~ 82%) was rigid
Fig. 1 Outline of the ‘rigidity hypothesis’ and supporting observations linking fibre rigidity to distinctly different behaviours during phagocytosis of long fibres. a, Visualization of events observed during phagocytosis of long fibres leading to different outcomes: a macrophage contacts the fibre tip with a pseudopodium, then takes it up into a membrane pouch. If the fibre is flexible (\:\mathcal{R} < \:{\mathcal{R}}_{cr})\:the macrophage can complete phagocytosis. Frustrated phagocytosis occurs when fibre rigidity \:\mathcal{R} exceeds the critical rigidity threshold value \:{\mathcal{R}}_{cr}\:(\:\mathcal{R} > \:{\mathcal{R}}_{cr})\:and is too long to be taken up completely. b, Time-lapse capture of the completion of phagocytosis of a very long fibre of the aged Ag-Rods-3170 variant by a NR8383 macrophage. The fibre is first engaged and partly taken up at time t followed by a pseudopod extending along the fibre shaft (t + 5 min) that subsequently arcs and bends the fibre (t + 8 min), leading to full internalization (t + 38 min). This observation corroborates the stated rigidity hypothesis. Scale bars represent 10 µm. c, Time-lapse captures taken over more two hours apart (t, t + 131 min) of two macrophages unable to take up more rigid fresh Ag-Rods-3170. d, Rigidity histogram calculated for 185 critical (length > 5 µm) aged Ag-Rod-3170 nanowires, indicating that a large portion ( ~ 88%) of critical nanowires exhibited rigidity within the threshold range defined by [25]., e, For fresh Ag-Rods-3170 nanowires, only a small portion exhibited rigidity within the threshold range and a large portion ( ~ 82%) was rigidCC BY · PubMed Central
Fig. 2 Observations of macrophage-fibre interactions. a, After taking up the long silver nanowire of the aged AG-Rods-3170 variant, the macrophage continued to take up a fibre with an extended pseudopod (left panel), initiating bending which results in higher curvature of the fibre (right panel). b, Afterwards, the cell increased its size to ca. 25 μm and the fibre spring extended (left panel). The macrophage attempted to constrain the fibre by decreasing its size to ca. 17 μm (right panel). c, The cell maintained the shape of the fibre spiral while still actively extending pseudopodia (left panel), but after more than three hours after the initial bending event at time \:t, the macrophage seemed to allow unwinding of the nanowire with the tips poking and stretching the cell membrane (right panel). Scale bars in a-c represent 10 μm. d and e, Early time-point (top panel) and late time-point (bottom panel) of macrophages cleansing the fibre-covered surface from nanowires from the Ag-NWs-40 variant, taken ca. 4 h apart. The highlighted areas, covered with nanowires at the beginning, were cleared of fibres during the observation time. The macrophages visibly appear to have increased their fibre load. Scale bars 20 μm
Fig. 2 Observations of macrophage-fibre interactions. a, After taking up the long silver nanowire of the aged AG-Rods-3170 variant, the macrophage continued to take up a fibre with an extended pseudopod (left panel), initiating bending which results in higher curvature of the fibre (right panel). b, Afterwards, the cell increased its size to ca. 25 μm and the fibre spring extended (left panel). The macrophage attempted to constrain the fibre by decreasing its size to ca. 17 μm (right panel). c, The cell maintained the shape of the fibre spiral while still actively extending pseudopodia (left panel), but after more than three hours after the initial bending event at time \:t, the macrophage seemed to allow unwinding of the nanowire with the tips poking and stretching the cell membrane (right panel). Scale bars in a-c represent 10 μm. d and e, Early time-point (top panel) and late time-point (bottom panel) of macrophages cleansing the fibre-covered surface from nanowires from the Ag-NWs-40 variant, taken ca. 4 h apart. The highlighted areas, covered with nanowires at the beginning, were cleared of fibres during the observation time. The macrophages visibly appear to have increased their fibre load. Scale bars 20 μmCC BY · PubMed Central
Fig. 3 Molecular nanomachinery driving pseudopod arcing and fibre bending. a, A fibre is bend into an arc by a pseudopod extended by the macrophage that suspends the fibre. b, Within the pseudopod, stress filaments work together in causing an elastic deformation that drives rotational movement of its tip and bending of the suspended fibre. c, Actomyosin structures in the stress filaments generate its contraction/extension [30–34]
Fig. 3 Molecular nanomachinery driving pseudopod arcing and fibre bending. a, A fibre is bend into an arc by a pseudopod extended by the macrophage that suspends the fibre. b, Within the pseudopod, stress filaments work together in causing an elastic deformation that drives rotational movement of its tip and bending of the suspended fibre. c, Actomyosin structures in the stress filaments generate its contraction/extension [30–34]CC BY · PubMed Central
Fig. 4 Bending model used to simulate fibre bending by a macrophage. The NR8383 macrophage is represented by a circle of diameter dAM at which the fixation point a0 of a pseudopod of length \ell is placed. Bending by individual stress filaments occurs at N positions points a1, …, aN distributed equidistantly along \ell. A discrete force distribution P(a1, …, aN) is applied at the anchor points, with the case of N = 6 being shown. The force always applies perpendicular to the local fibre segments. This way, the fibre is bend into an arc, with the slope y’(x) determining the bending line y(x). Local angle of deflection \:{\theta}_{B,N}(x) opens up between x-axis and tangent of the local fibre segment. An iterative approach to solve the bending system was employed that is described in more detail in Appendix B
Fig. 4 Bending model used to simulate fibre bending by a macrophage. The NR8383 macrophage is represented by a circle of diameter dAM at which the fixation point a0 of a pseudopod of length \ell is placed. Bending by individual stress filaments occurs at N positions points a1, …, aN distributed equidistantly along \ell. A discrete force distribution P(a1, …, aN) is applied at the anchor points, with the case of N = 6 being shown. The force always applies perpendicular to the local fibre segments. This way, the fibre is bend into an arc, with the slope y’(x) determining the bending line y(x). Local angle of deflection \:{\theta}_{B,N}(x) opens up between x-axis and tangent of the local fibre segment. An iterative approach to solve the bending system was employed that is described in more detail in Appendix BCC BY · PubMed Central
Fig. 5 Application of the bending model to simulate observed bending dynamics and predict critical rigidity range. a, b, Deflection curves calculated with the iterative bending model overlaying the microscopical images, which were rotated so that the fibre near the pseudopod base aligned horizontally. In all calculations, anchor points were distributed over the maximum observed pseudopod length of 25 μm, only every 2nd being shown as black dots. The grid applies to both cell images and plots. Each grid line represents a distance of 10 μm. The force profile was determined using the average values for the stress filament architecture as discussed in Material and Methods: Nmyo = 20, Nactin = 20 and fmyo = 4 pN and \:\nu\: = 0.45, which yields P(a1) = P1 = 0.72. a and b show the bending event of a fibre with a rigidity of \:\mathcal{R}=20 mN·nm² seven and nine min after initialization of phagocytosis at time t, respectively, overlayed by calculated deflection curves in yellow with bending applied respectively to the first 10 and 18 anchor points, respectively. The exterior unbent section of the fibre is represented by the tangent at the last anchor point. c, Concept of determination of critical rigidity. The red circle denotes the cell, black lines the fibre in unbent and bent states, and red lines the pseudopod in straight and arced form. Black dots along the pseudopod represent stress filaments serving as anchor points for the applied bending force. A hyperbolic force profile is plotted (see Appendix A), each value corresponding to the anchor point below. Osculating circles (blue) fitted to the bending line near anchor points are shown for front and rear fibre sections. The average osculating circle fits within the cell, indicating successful bending and a rigidity below the assumed critical threshold. d, Boundary cases enabling definition of a critical rigidity range. For the blue case, the lower bound of the bending force and the reported cell size for the inactive macrophage was used, the upper bound of the bending force and observed maximum distorted cell size for the red case. A critical rigidity range of ca. 3–62 mN·nm² can be predicted
Fig. 5 Application of the bending model to simulate observed bending dynamics and predict critical rigidity range. a, b, Deflection curves calculated with the iterative bending model overlaying the microscopical images, which were rotated so that the fibre near the pseudopod base aligned horizontally. In all calculations, anchor points were distributed over the maximum observed pseudopod length of 25 μm, only every 2nd being shown as black dots. The grid applies to both cell images and plots. Each grid line represents a distance of 10 μm. The force profile was determined using the average values for the stress filament architecture as discussed in Material and Methods: Nmyo = 20, Nactin = 20 and fmyo = 4 pN and \:\nu\: = 0.45, which yields P(a1) = P1 = 0.72. a and b show the bending event of a fibre with a rigidity of \:\mathcal{R}=20 mN·nm² seven and nine min after initialization of phagocytosis at time t, respectively, overlayed by calculated deflection curves in yellow with bending applied respectively to the first 10 and 18 anchor points, respectively. The exterior unbent section of the fibre is represented by the tangent at the last anchor point. c, Concept of determination of critical rigidity. The red circle denotes the cell, black lines the fibre in unbent and bent states, and red lines the pseudopod in straight and arced form. Black dots along the pseudopod represent stress filaments serving as anchor points for the applied bending force. A hyperbolic force profile is plotted (see Appendix A), each value corresponding to the anchor point below. Osculating circles (blue) fitted to the bending line near anchor points are shown for front and rear fibre sections. The average osculating circle fits within the cell, indicating successful bending and a rigidity below the assumed critical threshold. d, Boundary cases enabling definition of a critical rigidity range. For the blue case, the lower bound of the bending force and the reported cell size for the inactive macrophage was used, the upper bound of the bending force and observed maximum distorted cell size for the red case. A critical rigidity range of ca. 3–62 mN·nm² can be predictedCC BY · PubMed Central
Fig. 6 Flow scheme of the iterative determination of the deflection curve representing the arcing fibre section subject to a bending pseudopod
Fig. 6 Flow scheme of the iterative determination of the deflection curve representing the arcing fibre section subject to a bending pseudopodCC BY · PubMed Central

Verification

Claims the paper makes

4 Valid · 3 Not valid · 21 Not checked · 62 Own results and interpretations

28 more claims

Create a free account to see all 90 claims and to verify the 42 references still open.

See all claims — free account
  • It may state two separate claims as one. 26
  • Probably not a substantial claim. 35
  • The quote only partly states this claim. 3

Create a free account to see these claims.

Citations

Cites

Show all 48 references

Research works printed but not linked: 2

  1. Broßell D, Meyer-Plath A, Kämpf K, Plitzko S, Wohlleben W, Stahlmecke B, et al. In: Wagterveld RM, editor. A human risk banding scheme for high aspect-ratio materials. Synthetic Nano- and Microfibers: WETSUS; 2020. pp. 55–80.
  2. OECD. Test No. 125: nanomaterial particle size and size distribution of nanomaterials. OECD Guidelines for the Testing of Chemicals, Sect. 1. Paris: OECD Publishing; 2023.

Cited by

See all 4

Metadata

Authors
Broßell, D., Meyer-Plath, A., Gräb, O., Heunisch, E., Kämpf, K., Haase, A., & Wiemann, M.
Affiliations
  • Humboldt-Universität zu Berlin (DE)
  • Federal Institute for Occupational Safety and Health (DE)
  • German Federal Institute for Risk Assessment (BfR) (DE)
Corresponding author
Broßell, Dirk
Venue
Particle and Fibre Toxicology
Published
2026-03-18
Volume
23
Issue
1
ISSN
1743-8977 (ISSN-L)
OpenAlex
W7138041834
Cited by
2
References
45
Citations by year
2026: 2
FWCI
3.42
Type
journal article
Language
en
Open access
Licence
Locations
  • Particle and Fibre Toxicology (publishedVersion, cc-by)
  • Research Square (acceptedVersion, cc-by)
  • PubMed Central (publishedVersion, cc-by)
  • PubMed (publishedVersion)
  • DOAJ (DOAJ: Directory of Open Access Journals) (submittedVersion, cc-by-sa)
  • OpenAgrar (submittedVersion, cc-by)
Funders
Bundesanstalt für Arbeitsschutz und Arbeitsmedizin (BAuA)
Topics
  • Physical Sciences › Engineering › Biomedical Engineering › Graphene and Nanomaterials Applications
  • Health Sciences › Medicine › Pulmonary and Respiratory Medicine › Occupational and environmental lung diseases
  • Life Sciences › Biochemistry, Genetics and Molecular Biology › Cell Biology › Cellular Mechanics and Interactions
Keywords
alveolar macrophages, phagocytosis, silver nanowires, fiber length, cytoskeleton mechanics, fiber buckling, nanomaterial toxicity, mechanical modelling
MeSH terms
Animals, Cell Line, Models, Biological, Particle Size, Phagocytosis, Silver, Macrophages, Alveolar, Rats, Nanowires, Time-Lapse Imaging

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

The claim verdicts this report counts are experimental: their accuracy is not yet measured.

A language model drew the claims from the paper on 2026-10-11, under version 3 of the claim definition (model deepseek-v4.1-flash, prompt extract-v3).

A second model labelled each claim on 2026-10-11 (model jev-1.13-20260917, definition revision gold-guideline-v0.2).

Cited sources are checked with a language model’s help (gpt-6-sol and qwen3.8-omni-flash).

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Macrophages bend long fibres with flexural rigidity lower than 3 mN·nm2 to avoid frustrated phagocytosis. https://app.cochat.ai/papers/10.1186/s12989-026-00666-9
The paper
Broßell, D., Meyer-Plath, A., Gräb, O., Heunisch, E., Kämpf, K., Haase, A., & Wiemann, M. (2026). Macrophages bend long fibres with flexural rigidity lower than 3 mN·nm2 to avoid frustrated phagocytosis. Particle and Fibre Toxicology. https://doi.org/10.1186/s12989-026-00666-9

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.