Student or educator? Sign up with your school email and get 6 months of Pro free.
CoChat

The DOI matches its Crossref record; 29 of the 29 references it cites were found in a registry or an index.

Reverse transcriptase droplet digital PCR shows high resilience to PCR inhibitors from plant, soil and water samples

Open access
Rački, Nejc, Dreo, Tanja, Gutierrez-Aguirre, Ion, Blejec, Andrej, Ravnikar, Maja · 2014 · Plant Methods

Abstract

BACKGROUND: Detection and quantification of plant pathogens in the presence of inhibitory substances can be a challenge especially with plant and environmental samples. Real-time quantitative PCR has enabled high-throughput detection and quantification of pathogens; however, its quantitative use is linked to standardized reference materials, and its sensitivity to inhibitors can lead to lower quantification accuracy. Droplet digital PCR has been proposed as a method to overcome these drawbacks. Its absolute quantification does not rely on standards and its tolerance to inhibitors has been demonstrated mostly in clinical samples. Such features would be of great use in agricultural and environmental fields, therefore our study compared the performance of droplet digital PCR method when challenged with inhibitors common to plant and environmental samples and compared it with quantitative PCR. RESULTS: Transfer of an existing Pepper mild mottle virus assay from reverse transcription real-time quantitative PCR to reverse transcription droplet digital PCR was straight forward. When challenged with complex matrices (seeds, plants, soil, wastewater) and selected purified inhibitors droplet digital PCR showed higher resilience to inhibition for the quantification of an RNA virus (Pepper mild mottle virus), compared to reverse transcription real-time quantitative PCR. CONCLUSIONS: This study confirms the improved detection and quantification of the PMMoV RT-ddPCR in the presence of inhibitors that are commonly found in samples of seeds, plant material, soil, and wastewater. Together with absolute quantification, independent of standard reference materials, this makes droplet digital PCR a valuable tool for detection and quantification of pathogens in inhibition prone samples.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1186/s13007-014-0042-6

Cites

29 of 29 references verified0 citation errors · 0 not checkable

Statistics

Figures

Figure 1 RT-qPCR and RT-ddPCR parallel analysis of PMMoV RNA serial dilutions. (A) Correlation between the log serial dilutions and determined concentrations (log target/10 μl reaction mixture) for the RT-qPCR and RT-ddPCR. For each method, the linear regression is plotted, with the equation for the correlation coefficient (R2) given. (B) Coefficients of variation for the measurement of each of the serial dilutions within the linear range. The dotted horizontal line indicates the maximal acceptable coefficient of variation for the determination of the limit of quantification.
Figure 1 RT-qPCR and RT-ddPCR parallel analysis of PMMoV RNA serial dilutions. (A) Correlation between the log serial dilutions and determined concentrations (log target/10 μl reaction mixture) for the RT-qPCR and RT-ddPCR. For each method, the linear regression is plotted, with the equation for the correlation coefficient (R2) given. (B) Coefficients of variation for the measurement of each of the serial dilutions within the linear range. The dotted horizontal line indicates the maximal acceptable coefficient of variation for the determination of the limit of quantification.CC BY · PubMed Central
Figure 2 Mean signals of the positive and negative droplets from the RT-ddPCR for detection of PMMoV in samples spiked with serial dilutions of the inhibitor extracts from the selected matrices and from the chemical inhibitors. NIC, target RNA with no inhibitors; H, M, L, (VL), high, medium, low (and very low) concentrations of the inhibitor extracts, respectively. Three technical repeats were analyzed for each sample and inhibitor concentration. Error bars represent standard deviation of each signal.
Figure 2 Mean signals of the positive and negative droplets from the RT-ddPCR for detection of PMMoV in samples spiked with serial dilutions of the inhibitor extracts from the selected matrices and from the chemical inhibitors. NIC, target RNA with no inhibitors; H, M, L, (VL), high, medium, low (and very low) concentrations of the inhibitor extracts, respectively. Three technical repeats were analyzed for each sample and inhibitor concentration. Error bars represent standard deviation of each signal.CC BY · PubMed Central
Figure 3 Mean copies per partition (lambda) determined in the control sample (NIC) with no inhibitor added and in the samples spiked with serial dilutions of the inhibitor extracts from the selected matrices and from the chemical inhibitors. H, M, L, (VL), high, medium, low (and very low) concentrations of inhibitors, respectively. Black line denotes the mean value of lambda for NIC.
Figure 3 Mean copies per partition (lambda) determined in the control sample (NIC) with no inhibitor added and in the samples spiked with serial dilutions of the inhibitor extracts from the selected matrices and from the chemical inhibitors. H, M, L, (VL), high, medium, low (and very low) concentrations of inhibitors, respectively. Black line denotes the mean value of lambda for NIC.CC BY · PubMed Central
Figure 4 Influence of the samples spiked with serial dilutions of the inhibitor extracts on the PMMoV quantification by RT-qPCR (blue traces - diamonds) and RT-ddPCR (green traces - triangles). H, M, L, high, medium, low concentrations of inhibitors, respectively. The PMMoV concentrations are shown relative to those in the no-inhibition control, where 100% inhibition represents total inhibition (no positive signal obtained), and 0% inhibition represents no inhibition (target concentration the same as the no-inhibition control). (A) seed extract. (B) green plant extract. (C) soil extract. (D) wastewater effluent. The measurements were carried out in triplicate. Average values of the measurements for each method are connected by traces for better clarity. Asterisks (*) above each chart denote significantly (p < 0.05) different measurements, compared to 0% inhibition (no inhibition control) ± 10%; blue * for RT-qPCR and green * for RT-ddPCR.
Figure 4 Influence of the samples spiked with serial dilutions of the inhibitor extracts on the PMMoV quantification by RT-qPCR (blue traces - diamonds) and RT-ddPCR (green traces - triangles). H, M, L, high, medium, low concentrations of inhibitors, respectively. The PMMoV concentrations are shown relative to those in the no-inhibition control, where 100% inhibition represents total inhibition (no positive signal obtained), and 0% inhibition represents no inhibition (target concentration the same as the no-inhibition control). (A) seed extract. (B) green plant extract. (C) soil extract. (D) wastewater effluent. The measurements were carried out in triplicate. Average values of the measurements for each method are connected by traces for better clarity. Asterisks (*) above each chart denote significantly (p < 0.05) different measurements, compared to 0% inhibition (no inhibition control) ± 10%; blue * for RT-qPCR and green * for RT-ddPCR.CC BY · PubMed Central
Figure 5 Influence of the samples spiked with serial dilutions of the chemical inhibitors on the PMMoV quantification by RT-qPCR (blue traces - diamonds) and RT-ddPCR (green traces - triangles). H, M, L, (VL), high, medium, low (and very low) concentrations of inhibitors, respectively. The PMMoV concentrations are shown relative to those in the no-inhibition control, where 100% inhibition represents total inhibition (no positive signal obtained), and 0% inhibition represents no inhibition (target concentration the same as the no-inhibition control). (A) dextran sulfate. (B) pectin. (C) tannic acid. (D) humic acid. The measurements were carried out in triplicate. Average values of the measurements for each method are connected by traces for better clarity. Asterisks (*) above each chart denote significantly (p < 0.05) different measurements, compared to 0% inhibition (no inhibition control) ± 10%; blue *for RT-qPCR and green *for RT-ddPCR.
Figure 5 Influence of the samples spiked with serial dilutions of the chemical inhibitors on the PMMoV quantification by RT-qPCR (blue traces - diamonds) and RT-ddPCR (green traces - triangles). H, M, L, (VL), high, medium, low (and very low) concentrations of inhibitors, respectively. The PMMoV concentrations are shown relative to those in the no-inhibition control, where 100% inhibition represents total inhibition (no positive signal obtained), and 0% inhibition represents no inhibition (target concentration the same as the no-inhibition control). (A) dextran sulfate. (B) pectin. (C) tannic acid. (D) humic acid. The measurements were carried out in triplicate. Average values of the measurements for each method are connected by traces for better clarity. Asterisks (*) above each chart denote significantly (p < 0.05) different measurements, compared to 0% inhibition (no inhibition control) ± 10%; blue *for RT-qPCR and green *for RT-ddPCR.CC BY · PubMed Central

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 29 references

Research works printed but not linked: 1

  1. Peist R, Honsel D, Twieling G, Löffert D: PCR inhibitors in plant DNA preparations. QIAGEN news. 2001, 3: 7-9.

Cited by

See all 276

Metadata

Authors
Rački, N., Dreo, T., Gutierrez-Aguirre, I., Blejec, A., & Ravnikar, M.
Affiliations
National Institute of Biology (SI)
Corresponding author
Rački, Nejc
Venue
Plant Methods
Published
2014-12
Volume
10
Issue
1
Pages
42-42
ISSN
1746-4811 (ISSN-L)
OpenAlex
W2100347303
Cited by
257
References
29
Citations by year
2026: 18 · 2025: 20 · 2024: 32 · 2023: 20 · 2022: 26 · 2021: 34 · 2020: 28 · 2019: 25 · 2018: 24 · 2017: 11 · 2016: 15 · 2015: 4
FWCI
4.10
Type
journal article
Language
en
Open access
Locations
  • Plant Methods (publishedVersion, cc-by)
  • Europe PMC (PubMed Central) (publishedVersion, cc-by)
  • PubMed Central (publishedVersion, cc-by)
  • PubMed (publishedVersion)
  • DiRROS repository (University of Maribor) (publishedVersion, cc-by)
Funders
  • Javna Agencija za Raziskovalno Dejavnost RS (L2-4314)
  • Univerza v Ljubljani
  • Urad Republike Slovenije za Meroslovje
  • European Regional Development Fund
Topics
  • Life Sciences › Biochemistry, Genetics and Molecular Biology › Molecular Biology › Molecular Biology Techniques and Applications
  • Life Sciences › Agricultural and Biological Sciences › Plant Science › Plant Virus Research Studies
  • Health Sciences › Medicine › Infectious Diseases › SARS-CoV-2 detection and testing
Keywords
droplet digital PCR, PCR inhibitors, reverse transcription, pepper mild mottle virus, plant pathogen detection, absolute quantification, soil sample, wastewater, plant viruses

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Reverse transcriptase droplet digital PCR shows high resilience to PCR inhibitors from plant, soil and water samples. https://app.cochat.ai/papers/10.1186/s13007-014-0042-6
The paper
Rački, N., Dreo, T., Gutierrez-Aguirre, I., Blejec, A., & Ravnikar, M. (2014). Reverse transcriptase droplet digital PCR shows high resilience to PCR inhibitors from plant, soil and water samples. Plant Methods. https://doi.org/10.1186/s13007-014-0042-6

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.