Does inferior vena cava respiratory variability predict fluid responsiveness in spontaneously breathing patients?
Open accessThe DOI matches its Crossref record; 33 of the 33 references it cites were found in a registry or an index.
Abstract
Introduction: We have almost no information concerning the value of inferior vena cava (IVC) respiratory variations in spontaneously breathing ICU patients (SBP) to predict fluid responsiveness. Methods: SBP with clinical fluid need were included prospectively in the study. Echocardiography and Doppler ultrasound were used to record the aortic velocity-time integral (VTI), stroke volume (SV), cardiac output (CO) and IVC collapsibility index (cIVC) ((maximum diameter (IVCmax)– minimum diameter (IVCmin))/ IVCmax) at baseline, after a passive leg-raising maneuver (PLR) and after 500 ml of saline infusion. Results: Fifty-nine patients (30 males and 29 females; 57 ± 18 years-old) were included in the study. Of these, 29 (49 %) were considered to be responders (≥10 % increase in CO after fluid infusion). There were no significant differences between responders and nonresponders at baseline, except for a higher aortic VTI in nonresponders (16 cm vs. 19 cm, p = 0.03). Responders had a lower baseline IVCmin than nonresponders (11 ± 5 mm vs. 14 ± 5 mm, p = 0.04) and more marked IVC variations (cIVC: 35 ± 16 vs. 27 ± 10 %, p = 0.04). Prediction of fluid-responsiveness using cIVC and IVCmax was low (area under the curve for cIVC at baseline 0.62 ± 0.07; 95 %, CI 0.49-0.74 and for IVCmax at baseline 0.62 ± 0.07; 95 % CI 0.49-0.75). In contrast, IVC respiratory variations >42 % in SBP demonstrated a high specificity (97 %) and a positive predictive value (90 %) to predict an increase in CO after fluid infusion. Conclusions: In SBP with suspected hypovolemia, vena cava size and respiratory variability do not predict fluid responsiveness. In contrast, a cIVC >42 % may predict an increase in CO after fluid infusion.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Lang, R. M., Bierig, M., Devereux, R. B., Flachskampf, F. A., Foster, E., Pellikka, P. A., Picard, M. H., Roman, M. J., Seward, J., Shanewise, J. S., et al. (2005) · Journal of the American Society of Echocardiography · doi:10.1016/j.echo.2005.10.005 · Cited by 11,318
Surviving Sepsis Campaign: International Guidelines for Management of Severe Sepsis and Septic Shock
Dellinger, R. P., Levy, M. M., Rhodes, A., Annane, D., Gerlach, H., Opal, S. M., Sevransky, J. E., Sprung, C. L., Douglas, I. S., Jaeschke, R., et al. (2013) · Critical Care Medicine · doi:10.1097/ccm.0b013e31827e83af · Cited by 9,694
Dellinger, R. P., Levy, M. M., Carlet, J. M., Bion, J., Parker, M. M., Jaeschke, R., Reinhart, K., Angus, D. C., Brun-Buisson, C., Beale, R., et al. (2008) · Intensive Care Medicine · doi:10.1007/s00134-007-0934-2 · Cited by 6,772
Comparison of Two Fluid-Management Strategies in Acute Lung Injury
(2006) · New England Journal of Medicine · doi:10.1056/nejmoa062200 · Cited by 3,538
Marik, P. E., Baram, M., & Vahid, B. (2008) · Chest · doi:10.1378/chest.07-2331 · Cited by 1,516 · cited 1×
“Although an international working group [2] recently recommended the use of CVP as a marker of fluid responsiveness, this approach is highly controversial in ICU patients with shock [1, 8, 30].”
MethodPredicting Fluid Responsiveness in ICU Patients
Michard, F., & Teboul, J.-L. (2002) · Chest · doi:10.1378/chest.121.6.2000 · Cited by 1,367
Kircher, B. J., Himelman, R. B., & Schiller, N. B. (1990) · The American Journal of Cardiology · doi:10.1016/0002-9149(90)90711-9 · Cited by 1,027 · cited 2×
“Many researchers have reported a good correlation between RAP and IVC respiratory variability in spontaneously breathing patients [25–29].”
BackgroundThe respiratory variation in inferior vena cava diameter as a guide to fluid therapy
Feissel, M., Michard, F., Faller, J.-P., & Teboul, J.-L. (2004) · Intensive Care Medicine · doi:10.1007/s00134-004-2233-5 · Cited by 967 · cited 3×
“increases only slightly) [12, 13].”
BackgroundBarbier, C., Loubières, Y., Schmit, C., Hayon, J., Ricôme, J.-L., Jardin, F., & Vieillard-Baron, A. (2004) · Intensive Care Medicine · doi:10.1007/s00134-004-2259-8 · Cited by 940 · cited 1×
“[13] demonstrated that IVC variations were closely correlated with the CO increase after fluid infusion.”
BackgroundMayo, P. H., Beaulieu, Y., Doelken, P., Feller-Kopman, D., Harrod, C., Kaplan, A., Oropello, J., Vieillard-Baron, A., Axler, O., Lichtenstein, D., et al. (2009) · Chest · doi:10.1378/chest.08-2305 · Cited by 736 · cited 1×
“, hypovolemia, heart failure and vasoplegia) [16–18].”
Self-citationCardiac filling pressures are not appropriate to predict hemodynamic response to volume challenge*
Osman, D., Ridel, C., Ray, P., Monnet, X., Anguel, N., Richard, C., & Teboul, J.-L. (2007) · Critical Care Medicine · doi:10.1097/01.ccm.0000249851.94101.4f · Cited by 695 · cited 3×
“Recent research has also demonstrated that standard static hemodynamic measurements (such as central venous pressure or pulmonary artery occlusion pressure) are of little value in predicting fluid responsiveness [1, 8].”
BackgroundMethodFeissel, M., Michard, F., Mangin, I., Ruyer, O., Faller, J.-P., & Teboul, J.-L. (2001) · CHEST · doi:10.1378/chest.119.3.867 · Cited by 612 · cited 2×
“Many studies have focused on the prediction of fluid responsiveness, and many different dynamic markers of fluid responsiveness have been studied in recent years [1, 5–7].”
BackgroundSuperior vena caval collapsibility as a gauge of volume status in ventilated septic patients
Vieillard-Baron, A., Chergui, K., Rabiller, A., Peyrouset, O., Page, B., Beauchet, A., & Jardin, F. (2004) · Intensive Care Medicine · doi:10.1007/s00134-004-2361-y · Cited by 476 · cited 1×
“demonstrated that the superior vena cava collapsibility index (recorded via transesophageal echocardiography) was very effective for assessing fluid needs in shocked and mechanically ventilated patients [31].”
BackgroundReappraisal of the Use of Inferior Vena Cava for Estimating Right Atrial Pressure
Brennan, J. M., Blair, J. E., Goonewardena, S., Ronan, A., Shah, D., Vasaiwala, S., Kirkpatrick, J. N., & Spencer, K. T. (2007) · Journal of the American Society of Echocardiography · doi:10.1016/j.echo.2007.01.005 · Cited by 459 · cited 1×
“[29] reappraised the use of IVC variations to estimate the RAP; they analyzed IVCmax, IVCmin and cIVC during passive respiration and during a sniff test in which the patient was asked to perform a brief, rapid inspiration [29].”
MethodInternational expert statement on training standards for critical care ultrasonography
Expert Round Table on Ultrasound in, I. C. U. (2011) · Intensive Care Medicine · doi:10.1007/s00134-011-2246-9 · Cited by 387
Muller, L., Bobbia, X., Toumi, M., Louart, G., Molinari, N., Ragonnet, B., Quintard, H., Leone, M., Zoric, L., Lefrant, J. Y., et al. (2012) · Critical Care · doi:10.1186/cc11672 · Cited by 374 · cited 1×
“However, data on the accuracy of IVC variations for predicting fluid needs in spontaneously breathing patients are scarce [14].”
BackgroundNegative Fluid Balance Predicts Survival in Patients With Septic Shock
Alsous, F., Khamiees, M., DeGirolamo, A., Amoateng-Adjepong, Y., & Manthous, C. A. (2000) · Chest · doi:10.1378/chest.117.6.1749 · Cited by 344 · cited 1×
“In septic shock, fluid infusion is usually recommended [2] but may be harmful particularly in patients with acute respiratory distress syndrome [3, 4].”
BackgroundMoreno, F. L. L., Hagan, A. D., Holmen, J. R., Pryor, T. A., Strickland, R. D., & Castle, C. H. (1984) · The American Journal of Cardiology · doi:10.1016/0002-9149(84)90034-1 · Cited by 308 · cited 1×
“These parameters were found to be well correlated with RAP in spontaneously breathing patients [23, 24].”
BackgroundDiagnosis of central hypovolemia by using passive leg raising
Maizel, J., Airapetian, N., Lorne, E., Tribouilloy, C., Massy, Z., & Slama, M. (2007) · Intensive Care Medicine · doi:10.1007/s00134-007-0642-y · Cited by 297 · cited 1×
“Over the last decade, dynamic measurements (rather than static measurements) have become popular for predicting fluid responsiveness [1, 5–7, 12–16, 30–34].”
BackgroundSelf-citationNagueh, S. F., Kopelen, H. A., & Zoghbi, W. A. (1996) · Circulation · doi:10.1161/01.cir.93.6.1160 · Cited by 280 · cited 1×
“synchronization in a short-axis view, 2 cm below the right atrium) or at end-expiration (without ECG synchronization, using the two-dimensional long-axis view at the same location in the supine position) [10, 11, 21, 22].”
MethodInternational expert statement on training standards for critical care ultrasonography
Anel, E. P. (2011) · Cited by 276
Stawicki, S. P., Braslow, B. M., Panebianco, N. L., Kirkpatrick, J. N., Gracias, V. H., Hayden, G. E., & Dean, A. J. (2009) · Journal of the American College of Surgeons · doi:10.1016/j.jamcollsurg.2009.02.062 · Cited by 260 · cited 1×
“Many researchers have reported a good correlation between RAP and IVC respiratory variability in spontaneously breathing patients [25–29].”
BackgroundMonnet, X., Bleibtreu, A., Ferré, A., Dres, M., Gharbi, R., Richard, C., & Teboul, J.-L. (2012) · Critical Care Medicine · doi:10.1097/ccm.0b013e31822f08d7 · Cited by 246 · cited 2×
“Many studies have focused on the prediction of fluid responsiveness, and many different dynamic markers of fluid responsiveness have been studied in recent years [1, 5–7].”
BackgroundJue, J., Chung, W., & Schiller, N. B. (1992) · Journal of the American Society of Echocardiography · doi:10.1016/s0894-7317(14)80327-1 · Cited by 193 · cited 1×
“synchronization in a short-axis view, 2 cm below the right atrium) or at end-expiration (without ECG synchronization, using the two-dimensional long-axis view at the same location in the supine position) [10, 11, 21, 22].”
MethodMintz, G. S., Kotler, M. N., Parry, W. R., Iskandrian, A. S., & Kane, S. A. (1981) · Circulation · doi:10.1161/01.cir.64.5.1018 · Cited by 181 · cited 1×
“These parameters were found to be well correlated with RAP in spontaneously breathing patients [23, 24].”
BackgroundRespiratory variations of aortic VTI: a new index of hypovolemia and fluid responsiveness
Slama, M., Masson, H., Teboul, J.-L., Arnout, M.-L., Susic, D., Frohlich, E., & Andrejak, M. (2002) · American Journal of Physiology-Heart and Circulatory Physiology · doi:10.1152/ajpheart.00308.2002 · Cited by 172 · cited 2×
“Many studies have focused on the prediction of fluid responsiveness, and many different dynamic markers of fluid responsiveness have been studied in recent years [1, 5–7].”
BackgroundSelf-citationNakao, S., Come, P. C., McKay, R. G., & Ransil, B. J. (1987) · The American Journal of Cardiology · doi:10.1016/s0002-9149(87)80084-x · Cited by 136 · cited 1×
“synchronization in a short-axis view, 2 cm below the right atrium) or at end-expiration (without ECG synchronization, using the two-dimensional long-axis view at the same location in the supine position) [10, 11, 21, 22].”
MethodPrediction of volume responsiveness in critically ill patients with spontaneous breathing activity
Teboul, J., & Monnet, X. (2008) · Current Opinion in Critical Care · doi:10.1097/mcc.0b013e3282fd6e1e · Cited by 121 · cited 1×
“The bed was then automatically moved to induce PLR of 30° [15]; blood pressure values, HR, IVC diameters and CO were measured two minutes later.”
MethodMandeville, J., & Colebourn, C. L. (2012) · Critical Care Research and Practice · doi:10.1155/2012/513480 · Cited by 90 · cited 1×
“Over the last decade, dynamic measurements (rather than static measurements) have become popular for predicting fluid responsiveness [1, 5–7, 12–16, 30–34].”
BackgroundBendjelid, K., Romand, J.-A., Walder, B., Suter, P. M., & Fournier, G. (2002) · Journal of the American Society of Echocardiography · doi:10.1067/mje.2002.120701 · Cited by 75 · cited 1×
“synchronization in a short-axis view, 2 cm below the right atrium) or at end-expiration (without ECG synchronization, using the two-dimensional long-axis view at the same location in the supine position) [10, 11, 21, 22].”
MethodArthur, M. E., Landolfo, C. K., Wade, M., & Castresana, M. R. (2008) · Echocardiography · doi:10.1111/j.1540-8175.2008.00772.x · Cited by 58 · cited 1×
“The IVC diameter at the cavoatrial junction was also used to estimate CVP in a large cohort of mechanically ventilated patients [9], with a good correlation with RAP.”
MethodEffect of inspiration on inferior vena caval blood flow in dogs
Lloyd, T. C. (1983) · Journal of Applied Physiology · doi:10.1152/jappl.1983.55.6.1701 · Cited by 41
Venous collapse and the respiratory variability in systemic venous return
Amoore, J., & Santamore, W. P. (1994) · Cardiovascular Research · doi:10.1093/cvr/28.4.472 · Cited by 23 · cited 1×
“Many researchers have reported a good correlation between RAP and IVC respiratory variability in spontaneously breathing patients [25–29].”
Background
Cited by
Prediction of fluid responsiveness: an update
Monnet, X., Marik, P. E., & Teboul, J.-L. (2016) · Annals of Intensive Care · doi:10.1186/s13613-016-0216-7 · Cited by 600
Will This Hemodynamically Unstable Patient Respond to a Bolus of Intravenous Fluids?
Bentzer, P., Griesdale, D. E., Boyd, J., MacLean, K., Sirounis, D., & Ayas, N. T. (2016) · JAMA · doi:10.1001/jama.2016.12310 · Cited by 329
Via, G., Tavazzi, G., & Price, S. (2016) · Intensive Care Medicine · doi:10.1007/s00134-016-4357-9 · Cited by 247
“Introduction Assessment of the size of the inferior vena cava (IVC) and its change in diameter in response to respiration have been investigated as a tool to screen for severe hypovolaemia [1], predict fluid responsiveness (FR) [2, 3] and assess potential intolerance to fluid loading.”
BackgroundOrso, D., Paoli, I., Piani, T., Cilenti, F. L., Cristiani, L., & Guglielmo, N. (2020) · Journal of Intensive Care Medicine · doi:10.1177/0885066617752308 · Cited by 223
Long, E., Oakley, E., Duke, T., & Babl, F. E. (2017) · Shock · doi:10.1097/shk.0000000000000801 · Cited by 200
Metadata
- Authors
- Airapetian, N., Maizel, J., Alyamani, O., Mahjoub, Y., Lorne, E., Levrard, M., Ammenouche, N., Seydi, A., Tinturier, F., Lobjoie, E., Dupont, H., & Slama, M.
- Venue
- Critical Care
- Published
- 2015-12
- Volume
- 19
- Issue
- 1
- Pages
- 400-400
- ISSN
- 1364-8535 (ISSN-L)
- OpenAlex
- W2172709435
- Cited by
- 246
- References
- 33
- FWCI
- 21.51
- Type
- journal article
- Language
- en
- Open access
- gold
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.