Measuring energy expenditure in the intensive care unit: a comparison of indirect calorimetry by E-sCOVX and Quark RMR with Deltatrac II in mechanically ventilated critically ill patients
Open accessThe DOI matches its Crossref record; 12 of the 12 references it cites were found in a registry or an index.
Abstract
BACKGROUND: Indirect calorimetry allows the determination of energy expenditure in critically ill patients by measuring oxygen consumption (VO2) and carbon dioxide production (VCO2). Recent studies have demonstrated variable performance of "breath-by-breath" instruments compared to mixing chamber technology. The aim of this study was to validate two modern devices (E-sCOVX and Quark RMR) against a reference method (Deltatrac II). METHOD: Measurements of VO2/VCO2 with the test and reference devices were performed simultaneously over a 20-min period in mechanically ventilated adult intensive care unit patients. Accuracy and precision of instruments were analyzed using Bland-Altman plots. RESULTS: Forty-eight measurements in 22 patients were included for analysis. Both E-sCOVX and Quark RMR overestimated VO2 and VCO2 compared to Deltatrac II, corresponding to a 10% higher mean resting energy expenditure. Limits of agreement of resting energy expenditure within ± 2 standard deviations were ± 461 kcal/24 h (± 21% expressed as percentage error) for ΔE-sCOVX-Deltatrac II and ± 465 kcal/24 h (± 22%) for ΔQuark RMR-Deltatrac II. CONCLUSION: Both test devices overestimate VO2 and VCO2 compared to Deltatrac II. The observed limits of agreement are comparable to those commonly accepted in evaluations of circulatory monitoring, and significantly less than results from predictive equations. We hypothesize that the discrepancy between methods is due to patient/ventilator-related factors that affect the synchronization of gas and spirometry waveforms. TRIAL REGISTRATION: Australian New Zealand Clinical Trials Registry, Trial ID ACTRN12615000205538. Date registered 3 March 2015.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
STATISTICAL METHODS FOR ASSESSING AGREEMENT BETWEEN TWO METHODS OF CLINICAL MEASUREMENT
Martin Bland, J., & Altman, D. (1986) · The Lancet · doi:10.1016/s0140-6736(86)90837-8 · Cited by 47,965
McClave, S. A., Taylor, B. E., Martindale, R. G., Warren, M. M., Johnson, D. R., Braunschweig, C., McCarthy, M. S., Davanos, E., Rice, T. W., Cresci, G. A., et al. (2016) · Journal of Parenteral and Enteral Nutrition · doi:10.1177/0148607115621863 · Cited by 3,982
ESPEN guidelines on parenteral nutrition: intensive care
Singer, P., Berger, M. M., Van den Berghe, G., Biolo, G., Calder, P., Forbes, A., Griffiths, R., Kreyman, G., Leverve, X., & Pichard, C. (2009) · Clinical Nutrition · doi:10.1016/j.clnu.2009.04.024 · Cited by 1,907 · cited 1×
“Several guidelines recommend a calorie delivery targeted to energy expenditure (EE) [1, 2].”
BackgroundMcClave, S. A., Martindale, R. G., Vanek, V. W., McCarthy, M., Roberts, P., Taylor, B., Ochoa, J. B., Napolitano, L., Cresci, G., the A.S.P.E.N. Board of Directors, et al. (2009) · Journal of Parenteral and Enteral Nutrition · doi:10.1177/0148607109335234 · Cited by 1,873
Early versus late parenteral nutrition in critically ill adults
Casaer, M. P., Mesotten, D., Hermans, G., Wouters, P. J., Schetz, M., Meyfroidt, G., Van Cromphaut, S., Ingels, C., Meersseman, P., Muller, J., et al. (2011) · New England Journal of Medicine · doi:10.1056/nejmoa1102662 · Cited by 1,696
Taylor, B. E., McClave, S. A., Martindale, R. G., Warren, M. M., Johnson, D. R., Braunschweig, C., McCarthy, M. S., Davanos, E., Rice, T. W., Cresci, G. A., et al. (2016) · Critical Care Medicine · doi:10.1097/ccm.0000000000001525 · Cited by 1,476
ESPEN guidelines on enteral nutrition: intensive care
Kreymann, K. G., Berger, M. M., Deutz, N. E. P., Hiesmayr, M., Jolliet, P., Kazandjiev, G., Nitenberg, G., van den Berghe, G., Wernerman, J., Ebner, C., et al. (2006) · Clinical Nutrition · doi:10.1016/j.clnu.2006.01.021 · Cited by 1,366
Self-citationThe National Heart, L., Rice, T. W., Wheeler, A. P., Thompson, B. T., Steingrub, J., Hite, R. D., Moss, M., Morris, A., Dong, N., & Rock, P. (2012) · JAMA: The Journal of the American Medical Association · doi:10.1001/jama.2012.137 · Cited by 935
Heidegger, C. P., Berger, M. M., Graf, S., Zingg, W., Darmon, P., Costanza, M. C., Thibault, R., & Pichard, C. (2013) · The Lancet · doi:10.1016/s0140-6736(12)61351-8 · Cited by 776
Permissive underfeeding or standard enteral feeding in critically ill adults
Arabi, Y. M., Aldawood, A. S., Haddad, S. H., Al-Dorzi, H. M., Tamim, H. M., Jones, G., Mehta, S., McIntyre, L., Solaiman, O., Sakkijha, M. H., et al. (2015) · New England Journal of Medicine · doi:10.1056/nejmoa1502826 · Cited by 614
Cited by
Indirect calorimetry in nutritional therapy. A position paper by the ICALIC study group
Oshima, T., Berger, M. M., De Waele, E., Guttormsen, A. B., Heidegger, C.-P., Hiesmayr, M., Singer, P., Wernerman, J., & Pichard, C. (2017) · Clinical Nutrition · doi:10.1016/j.clnu.2016.06.010 · Cited by 283
Self-citationZusman, O., Kagan, I., Bendavid, I., Theilla, M., Cohen, J., & Singer, P. (2019) · Clinical Nutrition · doi:10.1016/j.clnu.2018.04.020 · Cited by 143
Can calculation of energy expenditure based on CO2 measurements replace indirect calorimetry?
Oshima, T., Graf, S., Heidegger, C.-P., Genton, L., Pugin, J., & Pichard, C. (2017) · Critical Care · doi:10.1186/s13054-016-1595-8 · Cited by 48
“Recent studies comparing currently available calorimeters have demonstrated that the measured EE is variable from one calorimeter to another [8, 9], although they are still more consistent than the EE calculated from predictive equations [10].”
BackgroundFeeding should be individualized in the critically ill patients
Berger, M. M., & Pichard, C. (2019) · Current Opinion in Critical Care · doi:10.1097/mcc.0000000000000625 · Cited by 37
Metadata
- Authors
- Sundström Rehal, M., Fiskaare, E., Tjäder, I., Norberg, Å., Rooyackers, O., & Wernerman, J.
- Venue
- Critical Care
- Published
- 2016-03-05
- Volume
- 20
- Issue
- 1
- Pages
- 104-104
- ISSN
- 1364-8535 (ISSN-L)
- OpenAlex
- W2294337900
- Cited by
- 47
- References
- 12
- FWCI
- 7.74
- Type
- journal article
- Language
- en
- Open access
- gold
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.