The right ventricle: interaction with the pulmonary circulation
Open accessThe DOI matches its Crossref record; 39 of the 39 references it cites were found in a registry or an index.
Abstract
The primary role of the right ventricle (RV) is to deliver all the blood it receives per beat into the pulmonary circulation without causing right atrial pressure to rise. To the extent that it also does not impede left ventricular (LV) filling, cardiac output responsiveness to increased metabolic demand is optimized. Since cardiac output is a function of metabolic demand of the body, during stress and exercise states the flow to the RV can vary widely. Also, instantaneous venous return varies widely for a constant cardiac output as ventilatory efforts alter the dynamic pressure gradient for venous return. Normally, blood flow varies with minimal changes in pulmonary arterial pressure. Similarly, RV filling normally occurs with minimal increases in right atrial pressure. When pulmonary vascular reserve is compromised RV ejection may also be compromised, increasing right atrial pressure and limiting maximal cardiac output. Acute increases in RV outflow resistance, as may occur with acute pulmonary embolism, will cause acute RV dilation and, by ventricular interdependence, markedly decreased LV diastolic compliance, rapidly spiraling to acute cardiogenic shock and death. Treatments include reversing the causes of pulmonary hypertension and sustaining mean arterial pressure higher than pulmonary artery pressure to maximal RV coronary blood flow. Chronic pulmonary hypertension induces progressive RV hypertrophy to match RV contractility to the increased pulmonary arterial elastance. Once fully developed, RV hypertrophy is associated with a sustained increase in right atrial pressure, impaired LV filling, and decreased exercise tolerance. Treatment focuses on pharmacologic therapies to selectively reduce pulmonary vasomotor tone and diuretics to minimize excessive RV dilation. Owning to the irreversible nature of most forms of pulmonary hypertension, when the pulmonary arterial elastance greatly exceeds the adaptive increase in RV systolic elastance, due to RV dilation, progressive pulmonary vascular obliteration, or both, end stage cor pulmonale ensues. If associated with cardiogenic shock, it can effectively be treated only by artificial ventricular support or lung transplantation. Knowing how the RV adapts to these stresses, its sign posts, and treatment options will greatly improve the bedside clinician's ability to diagnose and treat RV dysfunction.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Rudski, L. G., Lai, W. W., Afilalo, J., Hua, L., Handschumacher, M. D., Chandrasekaran, K., Solomon, S. D., Louie, E. K., & Schiller, N. B. (2010) · Journal of the American Society of Echocardiography · doi:10.1016/j.echo.2010.05.010 · Cited by 7,049
SUGA, H., SAGAWA, K., & SHOUKAS, A. A. (1973) · Circulation Research · doi:10.1161/01.res.32.3.314 · Cited by 1,502 · cited 1×
“However, the most accurate measure of systolic function is time-varying elastance and end-systolic elastance, as a measure of the progressively increasing stiffness that the heart undergoes during contraction [22].”
BackgroundRight Heart Adaptation to Pulmonary Arterial Hypertension
Vonk-Noordegraaf, A., Haddad, F., Chin, K. M., Forfia, P. R., Kawut, S. M., Lumens, J., Naeije, R., Newman, J., Oudiz, R. J., Provencher, S., et al. (2013) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2013.10.027 · Cited by 982
Left ventricular interaction with arterial load studied in isolated canine ventricle
Sunagawa, K., Maughan, W. L., Burkhoff, D., & Sagawa, K. (1983) · American Journal of Physiology-Heart and Circulatory Physiology · doi:10.1152/ajpheart.1983.245.5.h773 · Cited by 817 · cited 1×
“For the left side the mean arterial pressure and the magnitude of the pulse pressure rise for a given stroke volume are also a function of the input arterial resistance, compliance, and impedance [42].”
BackgroundKucher, N., Rossi, E., De Rosa, M., & Goldhaber, S. Z. (2006) · Circulation · doi:10.1161/circulationaha.105.592592 · Cited by 780
Lorenz, C., Walker, E., Morgan, V., Klein, S., & Graham, T. (1999) · Journal of Cardiovascular Magnetic Resonance · doi:10.3109/10976649909080829 · Cited by 717 · cited 1×
“[19].”
The Right Ventricle Under Pressure
Bogaard, H. J., Abe, K., Vonk Noordegraaf, A., & Voelkel, N. F. (2009) · Chest · doi:10.1378/chest.08-0492 · Cited by 679 · cited 1×
“, chronic obstructive lung disease, pulmonary fibrosis, primary pulmonary hypertension) may also become acutely ill [50].”
BackgroundNagendran, J., Archer, S. L., Soliman, D., Gurtu, V., Moudgil, R., Haromy, A., St. Aubin, C., Webster, L., Rebeyka, I. M., Ross, D. B., et al. (2007) · Circulation · doi:10.1161/circulationaha.106.655266 · Cited by 530 · cited 1×
“Drugs such as sildenafil [57] and endothelin receptor blockers may be used.”
Optimal arterial resistance for the maximal stroke work studied in isolated canine left ventricle.
Sunagawa, K., Maughan, W. L., & Sagawa, K. (1985) · Circulation Research · doi:10.1161/01.res.56.4.586 · Cited by 474 · cited 1×
“Accordingly, LV Ea/Ees is a sensitive and independent estimate of the efficiency of the cardiovascular system [46].”
BackgroundVieillard-Baron, A., Schmitt, J.-M., Augarde, R., Fellahi, J. L., Prin, S., Page, B., Beauchet, A., & Jardin, F. (2001) · Critical Care Medicine · doi:10.1097/00003246-200108000-00009 · Cited by 460 · cited 1×
“Reversing pulmonary hyperinflation using bronchodilators and altering ventilator settings to maximize expiratory time and minimize tidal volume and using low tidal volume ventilation will help [64].”
BackgroundVentricular efficiency predicted by an analytical model
Burkhoff, D., & Sagawa, K. (1986) · American Journal of Physiology-Regulatory, Integrative and Comparative Physiology · doi:10.1152/ajpregu.1986.250.6.r1021 · Cited by 405 · cited 1×
“performed for myocardial oxygen consumed, occurs when systemic Ea is approximately one-half LV Ees [44] and shows a stronger dependence on systemic Ea than LV Ees [45].”
BackgroundKuehne, T., Yilmaz, S., Steendijk, P., Moore, P., Groenink, M., Saaed, M., Weber, O., Higgins, C. B., Ewert, P., Fleck, E., et al. (2004) · Circulation · doi:10.1161/01.cir.0000143138.02493.dd · Cited by 369 · cited 1×
“[26]) Pinsky Critical Care (2016) 20:266 Page 6 of 9”
BackgroundRV-pulmonary arterial coupling predicts outcome in patients referred for pulmonary hypertension
Vanderpool, R. R., Pinsky, M. R., Naeije, R., Deible, C., Kosaraju, V., Bunner, C., Mathier, M. A., Lacomis, J., Champion, H. C., & Simon, M. A. (2015) · Heart · doi:10.1136/heartjnl-2014-306142 · Cited by 354
Self-citationSingle-beat estimation of right ventricular end-systolic pressure-volume relationship
Brimioulle, S., Wauthy, P., Ewalenko, P., Rondelet, B., Vermeulen, F., Kerbaul, F., & Naeije, R. (2003) · American Journal of Physiology-Heart and Circulatory Physiology · doi:10.1152/ajpheart.01023.2002 · Cited by 346 · cited 3×
“estimates of RV stroke volume [43].”
InfluentialReliability of clinical monitoring to assess blood volume in critically ill patients
SHIPPY, C. R., APPEL, P. L., & SHOEMAKER, W. C. (1984) · Critical Care Medicine · doi:10.1097/00003246-198402000-00005 · Cited by 342
Echo–Doppler Demonstration of Acute Cor Pulmonale at the Bedside in the Medical Intensive Care Unit
Vieillard-Baron, A., Prin, S., Chergui, K., Dubourg, O., & Jardin, F. (2002) · American Journal of Respiratory and Critical Care Medicine · doi:10.1164/rccm.200202-146cc · Cited by 316 · cited 1×
“[66]”
Instantaneous pressure-volume relationship of the canine right ventricle.
Maughan, W. L., Shoukas, A. A., Sagawa, K., & Weisfeldt, M. L. (1979) · Circulation Research · doi:10.1161/01.res.44.3.309 · Cited by 313
Cyclic changes in right ventricular output impedance during mechanical ventilation
Vieillard-Baron, A., Loubieres, Y., Schmitt, J.-M., Page, B., Dubourg, O., & Jardin, F. (1999) · Journal of Applied Physiology · doi:10.1152/jappl.1999.87.5.1644 · Cited by 303 · cited 1×
“Increases in lung volume independent of changes in pulmonary vasomotor tone can also alter RV function [30, 31].”
BackgroundThe right ventricle: anatomy, physiology, and clinical importance
Dell'Italia, L. J. (1991) · Current Problems in Cardiology · doi:10.1016/0146-2806(91)90009-y · Cited by 300 · cited 1×
“approximately 25–50 ms [20].”
Alveolar Pressure, Pulmonary Venous Pressure, and the Vascular Waterfall
Permutt, S., Bromberger-Barnea, B., & Bane, H. N. (2009) · Medicina Thoracalis · doi:10.1159/000192224 · Cited by 291 · cited 1×
“Under normal conditions RV afterload is highly dependent on the distribution of blood flow in the lung, the degree of hyperinflation or increased alveolar pressure that may be present [29], and active increases in pulmonary vasomotor tone as may occur with inflammation and alveolar hypoxia.”
BackgroundThe relationship between pericardial pressure and right atrial pressure: an intraoperative study.
Tyberg, J. V., Taichman, G. C., Smith, E. R., Douglas, N. W., Smiseth, O. A., & Keon, W. J. (1986) · Circulation · doi:10.1161/01.cir.73.3.428 · Cited by 271 · cited 1×
“[10] measured pericardial pressure and right atrial pressure during acute fluid loading in patients prior to going on cardiopulmonary bypass.”
BackgroundSignificant left ventricular contribution to right ventricular systolic function
Damiano, R. J., La Follette, P., Cox, J. L., Lowe, J. E., & Santamore, W. P. (1991) · American Journal of Physiology-Heart and Circulatory Physiology · doi:10.1152/ajpheart.1991.261.5.h1514 · Cited by 258 · cited 1×
“Although RV Ees can also be measured if one knows end-systolic RV pressure and volume, it does not describe RV contractility as much as systolic ventricular interdependence [23] because more than half of RV developed pressure comes from LV free wall contraction [24].”
BackgroundPerformance of the right ventricle under stress: relation to right coronary flow
Brooks, H. L., Kirk, E. S., Vokonas, P., Urschel, C. W., & Sonnenblick, E. H. (1971) · Journal of Clinical Investigation · doi:10.1172/jci106712 · Cited by 240 · cited 2×
“Since RV coronary perfusion primarily occurs during systole, maintaining coronary perfusion pressure greater than pulmonary artery pressure by the use of systemic vasopressor therapy is also indicted [27].”
BackgroundJardin, F., Dubourg, O., Guéret, P., Delorme, G., & Bourdarias, J.-P. (1987) · Journal of the American College of Cardiology · doi:10.1016/s0735-1097(87)80119-5 · Cited by 237 · cited 1×
“This rapidly spiraling detrimental process can cause complete heart stand still and is presumably the cause of sudden death associated with massive pulmonary embolism [60].”
BackgroundHaeck, M. L. A., Scherptong, R. W. C., Marsan, N. A., Holman, E. R., Schalij, M. J., Bax, J. J., Vliegen, H. W., & Delgado, V. (2012) · Circulation Cardiovascular Imaging · doi:10.1161/circimaging.111.971465 · Cited by 233
Cardiovascular effects of positive end-expiratory pressure in dogs
Cassidy, S. S., Robertson, C. H., Pierce, A. K., & Johnson, R. L. (1978) · Journal of Applied Physiology · doi:10.1152/jappl.1978.44.5.743 · Cited by 202 · cited 1×
“both spontaneous [35] and positive pressure-induced hyperinflation [36–38] cause similar compressive effects”
BackgroundFukuda, Y., Tanaka, H., Sugiyama, D., Ryo, K., Onishi, T., Fukuya, H., Nogami, M., Ohno, Y., Emoto, N., Kawai, H., et al. (2011) · Journal of the American Society of Echocardiography · doi:10.1016/j.echo.2011.06.005 · Cited by 192 · cited 1×
“Assessment of RV strain in the setting of chronic pulmonary hypertension can be done using RV speckle tracking from echocardiographic images of the RV free wall once RV hypertrophy has developed [54].”
BackgroundMeasurements of Right Ventricular Volumes during Fluid Challenge
Reuse, C., Vincent, J.-L., & Pinsky, M. R. (1990) · Chest · doi:10.1378/chest.98.6.1450 · Cited by 175 · cited 1×
“If, as with the left ventricle, increased RV filling increased RV wall stretch, then one would expect RV ejection fraction to increase by the Frank–Starling mechanism [12–14].”
Self-citationDeterminants of pulmonary arterial flow variation during respiration
Pinsky, M. R. (1984) · Journal of Applied Physiology · doi:10.1152/jappl.1984.56.5.1237 · Cited by 173
Self-citationVentriculoarterial decoupling in human septic shock
Guarracino, F., Ferro, B., Morelli, A., Bertini, P., Baldassarri, R., & Pinsky, M. R. (2014) · Critical Care · doi:10.1186/cc13842 · Cited by 143
Self-citationVentriculo-arterial decoupling in acutely altered hemodynamic states
Guarracino, F., Baldassarri, R., & Pinsky, M. R. (2013) · Critical Care · doi:10.1186/cc12522 · Cited by 143 · cited 1×
“5, can result from changes in LV Ees, Ea, or both [47].”
BackgroundSelf-citationEffect of Positive End-expiratory Pressure on Right Ventricular Function in Humans
Pinsky, M. R., DeSmet, J.-M., & Vincent, J. (1992) · American Review of Respiratory Disease · doi:10.1164/ajrccm/146.3.681 · Cited by 139 · cited 1×
“[11] subsequently duplicated these findings in post-operative cardiac surgery patients by examining the effect of changing ITP and end-expiratory lung volume by varying positive endexpiratory pressure (PEEP) on RV function.”
BackgroundSelf-citationStone, I. S., Barnes, N. C., James, W.-Y., Midwinter, D., Boubertakh, R., Follows, R., John, L., & Petersen, S. E. (2016) · American Journal of Respiratory and Critical Care Medicine · doi:10.1164/rccm.201508-1647oc · Cited by 134 · cited 1×
“This hyperinflation-induced impaired LV filling forms the basis for the recently completed clinical trial of pharmacologic lung reduction therapy using bronchodilator therapy [41].”
BackgroundJanicki, J. S. (1990) · PubMed · Cited by 104
Peripheral vascular decoupling in porcine endotoxic shock
Hatib, F., Jansen, J. R. C., & Pinsky, M. R. (2011) · Journal of Applied Physiology · doi:10.1152/japplphysiol.00066.2011 · Cited by 87 · cited 1×
“Presumably, this uncoupling occurs owing to a primary decrease in peripheral impedance and increase in peripheral arterial compliance [49].”
BackgroundSelf-citationCentral venous pressure is a stopping rule, not a target of fluid resuscitation
Pinsky, M. R., Kellum, J. A., & Bellomo, R. (2014) · Critical Care and Resuscitation · doi:10.1016/s1441-2772(23)01614-9 · Cited by 43
Self-citationRight Ventricular Function in Human Sepsis
Dhainaut, J.-F., Pinsky, M. R., Nouria, S., Slomka, F., & Brunet, F. P. (1997) · CHEST Journal · doi:10.1378/chest.112.4.1043 · Cited by 42
Self-citationEffect of the pericardium on systolic ventricular interdependence in the dog
Schertz, C., & Pinsky, M. R. (1993) · Journal of Critical Care · doi:10.1016/0883-9441(93)90029-k · Cited by 23 · cited 1×
“pericardial volume limitations [56], spiraling to cardiogenic shock.”
BackgroundSelf-citationAkimoto, T., & Hammerman, M. R. (2003) · American Journal of Physiology-Cell Physiology · doi:10.1152/ajpcell.00436.2002 · Cited by 10
Cited by
Mechanical Circulatory Support Devices for Acute Right Ventricular Failure
Kapur, N. K., Esposito, M. L., Bader, Y., Morine, K. J., Kiernan, M. S., Pham, D. T., & Burkhoff, D. (2017) · Circulation · doi:10.1161/circulationaha.116.025290 · Cited by 358
Right Ventricular Dysfunction in Early Sepsis and Septic Shock
Lanspa, M. J., Cirulis, M. M., Wiley, B. M., Olsen, T. D., Wilson, E. L., Beesley, S. J., Brown, S. M., Hirshberg, E. L., & Grissom, C. K. (2021) · Chest · doi:10.1016/j.chest.2020.09.274 · Cited by 185
Metadata
- Authors
- Pinsky, M. R.
- Venue
- Critical Care
- Published
- 2016-09-10
- Volume
- 20
- Issue
- 1
- Pages
- 266-266
- ISSN
- 1364-8535 (ISSN-L)
- OpenAlex
- W2509429393
- Cited by
- 212
- References
- 39
- FWCI
- 12.98
- Type
- journal article
- Language
- en
- Open access
- gold
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.